Normalized to: Grandi, L.
[1]
oai:arXiv.org:2006.09721 [pdf] - 2124928
Observation of Excess Electronic Recoil Events in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Angevaare, J. R.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Cimmino, B.;
Clark, M.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Di Stefano, R.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Ferella, A. D.;
Fulgione, W.;
Gaemers, P.;
Gaior, R.;
Galloway, M.;
Gao, F.;
Grandi, L.;
Hasterok, C.;
Hils, C.;
Hiraide, K.;
Hoetzsch, L.;
Howlett, J.;
Iacovacci, M.;
Itow, Y.;
Joerg, F.;
Kato, N.;
Kazama, S.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Long, J.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Mancuso, A.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Martens, K.;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Miuchi, K.;
Mizukoshi, K.;
Molinario, A.;
Morå, K.;
Moriyama, S.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Semeria, F.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Takeda, A.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Volta, G.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Weiss, M.;
Wenz, D.;
Wittweg, C.;
Xu, Z.;
Yamashita, M.;
Ye, J.;
Zavattini, G.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.;
Mougeot, X.
Submitted: 2020-06-17, last modified: 2020-06-30
We report results from searches for new physics with low-energy electronic
recoil data recorded with the XENON1T detector, with an exposure of 0.65 t-y
and an unprecedentedly low background rate of $76 \pm 2_{stat}$ events/(t y
keV) between 1-30 keV. An excess over known backgrounds is observed below 7
keV, rising towards lower energies and prominent between 2-3 keV. The solar
axion model has a 3.5$\sigma$ significance, and a three-dimensional 90%
confidence surface is reported for axion couplings to electrons, photons, and
nucleons. This surface is inscribed in the cuboid defined by $g_{ae} < 3.7
\times 10^{-12}$, $g_{ae}g_{an}^{eff} < 4.6 \times 10^{-18}$, and
$g_{ae}g_{a\gamma} < 7.6\times10^{-22}~{GeV}^{-1}$, and excludes either
$g_{ae}=0$ or $g_{ae}g_{a\gamma}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic
moment signal is similarly favored over background at 3.2$\sigma$ and a
confidence interval of $\mu_{\nu} \in (1.4,~2.9)\times10^{-11}\mu_B$ (90% C.L.)
is reported. Both results are in strong tension with stellar constraints. The
excess can also be explained by $\beta$ decays of tritium at 3.2$\sigma$
significance with a corresponding tritium concentration in xenon of $(6.2 \pm
2.0) \times 10^{-25}$ mol/mol. Such a trace amount can be neither confirmed nor
excluded with current knowledge of production and reduction mechanisms. The
significances of the solar axion and neutrino magnetic moment hypotheses are
decreased to 2.1$\sigma$ and 0.9$\sigma$, respectively, if an unconstrained
tritium component is included in the fitting. With respect to bosonic dark
matter, the excess favors a monoenergetic peak at ($2.3 \pm 0.2$) keV (68%
C.L.) with a 3.0$\sigma$ global (4.0$\sigma$ local) significance over
background. This analysis sets the most restrictive direct constraints to date
on pseudoscalar and vector bosonic dark matter for most masses between 1 and
210 keV/c$^2$.
[2]
oai:arXiv.org:2006.03114 [pdf] - 2109247
Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
Aalbers, J.;
Agostini, F.;
Maouloud, S. E. M. Ahmed;
Alfonsi, M.;
Althueser, L.;
Amaro, F.;
Angevaare, J.;
Antochi, V. C.;
Antunovic, B.;
Aprile, E.;
Arazi, L.;
Arneodo, F.;
Balzer, M.;
Baudis, L.;
Baur, D.;
Benabderrahmane, M. L.;
Biondi, Y.;
Bismark, A.;
Bourgeois, C.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruno, G.;
Brünner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J.;
Cichon, D.;
Clark, M.;
Colijn, A. P.;
Conrad, J.;
Cuenca-García, J. J.;
Cussonneau, J. P.;
Decowski, M. P.;
Depoian, A.;
Dierle, J.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Douillet, D.;
Drexlin, G.;
Eitel, K.;
Engel, R.;
Erdal, E.;
Ferella, A. D.;
Fischer, H.;
Fischer, P.;
Fulgione, W.;
Gaemers, P.;
Galloway, M.;
Gao, F.;
Giovagnoli, D.;
Girard, F.;
Glade-Beucke, R.;
Glück, F.;
Grandi, L.;
Grohmann, S.;
Größle, R.;
Gumbsheimer, R.;
Hannen, V.;
Hansmann-Menzemer, S.;
Hils, C.;
Holzapfel, B.;
Howlett, J.;
Iaquaniello, G.;
Jörg, F.;
Keller, M.;
Kellerer, J.;
Khundzakishvili, G.;
Kilminster, B.;
Kleifges, M.;
Kleiner, T. K.;
Koltmann, G.;
Kopec, A.;
Kopmann, A.;
Krauss, L. M.;
Kuger, F.;
LaCascio, L.;
Landsman, H.;
Lang, R. F.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Villalpando, A. Loya;
Ma, Y.;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Masson, E.;
McFadden, N.;
Meinhardt, P.;
Meyer, R.;
Milosevic, B.;
Milutinovic, S.;
Molinario, A.;
Monteiro, C. M. B.;
Morå, K.;
Morteau, E.;
Mosbacher, Y.;
Murra, M.;
Newstead, J. L.;
Ni, K.;
Oberlack, U. G.;
Obradovic, M.;
Odgers, K.;
Ostrovskiy, I.;
Palacio, J.;
Pandurovic, M.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pierre, M.;
Pizzella, V.;
Plante, G.;
Qi, J.;
Qin, J.;
García, D. Ramírez;
Reichard, S. E.;
Rupp, N.;
Sanchez-Lucas, P.;
Santos, J.;
Sartorelli, G.;
Schulte, D.;
Schultz-Coulon, H. -C.;
Eißing, H. Schulze;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Sharma, S.;
Shen, W.;
Silva, M.;
Simgen, H.;
Steidl, M.;
Stern, S.;
Subotic, D.;
Szabo, P.;
Terliuk, A.;
Therreau, C.;
Thers, D.;
Thieme, K.;
Toennies, F.;
Trotta, R.;
Tunnell, C. D.;
Valerius, K.;
Volta, G.;
Vorkapic, D.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Weiss, M.;
Wenz, D.;
Wittweg, C.;
Wolf, J.;
Wuestling, S.;
Wurm, M.;
Xing, Y.;
Zhu, T.;
Zhu, Y.;
Zopounidis, J. P.;
Zuber, K.
