Normalized to: Guillaudin, O.
[1]
oai:arXiv.org:1903.02159 [pdf] - 2070434
Track length measurement of $^{19}$F$^+$ ions with the MIMAC Dark Matter
directional detector prototype
Tao, Y.;
Beaufort, C.;
Moric, I.;
Tao, C.;
Santos, D.;
Sauzet, N.;
Couturier, C.;
Guillaudin, O.;
Muraz, J. F.;
Naraghi, F.;
Zhou, N.;
Busto, J.
Submitted: 2019-03-05, last modified: 2020-03-26
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred
candidate for Dark Matter. WIMPs should interact with the nuclei of detectors.
If a robust signal is eventually observed in direct detection experiments, the
best signature to confirm its Galactic origin would be the nuclear recoil track
direction. The MIMAC collaboration has developed a low pressure gas detector
providing both the kinetic energy and three-dimensional track reconstruction of
nuclear recoils. In this paper we report the first ever observations of
$^{19}$F nuclei tracks in a $5$ cm drift prototype MIMAC detector, in the low
kinetic energy range ($6$-$26$ keV), using specially developed ion beam
facilities. We have measured the recoil track lengths and found significant
differences between our measurements and standard simulations. In order to
understand these differences, we have performed a series of complementary
experiments and simulations to study the impact of the diffusion and eventual
systematics. We show an unexpected dependence of the number of read-out
corresponding to the track on the electric field applied to the $512\
\mathrm{\mu m}$ gap of the Micromegas detector. We have introduced, based on
the flash-ADC observable, corrections in order to reconstruct the physical 3D
track length of the primary electron clouds proposing the physics behind these
corrections. We show that diffusion and space charge effects need to be taken
into account to explain the differences between measurements and standard
simulations. These measurements and simulations may shed a new light on the
high-gain TPC ionization signals in general and particularly at low energy.
[2]
oai:arXiv.org:1902.08960 [pdf] - 1890376
Precision laser-based measurements of the single electron response of
SPCs for the NEWS-G light dark matter search experiment
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Bard, J. -P.;
Brossard, A.;
Chapellier, M.;
Clark, M.;
Crawford, S.;
Corcoran, E. C.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Giroux, G.;
Gorel, P.;
Gros, M.;
Gros, P.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Knights, P.;
Langrock, S.;
Lautridou, P.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Nikolopoulos, K.;
Piquemal, F.;
Piro, M. -C.;
Santos, D.;
Savvidis, G.;
Savvidis, I.;
Fernandez, F. Vazquez de Sola;
Vidal, M.;
Zampaolo, M.
Submitted: 2019-02-24
Spherical Proportional Counters (SPCs) are a novel gaseous detector
technology employed by the NEWS-G low-mass dark matter search experiment for
their high sensitivity to single electrons from ionization. In this paper, we
report on the first characterization of the single electron response of SPCs
with unprecedented precision, using a UV-laser calibration system. The
experimental approach and analysis methodology are presented along with various
direct applications for the upcoming next phase of the experiment at SNOLAB.
These include the continuous monitoring of the detector response and electron
drift properties during dark matter search runs, as well as the experimental
measurement of the trigger threshold efficiency. We measure a mean ionization
energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$
for 2.8 keV X-rays, and demonstrate the feasibility of performing similar
precision measurements at sub-keV energies for future gas mixtures to be used
for dark matter searches at SNOLAB.
[3]
oai:arXiv.org:1711.07301 [pdf] - 1598281
Cathode signal in a TPC directional detector: implementation and
validation measuring the drift velocity
Submitted: 2017-11-20
Low-pressure gaseous TPCs are well suited detectors to correlate the
directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in
addition to providing a measure of the energy deposition due to the elastic
scattering of a DM particle on a nucleus in the target gas, they allow for the
reconstruction of the track of the recoiling nucleus. In order to exclude the
background events originating from radioactive decays on the surfaces of the
detector materials within the drift volume, efforts are ongoing to precisely
localize the track nuclear recoil in the drift volume along the axis
perpendicular to the cathode plane. We report here the implementation of the
measure of the signal induced on the cathode by the motion of the primary
electrons toward the anode in a MIMAC chamber. As a validation, we performed an
independent measurement of the drift velocity of the electrons in the
considered gas mixture, correlating in time the cathode signal with the measure
of the arrival times of the electrons on the anode.
