Normalized to: Griffin, D.
[1]
oai:arXiv.org:1909.01183 [pdf] - 1953899
The Solar Orbiter SPICE instrument -- An extreme UV imaging spectrometer
Anderson, M.;
Appourchaux, T.;
Auchère, F.;
Cuadrado, R. Aznar;
Barbay, J.;
Baudin, F.;
Beardsley, S.;
Bocchialini, K.;
Borgo, B.;
Bruzzi, D.;
Buchlin, E.;
Burton, G.;
Blüchel, V.;
Caldwell, M.;
Caminade, S.;
Carlsson, M.;
Curdt, W.;
Davenne, J.;
Davila, J.;
DeForest, C. E.;
Del Zanna, G.;
Drummond, D.;
Dubau, J.;
Dumesnil, C.;
Dunn, G.;
Eccleston, P.;
Fludra, A.;
Fredvik, T.;
Gabriel, A.;
Giunta, A.;
Gottwald, A.;
Griffin, D.;
Grundy, T.;
Guest, S.;
Gyo, M.;
Haberreiter, M.;
Hansteen, V.;
Harrison, R.;
Hassler, D. M.;
Haugan, S. V. H.;
Howe, C.;
Janvier, M.;
Klein, R.;
Koller, S.;
Kucera, T. A.;
Kouliche, D.;
Marsch, E.;
Marshall, A.;
Marshall, G.;
Matthews, S. A.;
McQuirk, C.;
Meining, S.;
Mercier, C.;
Morris, N.;
Morse, T.;
Munro, G.;
Parenti, S.;
Pastor-Santos, C.;
Peter, H.;
Pfiffner, D.;
Phelan, P.;
Philippon, A.;
Richards, A.;
Rogers, K.;
Sawyer, C.;
Schlatter, P.;
Schmutz, W.;
Schühle, U.;
Shaughnessy, B.;
Sidher, S.;
Solanki, S. K.;
Speight, R.;
Spescha, M.;
Szwec, N.;
Tamiatto, C.;
Teriaca, L.;
Thompson, W.;
Tosh, I.;
Tustain, S.;
Vial, J. -C.;
Walls, B.;
Waltham, N.;
Wimmer-Schweingruber, R.;
Woodward, S.;
Young, P.;
De Groof, A.;
Pacros, A.;
Williams, D.;
Müller, D.
Submitted: 2019-09-03
The Spectral Imaging of the Coronal Environment (SPICE) instrument is a
high-resolution imaging spectrometer operating at extreme ultraviolet (EUV)
wavelengths. In this paper, we present the concept, design, and pre-launch
performance of this facility instrument on the ESA/NASA Solar Orbiter mission.
The goal of this paper is to give prospective users a better understanding of
the possible types of observations, the data acquisition, and the sources that
contribute to the instrument's signal. The paper discusses the science
objectives, with a focus on the SPICE-specific aspects, before presenting the
instrument's design, including optical, mechanical, thermal, and electronics
aspects. This is followed by a characterisation and calibration of the
instrument's performance. The paper concludes with descriptions of the
operations concept and data processing. The performance measurements of the
various instrument parameters meet the requirements derived from the mission's
science objectives. The SPICE instrument is ready to perform measurements that
will provide vital contributions to the scientific success of the Solar Orbiter
mission.
[2]
oai:arXiv.org:1606.06960 [pdf] - 1451285
The Australian Space Eye: studying the history of galaxy formation with
a CubeSat
Horton, Anthony;
Spitler, Lee;
Mathers, Naomi;
Petkovic, Michael;
Griffin, Douglas;
Barraclough, Simon;
Benson, Craig;
Dimitrijevic, Igor;
Lambert, Andrew;
Previte, Anthony;
Bowen, John;
Westerman, Solomon;
Puig-Suari, Jordi;
Reisenfeld, Sam;
Lawrence, Jon;
Zhelem, Ross;
Colless, Matthew;
Boyce, Russell
Submitted: 2016-06-22, last modified: 2016-07-26
The Australian Space Eye is a proposed astronomical telescope based on a 6U
CubeSat platform. The Space Eye will exploit the low level of systematic errors
achievable with a small space based telescope to enable high accuracy
measurements of the optical extragalactic background light and low surface
brightness emission around nearby galaxies. This project is also a demonstrator
for several technologies with general applicability to astronomical
observations from nanosatellites. Space Eye is based around a 90 mm aperture
clear aperture all refractive telescope for broadband wide field imaging in the
i and z bands.
[3]
oai:arXiv.org:1108.5304 [pdf] - 1083655
Solar magnetism eXplorer (SolmeX)
Peter, H.;
Abbo, L.;
Andretta, V.;
Auchere, F.;
Bemporad, A.;
Berrilli, F.;
Bommier, V.;
Braukhane, A.;
Casini, R.;
Curdt, W.;
Davila, J.;
Dittus, H.;
Fineschi, S.;
Fludra, A.;
Gandorfer, A.;
Griffin, D.;
Inhester, B.;
Lagg, A.;
Degl'Innocenti, E. Landi;
Maiwald, V.;
Sainz, R. Manso;
Pillet, V. Martinez;
Matthews, S.;
Moses, D.;
Parenti, S.;
Pietarila, A.;
Quantius, D.;
Raouafi, N. -E.;
Raymond, J.;
Rochus, P.;
Romberg, O.;
Schlotterer, M.;
Schuehle, U.;
Solanki, S.;
Spadaro, D.;
Teriaca, L.;
Tomczyk, S.;
Bueno, J. Trujillo;
Vial, J. -C.
