Normalized to: Hahn, T.
[1]
oai:arXiv.org:1903.02464 [pdf] - 1859121
4MOST: Project overview and information for the First Call for Proposals
de Jong, R. S.;
Agertz, O.;
Berbel, A. Agudo;
Aird, J.;
Alexander, D. A.;
Amarsi, A.;
Anders, F.;
Andrae, R.;
Ansarinejad, B.;
Ansorge, W.;
Antilogus, P.;
Anwand-Heerwart, H.;
Arentsen, A.;
Arnadottir, A.;
Asplund, M.;
Auger, M.;
Azais, N.;
Baade, D.;
Baker, G.;
Baker, S.;
Balbinot, E.;
Baldry, I. K.;
Banerji, M.;
Barden, S.;
Barklem, P.;
Barthélémy-Mazot, E.;
Battistini, C.;
Bauer, S.;
Bell, C. P. M.;
Bellido-Tirado, O.;
Bellstedt, S.;
Belokurov, V.;
Bensby, T.;
Bergemann, M.;
Bestenlehner, J. M.;
Bielby, R.;
Bilicki, M.;
Blake, C.;
Bland-Hawthorn, J.;
Boeche, C.;
Boland, W.;
Boller, T.;
Bongard, S.;
Bongiorno, A.;
Bonifacio, P.;
Boudon, D.;
Brooks, D.;
Brown, M. J. I.;
Brown, R.;
Brüggen, M.;
Brynnel, J.;
Brzeski, J.;
Buchert, T.;
Buschkamp, P.;
Caffau, E.;
Caillier, P.;
Carrick, J.;
Casagrande, L.;
Case, S.;
Casey, A.;
Cesarini, I.;
Cescutti, G.;
Chapuis, D.;
Chiappini, C.;
Childress, M.;
Christlieb, N.;
Church, R.;
Cioni, M. -R. L.;
Cluver, M.;
Colless, M.;
Collett, T.;
Comparat, J.;
Cooper, A.;
Couch, W.;
Courbin, F.;
Croom, S.;
Croton, D.;
Daguisé, E.;
Dalton, G.;
Davies, L. J. M.;
Davis, T.;
de Laverny, P.;
Deason, A.;
Dionies, F.;
Disseau, K.;
Doel, P.;
Döscher, D.;
Driver, S. P.;
Dwelly, T.;
Eckert, D.;
Edge, A.;
Edvardsson, B.;
Youssoufi, D. El;
Elhaddad, A.;
Enke, H.;
Erfanianfar, G.;
Farrell, T.;
Fechner, T.;
Feiz, C.;
Feltzing, S.;
Ferreras, I.;
Feuerstein, D.;
Feuillet, D.;
Finoguenov, A.;
Ford, D.;
Fotopoulou, S.;
Fouesneau, M.;
Frenk, C.;
Frey, S.;
Gaessler, W.;
Geier, S.;
Fusillo, N. Gentile;
Gerhard, O.;
Giannantonio, T.;
Giannone, D.;
Gibson, B.;
Gillingham, P.;
González-Fernández, C.;
Gonzalez-Solares, E.;
Gottloeber, S.;
Gould, A.;
Grebel, E. K.;
Gueguen, A.;
Guiglion, G.;
Haehnelt, M.;
Hahn, T.;
Hansen, C. J.;
Hartman, H.;
Hauptner, K.;
Hawkins, K.;
Haynes, D.;
Haynes, R.;
Heiter, U.;
Helmi, A.;
Aguayo, C. Hernandez;
Hewett, P.;
Hinton, S.;
Hobbs, D.;
Hoenig, S.;
Hofman, D.;
Hook, I.;
Hopgood, J.;
Hopkins, A.;
Hourihane, A.;
Howes, L.;
Howlett, C.;
Huet, T.;
Irwin, M.;
Iwert, O.;
Jablonka, P.;
Jahn, T.;
Jahnke, K.;
Jarno, A.;
Jin, S.;
Jofre, P.;
Johl, D.;
Jones, D.;
Jönsson, H.;
Jordan, C.;
Karovicova, I.;
Khalatyan, A.;