[4]
oai:arXiv.org:1706.04934 [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at
the LSM
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Asner, D.;
Bard, J. -P.;
Brossard, A.;
Cai, B.;
Chapellier, M.;
Clark, M.;
Corcoran, E. C.;
Dandl, T.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Gorel, P.;
Gros, M.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Navick, X. -F.;
Papaevangelou, T.;
Piquemal, F.;
Roth, S.;
Santos, D.;
Savvidis, I.;
Ulrich, A.;
Fernandez, F. Vazquez de Sola;
Zampaolo, M.
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection
experiment using Spherical Proportional Counters (SPCs) with light noble gases
to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report
the results from the first physics run taken at the Laboratoire Souterrain de
Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a
mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total
exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the
spin-independent WIMP-nucleon scattering cross-section in the
sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times
\mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5
$\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are
promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to
be installed at SNOLAB by summer 2018.
[5]
oai:arXiv.org:1504.05865 [pdf] - 1579629
First detection of tracks of radon progeny recoils by MIMAC
Riffard, Q.;
Santos, D.;
Bosson, G.;
Bourrion, O.;
Descombes, T.;
Fourel, C.;
Guillaudin, O.;
Muraz, J. -F.;
Colas, P.;
Ferrer-Ribas, E.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Lebreton, L.;
Maire, D.
Submitted: 2015-04-22, last modified: 2017-06-20
The MIMAC experiment is a $\mu$-TPC matrix project for directional dark
matter search. Directional detection is a strategy based on the measurement of
the WIMP flux anisotropy due to the solar system motion with respect to the
dark matter halo. The main purpose of MIMAC project is the measurement of the
energy and the direction of nuclear recoils in 3D produced by elastic
scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the
Modane underground laboratory. In this paper, we report the first ionization
energy and 3D track observations of nuclear recoils produced by the radon
progeny. This measurement shows the capability of the MIMAC detector and opens
the possibility to explore the low energy recoil directionality signature.
[6]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[7]
oai:arXiv.org:1607.08765 [pdf] - 1446365
Directional detection of Dark Matter with the MIcro-tpc MAtrix of
Chambers
Couturier, C.;
Guillaudin, O.;
Naraghi, F.;
Riffard, Q.;
Santos, D.;
Sauzet, N.;
Colas, P.;
Ribas, E. Ferrer;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Zhou, N.
Submitted: 2016-07-29
Particles weakly interacting with ordinary matter, with an associated mass of
the order of an atomic nucleus (WIMPs), are plausible candidates for Dark
Matter. The direct detection of an elastic collision of a target nuclei induced
by one of these WIMPs has to be discriminated from the signal produced by the
neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc
MAtrix of Chambers) collaboration has developed an original prototype detector
which combines a large pixelated Micromegas coupled with a fast,
self-triggering, electronics. Aspects of the two-chamber module in operation in
the Modane Underground Laboratory are presented: calibration, characterization
of the $^{222}$Rn progeny. A new test bench combining a MIMAC chamber with the
COMIMAC portable quenching line has been set up to characterize the 3D tracks
of low energy ions in the MIMAC gas mixture: the preliminary results thereof
are presented. Future steps are briefly discussed.
[8]
oai:arXiv.org:1602.01738 [pdf] - 1483260
MIMAC low energy electron-recoil discrimination measured with fast
neutrons
Riffard, Q.;
Santos, D.;
Guillaudin, O.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Descombes, T.;
Muraz, J. -F.;
Lebreton, L.;
Maire, D.;
Colas, P.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Brunner, J.;
Tao, C.
