Gurevich, Yulia V.
Normalized to: Gurevich, Y.
5 article(s) in total. 35 co-authors, from 1 to 4 common article(s). Median position in authors list is 4,0.
[1]
oai:arXiv.org:2003.08510 [pdf] - 2124673
An improved analysis framework for axion dark matter searches
Palken, D. A.;
Brubaker, B. M.;
Malnou, M.;
Kenany, S. Al;
Backes, K. M.;
Cahn, S. B.;
Gurevich, Y. V.;
Lamoreaux, S. K.;
Lewis, S. M.;
Maruyama, R. H.;
Rapidis, N. M.;
Root, J. R.;
Simanovskaia, M.;
Shokair, T. M.;
Singh, Sukhman;
Speller, D. H.;
Urdinaran, I.;
van Bibber, K.;
Zhong, L.;
Lehnert, K. W.
Submitted: 2020-03-18, last modified: 2020-06-13
In experiments searching for axionic dark matter, the use of the standard
threshold-based data analysis discards valuable information. We present a
Bayesian analysis framework that builds on an existing processing protocol to
extract more information from the data of coherent axion detectors such as
operating haloscopes. The analysis avoids logical subtleties that accompany the
standard analysis framework and enables greater experimental flexibility on
future data runs. Performing this analysis on the existing data from the
HAYSTAC experiment, we find improved constraints on the axion-photon coupling
$g_\gamma$ while also identifying the most promising regions of parameter space
within the $23.15$--$24.0$ $\mu$eV mass range. A comparison with the standard
threshold analysis suggests a $36\%$ improvement in scan rate from our
analysis, demonstrating the utility of this framework for future axion
haloscope analyses.
[2]
oai:arXiv.org:2003.08205 [pdf] - 2066592
Rubidium transitions as wavelength reference for astronomical Doppler
spectrographs
Rogozin, Dmytro;
Feger, Tobias;
Schwab, Christian;
Gurevich, Yulia V.;
Raskin, Gert;
Coutts, David W.;
Stuermer, Julian;
Seifahrt, Andreas;
Fuehrer, Thorsten;
Legero, Thomas;
van Winckel, Hans;
Halverson, Sam;
Quirrenbach, Andreas
Submitted: 2020-03-17
Precise wavelength calibration is a critical issue for high-resolution
spectroscopic observations. The ideal calibration source should be able to
provide a very stable and dense grid of evenly distributed spectral lines of
constant intensity. A new method which satisfies all mentioned conditions has
been developed by our group. The approach is to actively measure the exact
position of a single spectral line of a Fabry-Perot etalon with very high
precision with a wavelength-tuneable laser and compare it to an extremely
stable wavelength standard. The ideal choice of standard is the D2 absorption
line of Rubidium, which has been used as an optical frequency standard for
decades. With this technique, the problem of stable wavelength calibration of
spectrographs becomes a problem of how reliably we can measure and anchor one
etalon line to the Rb transition. In this work we present our self-built module
for Rb saturated absorption spectroscopy and discuss its stability.
[3]
oai:arXiv.org:1611.07123 [pdf] - 1537416
Design and Operational Experience of a Microwave Cavity Axion Detector
for the 20-100 micro-eV Range
Kenany, S. Al;
Anil, M. A.;
Backes, K. M.;
Brubaker, B. M.;
Cahn, S. B.;
Carosi, G.;
Gurevich, Y. V.;
Kindel, W. F.;
Lamoreaux, S. K.;
Lehnert, K. W.;
Lewis, S. M.;
Malnou, M.;
Palken, D. A.;
Rapidis, N. M.;
Root, J. R.;
Simanovskaia, M.;
Shokair, T. M.;
Urdinaran, I.;
van Bibber, K. A.;
Zhong, L.
Submitted: 2016-11-21, last modified: 2017-02-22
We describe a dark matter axion detector designed, constructed, and operated
both as an innovation platform for new cavity and amplifier technologies and as
a data pathfinder in the $5 - 25$ GHz range ($\sim20-100\: \mu$eV). The
platform is small but flexible to facilitate the development of new microwave
cavity and amplifier concepts in an operational environment. The experiment has
recently completed its first data production; it is the first microwave cavity
axion search to deploy a Josephson parametric amplifier and a dilution
refrigerator to achieve near-quantum limited performance.
[4]
oai:arXiv.org:1610.02580 [pdf] - 1531959
First results from a microwave cavity axion search at 24 micro-eV
Brubaker, B. M.;
Zhong, L.;
Gurevich, Y. V.;
Cahn, S. B.;
Lamoreaux, S. K.;
Simanovskaia, M.;
Root, J. R.;
Lewis, S. M.;
Kenany, S. Al;
Backes, K. M.;
Urdinaran, I.;
Rapidis, N. M.;
Shokair, T. M.;
van Bibber, K. A.;
Palken, D. A.;
Malnou, M.;
Kindel, W. F.;
Anil, M. A.;
Lehnert, K. W.;
Carosi, G.
Submitted: 2016-10-08, last modified: 2017-02-09
We report on the first results from a new microwave cavity search for dark
matter axions with masses above $20~\mu\text{eV}$. We exclude axion models with
two-photon coupling $g_{a\gamma\gamma} \gtrsim 2\times10^{-14}~\text{GeV}^{-1}$
over the range $23.55~\mu\text{eV} < m_a < 24.0~\mu\text{eV}$. These results
represent two important achievements. First, we have reached cosmologically
relevant sensitivity an order of magnitude higher in mass than any existing
limits. Second, by incorporating a dilution refrigerator and Josephson
parametric amplifier, we have demonstrated total noise approaching the standard
quantum limit for the first time in an axion search.
[5]
oai:arXiv.org:1404.0004 [pdf] - 1292110
Stabilizing a Fabry-Perot etalon to 3 cm/s for spectrograph calibration
Submitted: 2014-03-31
We present a method of frequency stabilizing a broadband etalon that can
serve as a high-precision wavelength calibrator for an Echelle spectrograph.
Using a laser to probe the Doppler-free saturated absorption of the rubidium D2
line, we stabilize one etalon transmission peak directly to the rubidium
frequency. The rubidium transition is an established frequency standard and has
been used to lock lasers to fractional stabilities of $<10^{-12}$, a level of
accuracy far exceeding the demands of radial velocity (RV) searches for
exoplanets. We describe a simple setup designed specifically for use at an
observatory and demonstrate that we can stabilize the etalon peak to a relative
precision of $<10^{-10}$; this is equivalent to 3 cm/s RV precision.