Kelz, A.;
Kennicutt, R.;
King, D.;
Kitaura, F.;
Klar, J.;
Klauser, U.;
Kneib, J.;
Koch, A.;
Koposov, S.;
Kordopatis, G.;
Korn, A.;
Kosmalski, J.;
Kotak, R.;
Kovalev, M.;
Kreckel, K.;
Kripak, Y.;
Krumpe, M.;
Kuijken, K.;
Kunder, A.;
Kushniruk, I.;
Lam, M. I;
Lamer, G.;
Laurent, F.;
Lawrence, J.;
Lehmitz, M.;
Lemasle, B.;
Lewis, J.;
Li, B.;
Lidman, C.;
Lind, K.;
Liske, J.;
Lizon, J. -L.;
Loveday, J.;
Ludwig, H. -G.;
McDermid, R. M.;
Maguire, K.;
Mainieri, V.;
Mali, S.;
Mandel, H.;
Mandel, K.;
Mannering, L.;
Martell, S.;
Delgado, D. Martinez;
Matijevic, G.;
McGregor, H.;
McMahon, R.;
McMillan, P.;
Mena, O.;
Merloni, A.;
Meyer, M. J.;
Michel, C.;
Micheva, G.;
Migniau, J. -E.;
Minchev, I.;
Monari, G.;
Muller, R.;
Murphy, D.;
Muthukrishna, D.;
Nandra, K.;
Navarro, R.;
Ness, M.;
Nichani, V.;
Nichol, R.;
Nicklas, H.;
Niederhofer, F.;
Norberg, P.;
Obreschkow, D.;
Oliver, S.;
Owers, M.;
Pai, N.;
Pankratow, S.;
Parkinson, D.;
Parry, I.;
Paschke, J.;
Paterson, R.;
Pecontal, A.;
Phillips, D.;
Pillepich, A.;
Pinard, L.;
Pirard, J.;
Piskunov, N.;
Plank, V.;
Plüschke, D.;
Pons, E.;
Popesso, P.;
Power, C.;
Pragt, J.;
Pramskiy, A.;
Pryer, D.;
Quattri, M.;
Queiroz, A. B. de Andrade;
Quirrenbach, A.;
Rahurkar, S.;
Raichoor, A.;
Ramstedt, S.;
Rau, A.;
Recio-Blanco, A.;
Reiss, R.;
Renaud, F.;
Revaz, Y.;
Rhode, P.;
Richard, J.;
Richter, A. D.;
Rix, H. -W.;
Robotham, A. S. G.;
Roelfsema, R.;
Romaniello, M.;
Rosario, D.;
Rothmaier, F.;
Roukema, B.;
Ruchti, G.;
Rupprecht, G.;
Rybizki, J.;
Ryde, N.;
Saar, A.;
Sadler, E.;
Sahlén, M.;
Salvato, M.;
Sassolas, B.;
Saunders, W.;
Saviauk, A.;
Sbordone, L.;
Schmidt, T.;
Schnurr, O.;
Scholz, R. -D.;
Schwope, A.;
Seifert, W.;
Shanks, T.;
Sheinis, A.;
Sivov, T.;
Skúladóttir, Á.;
Smartt, S.;
Smedley, S.;
Smith, G.;
Smith, R.;
Sorce, J.;
Spitler, L.;
Starkenburg, E.;
Steinmetz, M.;
Stilz, I.;
Storm, J.;
Sullivan, M.;
Sutherland, W.;
Swann, E.;
Tamone, A.;
Taylor, E. N.;
Teillon, J.;
Tempel, E.;
ter Horst, R.;
Thi, W. -F.;
Tolstoy, E.;
Trager, S.;
Traven, G.;
Tremblay, P. -E.;
Tresse, L.;
Valentini, M.;
van de Weygaert, R.;
Ancker, M. van den;
Veljanoski, J.;
Venkatesan, S.;
Wagner, L.;
Wagner, K.;
Walcher, C. J.;
Waller, L.;
Walton, N.;
Wang, L.;
Winkler, R.;
Wisotzki, L.;
Worley, C. C.;
Worseck, G.;
Xiang, M.;
Xu, W.;
Yong, D.;
Zhao, C.;
Zheng, J.;
Zscheyge, F.;
Zucker, D.