Submitted: 2020-06-04
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to
solar neutrinos via elastic electron scattering. We find that DARWIN will have
the potential to measure the fluxes of five solar neutrino components: $pp$,
$^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O
and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and,
thus, would benefit from a depleted target. A high-statistics observation of
$pp$ neutrinos would allow us to infer the values of the weak mixing angle,
$\sin^2\theta_w$, and the electron-type neutrino survival probability, $P_e$,
in the electron recoil energy region from a few keV up to 200 keV for the first
time, with relative precision of 5% and 4%, respectively, at an exposure of 300
ty. An observation of $pp$ and $^7$Be neutrinos would constrain the
neutrino-inferred solar luminosity down to 0.2%. A combination of all flux
measurements would distinguish between the high (GS98) and low metallicity
(AGS09) solar models with 2.1-2.5$\sigma$ significance, independent of external
measurements from other experiments or a measurement of $^8$B neutrinos through
coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate
that with a depleted target DARWIN may be sensitive to the neutrino capture
process of $^{131}$Xe.
[3]
oai:arXiv.org:2003.03825 [pdf] - 2060953
Energy resolution and linearity in the keV to MeV range measured in
XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Angevaare, J.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Cimmino, B.;
Clark, M.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Di Stefano, A. Depoian P. Di Gangi A. Di Giovanni R.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Ferella, A. D.;
Fulgione, W.;
Gaemers, P.;
Gaior, R.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Hasterok, C.;
Hils, C.;
Hiraide, K.;
Hoetzsch, L.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itow, Y.;
Joerg, F.;
Kato, N.;
Kazama, S.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Martens, K.;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Miuchi, K.;
Molinario, A.;
Morå, K.;
Moriyama, S.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Qin, G. Plante J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Semeria, F.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Takeda, A.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Xu, M. Weiss;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Xu, Z.;
Yamashita, M.;
Ye, J.;
Zavattini, G.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2020-03-08
Xenon dual-phase time projection chambers designed to search for Weakly
Interacting Massive Particles have so far shown a relative energy resolution
which degrades with energy above $\sim$200 keV. This has limited their
sensitivity in the search for rare events like the neutrinoless double-beta
decay of $^{136}$Xe at its $Q$-value, $Q_{\beta\beta}\simeq$ 2.46 MeV. For the
XENON1T dual-phase time projection chamber, we demonstrate that the relative
energy resolution at 1 $\sigma/\mu$ is as low as (0.79$\pm$0.02) % in its
one-ton fiducial mass, and for single-site interactions at $Q_{\beta\beta}$. We
achieve this by using a signal correction method to rectify the saturation
effects of the signal readout system. The very good energy resolution from keV
to MeV energies demonstrated in XENON1T opens up new windows for the xenon
dual-phase dark matter detectors to simultaneously search for other rare
events.
[4]
oai:arXiv.org:1907.12771 [pdf] - 2021183
Search for Light Dark Matter Interactions Enhanced by the Migdal effect
or Bremsstrahlung in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gaemers, P.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hils, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kazama, S.;
Kish, A.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2019-07-30, last modified: 2019-12-24
Direct dark matter detection experiments based on a liquid xenon target are
leading the search for dark matter particles with masses above $\sim$ 5
GeV/c$^2$, but have limited sensitivity to lighter masses because of the small
momentum transfer in dark matter-nucleus elastic scattering. However, there is
an irreducible contribution from inelastic processes accompanying the elastic
scattering, which leads to the excitation and ionization of the recoiling atom
(the Migdal effect) or the emission of a Bremsstrahlung photon. In this letter,
we report on a probe of low-mass dark matter with masses down to about 85
MeV/c$^2$ by looking for electronic recoils induced by the Migdal effect and
Bremsstrahlung, using data from the XENON1T experiment. Besides the approach of
detecting both scintillation and ionization signals, we exploit an approach
that uses ionization signals only, which allows for a lower detection
threshold. This analysis significantly enhances the sensitivity of XENON1T to
light dark matter previously beyond its reach.
[5]
oai:arXiv.org:1907.11485 [pdf] - 2015750
Light Dark Matter Search with Ionization Signals in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gaemers, P.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hils, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kazama, S.;
Kish, A.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2019-07-26, last modified: 2019-12-17
We report constraints on light dark matter (DM) models using ionization
signals in the XENON1T experiment. We mitigate backgrounds with strong event
selections, rather than requiring a scintillation signal, leaving an effective
exposure of $(22 \pm 3)$ tonne-days. Above
$\sim\!0.4\,\mathrm{keV}_\mathrm{ee}$, we observe $<1 \,
\text{event}/(\text{tonne} \times \text{day} \times \text{keV}_\text{ee})$,
which is more than one thousand times lower than in similar searches with other
detectors. Despite observing a higher rate at lower energies, no DM or CEvNS
detection may be claimed because we cannot model all of our backgrounds. We
thus exclude new regions in the parameter spaces for DM-nucleus scattering for
DM masses $m_\chi$ within $3-6\,\mathrm{GeV}/\mathrm{c}^2$, DM-electron
scattering for $m_\chi > 30\,\mathrm{MeV}/\mathrm{c}^2$, and absorption of dark
photons and axion-like particles for $m_\chi$ within $0.186 - 1 \,
\mathrm{keV}/\mathrm{c}^2$.
