Normalized to: Grundy, T.
[1]
oai:arXiv.org:1909.01183 [pdf] - 1953899
The Solar Orbiter SPICE instrument -- An extreme UV imaging spectrometer
Anderson, M.;
Appourchaux, T.;
Auchère, F.;
Cuadrado, R. Aznar;
Barbay, J.;
Baudin, F.;
Beardsley, S.;
Bocchialini, K.;
Borgo, B.;
Bruzzi, D.;
Buchlin, E.;
Burton, G.;
Blüchel, V.;
Caldwell, M.;
Caminade, S.;
Carlsson, M.;
Curdt, W.;
Davenne, J.;
Davila, J.;
DeForest, C. E.;
Del Zanna, G.;
Drummond, D.;
Dubau, J.;
Dumesnil, C.;
Dunn, G.;
Eccleston, P.;
Fludra, A.;
Fredvik, T.;
Gabriel, A.;
Giunta, A.;
Gottwald, A.;
Griffin, D.;
Grundy, T.;
Guest, S.;
Gyo, M.;
Haberreiter, M.;
Hansteen, V.;
Harrison, R.;
Hassler, D. M.;
Haugan, S. V. H.;
Howe, C.;
Janvier, M.;
Klein, R.;
Koller, S.;
Kucera, T. A.;
Kouliche, D.;
Marsch, E.;
Marshall, A.;
Marshall, G.;
Matthews, S. A.;
McQuirk, C.;
Meining, S.;
Mercier, C.;
Morris, N.;
Morse, T.;
Munro, G.;
Parenti, S.;
Pastor-Santos, C.;
Peter, H.;
Pfiffner, D.;
Phelan, P.;
Philippon, A.;
Richards, A.;
Rogers, K.;
Sawyer, C.;
Schlatter, P.;
Schmutz, W.;
Schühle, U.;
Shaughnessy, B.;
Sidher, S.;
Solanki, S. K.;
Speight, R.;
Spescha, M.;
Szwec, N.;
Tamiatto, C.;
Teriaca, L.;
Thompson, W.;
Tosh, I.;
Tustain, S.;
Vial, J. -C.;
Walls, B.;
Waltham, N.;
Wimmer-Schweingruber, R.;
Woodward, S.;
Young, P.;
De Groof, A.;
Pacros, A.;
Williams, D.;
Müller, D.
Submitted: 2019-09-03
The Spectral Imaging of the Coronal Environment (SPICE) instrument is a
high-resolution imaging spectrometer operating at extreme ultraviolet (EUV)
wavelengths. In this paper, we present the concept, design, and pre-launch
performance of this facility instrument on the ESA/NASA Solar Orbiter mission.
The goal of this paper is to give prospective users a better understanding of
the possible types of observations, the data acquisition, and the sources that
contribute to the instrument's signal. The paper discusses the science
objectives, with a focus on the SPICE-specific aspects, before presenting the
instrument's design, including optical, mechanical, thermal, and electronics
aspects. This is followed by a characterisation and calibration of the
instrument's performance. The paper concludes with descriptions of the
operations concept and data processing. The performance measurements of the
various instrument parameters meet the requirements derived from the mission's
science objectives. The SPICE instrument is ready to perform measurements that
will provide vital contributions to the scientific success of the Solar Orbiter
mission.
[2]
oai:arXiv.org:1508.02333 [pdf] - 1264202
The Mid-Infrared Instrument for JWST, II: Design and Build
Wright, G. S.;
Wright, David;
Goodson, G. B.;
Rieke, G. H.;
Aitink-Kroes, Gabby;
Amiaux, J.;
Aricha-Yanguas, Ana;
Azzolini, Ruyman;
Banks, Kimberly;
Barrado-Navascues, D.;
Belenguer-Davila, T.;
Bloemmart, J. A. D. L.;
Bouchet, Patrice;
Brandl, B. R.;
Colina, L.;
Detre, Ors;
Diaz-Catala, Eva;
Eccleston, Paul;
Friedman, Scott D.;
Garcia-Marin, Macarena;
Guedel, Manuel;
Glasse, Alistair;
Glauser, Adrian M.;
Greene, T. P.;
Groezinger, Uli;
Grundy, Tim;
Hastings, Peter;
Henning, Th.;
Hofferbert, Ralph;
Hunter, Faye;
Jessen, N. C.;
Justtanont, K.;
Karnik, Avinash R.;
Khorrami, Mori A.;
Krause, Oliver;
Labiano, Alvaro;
Lagage, P. -O.;
Langer, Ulrich;
Lemke, Dietrich;
Lim, Tanya;
Lorenzo-Alvarez, Jose;
Mazy, Emmanuel;
McGowan, Norman;
Meixner, M. E.;
Morris, Nigel;
Morrison, Jane E.;
Mueller, Friedrich;
Norgaard-Nielson, H. -U.;
Olofsson, Goeran;
O'Sullivan, Brian;
Pel, J. -W.;
Penanen, Konstantin;
Petach, M. B.;
Pye, J. P.;
Ray, T. P.;
Renotte, Etienne;
Renouf, Ian;
Ressler, M. E.;
Samara-Ratna, Piyal;
Scheithauer, Silvia;
Schneider, Analyn;
Shaughnessy, Bryan;
Stevenson, Tim;
Sukhatme, Kalyani;
Swinyard, Bruce;
Sykes, Jon;
Thatcher, John;
Tikkanen, Tuomo;
van Dishoeck, E. F.;
Waelkens, C.;
Walker, Helen;
Wells, Martyn;
Zhender, Alex
Submitted: 2015-08-10
The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST)
provides measurements over the wavelength range 5 to 28.5 microns. MIRI has,
within a single 'package', four key scientific functions: photometric imaging,
coronagraphy, single-source low-spectral resolving power (R ~ 100)
spectroscopy, and medium-resolving power (R ~ 1500 to 3500) integral field
spectroscopy. An associated cooler system maintains MIRI at its operating
temperature of < 6.7 K. This paper describes the driving principles behind the
design of MIRI, the primary design parameters, and their realization in terms
of the 'as-built' instrument. It also describes the test program that led to
delivery of the tested and calibrated Flight Model to NASA in 2012, and the
confirmation after delivery of the key interface requirements.