Submitted: 2019-03-06, last modified: 2019-04-01
We introduce the 4-metre Multi-Object Spectroscopic Telescope (4MOST), a new
high-multiplex, wide-field spectroscopic survey facility under development for
the four-metre-class Visible and Infrared Survey Telescope for Astronomy
(VISTA) at Paranal. Its key specifications are: a large field of view (FoV) of
4.2 square degrees and a high multiplex capability, with 1624 fibres feeding
two low-resolution spectrographs ($R = \lambda/\Delta\lambda \sim 6500$), and
812 fibres transferring light to the high-resolution spectrograph ($R \sim
20\,000$). After a description of the instrument and its expected performance,
a short overview is given of its operational scheme and planned 4MOST
Consortium science; these aspects are covered in more detail in other articles
in this edition of The Messenger. Finally, the processes, schedules, and
policies concerning the selection of ESO Community Surveys are presented,
commencing with a singular opportunity to submit Letters of Intent for Public
Surveys during the first five years of 4MOST operations.
[2]
oai:arXiv.org:1505.06492 [pdf] - 1056016
PEPSI: The high-resolution echelle spectrograph and polarimeter for the
Large Binocular Telescope
Strassmeier, K. G.;
Ilyin, I.;
Järvinen, A.;
Weber, M.;
Woche, M.;
Barnes, S. I.;
Bauer, S. -M.;
Beckert, E.;
Bittner, W.;
Bredthauer, R.;
Carroll, T. A.;
Denker, C.;
Dionies, F.;
DiVarano, I.;
Döscher, D.;
Fechner, T.;
Feuerstein, D.;
Granzer, T.;
Hahn, T.;
Harnisch, G.;
Hofmann, A.;
Lesser, M.;
Paschke, J.;
Pankratow, S.;
Plank, V.;
Plüschke, D.;
Popow, E.;
Sablowski, D.;
Storm, J.
Submitted: 2015-05-24
PEPSI is the bench-mounted, two-arm, fibre-fed and stabilized Potsdam Echelle
Polarimetric and Spectroscopic Instrument for the 2x8.4 m Large Binocular
Telescope (LBT). Three spectral resolutions of either 43 000, 120 000 or 270
000 can cover the entire optical/red wavelength range from 383 to 907 nm in
three exposures. Two 10.3kx10.3k CCDs with 9-{\mu}m pixels and peak quantum
efficiencies of 96 % record a total of 92 echelle orders. We introduce a new
variant of a wave-guide image slicer with 3, 5, and 7 slices and peak
efficiencies between 96 %. A total of six cross dispersers cover the six
wavelength settings of the spectrograph, two of them always simultaneously.
These are made of a VPH-grating sandwiched by two prisms. The peak efficiency
of the system, including the telescope, is 15% at 650 nm, and still 11% and 10%
at 390 nm and 900 nm, respectively. In combination with the 110 m2
light-collecting capability of the LBT, we expect a limiting magnitude of 20th
mag in V in the low-resolution mode. The R=120 000 mode can also be used with
two, dual-beam Stokes IQUV polarimeters. The 270 000-mode is made possible with
the 7-slice image slicer and a 100- {\mu}m fibre through a projected sky
aperture of 0.74", comparable to the median seeing of the LBT site. The
43000-mode with 12-pixel sampling per resolution element is our bad seeing or
faint-object mode. Any of the three resolution modes can either be used with
sky fibers for simultaneous sky exposures or with light from a stabilized
Fabry-Perot etalon for ultra-precise radial velocities. CCD-image processing is
performed with the dedicated data-reduction and analysis package PEPSI-S4S. A
solar feed makes use of PEPSI during day time and a 500-m feed from the 1.8 m
VATT can be used when the LBT is busy otherwise. In this paper, we present the
basic instrument design, its realization, and its characteristics.
[3]
oai:arXiv.org:1210.3167 [pdf] - 575095
A retrospective of the GREGOR solar telescope in scientific literature
Denker, C.;
von der Lühe, O.;
Feller, A.;
Arlt, K.;
Balthasar, H.;
Bauer, S. -M.;
González, N. Bello;
Berkefeld, T.;
Caligari, P.;
Collados, M.;
Fischer, A.;
Granzer, T.;
Hahn, T.;
Halbgewachs, C.;
Heidecke, F.;
Hofmann, A.;
Kentischer, T.;
Klvaňa, M.;
Kneer, F.;
Lagg, A.;
Nicklas, H.;
Popow, E.;
Puschmann, K. G.;
Rendtel, J.;
Schmidt, D.;
Schmidt, W.;
Sobotka, M.;
Solanki, S. K.;
Soltau, D.;
Staude, J.;
Strassmeier, K. G.;
Volkmer, R.;
Waldmann, T.;
Wiehr, E.;
Wittmann, A. D.;
Woche, M.
