Normalized to: Grauf, B.
[1]
oai:arXiv.org:1903.11061 [pdf] - 1857241
The Polarimetric and Helioseismic Imager on Solar Orbiter
Solanki, S. K.;
Iniesta, J. C. del Toro;
Woch, J.;
Gandorfer, A.;
Hirzberger, J.;
Alvarez-Herrero, A.;
Appourchaux, T.;
Pillet, V. Martínez;
Pérez-Grande, I.;
Kilders, E. Sanchis;
Schmidt, W.;
Cama, J. M. Gómez;
Michalik, H.;
Deutsch, W.;
Fernandez-Rico, G.;
Grauf, B.;
Gizon, L.;
Heerlein, K.;
Kolleck, M.;
Lagg, A.;
Meller, R.;
Müller, R.;
Schühle, U.;
Staub, J.;
Albert, K.;
Copano, M. Alvarez;
Beckmann, U.;
Bischoff, J.;
Busse, D.;
Enge, R.;
Frahm, S.;
Germerott, D.;
Guerrero, L.;
Löptien, B.;
Meierdierks, T.;
Oberdorfer, D.;
Papagiannaki, I.;
Ramanath, S.;
Schou, J.;
Werner, S.;
Yang, D.;
Zerr, A.;
Bergmann, M.;
Bochmann, J.;
Heinrichs, J.;
Meyer, S.;
Monecke, M.;
Müller, M. -F.;
Sperling, M.;
a, D. Álvarez Garcí;
Aparicio, B.;
Jiménez, M. Balaguer;
Rubio, L. R. Bellot;
Carracosa, J. P. Cobos;
Girela, F.;
Expósito, D. Hernández;
Herranz, M.;
Labrousse, P.;
Jiménez, A. López;
Suárez, D. Orozco;
Ramos, J. L.;
Barandiarán, J.;
Bastide, L.;
Campuzano, C.;
Cebollero, M.;
Dávila, B.;
Fernández-Medina, A.;
Parejo, P. García;
Garranzo-García, D.;
Laguna, H.;
Martín, J. A.;
Navarro, R.;
Peral, A. Núñez;
Royo, M.;
Sánchez, A.;
Silva-López, M.;
Vera, I.;
Villanueva, J.;
Fourmond, J. -J.;
de Galarreta, C. Ruiz;
Bouzit, M.;
Hervier, V.;
Clec'h, J. C. Le;
Szwec, N.;
Chaigneau, M.;
Buttice, V.;
Dominguez-Tagle, C.;
Philippon, A.;
Boumier, P.;
Cocguen, R. Le;
Baranjuk, G.;
Bell, A.;
Berkefeld, Th.;
Baumgartner, J.;
Heidecke, F.;
Maue, T.;
Nakai, E.;
Scheiffelen, T.;
Sigwarth, M.;
Soltau, D.;
Volkmer, R.;
Rodríguez, J. Blanco;
Domingo, V.;
Sabater, A. Ferreres;
Blesa, J. L. Gasent;
Martínez, P. Rodríguez;
Caudel, D. Osorno;
Bosch, J.;
Casas, A.;
Carmona, M.;
Herms, A.;
Roma, D.;
Alonso, G.;
omez-Sanjuan, A. G\';
Piqueras, J.;
Torralbo, I.;
Fiethe, B.;
Guan, Y.;
Lange, T.;
Michel, H.;
Bonet, J. A.;
Fahmy, S.;
Müller, D.;
Zouganelis, I.
Submitted: 2019-03-26
This paper describes the Polarimetric and Helioseismic Imager on the Solar
Orbiter mission (SO/PHI), the first magnetograph and helioseismology instrument
to observe the Sun from outside the Sun-Earth line. It is the key instrument
meant to address the top-level science question: How does the solar dynamo work
and drive connections between the Sun and the heliosphere? SO/PHI will also
play an important role in answering the other top-level science questions of
Solar Orbiter, as well as hosting the potential of a rich return in further
science.
