sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Gregorio, R. R. Marcelo

Normalized to: Gregorio, R.

2 article(s) in total. 6 co-authors, from 1 to 2 common article(s). Median position in authors list is 3,5.

[1]  oai:arXiv.org:1909.13881  [pdf] - 1972740
Demonstration of ThGEM-Multiwire Hybrid Charge Readout for Directional Dark Matter Searches
Comments: 17 pages, 18 figures
Submitted: 2019-09-30, last modified: 2019-10-02
Sensitivities of current directional dark matter search detectors using gas time projection chambers are now constrained by target mass. A ton-scale gas TPC detector will require large charge readout areas. We present a first demonstration of a novel ThGEM-Multiwire hybrid charge readout technology which combines the robust nature and high gas gain of Thick Gaseous Electron Multipliers with lower capacitive noise of a one-plane multiwire charge readout in SF$_6$ target gas. Measurements performed with this hybrid detector show an ion drift velocity of $139~\pm~12~\text{ms}^{-1}$ in a reduced drift field $\text{E/N}$ of $93~\text{Td}~(10^{-17}~\text{V cm}^{2})$ at a gas gain of $2470\pm160$ in 20 Torr of pure SF$_\text{6}$ target gas.
[2]  oai:arXiv.org:1707.07772  [pdf] - 1586332
Demonstration of radon removal from SF$_6$ using molecular sieves
Comments: 12 pages, 10 figures
Submitted: 2017-07-24, last modified: 2017-10-04
The gas SF$_6$ has become of interest as a negative ion drift gas for use in directional dark matter searches. However, as for other targets in such searches, it is important that radon contamination can be removed as this provides a source of unwanted background events. In this work we demonstrate for the first time filtration of radon from SF$_6$ gas by using a molecular sieve. Four types of sieves from Sigma-Aldrich were investigated, namely 3{\AA}, 4{\AA}, 5{\AA} and 13X. A manufactured radon source was used for the tests. This was attached to a closed loop system in which gas was flowed through the filters and a specially adapted Durridge RAD7 radon detector. In these measurements, it was found that only the 5{\AA} type was able to significantly reduce the radon concentration without absorbing the SF$_6$ gas. The sieve was able to reduce the initial radon concentration of 3875 $\pm$ 13 Bqm$^{-3}$ in SF$_6$ gas by 87% when cooled with dry ice. The ability of the cooled 5{\AA} molecular sieve filter to significantly reduce radon concentration from SF$_6$ provides a promising foundation for the construction of a radon filtration setup for future ultra-sensitive SF$_6$ gas rare-event physics experiments.