Submitted: 2012-10-11
In this review, we look back upon the literature, which had the GREGOR solar
telescope project as its subject including science cases, telescope subsystems,
and post-focus instruments. The articles date back to the year 2000, when the
initial concepts for a new solar telescope on Tenerife were first presented at
scientific meetings. This comprehensive bibliography contains literature until
the year 2012, i.e., the final stages of commissioning and science
verification. Taking stock of the various publications in peer-reviewed
journals and conference proceedings also provides the "historical" context for
the reference articles in this special issue of Astronomische
Nachrichten/Astronomical Notes.
[4]
oai:arXiv.org:1210.2921 [pdf] - 590823
The GREGOR Fabry-P\'erot Interferometer
Puschmann, K. G.;
Denker, C.;
Kneer, F.;
Erdogan, N. Al;
Balthasar, H.;
Bauer, S. M.;
Beck, C.;
González, N. Bello;
Collados, M.;
Hahn, T.;
Hirzberger, J.;
Hofmann, A.;
Louis, R. E.;
Nicklas, H.;
Okunev, O.;
Pillet, V. Martínez;
Popow, E.;
Seelemann, T.;
Volkmer, R.;
Wittmann, A. D.;
Woche, M.
Submitted: 2012-10-10
The GREGOR Fabry-P\'erot Interferometer (GFPI) is one of three first-light
instruments of the German 1.5-meter GREGOR solar telescope at the Observatorio
del Teide, Tenerife, Spain. The GFPI uses two tunable etalons in collimated
mounting. Thanks to its large-format, high-cadence CCD detectors with
sophisticated computer hard- and software it is capable of scanning spectral
lines with a cadence that is sufficient to capture the dynamic evolution of the
solar atmosphere. The field-of-view (FOV) of 50" x 38" is well suited for quiet
Sun and sunspot observations. However, in the vector spectropolarimetric mode
the FOV reduces to 25" x 38". The spectral coverage in the spectroscopic mode
extends from 530-860 nm with a theoretical spectral resolution R of about
250,000, whereas in the vector spectropolarimetric mode the wavelength range is
at present limited to 580-660 nm. The combination of fast narrow-band imaging
and post-factum image restoration has the potential for discovery science
concerning the dynamic Sun and its magnetic field at spatial scales down to
about 50 km on the solar surface.
[5]
oai:arXiv.org:1111.5509 [pdf] - 639012
The GREGOR Fabry-Perot Interferometer - A New Instrument for
High-Resolution Spectropolarimetric Solar Observations
Submitted: 2011-11-23, last modified: 2011-11-24
Fabry-Perot interferometers have advantages over slit spectrographs because
they allow fast narrow-band imaging and post-factum image reconstruction of
spectropolarimetric data. Temperature, plasma velocity, and magnetic field maps
can be derived from inversions of photospheric and chromospheric spectral
lines, thus, advancing our understanding of the dynamic Sun and its magnetic
fields at the smallest spatial scales. The GREGOR Fabry-Perot Interferometer
(GFPI) is one of two firstlight instruments of the 1.5-meter GREGOR solar
telescope, which is currently being commissioned at the Observatorio del Teide,
Tenerife, Spain. The GFPI operates close to the diffraction limit of GREGOR,
thus, providing access to fine structures as small as 60 km on the solar
surface. The field-of-view of 52"x 40" is sufficiently large to cover
significant portions of active regions. The GFPI is a tuneable dual-etalon
system in a collimated mounting. Equipped with a full-Stokes polarimeter, it
records spectropolarimetric data with a spectral resolution of R = 250,000 over
the wavelength range from 530-860 nm. Large-format, high-cadence CCD detectors
with powerful computer hard- and software facilitate scanning of spectral lines
in time spans corresponding to the evolution time-scale of solar features. We
present the main characteristics of the GFPI including the latest developments
in software, mechanical mounts, and optics.