Submitted: 2016-02-04, last modified: 2016-07-04
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter
detector project. Direct dark matter experiments need a high level of
electron/recoil discrimination to search for nuclear recoils produced by
WIMP-nucleus elastic scattering. In this paper, we proposed an original method
for electron event rejection based on a multivariate analysis applied to
experimental data acquired using monochromatic neutron fields. This analysis
shows that a $10^5$ rejection power is reachable for electron/recoil
discrimination. Moreover, the efficiency was estimated by a Monte-Carlo
simulation showing that a 105 electron rejection power is reached with a
$86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range
and $94.67\pm0.19$\% considering a 5~keV lower threshold.
[9]
oai:arXiv.org:1403.6592 [pdf] - 873816
Impact of particles on the Planck HFI detectors: Ground-based
measurements and physical interpretation
Catalano, A.;
Ade, P.;
Atik, Y.;
Benoit, A.;
Bréele, E.;
Bock, J. J.;
Camus, P.;
Chabot, M.;
Charra, M.;
Crill, B. P.;
Coron, N.;
Coulais, A.;
Désert, F. -X.;
Fauvet, L.;
Giraud-Héraud, Y.;
Guillaudin, O.;
Holmes, W.;
Jones, W. C.;
Lamarre, J. -M.;
Macías-Pérez, J.;
Martinez, M.;
Miniussi, A.;
Monfardini, A.;
Pajot, F.;
Patanchon, G.;
Pelissier, A.;
Piat, M.;
Puget, J. -L.;
Renault, C.;
Rosset, C.;
Santos, D.;
Sauvé, A.;
Spencer, L. D.;
Sudiwala, R.
Submitted: 2014-03-26, last modified: 2014-09-02
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from
August 2009 to January 2012. Its noise and sensitivity performance were
excellent, but the rate of cosmic ray impacts on the HFI detectors was
unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane
produced transient signals in the data (glitches) with a wide range of
characteristics. A study of cosmic ray impacts on the HFI detector modules has
been undertaken to categorize and characterize the glitches, to correct the HFI
time-ordered data, and understand the residual effects on Planck maps and data
products. This paper presents an evaluation of the physical origins of glitches
observed by the HFI detectors. In order to better understand the glitches
observed by HFI in flight, several ground-based experiments were conducted with
flight-spare HFI bolometer modules. The experiments were conducted between 2010
and 2013 with HFI test bolometers in different configurations using varying
particles and impact energies. The bolometer modules were exposed to 23 MeV
protons from the Orsay IPN TANDEM accelerator, and to $^{241}$Am and $^{244}$Cm
$\alpha$-particle and $^{55}$Fe radioactive X-ray sources. The calibration data
from the HFI ground-based preflight tests were used to further characterize the
glitches and compare glitch rates with statistical expectations under
laboratory conditions. Test results provide strong evidence that the dominant
family of glitches observed in flight are due to cosmic ray absorption by the
silicon die substrate on which the HFI detectors reside. Glitch energy is
propagated to the thermistor by ballistic phonons, while there is also a
thermal diffusion contribution. The implications of these results for future
satellite missions, especially those in the far-infrared to sub-millimetre and
millimetre regions of the electromagnetic spectrum, are discussed.
[10]
oai:arXiv.org:1403.5639 [pdf] - 800803
Characterization and Physical Explanation of Energetic Particles on
Planck HFI Instrument
Catalano, A.;
Ade, P.;
Atik, Y.;
Benoit, A.;
Bréele, E.;
Bock, J. J.;
Camus, P.;
Charra, M.;
Crill, B. P.;
Coron, N.;
Coulais, A.;
Désert, F. -X.;
Fauvet, L.;
Giraud-Héraud, Y.;
Guillaudin, O.;
Holmes, W.;
Jones, W. C.;
Lamarre, J. -M.;
Macías-Pérez, J.;
Martinez, M.;
Miniussi, A.;
Monfardini, A.;
Pajot, F.;
Patanchon, G.;
Pelissier, A.;
Piat, M.;
Puget, J. -L.;
Renault, C.;
Rosset, C.;
Santos, D.;
Sauvé, A.;
Spencer, L.;
Sudiwala, R.
