Normalized to: Hagn, H.
[1]
oai:arXiv.org:1401.3332 [pdf] - 1345758
Energy-Dependent Light Quenching in CaWO$_4$ Crystals at mK Temperatures
Strauss, R.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Carli, W.;
Ciemniak, C.;
Erb, A.;
Feilitzsch, F. v.;
Gorla, P.;
Gütlein, A.;
Hagn, H.;
Hauff, D.;
Hellgartner, D.;
Jochum, J.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-01-14, last modified: 2016-01-25
Scintillating CaWO$_4$ single crystals are a promising multi-element target
for rare-event searches and are currently used in the direct Dark Matter
experiment CRESST (Cryogenic Rare Event Search with Superconducting
Thermometers). The relative light output of different particle interactions in
CaWO$_4$ is quantified by Quenching Factors (QFs). These are essential for an
active background discrimination and the identification of a possible signal
induced by weakly interacting massive particles (WIMPs). We present the first
precise measurements of the QFs of O, Ca and W at mK temperatures by
irradiating a cryogenic detector with a fast neutron beam. A clear energy
dependence of the QF of O and, less pronounced, of Ca was observed for the
first time. Furthermore, in CRESST neutron-calibration data a variation of the
QFs among different CaWO$_4$ single crystals was found. For typical CRESST
detectors the QFs in the region-of-interest (10-40$\,$keV) are
$QF_O^{ROI}=(11.2{\pm}0.5)\,$%, $QF_{Ca}^{ROI}=(5.94{\pm}0.49)\,$% and
$QF_W^{ROI}=(1.72{\pm}0.21)\,$%. The latest CRESST data (run32) is reanalyzed
using these fundamentally new results on light quenching in CaWO$_4$ having
moderate influence on the WIMP analysis. Their relevance for future CRESST runs
and for the clarification of previously published results of direct Dark Matter
experiments is emphasized.
[2]
oai:arXiv.org:1511.07722 [pdf] - 1317178
Intense Infrared Scintillation of Liquid Ar-Xe Mixtures
Neumeier, A.;
Dandl, T.;
Heindl, T.;
Himpsl, A.;
Hagn, H.;
Hofmann, M.;
Oberauer, L.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Wieser, J.;
Ulrich, A.
Submitted: 2015-11-24
Intense infrared (IR) light emission from liquid Ar-Xe mixtures has been
observed using 12 keV electron-beam excitation. The emission peaks at a
wavelength of 1.18 $\mu$m and the half-width of the emission band is 0.1
$\mu$m. Maximum intensity has been found for a 10 ppm xenon admixture in liquid
argon. The conversion efficiency of electron beam-power to IR-light is about 1%
(10000 photons per MeV electron energy deposited). A possible application of
this intense IR emission for a new particle discrimination concept in liquid
noble gas detectors is discussed. No light emission was found for perfectly
purified liquid argon in the wavelength range from 0.5 to 3.5 $\mu$m on the
current level of sensitivity.
[3]
oai:arXiv.org:0810.0132 [pdf] - 16940
Neutron Scattering Facility for Characterization of CRESST and EURECA
Detectors at mK Temperatures
Lanfranchi, J. -C.;
Ciemniak, C.;
Coppi, C.;
von Feilitzsch, F.;
Gütlein, A.;
Hagn, H.;
Isaila, C.;
Jochum, J.;
Kimmerle, M.;
Pfister, S.;
Potzel, W.;
Rau, W.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Scholl, S.;
Usherov, I.;
Westphal, W.
Submitted: 2008-10-01
CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) is an
experiment located at the Gran Sasso underground laboratory and aimed at the
direct detection of dark matter in the form of WIMPs. The setup has just
completed a one year commissioning run in 2007 and is presently starting a
physics run with an increased target mass. Scintillating $\mathrm{CaWO_4}$
single crystals, operated at temperatures of a few millikelvin, are used as
target to detect the tiny nuclear recoil induced by a WIMP. The powerful
background identification and rejection of $\alpha$, e$^{-}$ and $\gamma$
events is realized via the simultaneous measurement of a phonon and a
scintillation signal generated in the $\mathrm{CaWO_4}$ crystal. However,
neutrons could still be misidentified as a WIMP signature. Therefore, a
detailed understanding of the individual recoil behaviour in terms of phonon
generation and scintillation light emission due to scattering on Ca, O or W
nuclei, respectively, is mandatory. The only setup which allows to perform such
measurements at the operating temperature of the CRESST detectors has been
installed at the Maier-Leibnitz-Accelerator Laboratory in Garching and is
presently being commissioned. The design of this neutron scattering facility is
such that it can also be used for other target materials, e.g.
$\mathrm{ZnWO_4}$, $\mathrm{PbWO_4}$ and others as foreseen in the framework of
the future multitarget tonne-scale experiment EURECA (European Underground Rare
Event Calorimeter Array).