Normalized to: Guiseppe, V.
[1]
oai:arXiv.org:1912.06181 [pdf] - 2074437
A Low Energy Rare Event Search with the Majorana Demonstrator
MAJORANA Collaboration;
Wiseman, C.;
Arnquist, I. J.;
Avignone, F. T.;
Barabash, A. S.;
Barton, C. J.;
Bertrand, F. E.;
Bos, B.;
Busch, M.;
Buuck, M.;
Caldwell, T. S.;
Chan, Y-D.;
Christofferson, C. D.;
Chu, P. -H.;
Clark, M. L.;
Cuesta, C.;
Detwiler, J. A.;
Drobizhev, A.;
Edwins, D. W.;
Efremenko, Yu.;
Ejiri, H.;
Elliott, S. R.;
Gilliss, T.;
Giovanetti, G. K.;
Green, M. P.;
Gruszko, J.;
Guinn, I. S.;
Guiseppe, V. E.;
Haufe, C. R.;
Hegedus, R. J.;
Henning, R.;
Aguilar, D. Hervas;
Hoppe, E. W.;
Hostiuc, A.;
Kidd, M. F.;
Kim, I.;
Kouzes, R. T.;
Lopez, A. M.;
Lopez-Castano, J. M.;
Martin, E. L.;
Martin, R. D.;
Massarczyk, R.;
Meijer, S. J.;
Mertens, S.;
Myslik, J.;
Oli, T. K.;
Othman, G.;
Pettus, W.;
Poon, A. W. P.;
Radford, D. C.;
Rager, J.;
Reine, A. L.;
Rielage, K.;
Ruof, N. W.;
Sayki, B.;
Stortini, M. J.;
Tedeschi, D.;
Varner, R. L.;
Wilkerson, J. F.;
Xu, W.;
Yu, C. -H.;
Zhu, B. X.
Submitted: 2019-12-12
The MAJORANA DEMONSTRATOR is sensitive to rare events near its energy
threshold, including bosonic dark matter, solar axions, and lightly ionizing
particles. In this analysis, a novel training set of low energy small-angle
Compton scatter events is used to determine the efficiency of pulse shape
analysis cuts, and we present updated bosonic dark matter and solar axion
results from an 11.17 kg-y dataset using a 5 keV analysis threshold.
[2]
oai:arXiv.org:1801.10145 [pdf] - 1694006
First Limit on the Direct Detection of Lightly Ionizing Particles for
Electric Charge as Low as $e$/1000 with the \textsc{Majorana Demonstrator}
Alvis, S. I.;
Arnquist, I. J.;
Avignone, F. T.;
Barabash, A. S.;
Barton, C. J.;
Bertrand, F. E.;
Brudanin, V.;
Busch, M.;
Buuck, M.;
Caldwell, T. S.;
Chan, Y-D.;
Christofferson, C. D.;
Chu, P. -H.;
Cuesta, C.;
Detwiler, J. A.;
Dunagan, C.;
Efremenko, Yu.;
Ejiri, H.;
Elliott, S. R.;
Gilliss, T.;
Giovanetti, G. K.;
Green, M. P.;
Gruszko, J.;
Guinn, I. S.;
Guiseppe, V. E.;
Haufe, C. R.;
Hehn, L.;
Henning, R.;
Hoppe, E. W.;
Howe, M. A.;
Konovalov, S. I.;
Kouzes, R. T.;
Lopez, A. M.;
Martin, R. D.;
Massarczyk, R.;
Meijer, S. J.;
Mertens, S.;
Myslik, J.;
O'Shaughnessy, C.;
Othman, G.;
Pettus, W.;
Poon, A. W. P.;
Radford, D. C.;
Rager, J.;
Reine, A. L.;
Rielage, K.;
Robertson, R. G. H.;
Ruof, N. W.;
Shanks, B.;
Shirchenko, M.;
Suriano, A. M.;
Tedeschi, D.;
Varner, R. L.;
Vasilyev, S.;
Vorren, K.;
White, B. R.;
Wilkerson, J. F.;
Wiseman, C.;
Xu, W.;
Yakushev, E.;
Yu, C. -H.;
Yumatov, V.;
Zhitnikov, I.;
Zhu, B. X.
Submitted: 2018-01-30, last modified: 2018-05-29
The \textsc{Majorana Demonstrator} is an ultra low-background experiment
searching for neutrinoless double-beta decay in $^{76}$Ge. The heavily shielded
array of germanium detectors, placed nearly a mile underground at the Sanford
Underground Research Facility in Lead, South Dakota, also allows searches for
new exotic physics. Free, relativistic, lightly-ionizing particles with
electrical charges less than $e$ are forbidden by the standard model but
predicted by some of its extensions. If such particles exist, they might be
detected in the \textsc{Majorana Demonstrator} by searching for multiple-
detector events with individual-detector energy depositions down to 1 keV. This
search is background free and no candidate events have been found in 285 days
of data taking. New direct-detection limits are set for the flux of lightly
ionizing particles for charges as low as $e$/1000.