[6]
oai:arXiv.org:astro-ph/0606329 [pdf] - 1233815
Probing unexplored territories with MUSE: a second generation instrument
for the VLT
Bacon, R.;
Bauer, S.;
Boehm, P.;
Boudon, D.;
Brau-Nogue, S.;
Caillier, P.;
Capoani, L.;
Carollo, C. M.;
Champavert, N.;
Contini, T.;
Daguise, E.;
Dalle, D.;
Delabre, B.;
Devriendt, J.;
Dreizler, S.;
Dubois, J.;
Dupieux, M.;
Dupin, J. P.;
Emsellem, E.;
Ferruit, P.;
Franx, M.;
Gallou, G.;
Gerssen, J.;
Guiderdoni, B.;
Hahn, T.;
Hofmann, D.;
Jarno, A.;
Kelz, A.;
Koehler, C.;
Kollatschny, W.;
Kosmalski, J.;
Laurent, F.;
Lilly, S. J.;
Lizon, J.;
Loupias, M.;
Lynn, S.;
Manescau, A.;
McDermid, R. M.;
Monstein, C.;
Nicklas, H.;
Pares, L.;
Pasquini, L.;
Pecontal-Rousset, A.;
Pecontal, E.;
Pello, R.;
Petit, C.;
Picat, J. -P.;
Popow, E.;
Quirrenbach, A.;
Reiss, R.;
Renault, E.;
Roth, M.;
Schaye, J.;
Soucail, G.;
Steinmetz, M.;
Stroebele, S.;
Stuik, R.;
Weilbacher, P.;
Wozniak, H.;
de Zeeuw, P. T.
Submitted: 2006-06-13
The Multi Unit Spectroscopic Explorer (MUSE) is a second-generation VLT
panoramic integral-field spectrograph under preliminary design study. MUSE has
a field of 1x1 arcmin**2 sampled at 0.2x0.2 arcsec**2 and is assisted by the
VLT ground layer adaptive optics ESO facility using four laser guide stars. The
simultaneous spectral range is 465-930 nm, at a resolution of R~3000. MUSE
couples the discovery potential of a large imaging device to the measuring
capabilities of a high-quality spectrograph, while taking advantage of the
increased spatial resolution provided by adaptive optics. This makes MUSE a
unique and tremendously powerful instrument for discovering and characterizing
objects that lie beyond the reach of even the deepest imaging surveys. MUSE has
also a high spatial resolution mode with 7.5x7.5 arcsec**2 field of view
sampled at 25 milli-arcsec. In this mode MUSE should be able to obtain
diffraction limited data-cubes in the 600-930 nm wavelength range. Although the
MUSE design has been optimized for the study of galaxy formation and evolution,
it has a wide range of possible applications; e.g. monitoring of outer planets
atmosphere, environment of young stellar objects, super massive black holes and
active nuclei in nearby galaxies or massive spectroscopic surveys of stellar
fields in the Milky Way and nearby galaxies.
[7]
oai:arXiv.org:astro-ph/0502581 [pdf] - 71372
PMAS, the Potsdam Multi-Aperture Spectrophotometer. I. Design,
Manufacture, and Performance
Roth, M. M.;
Kelz, A.;
Fechner, T.;
Hahn, T.;
Bauer, S. -M.;
Becker, T.;
Boehm, P.;
Christensen, L.;
Dionies, F.;
Paschke, J.;
Popow, E.;
Wolter, D.;
Schmoll, J.;
Laux, U.;
Altmann, W.
Submitted: 2005-02-28
We describe the design, manufacture, commissioning, and performance of PMAS,
the Potsdam Multi-Aperture Spectrophotometer. PMAS is a dedicated integral
field spectrophotometer, optimized to cover the optical wavelength regime of
0.35--1um. It is based on the lens array -- fiber bundle principle of
operation. The instrument employs an all-refractive fiber spectrograph, built
with CaF2 optics, to provide good transmission and high image quality over the
entire nominal wavelength range. A set of user-selectable reflective gratings
provides low to medium spectral resolution in first order of approx. 1.5, 3.2,
and 7 A, depending on the groove density (1200, 600, 300 gr/mm). While the
standard integral field unit (IFU) uses a 16x16 element lens array, which
provides seeing-limited sampling in a relatively small field-of-view (FOV) in
one of three magnifications (8x8, 12x12, or 16x16 arcsec^2, respectively), a
recently retrofitted bare fiber bundle IFU (PPak) expands the FOV to a
hexagonal area with a footprint of 65x74 arcsec^2. Other special features
include a cryogenic CCD camera for field acquisition and guiding, a nod-shuffle
mode for beam switching and improved sky background subtraction, and a scanning
Fabry-Perot etalon in combination with the standard IFU (PYTHEAS mode). PMAS
was initially designed and built as an experimental traveling instrument with
optical interfaces to various telescopes (Calar Alto 3.5m, ESO-VLT, LBT). It is
offered as a common user instrument at Calar Alto under contract with MPIA
Heidelberg since 2002.