SO/PHI measures the Zeeman effect and the Doppler shift in the FeI 617.3nm
spectral line. To this end, the instrument carries out narrow-band imaging
spectro-polarimetry using a tunable LiNbO_3 Fabry-Perot etalon, while the
polarisation modulation is done with liquid crystal variable retarders (LCVRs).
The line and the nearby continuum are sampled at six wavelength points and the
data are recorded by a 2kx2k CMOS detector. To save valuable telemetry, the raw
data are reduced on board, including being inverted under the assumption of a
Milne-Eddington atmosphere, although simpler reduction methods are also
available on board. SO/PHI is composed of two telescopes; one, the Full Disc
Telescope (FDT), covers the full solar disc at all phases of the orbit, while
the other, the High Resolution Telescope (HRT), can resolve structures as small
as 200km on the Sun at closest perihelion. The high heat load generated through
proximity to the Sun is greatly reduced by the multilayer-coated entrance
windows to the two telescopes that allow less than 4% of the total sunlight to
enter the instrument, most of it in a narrow wavelength band around the chosen
spectral line.
[2]
oai:arXiv.org:1701.01555 [pdf] - 1557821
The second flight of the SUNRISE balloon-borne solar observatory:
overview of instrument updates, the flight, the data and first results
Solanki, S. K.;
Riethmüller, T. L.;
Barthol, P.;
Danilovic, S.;
Deutsch, W.;
Doerr, H. P.;
Feller, A.;
Gandorfer, A.;
Germerott, D.;
Gizon, L.;
Grauf, B.;
Heerlein, K.;
Hirzberger, J.;
Kolleck, M.;
Lagg, A.;
Meller, R.;
Tomasch, G.;
van Noort, M.;
Rodríguez, J. Blanco;
Blesa, J. L. Gasent;
Jiménez, M. Balaguer;
Iniesta, J. C. Del Toro;
Jiménez, A. C. López;
Suárez, D. Orozco;
Berkefeld, T.;
Halbgewachs, C.;
Schmidt, W.;
Álvarez-Herrero, A.;
Sabau-Graziati, L.;
Grande, I. Pérez;
Pillet, V. Martínez;
Card, G.;
Centeno, R.;
Knölker, M.;
Lecinski, A.
Submitted: 2017-01-06
The SUNRISE balloon-borne solar observatory, consisting of a 1~m aperture
telescope that provided a stabilized image to a UV filter imager and an imaging
vector polarimeter, carried out its second science flight in June 2013. It
provided observations of parts of active regions at high spatial resolution,
including the first high-resolution images in the Mg~{\sc ii}~k line. The
obtained data are of very high quality, with the best UV images reaching the
diffraction limit of the telescope at 3000~\AA\ after Multi-Frame Blind
Deconvolution reconstruction accounting for phase-diversity information. Here a
brief update is given of the instruments and the data reduction techniques,
which includes an inversion of the polarimetric data. Mainly those aspects that
evolved compared with the first flight are described. A tabular overview of the
observations is given. In addition, an example time series of a part of the
emerging active region NOAA AR~11768 observed relatively close to disk centre
is described and discussed in some detail. The observations cover the pores in
the trailing polarity of the active region, as well as the polarity inversion
line where flux emergence was ongoing and a small flare-like brightening
occurred in the course of the time series. The pores are found to contain
magnetic field strengths ranging up to 2500~G and, while large pores are
clearly darker and cooler than the quiet Sun in all layers of the photosphere,
the temperature and brightness of small pores approach or even exceed those of
the quiet Sun in the upper photosphere.