[6]
oai:arXiv.org:1902.03234 [pdf] - 1875324
Constraining the Spin-Dependent WIMP-Nucleon Cross Sections with XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Antochi, V. C.;
Arneodo, F.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kazama, S.;
Kish, A.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Pelssers, B.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Priel, N.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rizzo, A.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Xu, Z.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2019-02-08, last modified: 2019-04-30
We report the first experimental results on spin-dependent elastic weakly
interacting massive particle (WIMP) nucleon scattering from the XENON1T dark
matter search experiment. The analysis uses the full ton year exposure of
XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No
significant signal excess is observed, and a profile likelihood ratio analysis
is used to set exclusion limits on the WIMP-nucleon interactions. This includes
the most stringent constraint to date on the WIMP-neutron cross section, with a
minimum of $6.3\times10^{-42}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence
level. The results are compared with those from collider searches and used to
exclude new parameter space in an isoscalar theory with an axial-vector
mediator.
[7]
oai:arXiv.org:1811.12482 [pdf] - 1836537
First results on the scalar WIMP-pion coupling, using the XENON1T
experiment
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Antochi, V. C.;
Arneodo, F.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kaminsky, B.;
Kazama, S.;
Kish, A.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Pelssers, B.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Priel, N.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rizzo, A.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.;
Hoferichter, M.;
Klos, P.;
Menéndez, J.;
Schwenk, A.
Submitted: 2018-11-29, last modified: 2019-02-22
We present first results on the scalar WIMP-pion coupling from 1 t$\times$yr
of exposure with the XENON1T experiment. This interaction is generated when the
WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In
contrast to most non-relativistic operators, these pion-exchange currents can
be coherently enhanced by the total number of nucleons, and therefore may
dominate in scenarios where spin-independent WIMP-nucleon interactions are
suppressed. Moreover, for natural values of the couplings, they dominate over
the spin-dependent channel due to their coherence in the nucleus. Using the
signal model of this new WIMP-pion channel, no significant excess is found,
leading to an upper limit cross section of $6.4\times10^{-46}$ cm$^2$ (90 %
confidence level) at 30 GeV/c$^2$ WIMP mass.
[8]
oai:arXiv.org:1805.12562 [pdf] - 1749718
Dark Matter Search Results from a One Tonne$\times$Year Exposure of
XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Grandi, L.;
Greene, Z.;
Qiu, H.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Itay, R.;
Joerg, F.;
Kaminsky, B.;
Kazama, S.;
Kish, A.;
Koltman, G.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Mahlstedt, J.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pelssers, B.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Riedel, B.;
Rizzo, A.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.
Submitted: 2018-05-31, last modified: 2018-09-13
We report on a search for Weakly Interacting Massive Particles (WIMPs) using
278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T
utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30
\pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of
interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$),
exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\
-3}\textrm{ (sys)}\pm3\textrm{ (stat)})$
events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant
excess over background is found and a profile likelihood analysis parameterized
in spatial and energy dimensions excludes new parameter space for the
WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses
above 6 GeV/c${}^2$, with a minimum of $4.1\times10^{-47}$ cm$^2$ at 30
GeV/c${}^2$ and 90% confidence level.
[9]
oai:arXiv.org:1710.00219 [pdf] - 1648640
Characterization of photomultiplier tubes with a realistic model through
GPU-boosted simulation
Submitted: 2017-09-30, last modified: 2018-02-25
The accurate characterization of a photomultiplier tube (PMT) is crucial in a
wide-variety of applications. However, current methods do not give fully
accurate representations of the response of a PMT, especially at very low light
levels. In this work, we present a new and more realistic model of the response
of a PMT, called the cascade model, and use it to characterize two different
PMTs at various voltages and light levels. The cascade model is shown to
outperform the more common Gaussian model in almost all circumstances and to
agree well with a newly introduced model independent approach. The technical
and computational challenges of this model are also presented along with the
employed solution of developing a robust GPU-based analysis framework for this
and other non-analytical models.
[10]
oai:arXiv.org:1709.10149 [pdf] - 1690301
Signal Yields of keV Electronic Recoils and Their Discrimination from
Nuclear Recoils in Liquid Xenon
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rupp, N.;
Saldanha, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.
Submitted: 2017-09-28, last modified: 2018-02-01
We report on the response of liquid xenon to low energy electronic recoils
below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm
and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method
based on Markov Chain Monte Carlo is used to extract the photon yields and
recombination fluctuations from the experimental data. The photon yields
measured at the two lower fields are in agreement with those from literature;
additional measurements at a higher field of 366 V/cm are presented. The
electronic and nuclear recoil discrimination as well as its dependence on the
drift field and photon detection efficiency are investigated at these low
energies. The results provide new measurements in the energy region of interest
for dark matter searches using liquid xenon.
[11]
oai:arXiv.org:1705.06655 [pdf] - 1583594
First Dark Matter Search Results from the XENON1T Experiment
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Gardner, R.;
Geis, C.;
Goetzke, L. W.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Itay, R.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Manfredini, A.;
Mariş, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Riedel, B.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Saldanha, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thapa, S.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Upole, N.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.
Submitted: 2017-05-18, last modified: 2017-11-23
We report the first dark matter search results from XENON1T, a
$\sim$2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber
in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first
ton-scale detector of this kind. The blinded search used 34.2 live days of data
acquired between November 2016 and January 2017. Inside the (1042$\pm$12) kg
fiducial mass and in the [5, 40] $\mathrm{keV}_{\mathrm{nr}}$ energy range of
interest for WIMP dark matter searches, the electronic recoil background was
$(1.93 \pm 0.25) \times 10^{-4}$ events/(kg $\times$ day $\times
\mathrm{keV}_{\mathrm{ee}}$), the lowest ever achieved in a dark matter
detector. A profile likelihood analysis shows that the data is consistent with
the background-only hypothesis. We derive the most stringent exclusion limits
on the spin-independent WIMP-nucleon interaction cross section for WIMP masses
above 10 GeV/c${}^2$, with a minimum of 7.7 $\times 10^{-47}$ cm${}^2$ for
35-GeV/c${}^2$ WIMPs at 90% confidence level.