Submitted: 2014-03-22
The Planck High Frequency Instrument (HFI) has been surveying the sky
continuously from the second Lagrangian point (L2) between August 2009 and
January 2012. It operates with 52 high impedance bolometers cooled at 100mK in
a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but
strong coupling with cosmic radiation. At L2, the particle flux is about 5
$cm^{-2} s^{-1}$ and is dominated by protons incident on the spacecraft.
Protons with an energy above 40MeV can penetrate the focal plane unit box
causing two different effects: glitches in the raw data from direct interaction
of cosmic rays with detectors (producing a data loss of about 15% at the end of
the mission) and thermal drifts in the bolometer plate at 100mK adding
non-gaussian noise at frequencies below 0.1Hz. The HFI consortium has made
strong efforts in order to correct for this effect on the time ordered data and
final Planck maps. This work intends to give a view of the physical explanation
of the glitches observed in the HFI instrument in-flight. To reach this goal,
we performed several ground-based experiments using protons and $\alpha$
particles to test the impact of particles on the HFI spare bolometers with a
better control of the environmental conditions with respect to the in-flight
data. We have shown that the dominant part of glitches observed in the data
comes from the impact of cosmic rays in the silicon die frame supporting the
micro-machinced bolometric detectors propagating energy mainly by ballistic
phonons and by thermal diffusion. The implications of these results for future
satellite missions will be discussed.
[11]
oai:arXiv.org:1305.2360 [pdf] - 776422
In situ measurement of the electron drift velocity for upcoming
directional Dark Matter detectors
Billard, J.;
Mayet, F.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Richer, J. P.;
Riffard, Q.;
Santos, D.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-05-10, last modified: 2014-01-28
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection and it requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence needed as it is a way to avoid bias in the 3D track reconstruction. We
present a dedicated method for the measurement of the electron drift velocity
with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3.
The latter has been chosen for the MIMAC detector as we expect that adding CHF3
to pure CF4 will lower the electron drift velocity. This is a key point for
directional Dark Matter as the track sampling along the drift field will be
improved while keeping almost the same Fluorine content of the gas mixture. We
show that the drift velocity at 50 mbar is reduced by a factor of about 5 when
adding 30% of CHF3.
[12]
oai:arXiv.org:1401.1009 [pdf] - 766735
Measurement of the electron drift velocity for directional dark matter
detectors
Mayet, F.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Richer, J. P.;
Riffard, Q.;
Santos, D.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2014-01-06
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection. It requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence a way to avoid bias in the 3D track reconstruction. We present a
dedicated method for the measurement of the electron drift velocity with the
MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm
CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the
electron drift velocity while keeping almost the same Fluorine content of the
gas mixture.
[13]
oai:arXiv.org:1311.0616 [pdf] - 1180445
MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional
detection
Santos, D.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Lamblin, J.;
Mayet, F.;
Muraz, J. F.;
Richer, J. P.;
Riffard, Q.;
Lebreton, L.;
Maire, D.;
Busto, J.;
Brunner, J.;
Fouchez, D.
Submitted: 2013-11-04
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from neutrons, the ultimate background
for dark matter direct detection. This strategy requires both a precise
measurement of the energy down to a few keV and 3D reconstruction of tracks
down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has
developed in the last years an original prototype detector based on the direct
coupling of large pixelized micromegas with a special developed fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The first bi-chamber prototype has been installed at
Modane, underground laboratory in June 2012. The first undergournd background
events, the gain stability and calibration are shown. The first spectrum of
nuclear recoils showing 3D tracks coming from the radon progeny is presented.