Submitted: 2011-08-26
The magnetic field plays a pivotal role in many fields of Astrophysics. This
is especially true for the physics of the solar atmosphere. Measuring the
magnetic field in the upper solar atmosphere is crucial to understand the
nature of the underlying physical processes that drive the violent dynamics of
the solar corona -- that can also affect life on Earth.
SolmeX, a fully equipped solar space observatory for remote-sensing
observations, will provide the first comprehensive measurements of the strength
and direction of the magnetic field in the upper solar atmosphere. The mission
consists of two spacecraft, one carrying the instruments, and another one in
formation flight at a distance of about 200m carrying the occulter to provide
an artificial total solar eclipse. This will ensure high-quality coronagraphic
observations above the solar limb.
Solmex integrates two spectro-polarimetric coronagraphs for off-limb
observations, one in the EUV and one in the IR, and three instruments for
observations on the disk. The latter comprises one imaging polarimeter in the
EUV for coronal studies, a spectro-polarimeter in the EUV to investigate the
low corona, and an imaging spectro-polarimeter in the UV for chromospheric
studies.
SOHO and other existing missions have investigated the emission of the upper
atmosphere in detail (not considering polarization), and as this will be the
case also for missions planned for the near future. Therefore it is timely that
SolmeX provides the final piece of the observational quest by measuring the
magnetic field in the upper atmosphere through polarimetric observations.
[4]
oai:arXiv.org:1005.5073 [pdf] - 1032794
In-flight calibration of the Herschel-SPIRE instrument
Swinyard, B. M.;
Ade, P.;
Baluteau, J-P.;
Aussel, H.;
Barlow, M. J.;
Bendo, G. J.;
Benielli, D.;
Bock, J.;
Brisbin, D.;
Conley, A.;
Conversi, L.;
Dowell, A.;
Dowell, D.;
Ferlet, M.;
Fulton, T.;
Glenn, J.;
Glauser, A.;
Griffin, D.;
Griffin, M.;
Guest, S.;
Imhof, P.;
Isaak, K.;
Jones, S.;
King, K.;
Leeks, S.;
Levenson, L.;
Lim, T. L.;
Lu, N.;
Makiwa, G.;
Naylor, D.;
Nguyen, H.;
Oliver, S.;
Panuzzo, P.;
Papageorgiou, A.;
Pearson, C.;
Pohlen, M.;
Polehampton, E.;
Pouliquen, D.;
Rigopoulou, D.;
Ronayette, S.;
Roussel, H.;
Rykala, A.;
Savini, G.;
Schulz, B.;
Schwartz, A.;
Shupe, D.;
Sibthorpe, B.;
Sidher, S.;
Smith, A. J.;
Spencer, L.;
Trichas, M.;
Triou, H.;
Valtchanov, I.;
Wesson, R.;
Woodcraft, A.;
Xu, C. K.;
Zemcov, M.;
Zhang, L.
Submitted: 2010-05-27
SPIRE, the Spectral and Photometric Imaging Receiver, is the Herschel Space
Observatory's submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 {\mu}m, and an imaging Fourier
transform spectrometer (FTS) covering 194-671 {\mu}m (447-1550 GHz). In this
paper we describe the initial approach taken to the absolute calibration of the
SPIRE instrument using a combination of the emission from the Herschel
telescope itself and the modelled continuum emission from solar system objects
and other astronomical targets. We present the photometric, spectroscopic and
spatial accuracy that is obtainable in data processed through the "standard"
pipelines. The overall photometric accuracy at this stage of the mission is
estimated as 15% for the photometer and between 15 and 50% for the
spectrometer. However, there remain issues with the photometric accuracy of the
spectra of low flux sources in the longest wavelength part of the SPIRE
spectrometer band. The spectrometer wavelength accuracy is determined to be
better than 1/10th of the line FWHM. The astrometric accuracy in SPIRE maps is
found to be 2 arcsec when the latest calibration data are used. The photometric
calibration of the SPIRE instrument is currently determined by a combination of
uncertainties in the model spectra of the astronomical standards and the data
processing methods employed for map and spectrum calibration. Improvements in
processing techniques and a better understanding of the instrument performance
will lead to the final calibration accuracy of SPIRE being determined only by
uncertainties in the models of astronomical standards.
[5]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.
[6]
oai:arXiv.org:astro-ph/0511561 [pdf] - 1233660
Ionisation state, excited populations and emission of impurities in
dynamic finite density plasmas. I: The generalised collisional-radiative
model for light elements
Submitted: 2005-11-18
The paper presents an integrated view of the population structure and its
role in establishing the ionisation state of light elements in dynamic, finite
density, laboratory and astrophysical plasmas. There are four main issues, the
generalised collisional-radiative picture for metastables in dynamic plasmas
with Maxwellian free electrons and its particularising to light elements, the
methods of bundling and projection for manipulating the population equations,
the systematic production/use of state selective fundamental collision data in
the metastable resolved picture to all levels for collisonal-radiative
modelling and the delivery of appropriate derived coefficients for experiment
analysis. The ions of carbon, oxygen and neon are used in illustration. The
practical implementation of the methods described here is part of the ADAS
Project.