[12]
oai:arXiv.org:1708.07051 [pdf] - 1697916
The XENON1T Dark Matter Experiment
XENON Collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Antunes, B.;
Arneodo, F.;
Balata, M.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Chiarini, A.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Corrieri, R.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Disdier, J. -M.;
Doets, M.;
Duchovni, E.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Florin, D.;
Front, D.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Huhmann, C.;
Itay, R.;
James, A.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Maier, R.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orlandi, D.;
Othegraven, R.;
Pakarha, P.;
Parlati, S.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Saldahna, R.;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stern, M.;
Stein, A.;
Tatananni, D.;
Tatananni, L.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Walet, R.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.
Submitted: 2017-08-23
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is
the first WIMP dark matter detector operating with a liquid xenon target mass
above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute
the active target of the dual-phase time projection chamber. The scintillation
and ionization signals from particle interactions are detected with
low-background photomultipliers. This article describes the XENON1T instrument
and its subsystems as well as strategies to achieve an unprecedented low
background level. First results on the detector response and the performance of
the subsystems are also presented.
[13]
oai:arXiv.org:1602.03150 [pdf] - 1579821
Model Independent Approach to the Single Photoelectron Calibration of
Photomultiplier Tubes
Submitted: 2016-02-09, last modified: 2017-06-18
The accurate calibration of photomultiplier tubes is critical in a wide
variety of applications for which it is necessary to know the absolute number
of detected photons or precisely determine the resolution of the signal.
Conventional calibration methods rely on fitting the photomultiplier response
to a low intensity light source with analytical approximations to the single
photoelectron distribution. We show that this approach often leads to biased
estimates due to an inability to model the full distribution accurately,
especially at low charge values. We present a simple statistical method to
extract the relevant single photoelectron calibration parameters (first two
central moments) without making any assumptions about the underlying single
photoelectron distribution. We illustrate the use of this method through the
calibration of a Hamamatsu R11410 photomultiplier tube and study the accuracy
and precision of the method using Monte Carlo simulations. The method is found
to have significantly reduced bias compared to conventional methods and works
under a wide range of light intensities, making it suitable for the
simultaneous calibration of large arrays of photomultiplier tubes where uniform
illumination may not be possible.
[14]
oai:arXiv.org:1606.07001 [pdf] - 1525702
DARWIN: towards the ultimate dark matter detector
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Amsler, C.;
Aprile, E.;
Arazi, L.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Benabderrahmane, M. L.;
Berger, T.;
Beskers, B.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Calven, J.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Diglio, S.;
Drexlin, G.;
Duchovni, E.;
Erdal, E.;
Eurin, G.;
Ferella, A.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Di Gangi, P.;
Di Giovanni, A.;
Galloway, M.;
Garbini, M.;
Geis, C.;
Glueck, F.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hannen, V.;
Hogenbirk, E.;
Howlett, J.;
Hilk, D.;
Hils, C.;
James, A.;
Kaminsky, B.;
Kazama, S.;
Kilminster, B.;
Kish, A.;
Krauss, L. M.;
Landsman, H.;
Lang, R. F.;
Lin, Q.;
Linde, F. L.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Mora, K. D.;
Morteau, E.;
Murra, M.;
Naganoma, J.;
Newstead, J. L.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
de Perio, P.;
Persiani, R.;
Piastra, F.;
Piro, M. C.;
Plante, G.;
Rauch, L.;
Reichard, S.;
Rizzo, A.;
Rupp, N.;
Santos, J. M. F. Dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schumann, M.;
Schreiner, J.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M. C.;
Simgen, H.;
Sissol, P.;
von Sivers, M.;
Thers, D.;
Thurn, J.;
Tiseni, A.;
Trotta, R.;
Tunnell, C. D.;
Valerius, K.;
Vargas, M. A.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wester, T.;
Wulf, J.;
Zhang, Y.;
Zhu, T.;
Zuber, K.
Submitted: 2016-06-22
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for
the direct detection of dark matter using a multi-ton liquid xenon time
projection chamber at its core. Its primary goal will be to explore the
experimentally accessible parameter space for Weakly Interacting Massive
Particles (WIMPs) in a wide mass-range, until neutrino interactions with the
target become an irreducible background. The prompt scintillation light and the
charge signals induced by particle interactions in the xenon will be observed
by VUV sensitive, ultra-low background photosensors. Besides its excellent
sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large
mass, low-energy threshold and ultra-low background level will also be
sensitive to other rare interactions. It will search for solar axions, galactic
axion-like particles and the neutrinoless double-beta decay of 136-Xe, as well
as measure the low-energy solar neutrino flux with <1% precision, observe
coherent neutrino-nucleus interactions, and detect galactic supernovae. We
present the concept of the DARWIN detector and discuss its physics reach, the
main sources of backgrounds and the ongoing detector design and R&D efforts.
