Normalized to: Hakobyan, R.
[1]
oai:arXiv.org:1707.08042 [pdf] - 1735166
First results from the DEAP-3600 dark matter search with argon at SNOLAB
Collaboration, DEAP-3600;
:;
Amaudruz, P. -A.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bishop, D.;
Bonatt, J.;
Boorman, G.;
Boulay, M. G.;
Broerman, B.;
Bromwich, T.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Chan, S.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Dittmeier, S.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Giampa, P.;
Golovko, V. V.;
Gorel, P.;
Gornea, R.;
Grace, E.;
Graham, K.;
Gulyev, E.;
Hakobyan, R.;
Hall, A.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Jillings, C. J.;
Kamaev, O.;
Kemp, A.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Lidgard, J. J.;
Lim, C.;
Lindner, T.;
Linn, Y.;
Liu, S.;
Majewski, P.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mead, S.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Muir, A.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ohlmann, C.;
Olchanski, K.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T. R.;
Rand, E. T.;
Rau, W.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Shaw, B.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Taylor, J.;
Veloce, L.;
Vázquez-Jáuregui, E.;
Walding, J.;
Ward, M.;
Westerdale, S.;
Woolsey, E.;
Zielinski, J.
Submitted: 2017-07-25, last modified: 2018-08-13
This paper reports the first results of a direct dark matter search with the
DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was
performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target
mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg
capacity. The LAr is viewed by an array of PMTs, which would register
scintillation light produced by rare nuclear recoil signals induced by dark
matter particle scattering. An analysis of 4.44 live days (fiducial exposure of
9.87 tonne-days) of data taken with the nearly full detector during the initial
filling phase demonstrates the detector performance and the best electronic
recoil rejection using pulse-shape discrimination in argon, with leakage
$<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate
signal events are observed, which results in the leading limit on WIMP-nucleon
spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100
GeV/c$^2$ WIMP mass (90% C.L.).
[2]
oai:arXiv.org:0904.2930 [pdf] - 1488343
Measurement of the scintillation time spectra and pulse-shape
discrimination of low-energy beta and nuclear recoils in liquid argon with
DEAP-1
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bonatt, J.;
Boudjemline, K.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
Duncan, F.;
Fatemighomi, N.;
Ford, R.;
Gagnon, R.;
Giampa, P.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P.;
Hearns, C.;
Hofgartner, J.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
La Zia, F.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
Mehdiyev, R.;
McKinsey, D. N.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, A. J.;
O'Dwyer, E.;
Olsen, K.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T.;
Rau, W.;
Retière, F.;
Ronquest, M.;
Seeburn, N.;
Skensved, P.;
Smith, B.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Walding, J.;
Ward, M.
Submitted: 2009-04-20, last modified: 2016-09-14
The DEAP-1 low-background liquid argon detector was used to measure
scintillation pulse shapes of electron and nuclear recoil events and to
demonstrate the feasibility of pulse-shape discrimination (PSD) down to an
electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction
of beta events that are misidentified as nuclear recoils to be $<1.4\times
10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil
acceptance of at least 90%, with 4% systematic uncertainty on the absolute
energy scale. The discrimination measurement on surface was limited by nuclear
recoils induced by cosmic-ray generated neutrons. This was improved by moving
the detector to the SNOLAB underground laboratory, where the reduced background
rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains $1.23\times10^8$ events. One of those, in the
underground data set, is in the nuclear-recoil region of interest. Taking into
account the expected background of 0.48 events coming from random pileup, the
resulting upper limit on the electronic recoil contamination is
$<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil
acceptance of at least 90%, with 6% systematic uncertainty on the absolute
energy scale.
We developed a general mathematical framework to describe PSD parameter
distributions and used it to build an analytical model of the distributions
observed in DEAP-1. Using this model, we project a misidentification fraction
of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for
a detector with 8 PE/keVee light yield. This reduction enables a search for
spin-independent scattering of WIMPs from 1000 kg of liquid argon with a
WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming
negligible contribution from nuclear recoil backgrounds.
[3]
oai:arXiv.org:1211.0909 [pdf] - 890838
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Boudjemline, K.;
Caldwell, M. G. Boulay B. Cai T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Contreras, D.;
Dering, K.;
Duncan, F.;
Ford, R.;
Giuliani, R. Gagnon F.;
Golovko, M. Gold V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
Li, O.;
Lidgard, J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McKinsey, D.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, T.;
O'Dwyer, E.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Pollmann, T.;
Rau, W.;
Retiere, F.;
Ronquest, M.;
Skensved, P.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Ward, M.
Submitted: 2012-11-05, last modified: 2014-04-23
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was
operated underground at SNOLAB in order to test the techniques and measure the
backgrounds inherent to single phase detection, in support of the
\mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled
through material selection, construction techniques, pulse shape discrimination
and event reconstruction. This report details the analysis of background events
observed in three iterations of the DEAP-1 detector, and the measures taken to
reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16
and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background
spectrum near the region of interest for Dark Matter detection in the DEAP-1
detector can be described considering events from three sources: radon
daughters decaying on the surface of the active volume, the expected rate of
electromagnetic events misidentified as nuclear recoils due to inefficiencies
in the pulse shape discrimination, and leakage of events from outside the
fiducial volume due to imperfect position reconstruction. These backgrounds
statistically account for all observed events, and they will be strongly
reduced in the DEAP-3600 detector due to its higher light yield and simpler
geometry.