[14]
oai:arXiv.org:1306.4173 [pdf] - 681293
Dark Matter directional detection with MIMAC
Riffard, Q.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Mayet, F.;
Muraz, J. -F.;
Richer, J. -P.;
Santos, D.;
Lebreton, L.;
Maire, D.;
Busto, J.;
Brunner, J.;
Fouchez, D.
Submitted: 2013-06-18
Directional detection is a promising direct Dark Matter (DM) search strategy.
The angular distribution of the nuclear recoil tracks from WIMP events should
present an anisotropy in galactic coordinates. This strategy requires both a
measurement of the recoil energy with a threshold of about 5 keV and 3D recoil
tracks down to few millimeters.
The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is
being developed. In June 2012, a bi-chamber prototype was installed at the LSM
(Laboratoire Souterrain de Modane). A preliminary analysis of the first four
months data taking allowed, for the first time, the observation of recoils from
the $\mathrm{^{222}Rn}$ progeny.
[15]
oai:arXiv.org:1304.2255 [pdf] - 1165808
MIMAC: A micro-tpc matrix for dark matter directional detection
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, C.;
Guillaudin, O.;
Lamblin, J.;
Muraz, J. F.;
Mayet, F.;
Richer, J. P.;
Riffard, Q.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-04-08
The dark matter directional detection opens a new field in cosmology bringing
the possibility to build a map of nuclear recoils that would be able to explore
the galactic dark matter halo giving access to a particle characterization of
such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers)
collaboration has developed in the last years an original prototype detector
based on the direct coupling of large pixelized micromegas with a devoted fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The discovery potential of this search strategy is
discussed and illustrated. In June 2012, the first bi-chamber prototype has
been installed at Modane Underground Laboratory (LSM) and the first underground
background events, the gain stability and calibration are shown.
[16]
oai:arXiv.org:1110.4579 [pdf] - 440726
Development and validation of a 64 channel front end ASIC for 3D
directional detection for MIMAC
Submitted: 2011-10-20, last modified: 2011-11-10
A front end ASIC has been designed to equip the {\mu}TPC prototype developed
for the MIMAC project, which requires 3D reconstruction of low energy particle
tracks in order to perform directional detection of galactic Dark Matter. Each
ASIC is able to monitor 64 strips of pixels and provides the "Time Over
Threshold" information for each of those. These 64 digital informations,
sampled at a rate of 50 MHz, can be transferred at 400MHz by eight LVDS serial
links. Eight ASIC were validated on a 2x256 strips of pixels prototype.
[17]
oai:arXiv.org:1111.1566 [pdf] - 435178
MIMAC: A micro-tpc matrix project for directional detection of dark
matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-11-07
Directional detection of non-baryonic DarkMatter is a promising search
strategy for discriminating WIMP events from background ones. This strategy
requires both a measurement of the recoil energy down to a few keV and 3D
reconstruction of tracks down to a few mm. The MIMAC project, based on a
micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first
results of a chamber prototype of this matrix, on low energy nuclear recoils
(1H and 19F) obtained with mono-energetic neutron fields are presented. The
discovery potential of this search strategy is illustrated by a realistic case
accessible to MIMAC.
[18]
oai:arXiv.org:1110.4348 [pdf] - 437252
Data acquisition electronics and reconstruction software for real time
3D track reconstruction within the MIMAC project
Submitted: 2011-10-19, last modified: 2011-11-02
Directional detection of non-baryonic Dark Matter requires 3D reconstruction
of low energy nuclear recoils tracks. A gaseous micro-TPC matrix, filled with
either 3He, CF4 or C4H10 has been developed within the MIMAC project. A
dedicated acquisition electronics and a real time track reconstruction software
have been developed to monitor a 512 channel prototype. This autotriggered
electronic uses embedded processing to reduce the data transfer to its useful
part only, i.e. decoded coordinates of hit tracks and corresponding energy
measurements. An acquisition software with on-line monitoring and 3D track
reconstruction is also presented.