[15]
oai:arXiv.org:1510.00702 [pdf] - 1390602
Results from the first use of low radioactivity argon in a dark matter
search
The DarkSide Collaboration;
Agnes, P.;
Agostino, L.;
Albuquerque, I. F. M.;
Alexander, T.;
Alton, A. K.;
Arisaka, K.;
Back, H. O.;
Baldin, B.;
Biery, K.;
Bonfini, G.;
Bossa, M.;
Bottino, B.;
Brigatti, A.;
Brodsky, J.;
Budano, F.;
Bussino, S.;
Cadeddu, M.;
Cadonati, L.;
Cadoni, M.;
Calaprice, F.;
Canci, N.;
Candela, A.;
Cao, H.;
Cariello, M.;
Carlini, M.;
Catalanotti, S.;
Cavalcante, P.;
Chepurnov, A.;
Cocco, A. G.;
Covone, G.;
Crippa, L.;
D'Angelo, D.;
D'Incecco, M.;
Davini, S.;
De Cecco, S.;
De Deo, M.;
De Vincenzi, M.;
Derbin, A.;
Devoto, A.;
Di Eusanio, F.;
Di Pietro, G.;
Edkins, E.;
Empl, A.;
Fan, A.;
Fiorillo, G.;
Fomenko, K.;
Forster, G.;
Franco, D.;
Gabriele, F.;
Galbiati, C.;
Giganti, C.;
Goretti, A. M.;
Granato, F.;
Grandi, L.;
Gromov, M.;
Guan, M.;
Guardincerri, Y.;
Hackett, B. R.;
Herner, K.;
Hungerford, E. V.;
Ianni, Al.;
Ianni, An.;
James, I.;
Jollet, C.;
Keeter, K.;
Kendziora, C. L.;
Kobychev, V.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Li, X.;
Lissia, M.;
Lombardi, P.;
Luitz, S.;
Ma, Y.;
Machulin, I. N.;
Mandarano, A.;
Mari, S. M.;
Maricic, J.;
Marini, L.;
Martoff, C. J.;
Meregaglia, A.;
Meyers, P. D.;
Miletic, T.;
Milincic, R.;
Montanari, D.;
Monte, A.;
Montuschi, M.;
Monzani, M.;
Mosteiro, P.;
Mount, B. J.;
Muratova, V. N.;
Musico, P.;
Napolitano, J.;
Nelson, A.;
Odrowski, S.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pantic, E.;
Parmeggiano, S.;
Pelczar, K.;
Pelliccia, N.;
Perasso, S.;
Pocar, A.;
Pordes, S.;
Pugachev, D. A.;
Qian, H.;
Randle, K.;
Ranucci, G.;
Razeto, A.;
Reinhold, B.;
Renshaw, A. L.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Rountree, D.;
Sablone, D.;
Saggese, P.;
Saldanha, R.;
Sands, W.;
Sangiorgio, S.;
Savarese, C.;
Segreto, E.;
Semenov, D. A.;
Shields, E.;
Singh, P. N.;
Skorokhvatov, M. D.;
Smallcomb, M.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Suvorov, Y.;
Tartaglia, R.;
Tatarowicz, J.;
Testera, G.;
Tonazzo, A.;
Trinchese, P.;
Unzhakov, E. V.;
Vishneva, A.;
Vogelaar, B.;
Wada, M.;
Walker, S.;
Wang, H.;
Wang, Y.;
Watson, A. W.;
Westerdale, S.;
Wilhelmi, J.;
Wojcik, M. M.;
Xiang, X.;
Xu, J.;
Yang, C.;
Yoo, J.;
Zavatarelli, S.;
Zec, A.;
Zhong, W.;
Zhu, C.;
Zuzel, G.
Submitted: 2015-10-02, last modified: 2016-04-13
Liquid argon is a bright scintillator with potent particle identification
properties, making it an attractive target for direct-detection dark matter
searches. The DarkSide-50 dark matter search here reports the first WIMP search
results obtained using a target of low-radioactivity argon. DarkSide-50 is a
dark matter detector, using two-phase liquid argon time projection chamber,
located at the Laboratori Nazionali del Gran Sasso. The underground argon is
shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3
relative to atmospheric argon. We report a background-free null result from
(2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with
our previous search using an atmospheric argon, the 90 % C.L. upper limit on
the WIMP-nucleon spin-independent cross section based on zero events found in
the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43
cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).
[16]
oai:arXiv.org:1410.0653 [pdf] - 967593
First Results from the DarkSide-50 Dark Matter Experiment at Laboratori
Nazionali del Gran Sasso
Agnes, P.;
Alexander, T.;
Alton, A.;
Arisaka, K.;
Back, H. O.;
Baldin, B.;
Biery, K.;
Bonfini, G.;
Bossa, M.;
Brigatti, A.;
Brodsky, J.;
Budano, F.;
Cadonati, L.;
Calaprice, F.;
Canci, N.;
Candela, A.;
Cao, H.;
Cariello, M.;
Cavalcante, P.;
Chavarria, A.;
Chepurnov, A.;
Cocco, A. G.;
Crippa, L.;
D'Angelo, D.;
D'Incecco, M.;
Davini, S.;
De Deo, M.;
Derbin, A.;
Devoto, A.;
Di Eusanio, F.;
Di Pietro, G.;
Edkins, E.;
Empl, A.;
Fan, A.;
Fiorillo, G.;
Fomenko, K.;
Forster, G.;
Franco, D.;
Gabriele, F.;
Galbiati, C.;
Goretti, A.;
Grandi, L.;
Gromov, M.;
Guan, M. Y.;
Guardincerri, Y.;
Hackett, B.;
Herner, K.;
Hungerford, E. V.;
Ianni, Al.;
Ianni, An.;
Jollet, C.;
Keeter, K.;
Kendziora, C.;
Kidner, S.;
Kobychev, V.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kurlej, A.;
Li, P. X.;
Loer, B.;
Lombardi, P.;
Love, C.;
Ludhova, L.;
Luitz, S.;
Ma, Y. Q.;
Machulin, I.;
Mandarano, A.;
Mari, S.;
Maricic, J.;
Marini, L.;
Martoff, C. J.;
Meregaglia, A.;
Meroni, E.;
Meyers, P. D.;
Milincic, R.;
Montanari, D.;
Monte, A.;
Montuschi, M.;
Monzani, M. E.;
Mosteiro, P.;
Mount, B.;
Muratova, V.;
Musico, P.;
Nelson, A.;
Odrowski, S.;
Okounkova, M.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pantic, E.;
Papp, L.;
Parmeggiano, S.;
Parsells, R.;
Pelczar, K.;
Pelliccia, N.;
Perasso, S.;
Pocar, A.;
Pordes, S.;
Pugachev, D.;
Qian, H.;
Randle, K.;
Ranucci, G.;
Razeto, A.;
Reinhold, B.;
Renshaw, A.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Rountree, S. D.;
Sablone, D.;
Saggese, P.;
Saldanha, R.;
Sands, W.;
Sangiorgio, S.;
Segreto, E.;
Semenov, D.;
Shields, E.;
Skorokhvatov, M.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Suvorov, Y.;
Tartaglia, R.;
Tatarowicz, J.;
Testera, G.;
Tonazzo, A.;
Unzhakov, E.;
Vogelaar, R. B.;
Wada, M.;
Walker, S.;
Wang, H.;
Wang, Y.;
Watson, A.;
Westerdale, S.;
Wojcik, M.;
Wright, A.;
Xiang, X.;
Xu, J.;
Yang, C. G.;
Yoo, J.;
Zavatarelli, S.;
Zec, A.;
Zhu, C.;
Zuzel, G.