[3]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.
[4]
oai:arXiv.org:0711.2281 [pdf] - 7046
High-excitation OH and H_2O lines in Markarian 231: the molecular
signatures of compact far-infrared continuum sources
Submitted: 2007-11-14, last modified: 2007-12-24
The ISO/LWS far-infrared spectrum of the ultraluminous galaxy Mkn 231 shows
OH and H_2O lines in absorption from energy levels up to 300 K above the ground
state, and emission in the [O I] 63 micron and [C II] 158 micron lines. Our
analysis shows that OH and H_2O are radiatively pumped by the far-infrared
continuum emission of the galaxy. The absorptions in the high-excitation lines
require high far-infrared radiation densities, allowing us to constrain the
properties of the underlying continuum source. The bulk of the far-infrared
continuum arises from a warm (T_dust=70-100 K), optically thick
(tau_100micron=1-2) medium of effective diameter 200-400 pc. In our best-fit
model of total luminosity L_IR, the observed OH and H2O high-lying lines arise
from a luminous (L/L_IR~0.56) region with radius ~100 pc. The high surface
brightness of this component suggests that its infrared emission is dominated
by the AGN. The derived column densities N(OH)>~10^{17} cm^{-2} and
N(H_2O)>~6x10^{16} cm^{-2} may indicate XDR chemistry, although significant
starburst chemistry cannot be ruled out. The lower-lying OH, [C II] 158 micron,
and [O I] 63 micron lines arise from a more extended (~350 pc) starburst
region. We show that the [C II] deficit in Mkn 231 is compatible with a high
average abundance of C+ because of an extreme overall luminosity to gas mass
ratio. Therefore, a [C II] deficit may indicate a significant contribution to
the luminosity by an AGN, and/or by extremely efficient star formation.
[5]
oai:arXiv.org:astro-ph/0702725 [pdf] - 89779
The ISO LWS high resolution spectral survey towards Sagittarius B2
Submitted: 2007-02-27
A full spectral survey was carried out towards the Giant Molecular Cloud
complex, Sagittarius B2 (Sgr B2), using the ISO Long Wavelength Spectrometer
Fabry-Perot mode. This provided complete wavelength coverage in the range
47-196 um (6.38-1.53 THz) with a spectral resolution of 30-40 km/s. This is an
unique dataset covering wavelengths inaccessible from the ground. It is an
extremely important region of the spectrum as it contains both the peak of the
thermal emission from dust, and crucial spectral lines of key atomic (OI, CII,
OIII, NII and NIII) and molecular species (NH3, NH2, NH, H2O, OH, H3O+, CH,
CH2, C3, HF and H2D+). In total, 95 spectral lines have been identified and 11
features with absorption depth greater than 3 sigma remain unassigned. Most of
the molecular lines are seen in absorption against the strong continuum,
whereas the atomic and ionic lines appear in emission (except for absorption in
the OI 63 um and CII 158 um lines). Sgr B2 is located close to the Galactic
Centre and so many of the features also show a broad absorption profile due to
material located along the line of sight. A full description of the survey
dataset is given with an overview of each detected species and final line lists
for both assigned and unassigned features.
[6]
oai:arXiv.org:astro-ph/0605410 [pdf] - 82098
A far-infrared molecular and atomic line survey of the Orion KL region
Lerate, M. R.;
Barlow, M. J.;
Swinyard, B. M.;
Goicoechea, J. R.;
Cernicharo, J.;
Grundy, T. W.;
Lim, T. L.;
Polehampton, E. T.;
Baluteau, J. P.;
Viti, S.;
Yates, J.
Submitted: 2006-05-17
We have carried out a high spectral resolution line survey towards the Orion
Kleinmann-Low (KL) cluster from 44-188 um. The observations were taken with the
Long Wavelength Spectrometer (LWS) in Fabry-Perot mode, on board the Infrared
Space Observatory (ISO). A total of 152 lines are clearly detected and a
further 34 features are present as possible detections. The spectrum is
dominated by the molecular species H2O, OH and CO, along with [OI] and [CII]
lines from PDR or shocked gas and [OIII], [NIII] lines from the foreground M42
HII region. Several isotopic species, as well as NH3, are also detected. HDO
and H3O+ are tentatively detected for the first time in the far-infrared range
towards Orion-KL. A basic analysis of the line observations is carried out, by
comparing with previous measurements and published models and deriving
rotational temperatures and column densities in the case of the molecular
species. The complexity of the region requires more sophisticated models for
the interpretation of all the line observations.