Normalized to: Hage, P.
[1]
oai:arXiv.org:1411.0299 [pdf] - 1231804
PESSTO : survey description and products from the first data release by
the Public ESO Spectroscopic Survey of Transient Objects
Smartt, S. J.;
Valenti, S.;
Fraser, M.;
Inserra, C.;
Young, D. R.;
Sullivan, M.;
Pastorello, A.;
Benetti, S.;
Gal-Yam, A.;
Knapic, C.;
Molinaro, M.;
Smareglia, R.;
Smith, K. W.;
Taubenberger, S.;
Yaron, O.;
Anderson, J. P.;
Ashall, C.;
Balland, C.;
Baltay, C.;
Barbarino, C.;
Bauer, F. E.;
Baumont, S.;
Bersier, D.;
Blagorodnova, N.;
Bongard, S.;
Botticella, M. T.;
Bufano, F.;
Bulla, M.;
Cappellaro, E.;
Campbell, H.;
Cellier-Holzem, F.;
Chen, T. -W.;
Childress, M. J.;
Clocchiatti, A.;
Contreras, C.;
Ora, M. Dall;
Danziger, J.;
de Jaeger, T.;
De Cia, A.;
Della Valle, M.;
Dennefeld, M.;
Elias-Rosa, N.;
Elman, N.;
Feindt, U.;
Fleury, M.;
Gall, E.;
Gonzalez-Gaitan, S.;
Galbany, L.;
Garoffolo, A. Morales;
Greggio, L.;
Guillou, L. L.;
Hachinger, S.;
Hadjiyska, E.;
Hage, P. E.;
Hillebrandt, W.;
Hodgkin, S.;
Hsiao, E. Y.;
James, P. A.;
Jerkstrand, A.;
Kangas, T.;
Kankare, E.;
Kotak, R.;
Kromer, M.;
Kuncarayakti, H.;
Leloudas, G.;
Lundqvist, P.;
Lyman, J. D.;
Hook, I. M.;
Maguire, K.;
Manulis, I.;
Margheim, S. J.;
Mattila, S.;
Maund, J. R.;
Mazzali, P. A.;
McCrum, M.;
McKinnon, R.;
Moreno-Raya, M. E.;
Nicholl, M.;
Nugent, P.;
Pain, R.;
Phillips, M. M.;
Pignata, G.;
Polshaw, J.;
Pumo, M. L.;
Rabinowitz, D.;
Reilly, E.;
Romero-Canizales, C.;
Scalzo, R.;
Schmidt, B.;
Schulze, S.;
Sim, S.;
Sollerman, J.;
Taddia, F.;
Tartaglia, L.;
Terreran, G.;
Tomasella, L.;
Turatto, M.;
Walker, E.;
Walton, N. A.;
Wyrzykowski, L.;
Yuan, F.;
Zampieri, L.
Submitted: 2014-11-02, last modified: 2015-05-10
The Public European Southern Observatory Spectroscopic Survey of Transient
Objects (PESSTO) began as a public spectroscopic survey in April 2012. We
describe the data reduction strategy and data products which are publicly
available through the ESO archive as the Spectroscopic Survey Data Release 1
(SSDR1). PESSTO uses the New Technology Telescope with EFOSC2 and SOFI to
provide optical and NIR spectroscopy and imaging. We target supernovae and
optical transients brighter than 20.5mag for classification. Science targets
are then selected for follow-up based on the PESSTO science goal of extending
knowledge of the extremes of the supernova population. The EFOSC2 spectra cover
3345-9995A (at resolutions of 13-18 Angs) and SOFI spectra cover 0.935-2.53
micron (resolutions 23-33 Angs) along with JHK imaging. This data release
contains spectra from the first year (April 2012 - 2013), consisting of all 814
EFOSC2 spectra and 95 SOFI spectra (covering 298 distinct objects), in standard
ESO Phase 3 format. We estimate the accuracy of the absolute flux calibrations
for EFOSC2 to be typically 15%, and the relative flux calibration accuracy to
be about 5%. The PESSTO standard NIR reduction process does not yet produce
high accuracy absolute spectrophotometry but the SOFI JHK imaging will improve
this. Future data releases will focus on improving the automated flux
calibration of the data products.