Submitted: 2014-10-02, last modified: 2015-02-27
We report the first results of DarkSide-50, a direct search for dark matter
operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and
searching for the rare nuclear recoils possibly induced by weakly interacting
massive particles (WIMPs). The dark matter detector is a Liquid Argon Time
Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t
organic liquid scintillator neutron veto, which is in turn installed at the
center of a 1 kt water Cherenkov veto for the residual flux of cosmic rays. We
report here the null results of a dark matter search for a (1422+-67) kg d
exposure with an atmospheric argon fill. This is the most sensitive dark matter
search performed with an argon target, corresponding to a 90% CL upper limit on
the WIMP-nucleon spin-independent cross section of 6.1x10^-44 cm^2 for a WIMP
mass of 100 GeV/c^2.
[17]
oai:arXiv.org:1412.2969 [pdf] - 925627
The Electronics and Data Acquisition System of the DarkSide Dark Matter
Search
The DarkSide Collaboration;
Agnes, P.;
Alexander, T.;
Alton, A.;
Arisaka, K.;
Back, H. O.;
Baldin, B.;
Biery, K.;
Bonfini, G.;
Bossa, M.;
Brigatti, A.;
Brodsky, J.;
Budano, F.;
Cadonati, L.;
Calaprice, F.;
Canci, N.;
Candela, A.;
Cao, H.;
Cariello, M.;
Cavalcante, P.;
Chavarria, A.;
Chepurnov, A.;
Cocco, A. G.;
Crippa, L.;
D'Angelo, D.;
D'Incecco, M.;
Davini, S.;
De Deo, M.;
Derbin, A.;
Devoto, A.;
Di Eusanio, F.;
Di Pieto, G.;
Edkins, E.;
Empl, A.;
Fan, A.;
Fiorillo, G.;
Fomenko, K.;
Forster, G.;
Franco, D.;
Gabriele, F.;
Galbiati, C.;
Goretti, A.;
Grandi, L.;
Gromov, M.;
Guan, M. Y.;
Guardincerri, Y.;
Hackett, B.;
Herner, K.;
Hungerford, E.;
Ianni, Al.;
Ianni, An.;
Jollet, C.;
Keeter, K.;
Kendziora, C.;
Kidner, S.;
Kobychev, V.;
Koh, G.;
Korablev, D.;
Korga, G.;
Kurlej, A.;
Li, P. X.;
Loer, B.;
Lombardi, P.;
Love, C.;
Ludhova, L.;
Luitz, S.;
Ma, Y. Q.;
Machulin, I.;
Mandarano, A.;
Mari, S. M.;
Maricic, J.;
Marini, L.;
Martoff, J.;
Meregaglia, A.;
Meroni, E.;
Meyers, P. D.;
Milincic, R.;
Montanari, D.;
Montuschi, M.;
Monzani, M. E.;
Mosteiro, P.;
Mount, B.;
Muratova, V.;
Musico, P.;
Nelson, A.;
Odrowski, S.;
Okounkoa, M.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Pantic, E.;
Papp, L.;
Parmeggiano, S.;
Parsells, Bob;
Pelczar, K.;
Pelliccia, N.;
Perasso, S.;
Pocar, A.;
Pordes, S.;
Pugachev, D.;
Qian, H.;
Randle, K.;
Ranucci, G.;
Razeto, A.;
Reinhold, B.;
Renshaw, A.;
Romani, A.;
Rossi, B.;
Rossi, N.;
Rountree, S. D.;
Sablone, D.;
Saggese, P.;
Saldanha, R.;
Sands, W.;
Sangiorgio, S.;
Segreto, E.;
Semenov, D.;
Shields, E.;
Skorokhvatov, M.;
Smirnov, O.;
Sotnikov, A.;
Stanford, C.;
Suvorov;
Tartaglia, R.;
Tatarowicz, J.;
Testera, G.;
Tonazzo, A.;
Unzhakov, E.;
Vogelaar, R. B.;
Wada, M.;
Walker, S. E.;
Wang, H.;
Wang, Y.;
Watson, A.;
Westerdale, S.;
Wojcik, M.;
Wright, A.;
Xiang, X.;
Xu, J.;
Yang, C. G.;
Yoo, J.;
Zavatarelli, S.;
Zec, A.;
Zhu, C.;
Zuzel, G.
Submitted: 2014-12-09, last modified: 2015-01-22
It is generally inferred from astronomical measurements that Dark Matter (DM)
comprises approximately 27\% of the energy-density of the universe. If DM is a
subatomic particle, a possible candidate is a Weakly Interacting Massive
Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for
evidence of WIMP-nuclear collisions. DS is located underground at the
Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three
active, embedded components; an outer water veto (CTF), a liquid scintillator
veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper
describes the data acquisition and electronic systems of the DS detectors,
designed to detect the residual ionization from such collisions.