[19]
oai:arXiv.org:1109.2002 [pdf] - 478078
Dedicated front-end and readout electronics developments for real time
3D directional detection of dark matter with MIMAC
Submitted: 2011-09-09, last modified: 2011-09-19
A complete dedicated electronics, from front-end to back-end, was developed
to instrument a MIMAC prototype. A front end ASIC able to monitor 64 strips of
pixels and to provide their individual "Time Over Threshold" information has
been designed. An associated acquisition electronics and a real time track
reconstruction software have been developed to monitor a 512 channel prototype.
This auto-triggered electronic uses embedded processing to reduce the data
transfer to its useful part only, i.e. decoded coordinates of hit tracks and
corresponding energy measurements. The electronic designs, acquisition software
and the results obtained are presented.
[20]
oai:arXiv.org:1109.1675 [pdf] - 1083919
Micromegas detector developments for MIMAC
Ferrer-Ribas, E.;
Attié, D.;
Calvet, D.;
Colas, P.;
Druillole, F.;
Giomataris, Y.;
Iguaz, F. J.;
Mols, J. P.;
Pancin, J.;
Papaevangelou, T.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC. The recent Micromegas efforts towards building a large size
detector will be described, in particular the characterization measurements of
a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout
plane. Track reconstruction with alpha particles will be shown.
[21]
oai:arXiv.org:1102.3265 [pdf] - 399526
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-02-16
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with CF4 and CHF3. The first results on low energy nuclear recoils (H, F)
obtained with a low mono-energetic neutron field are presented. The discovery
potential of this search strategy is discussed and illustrated by a realistic
case accessible to MIMAC.
[22]
oai:arXiv.org:1012.1166 [pdf] - 955699
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Allaoua, A.;
Golabek, C.;
Lebreton, L.
Submitted: 2010-12-06
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H
and 19F) obtained with a low mono-energetic neutron field are presented. The
discovery potential of this search strategy is discussed and illustrated by a
realistic case accessible to MIMAC.
[23]
oai:arXiv.org:1008.4712 [pdf] - 228441
Directional detection of non-baryonic dark matter with MIMAC
Grignon, C.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Ferrer, E.;
Giomataris, I.;
Mols, J. P.
Submitted: 2010-08-27, last modified: 2010-09-17
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating genuine WIMP events from background ones. However,
carrying out such a strategy requires both a precise measurement of the energy
down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve
this goal, the MIMAC project has been developed: it is based on a gaseous
micro-TPC matrix, filled with 3He, CF4 and/or C4H10. Firsts results of low
energy nuclei recoils obtained with a low energy neutron field are presented.
[24]
oai:arXiv.org:1006.1335 [pdf] - 226516
Data acquisition electronics and reconstruction software for directional
detection of Dark Matter with MIMAC
Submitted: 2010-06-07
Directional detection of galactic Dark Matter requires 3D reconstruction of
low energy nuclear recoils tracks. A dedicated acquisition electronics with
auto triggering feature and a real time track reconstruction software have been
developed within the framework of the MIMAC project of detector. This
auto-triggered acquisition electronic uses embedded processing to reduce data
transfer to its useful part only, i.e. decoded coordinates of hit tracks and
corresponding energy measurements. An acquisition software with on-line
monitoring and 3D track reconstruction is also presented.
[25]
oai:arXiv.org:1004.2365 [pdf] - 148607
Directional detection of Dark Matter
Submitted: 2010-04-14
Directional detection of galactic Dark Matter is a promising search strategy
for discriminating genuine WIMP events from background ones. However, to take
full advantage of this powerful detection method, one need to be able to
extract information from an observed recoil map to identify a WIMP signal. We
present a comprehensive formalism, using a map-based likelihood method allowing
to recover the main incoming direction of the signal, thus proving its galactic
origin, and the corresponding significance. Constraints are then deduced in the
(sigma_n, m_chi) plane.
