Normalized to: Guerard, C.
[2]
oai:arXiv.org:astro-ph/9801176 [pdf] - 100025
A Decommissioned LHC Model Magnet as an Axion Telescope
Zioutas, K.;
Aalseth, C. E.;
Abriola, D.;
Avignone, F. T.;
Brodzinski, R. L.;
Collar, J. I.;
Creswick, R.;
Di Gregorio, D. E.;
Farach, H.;
Gattone, A. O.;
Guerard, C. K.;
Hasenbalg, F.;
Hasinoff, M.;
Huck, H.;
Liolios, A.;
Miley, H. S.;
Morales, A.;
Morales, J.;
Nikas, D.;
Nussinov, S.;
Ortiz, A.;
Savvidis, E.;
Scopel, S.;
Sievers, P.;
Villar, J. A.;
Walckiers, L.
Submitted: 1998-01-18, last modified: 1999-01-22
The 8.4 Tesla, 10 m long transverse magnetic field of a twin aperture LHC
bending magnet can be utilized as a macroscopic coherent solar axion-to-photon
converter. Numerical calculations show that the integrated time of alignment
with the Sun would be 33 days per year with the magnet on a tracking table
capable of $\pm 5^o$ in the vertical direction and $\pm 40^o$ in the horizontal
direction. The existing lower bound on the axion-to-photon coupling constant
can be improved by a factor between 50 and 100 in 3 years, i.e.,
$g_{a\gamma\gamma} \lesssim 9\cdot 10^{-11} GeV^{-1}$ for axion masses
$\lesssim$ 1 eV. This value falls within the existing open axion mass window.
The same set-up can simultaneously search for low- and high-energy celestial
axions, or axion-like particles, scanning the sky as the Earth rotates and
orbits the Sun.
[3]
oai:arXiv.org:astro-ph/9809018 [pdf] - 102722
Search for an annual modulation of dark-matter signals with a germanium
spectrometer at the Sierra Grande Laboratory
Abriola, D.;
Avignone, F. T.;
Brodzinski, R. L.;
Collar, J. I.;
Di Gregorio, D. E.;
Farach, H. A.;
Garcia, E.;
Gattone, A. O.;
Guerard, C. K.;
Hasenbalg, F.;
Huck, H.;
Miley, H. S.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Reeves, J. H.;
Salinas, A.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 1998-09-02, last modified: 1998-09-14
Data collected during three years with a germanium spectrometer at the Sierra
Grande underground laboratory have been analyzed for distinctive features of
annual modulation of the signal induced by WIMP dark matter candidates. The
main motivation for this analysis was the recent suggestion by the DAMA/NaI
Collaboration that a yearly modulation signal could not be rejected at the 90%
confidence level when analyzing data obtained with a high-mass low-background
scintillator detector. We performed two different analyses of the data: First,
the statistical distribution of modulation-significance variables (expected
from an experiment running under the conditions of Sierra Grande) was compared
with the same variables obtained from the data. Second, the data were analyzed
in energy bins as an independent check of the first result and to allow for the
possibility of a crossover in the expected signal. In both cases no
statistically significant deviation from the null result was found, which could
support the hypothesis that the data contain a modulated component. A plot is
also presented to enable the comparison of these results to those of the DAMA
collaboration.
[4]
oai:arXiv.org:astro-ph/9708008 [pdf] - 98186
Experimental Search for Solar Axions via Coherent Primakoff Conversion
in a Germanium Spectrometer
Avignone, F. T.;
Abriola, D.;
Brodzinski, R. L.;
Collar, J. I.;
Creswick, R. J.;
DiGregorio, D. E.;
Farach, H. A.;
Gattone, A. O.;
Guerard, C. K.;
Hasenbalg, F.;
Huck, H.;
Miley, H. S.;
Morales, A.;
Morales, J.;
Nussinov, S.;
de Solorzano, A. Ortiz;
Reeves, J. H.;
Villar, J. A.;
Zioutas, K.
Submitted: 1997-08-01
Results are reported of an experimental search for the unique, rapidly
varying temporal pattern of solar axions coherently converting into photons via
the Primakoff effect in a single crystal germanium detector. This conversion is
predicted when axions are incident at a Bragg angle with a crystalline plane.
The analysis of approximately 1.94 kg.yr of data from the 1 kg DEMOS detector
in Sierra Grande, Argentina, yields a new laboratory bound on axion-photon
coupling of $g_{a\gamma \gamma} < 2.7\cdot 10^{-9}$ GeV$^{-1}$, independent of
axion mass up to ~ 1 keV.
[5]
oai:arXiv.org:hep-ex/9707036 [pdf] - 113380
A Water Tank Cerenkov Detector for Very High Energy Astroparticles
Bauleo, P.;
Etchegoyen, A.;
Niello, J. O. Fernandez;
Ferrero, A. M. J.;
Filevich, A.;
Guerard, C. K.;
Hasenbalg, F.;
Mostafa, M. A.;
Ravignani, D.;
Martino, J. Rodriguez
Submitted: 1997-07-24
Extensive airshower detection is an important issue in current astrophysics
endeavours. Surface arrays detectors are a common practice since they are easy
to handle and have a 100% duty cycle. In this work we present an experimental
study of the parameters relevant to the design of a water Cerenkov detector for
high energy airshowers. This detector is conceived as part of the surface array
of the Pierre Auger Project, which is expected to be sensitive to ultra high
energy cosmic rays. In this paper we focus our attention in the geometry of the
tank and its inner liner material, discussing pulse shapes and charge
collections.