[18]
oai:arXiv.org:1204.6218 [pdf] - 1118329
Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for
Dark Matter Searches
Alexander, T.;
Alton, D.;
Arisaka, K.;
Back, H. O.;
Beltrame, P.;
Benziger, J.;
Bonfini, G.;
Brigatti, A.;
Brodsky, J.;
Cadonati, L.;
Calaprice, F.;
Candela, A.;
Cao, H.;
Cavalcante, P.;
Chavarria, A.;
Chepurnov, A.;
Cline, D.;
Cocco, A. G.;
Condon, C.;
D'Angelo, D.;
Davini, S.;
De Haas, E.;
Derbin, A.;
Di Pietro, G.;
Dratchnev, I.;
Durben, D.;
Empl, A.;
Etenko, A.;
Fan, A.;
Fiorillo, G.;
Fomenko, K.;
Gabriele, F.;
Galbiati, C.;
Gazzana, S.;
Ghag, C.;
Ghiano, C.;
Goretti, A.;
Grandi, L.;
Gromov, M.;
Guan, M.;
Guo, C.;
Guray, G.;
Hungerford, E. V.;
Ianni, Al.;
Ianni, An.;
Kayunov, A.;
Keeter, K.;
Kendziora, C.;
Kidner, S.;
Kobychev, V.;
Koh, G.;
Korablev, D.;
Korga, G.;
Shields, E.;
Li, P.;
Loer, B.;
Lombardi, P.;
Love, C.;
Ludhova, L.;
Lukyanchenko, L.;
Lund, A.;
Lung, K.;
Ma, Y.;
Machulin, I.;
Maricic, J.;
Martoff, C. J.;
Meng, Y.;
Meroni, E.;
Meyers, P. D.;
Mohayai, T.;
Montanari, D.;
Montuschi, M.;
Mosteiro, P.;
Mount, B.;
Muratova, V.;
Nelson, A.;
Nemtzow, A.;
Nurakhov, N.;
Orsini, M.;
Ortica, F.;
Pallavicini, M.;
Pantic, E.;
Parmeggiano, S.;
Parsells, R.;
Pelliccia, N.;
Perasso, L.;
Perfetto, F.;
Pinsky, L.;
Pocar, A.;
Pordes, S.;
Ranucci, G.;
Razeto, A.;
Romani, A.;
Rossi, N.;
Saggese, P.;
Saldanha, R.;
Salvo, C.;
Sands, W.;
Seigar, M.;
Semenov, D.;
Skorokhvatov, M.;
Smirnov, O.;
Sotnikov, A.;
Sukhotin, S.;
Suvorov, Y.;
Tartaglia, R.;
Tatarowicz, J.;
Testera, G.;
Teymourian, A.;
Thompson, J.;
Unzhakov, E.;
Vogelaar, R. B.;
Wang, H.;
Westerdale, S.;
Wojcik, M.;
Wright, A.;
Xu, J.;
Yang, C.;
Zavatarelli, S.;
Zehfus, M.;
Zhong, W.;
Zuzel, G.
Submitted: 2012-04-27, last modified: 2013-08-14
As part of the DarkSide program of direct dark matter searches using liquid
argon TPCs, a prototype detector with an active volume containing 10 kg of
liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso
National Laboratory in Italy. A critically important parameter for such devices
is the scintillation light yield, as photon statistics limits the rejection of
electron-recoil backgrounds by pulse shape discrimination. We have measured the
light yield of DarkSide-10 using the readily-identifiable full-absorption peaks
from gamma ray sources combined with single-photoelectron calibrations using
low-occupancy laser pulses. For gamma lines of energies in the range 122-1275
keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys)
p.e./keVee. With additional purification, the light yield measured at 511 keV
increased to 9.142+-0.006(stat) p.e./keVee.
[19]
oai:arXiv.org:1202.6403 [pdf] - 1116970
Cosmic-muon flux and annual modulation in Borexino at 3800 m
water-equivalent depth
Bellini, G.;
Benziger, J.;
Bick, D.;
Bonfini, G.;
Bravo, D.;
Avanzini, M. Buizza;
Caccianiga, B.;
Cadonati, L.;
Calaprice, F.;
Carraro, C.;
Cavalcante, P.;
Chavarria, A.;
Chepurnov, A.;
D'Angelo, D.;
Davini, S.;
Derbin, A.;
Etenko, A.;
von Feilitzsch, F.;
Fomenko, K.;
Franco, D.;
Galbiati, C.;
Gazzana, S.;
Ghiano, C.;
Giammarchi, M.;
Goeger-Neff, M.;
Goretti, A.;
Grandi, L.;
Guardincerri, E.;
Hagner, C.;
Hardy, S.;
Ianni, Aldo;
Ianni, Andrea;
Korablev, D.;
Korga, G.;
Koshio, Y.;
Kryn, D.;
Laubenstein, M.;
Lewke, T.;
Litvinovich, E.;
Loer, B.;
Lombardi, F.;
Lombardi, P.;
Ludhova, L.;
Machulin, I.;
Manecki, S.;
Maneschg, W.;
Manuzio, G.;
Meindl, Q.;
Meroni, E.;
Miramonti, L.;
Misiaszek, M.;
Montanari, D.;
Mosteiro, P.;
Muratova, V.;
Oberauer, L.;
Obolensky, M.;
Ortica, F.;
Otis, K.;
Pallavicini, M.;
Papp, L.;
Perasso, L.;
Perasso, S.;
Pocar, A.;
Raghavan, R. S.;
Ranucci, G.;
Razeto, A.;
Re, A.;
Romani, A.;
Sabelnikov, A.;
Saldanha, R.;
Salvo, C.;
Schönert, S.;
Simgen, H.;
Skorokhvatov, M.;
Smirnov, O.;
Sotnikov, A.;
Sukhotin, S.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Vignaud, D.;
Vogelaar, R. B.;
Winter, J.;
Wojcik, M.;
Wright, A.;
Wurm, M.;
Xu, J.;
Zaimidoroga, O.;
Zavatarelli, S.;
Zuzel, G.