[3]
oai:arXiv.org:1009.3196 [pdf] - 1040623
The Wave-Front Correction System for the Sunrise Balloon-Borne Solar
Observatory
Berkefeld, T.;
Schmidt, W.;
Soltau, D.;
Bell, A.;
Doerr, H. P.;
Feger, B.;
Friedlein, R.;
Gerber, K.;
Heidecke, F.;
Kentischer, T.;
Lühe, O. v. d.;
Sigwarth, M.;
Wälde, E.;
Barthol, P.;
Deutsch, W.;
Gandorfer, A.;
Germerott, D.;
Grauf, B.;
Meller, R.;
Alvarez-Herrero, A.;
Knölker, M.;
Pillet, V. Martinez;
Solanki, S. K.;
Title, A. M.
Submitted: 2010-09-16
This paper describes the wave-front correction system developed for the
Sunrise balloon telescope, and provides information about its in-flight
performance. For the correction of low-order aberrations, a Correlating
Wave-Front Sensor (CWS) was used. It consisted of a six-element Shack-Hartmann
wave-front sensor (WFS), a fast tip-tilt mirror for the compensation of image
motion, and an active telescope secondary mirror for focus correction. The CWS
delivered a stabilized image with a precision of 0.04 arcsec (rms), whenever
the coarse pointing was better than 90 arcsec peak-to-peak. The automatic focus
adjustment maintained a focus stability of 0.01 waves in the focal plane of the
CWS. During the 5.5 day flight, good image quality and stability was achieved
during 33 hours, containing 45 sequences that lasted between 10 and 45 minutes.
[4]
oai:arXiv.org:1009.2689 [pdf] - 1034954
The Sunrise Mission
Barthol, Peter;
Gandorfer, Achim;
Solanki, Sami K.;
Schüssler, Manfred;
Chares, Bernd;
Curdt, Werner;
Deutsch, Werner;
Feller, Alex;
Germerott, Dietmar;
Grauf, Bianca;
Heerlein, Klaus;
Hirzberger, Johann;
Kolleck, Martin;
Meller, Reinhard;
Müller, Reinhard;
Riethmüller, Tino L.;
Tomasch, Georg;
Knölker, Michael;
Lites, Bruce W.;
Card, Greg;
Elmore, David;
Fox, Jack;
Lecinski, Alice;
Nelson, Peter;
Summers, Richard;
Watt, Andrew;
Pillet, Valentin Martínez;
Bonet, Jose Antonio;
Schmidt, Wolfgang;
Berkefeld, Thomas;
Title, Alan M.;
Domingo, Vicente;
Blesa, Jose Luis Gasent;
Iniesta, Jose Carlos del Toro;
Jiménez, Antonio López;
Álvarez-Herrero, Alberto;
Sabau-Graziati, Lola;
Widani, Christoph;
Haberler, Peter;
Härtel, Klaus;
Kampf, Dirk;
Levin, Thorsten;
Grande, Isabel Pérez;
Sanz-Andrés, Angel;
Schmidt, Elke
Submitted: 2010-09-14
The first science flight of the balloon-borne \Sunrise telescope took place
in June 2009 from ESRANGE (near Kiruna/Sweden) to Somerset Island in northern
Canada. We describe the scientific aims and mission concept of the project and
give an overview and a description of the various hardware components: the 1-m
main telescope with its postfocus science instruments (the UV filter imager
SuFI and the imaging vector magnetograph IMaX) and support instruments (image
stabilizing and light distribution system ISLiD and correlating wavefront
sensor CWS), the optomechanical support structure and the instrument mounting
concept, the gondola structure and the power, pointing, and telemetry systems,
and the general electronics architecture. We also explain the optimization of
the structural and thermal design of the complete payload. The preparations for
the science flight are described, including AIV and ground calibration of the
instruments. The course of events during the science flight is outlined, up to
the recovery activities. Finally, the in-flight performance of the
instrumentation is briefly summarized.