[3]
oai:arXiv.org:1408.1914 [pdf] - 1216195
Improving Photoelectron Counting and Particle Identification in
Scintillation Detectors with Bayesian Techniques
Akashi-Ronquest, M.;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bodmer, M.;
Boulay, M. G.;
Broerman, B.;
Buck, B.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chen, Y.;
Cleveland, B.;
Coakley, K.;
Dering, K.;
Duncan, F. A.;
Formaggio, J. A.;
Gagnon, R.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grace, E.;
Guerrero, N.;
Guiseppe, V.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Henning, R.;
Hime, A.;
Hofgartner, J.;
Jaditz, S.;
Jillings, C. J.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Kuzniak, M.;
LaTorre, A.;
Lawson, I.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Linden, S.;
McFarlane, K.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mathew, R.;
McDonald, A. B.;
Mei, D. -M.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J. A.;
Noble, T.;
O'Dwyer, E.;
Olsen, K.;
Gann, G. D. Orebi;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Perumpilly, G.;
Pollmann, T.;
Rau, P.;
Retiere, F.;
Rielage, K.;
Schnee, R.;
Seibert, S.;
Skensved, P.;
Sonley, T.;
Vazquez-Jauregui, E.;
Veloce, L.;
Walding, J.;
Wang, B.;
Wang, J.;
Ward, M.;
Zhang, C.
Submitted: 2014-08-08, last modified: 2014-12-12
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.
[4]
oai:arXiv.org:1403.4842 [pdf] - 799232
Update on the MiniCLEAN Dark Matter Experiment
Rielage, K.;
Akashi-Ronquest, M.;
Bodmer, M.;
Bourque, R.;
Buck, B.;
Butcher, A.;
Caldwell, T.;
Chen, Y.;
Coakley, K.;
Flores, E.;
Formaggio, J. A.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Grace, E.;
Griego, J.;
Guerrero, N.;
Guiseppe, V.;
Henning, R.;
Hime, A.;
Jaditz, S.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Latorre, A.;
Lawson, I.;
Linden, S.;
Lopez, F.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mei, D. -M.;
Monroe, J.;
Nikkel, J. A.;
Oertel, J.;
Gann, G. D. Orebi;
Palladino, K.;
Perumpilly, G.;
Rodriguez, L.;
Schnee, R.;
Seibert, S.;
Walding, J.;
Wang, B.;
Wang, J.;
Zhang, C.
Submitted: 2014-03-19
The direct search for dark matter is entering a period of increased
sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One
such technology that is being examined is a scintillation only noble liquid
experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to
detect nuclear recoils from WIMP dark matter and serves as a demonstration for
a future detector of order 50 to 100 tonnes. The liquid cryogen is
interchangeable between argon and neon to study the A$^{2}$ dependence of the
potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular
design with spherical geometry to maximize the light yield using cold
photomultiplier tubes in a single-phase detector. Pulse shape discrimination
techniques are used to separate nuclear recoil signals from electron recoil
backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate
the effective reach of the pulse shape discrimination capability. Assembly of
the experiment is underway at SNOLAB and an update on the project is given.
[5]
oai:arXiv.org:1403.0475 [pdf] - 797476
A search for bremsstrahlung solar axions using the Majorana
low-background BEGe detector at Kimballton (MALBEK)
Abgrall, N.;
Aguayo, E.;
Avignone, F. T.;
Barabash, A. S.;
Bertrand, F. E.;
Boswell, M.;
Brudanin, V.;
Busch, M.;
Caldwell, A. S.;
Chan, Y-D.;
Christofferson, C. D.;
Combs, D. C.;
Cooper, R. J.;
Creswick, R. J.;
Detwiler, J. A.;
Doe, P. J.;
Efremenko, Yu.;
Egorov, V.;
Elliott, S. R.;
Fast, J. E.;
Finnerty, P.;
Fraenkle, F. M.;
Galindo-Uribarri, A.;
Giovanetti, G. K.;
Goett, J.;
Green, M. P.;
Gruszko, J.;
Guiseppe, V. E.;
Gusev, K.;
Hegai, A.;
Henning, R.;
Hoppe, E. W.;
Howard, S.;
Howe, M. A.;
Keeter, K. J.;
Kidd, M. F.;
Knecht, A.;
Kochetov, O.;
Konovalov, S. I.;
Kouzes, R. T.;
LaFerriere, B. D.;
Leon, J.;
Leviner, L. E.;
Loach, J. C.;
MacMullin, J.;
MacMullin, S.;
Marino, M. G.;
Martin, R. D.;
Mertens, S.;
Orrell, J. L.;
O'Shaughnessy, C.;
Overman, N. R.;
Phillips, D. G.;
Poon, A. W. P.;
Pushkin, K.;
Radford, D. C.;
Rielage, K.;
Robertson, R. G. H.;
Ronquest, M. C.;
Schubert, A. G.;
Shanks, B.;
Shirchenko, M.;
Snavely, K. J.;
Snyder, N.;
Steele, D.;
Suriano, A. M.;
Thompson, J.;
Timkin, V.;
Varner, R. L.;
Vasilyev, S.;
Vetter, K.;
Vorren, K.;
White, B. R.;
Wilkerson, J. F.;
Xu, W.;
Yakushev, E.;
Young, A. R.;
Yu, C. H.;
Yumatov, V.
Submitted: 2014-03-03, last modified: 2014-03-17
A low-background, high-purity germanium detector has been used to search for
evidence of low-energy, bremsstrahlung-generated solar axions. An upper bound
of $1.36\times 10^{-11}$ $(95% CL)$ is placed on the direct coupling of DFSZ
model axions to electrons. The prospects for the sensitivity of the Majorana
Demonstrator array of point-contact germanium detectors to solar axions are
discussed in the context of the model-independent annual modulation due to the
seasonal variation of the earth-sun distance.