[26]
oai:arXiv.org:0912.0186 [pdf] - 902594
Development of a front end ASIC for Dark Matter directional detection
with MIMAC
Submitted: 2009-12-01, last modified: 2010-04-13
A front end ASIC (BiCMOS-SiGe 0.35 \mum) has been developed within the
framework of the MIMAC detector project, which aims at directional detection of
non-baryonic Dark Matter. This search strategy requires 3D reconstruction of
low energy (a few keV) tracks with a gaseous \muTPC. The development of this
front end ASIC is a key point of the project, allowing the 3D track
reconstruction. Each ASIC monitors 16 strips of pixels with charge
preamplifiers and their time over threshold is provided in real time by current
discriminators via two serializing LVDS links working at 320 MHz. The charge is
summed over the 16 strips and provided via a shaper. These specifications have
been chosen in order to build an auto triggered electronics. An acquisition
board and the related software were developed in order to validate this
methodology on a prototype chamber. The prototype detector presents an anode
where 2 x 96 strips of pixels are monitored.
[27]
oai:arXiv.org:1001.2983 [pdf] - 32880
Directional detection of galactic Dark Matter
Mayet, F.;
Billard, J.;
Bernard, G.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Koumeir, C.;
Richer, J. P.;
Santos, D.;
Colas, P.;
Ferer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2010-01-18
Directional detection of galactic Dark Matter is a promising search strategy
for discriminating geniune WIMP events from background ones. We present
technical progress on gaseous detectors as well as recent phenomenological
studies, allowing the design and construction of competitive experiments.
[28]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[29]
oai:arXiv.org:0909.0654 [pdf] - 901600
A prototype of a directional detector for non-baryonic dark matter
search: MIMAC (Micro-TPC Matrix of Chambers)
Grignon, C.;
Bernard, G.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Koumeir, C.;
Mayet, F.;
Santos, D.;
Colas, P.;
Ferrer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2009-09-03, last modified: 2009-10-30
We have developed a micro-tpc using a pixelized bulk micromegas coupled to
dedicated acquisition electronics as a read-out allowing to reconstruct the
three dimensional track of a few keV recoils. The prototype has been tested
with the Amande facility at the IRSN-Cadarache providing monochromatic
neutrons. The first results concerning discrimination of a few keV electrons
and proton recoils are presented.
[30]
oai:arXiv.org:0905.4800 [pdf] - 24752
Dark matter directional detection with MIMAC
Grignon, C.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Koumeir, C.;
Mayet, F.;
Santos, D.;
Colas, P.;
Ferrer, E.;
Giomataris, I.
Submitted: 2009-05-29
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for
direct detection of non-baryonic dark matter. Measurement of both track and
ionization energy will allow the electron-recoil discrimination, while access
to the directionnality of the tracks will open a unique way to distinguish a
geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV
electrons are presented as a proof of concept.
[31]
oai:arXiv.org:0905.4654 [pdf] - 24724
Micromegas micro-TPC for direct Dark Matter search with MIMAC
Submitted: 2009-05-28
The MIMAC project is a multi-chamber detector for Dark Matter search, aiming
at measuring both track and ionization with a matrix of micromegas micro-TPC
filled with He3 and CF4. Recent experimental results on the first measurements
of the Helium quenching factor at low energy (1 keV recoil) are presented,
together with the first simulation of the track reconstruction. Recontruction
of track of alpha from Radon impurities is shown as a first proof of concept.
[32]
oai:arXiv.org:0905.4697 [pdf] - 250730
MIMAC : a micro-TPC detector for non-baryonic dark matter search
Submitted: 2009-05-28
The MIMAC project is multi-chamber detector for Dark Matter search, aiming at
measuring both track and ionization with a matrix of micromegas micro-TPC
filled with He3 and CF4. Recent experimental results on the first measurements
of the Helium quenching factor at low energy (1 keV recoil) are presented.