[2]
oai:arXiv.org:1306.5153 [pdf] - 1172199
Photometry of supernovae in an image series : methods and application to
the Supernova Legacy Survey (SNLS)
Submitted: 2013-06-21
We present a technique to measure lightcurves of time-variable point sources
on a spatially structured background from imaging data. The technique was
developed to measure light curves of SNLS supernovae in order to infer their
distances. This photometry technique performs simultaneous PSF photometry at
the same sky position on an image series. We describe two implementations of
the method: one that resamples images before measuring fluxes, and one which
does not. In both instances, we sketch the key algorithms involved and present
the validation using semi-artificial sources introduced in real images in order
to assess the accuracy of the supernova flux measurements relative to that of
surrounding stars. We describe the methods required to anchor these PSF fluxes
to calibrated aperture catalogs, in order to derive SN magnitudes. We find a
marginally significant bias of 2 mmag of the after-resampling method, and no
bias at the mmag accuracy for the non-resampling method. Given surrounding star
magnitudes, we determine the systematic uncertainty of SN magnitudes to be less
than 1.5 mmag, which represents about one third of the current photometric
calibration uncertainty affecting SN measurements. The SN photometry delivers
several by-products: bright star PSF flux mea- surements which have a
repeatability of about 0.6%, as for aperture measurements; we measure relative
astrometric positions with a noise floor of 2.4 mas for a single-image bright
star measurement; we show that in all bands of the MegaCam instrument, stars
exhibit a profile linearly broadening with flux by about 0.5% over the whole
brightness range.
[3]
oai:arXiv.org:1212.4864 [pdf] - 1158630
Improved Photometric Calibration of the SNLS and the SDSS Supernova
Surveys
Betoule, M.;
Marriner, J.;
Regnault, N.;
Cuillandre, J. -C.;
Astier, P.;
Guy, J.;
Balland, C.;
Hage, P. El;
Hardin, D.;
Kessler, R.;
Guillou, L. Le;
Mosher, J.;
Pain, R.;
Rocci, P. -F.;
Sako, M.;
Schahmaneche, K.
Submitted: 2012-12-19
We present a combined photometric calibration of the SNLS and the SDSS
supernova survey, which results from a joint effort of the SDSS and the SNLS
collaborations. We deliver fluxes calibrated to the HST spectrophotometric star
network for large sets of tertiary stars that cover the science fields of both
surveys in all photometric bands. We also cross-calibrate directly the two
surveys and demonstrate their consistency. For each survey the flat-fielding is
revised based on the analysis of dithered star observations. The calibration
transfer from the HST spectrophotometric standard stars to the multi-epoch
tertiary standard star catalogs in the science fields follows three different
paths: observations of primary standard stars with the SDSS PT telescope;
observations of Landolt secondary standard stars with SNLS MegaCam instrument
at CFHT; and direct observation of faint HST standard stars with MegaCam. In
addition, the tertiary stars for the two surveys are cross-calibrated using
dedicated MegaCam observations of stripe 82. This overlap enables the
comparison of these three calibration paths and justifies using their
combination to improve the calibration accuracy. Flat-field corrections have
improved the uniformity of each survey as demonstrated by the comparison of
photometry in overlapping fields: the rms of the difference between the two
surveys is 3 mmag in gri, 4 mmag in z and 8 mmag in u. We also find a
remarkable agreement (better than 1%) between the SDSS and the SNLS calibration
in griz. The cross-calibration and the introduction of direct calibration
observations bring redundancy and strengthen the confidence in the resulting
calibration. We conclude that the surveys are calibrated to the HST with a
precision of about 0.4% in griz. This precision is comparable to the external
uncertainty affecting the color of the HST primary standard stars.