[5]
oai:arXiv.org:1009.1037 [pdf] - 1034726
The Filter Imager SuFI and the Image Stabilization and Light
Distribution System ISLiD of the Sunrise Balloon-Borne Observatory:
Instrument Description
Gandorfer, A.;
Grauf, B.;
Barthol, P.;
Riethmueller, T. L.;
Solanki, S. K.;
Chares, B.;
Deutsch, W.;
Ebert, S.;
Feller, A.;
Germerott, D.;
Heerlein, K.;
Heinrichs, J.;
Hirche, D.;
Hirzberger, J.;
Kolleck, M.;
Meller, R.;
Mueller, R.;
Schaefer, R.;
Tomasch, G.;
Knoelker, M.;
Pillet, V. Martinez;
Bonet, J. A.;
Schmidt, W.;
Berkefeld, T.;
Feger, B.;
Heidecke, F.;
Soltau, D.;
Tischenberg, A.;
Fischer, A.;
Title, A.;
Anwand, H.;
Schmidt, E.
Submitted: 2010-09-06
We describe the design of the Sunrise Filter Imager (SuFI) and the Image
Stabilization and Light Distribution (ISLiD) unit onboard the Sunrise balloon
borne solar observatory. This contribution provides the necessary information
which is relevant to understand the instruments working principles, the
relevant technical data, and the necessary information about calibration issues
directly related to the science data.
[6]
oai:arXiv.org:1009.1095 [pdf] - 1034734
The Imaging Magnetograph eXperiment (IMaX) for the Sunrise balloon-borne
solar observatory
Pillet, V. Martinez;
Iniesta, J. C. del Toro;
Alvarez-Herrero, A.;
Domingo, V.;
Bonet, J. A.;
Fernandez, L. Gonzalez;
Jimenez, A. Lopez;
Pastor, C.;
Blesa, J. L. Gasent;
Mellado, P.;
Piqueras, J.;
Aparicio, B.;
Balaguer, M.;
Ballesteros, E.;
Belenguer, T.;
Rubio, L. R. Bellot;
Berkefeld, T.;
Collados, M.;
Deutsch, W.;
Feller, A.;
Girela, F.;
Grauf, B.;
Heredero, R. L.;
Herranz, M.;
Jeronimo, J. M.;
Laguna, H.;
Meller, R.;
Menendez, M.;
Morales, R.;
Suarez, D. Orozco;
Ramos, G.;
Reina, M.;
Ramos, J. L.;
Rodriguez, P.;
Sanchez, A.;
Uribe-Patarroyo, N.;
Barthol, P.;
Gandorfer, A.;
Knoelker, M.;
Schmidt, W.;
Solanki, S. K.;
Dominguez, S. Vargas
Submitted: 2010-09-06
The Imaging Magnetograph eXperiment (IMaX) is a spectropolarimeter built by
four institutions in Spain that flew on board the Sunrise balloon-borne
telesocope in June 2009 for almost six days over the Arctic Circle. As a
polarimeter IMaX uses fast polarization modulation (based on the use of two
liquid crystal retarders), real-time image accumulation, and dual beam
polarimetry to reach polarization sensitivities of 0.1%. As a spectrograph, the
instrument uses a LiNbO3 etalon in double pass and a narrow band pre-filter to
achieve a spectral resolution of 85 mAA. IMaX uses the high Zeeman sensitive
line of Fe I at 5250.2 AA and observes all four Stokes parameters at various
points inside the spectral line. This allows vector magnetograms, Dopplergrams,
and intensity frames to be produced that, after reconstruction, reach spatial
resolutions in the 0.15-0.18 arcsec range over a 50x50 arcsec FOV. Time
cadences vary between ten and 33 seconds, although the shortest one only
includes longitudinal polarimetry. The spectral line is sampled in various ways
depending on the applied observing mode, from just two points inside the line
to 11 of them. All observing modes include one extra wavelength point in the
nearby continuum. Gauss equivalent sensitivities are four Gauss for
longitudinal fields and 80 Gauss for transverse fields per wavelength sample.
The LOS velocities are estimated with statistical errors of the order of 5-40
m/s. The design, calibration and integration phases of the instrument, together
with the implemented data reduction scheme are described in some detail.