[33]
oai:arXiv.org:0904.1667 [pdf] - 23251
Low energy measurements with Helium Micromegas micro-TPC
Submitted: 2009-04-10
The measurement of the ionization produced by particles in a medium presents
a great interest in several fields from metrology to particule physics and
cosmology. The ionization quenching factor is defined as the fraction of energy
released by ionisation by a recoil in a medium compared with its kinetic
energy. At low energy, in the range of a few keV, the ionization falls rapidly
and systematic measurement are needed. We have developped an experimental setup
devoted to the measurement of low energy (keV) ionization quenching factor for
the MIMAC project. The ionization produced in the gas has been measured with a
Micromegas detector filled with Helium gas mixture.
[34]
oai:arXiv.org:0904.1642 [pdf] - 250715
MIMAC : Detection of low energy recoils for Dark Matter search
Submitted: 2009-04-10
The MIMAC project is based on a matrix of Micro Time Projection Chambers
(micro-TPC) for Dark Matter search, filled with He3 or CF4 and using ionization
and tracks. The first measurement of the energy resolution of this micro-TPC is
presented as well as its low threshold
[35]
oai:arXiv.org:0810.1137 [pdf] - 17161
Ionization Quenching Factor Measurement of Helium 4
Submitted: 2008-10-07
The ionization quenching factor (IQF) is defined as the fraction of energy
released by a recoil in a medium through ionization compared with its total
kinetic energy. At low energies, in the range of a few keV, the ionization
produced in a medium falls rapidly and systematic measurements are needed. We
report measurements carried out at such low energies as a function of the
pressure in He4 at 350, 700, 1000 and 1300 mbar. In order to produce a nucleus
moving with a controlled energy in the detection volume, we have developed an
Electron Cyclotron Resonance Ion Source (ECRIS) coupled to an ionization
chamber by a differential pumping. The quenching factor of He4 has been
measured for the first time down to 1 keV recoil energies. An important
deviation with respect to the phenomenological calculations has been found
allowing an estimation of the scintillation produced in He4 as a function of
pressure. The variation of the IQF as a function of the percentage of
isobutane, used as quencher, is also presented.
[36]
oai:arXiv.org:astro-ph/0703310 [pdf] - 90119
MIMAC : A Micro-TPC Matrix of Chambers for direct detection of Wimps
Submitted: 2007-03-13
The project of a micro-TPC matrix of chambers of He3 and CF4 for direct
detection of non-baryonic dark matter is outlined. The privileged properties of
He3 are highlighted. The double detection (ionization - projection of tracks)
will assure the electron-recoil discrimination. The complementarity of MIMAC
for supersymmetric dark matter search with respect to other experiments is
illustrated.The modular character of the detector allows to have different
gases to get A-dependence. The pressure degreee of freedom gives the
possibility to work at high and low pressures. The low pressure regime gives
the possibility to get the directionality of the tracks. The first measurements
of ionization at very few keVs for He3 in CF4 gas are described.
[37]
oai:arXiv.org:astro-ph/0701230 [pdf] - 1510614
MIMAC-He3 : MIcro-tpc MAtrix of Chambers of He3
Submitted: 2007-01-09
The project of a micro-TPC matrix of chambers of He3 for direct detection of
non-baryonic dark matter is outlined. The privileged properties of He3 are
highlighted. The double detection (ionization - projection of tracks) will
assure the electron-recoil discrimination. The complementarity of MIMAC-He3 for
supersymmetric dark matter search with respect to other experiments is
illustrated. The modular character of the detector allows to have different
gases to get A-dependence. The pressure degreee of freedom gives the
possibility to work at high and low pressure. The low pressure regime gives the
possibility to get the directionality of the tracks. The first measurements of
ionization at very few keVs for He3 in He4 gas are described.