Submitted: 2012-02-28, last modified: 2012-11-22
We have measured the muon flux at the underground Gran Sasso National
Laboratory (3800 m w.e.) to be (3.41 \pm 0.01) \times 10-4m-2s-1 using four
years of Borexino data. A modulation of this signal is observed with a period
of (366\pm3) days and a relative amplitude of (1.29 \pm 0.07)%. The measured
phase is (179 \pm 6) days, corresponding to a maximum on the 28th of June.
Using the most complete atmospheric data models available, muon rate
fluctuations are shown to be positively correlated with atmospheric
temperature, with an effective coefficient {\alpha}T = 0.93 \pm 0.04. This
result represents the most precise study of the muon flux modulation for this
site and is in good agreement with expectations.
[20]
oai:arXiv.org:1205.2989 [pdf] - 511881
Solar neutrino physics with Borexino I
Ludhova, L.;
Bellini, G.;
Benziger, J.;
Bick, D.;
Bonfini, G.;
Bravo, D.;
Avanzini, M. Buizza;
Caccianiga, B.;
Cadonati, L.;
Calaprice, F.;
Carraro, C.;
Cavalcante, P.;
Chavarria, A.;
D'Angelo, D.;
Davini, S.;
Derbin, A.;
Etenko, A.;
Fomenko, K.;
Franco, D.;
Galbiati, C.;
Gazzana, S.;
Ghiano, C.;
Giammarchi, M.;
Goeger-Nef, M.;
Goretti, A.;
Grandi, L.;
Guardincerri, E.;
Hardy, S.;
Ianni, Aldo;
Ianni, Andrea;
Kayunov, A.;
Kobychev, V.;
Korablev, D.;
Korga, G.;
Koshio, Y.;
Kryn, D.;
Laubenstein, M.;
Lewke, T.;
Litvinovich, E.;
Loer, B.;
Lombardi, F.;
Lombardi, P.;
Machulin, I.;
Manecki, S.;
Maneschg, W.;
Manuzio, G.;
Meindl, Q.;
Meroni, E.;
Miramonti, L.;
Misiaszek, M.;
Montanari, D.;
Mosteiro, P.;
Muratova, V.;
Oberauer, L.;
Obolenksy, M.;
Ortica, F.;
Otis, K.;
Pallavicini, M.;
Papp, L.;
Perasso, L.;
Perasso, S.;
Pocar, A.;
Raghavan, R. S.;
Ranucci, G.;
Razeto, A.;
Re, A.;
Romani, P. A.;
Sabelnikov, A.;
Saldanha, R.;
Salvo, C.;
Schoenert, S.;
Simgen, H.;
Skorokhvatov, M.;
Smirnov, O.;
Sotnikov, A.;
Sukhotin, S.;
Suvorov, Y.;
Tartaglia, R.;
Testera, G.;
Vignaud, D.;
Vogelaar, R. B.;
Von Feilitzsch, F.;
Winter, J.;
Wojcik, M.;
Wright, A.;
Wurm, M.;
Xu, J.;
Zaimidoroga, O.;
Zavatarelli, S.;
Zuzel, G.
Submitted: 2012-05-14
Borexino is a large-volume liquid scintillator detector installed in the
underground halls of the Laboratori Nazionali del Gran Sasso in Italy. After
several years of construction, data taking started in May 2007. The Borexino
phase I ended after about three years of data taking. Borexino provided the
first real time measurement of the $^{7}$Be solar neutrino interaction rate
with accuracy better than 5% and confirmed the absence of its day-night
asymmetry with 1.4% precision. This latter Borexino results alone rejects the
LOW region of solar neutrino oscillation parameters at more than 8.5 $\sigma$
C.L. Combined with the other solar neutrino data, Borexino measurements isolate
the MSW-LMA solution of neutrino oscillations without assuming CPT invariance
in the neutrino sector. Borexino has also directly observed solar neutrinos in
the 1.0-1.5 MeV energy range, leading to the first direct evidence of the $pep$
solar neutrino signal and the strongest constraint of the CNO solar neutrino
flux up to date. Borexino provided the measurement of the solar $^{8}$B
neutrino rate with 3 MeV energy threshold.
[21]
oai:arXiv.org:1108.5584 [pdf] - 1083670
Demonstration and Comparison of Operation of Photomultiplier Tubes at
Liquid Argon Temperature
Acciarri, R.;
Antonello, M.;
Boffelli, F.;
Cambiaghi, M.;
Canci, N.;
Cavanna, F.;
Cocco, A. G.;
Deniskina, N.;
Di Pompeo, F.;
Fiorillo, G.;
Galbiati, C.;
Grandi, L.;
Kryczynski, P.;
Meng, G.;
Montanari, C.;
Palamara, O.;
Pandola, L.;
Perfetto, F.;
Mortari, G. B. Piano;
Pietropaolo, F.;
Raselli, G. L.;
Rossella, M.;
Rubbia, C.;
Segreto, E.;
Szelc, A. M.;
Triossi, A.;
Ventura, S.;
Vignoli, C.;
Zani, A.
Submitted: 2011-08-29, last modified: 2011-09-26
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments.
[22]
oai:arXiv.org:astro-ph/0701286 [pdf] - 88415
First results from a Dark Matter search with liquid Argon at 87 K in the
Gran Sasso Underground Laboratory
Benetti, P.;
Acciarri, R.;
Adamo, F.;
Baibussinov, B.;
Baldo-Ceolin, M.;
Belluco, M.;
Calaprice, F.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cavanna, F.;
Centro, S.;
Cocco, A. G.;
Di Pompeo, F.;
Ferrari, N.;
Fiorillo, G.;
Galbiati, C.;
Gallo, V.;
Grandi, L.;
Ianni, A.;
Mangano, G.;
Meng, G.;
Montanari, C.;
Palamara, O.;
Pandola, L.;
Pietropaolo, F.;
Raselli, G. L.;
Rossella, M.;
Rubbia, C.;
Szelc, A. M.;
Ventura, S.;
Vignoli, C.
Submitted: 2007-01-10, last modified: 2007-01-16
A new method of searching for dark matter in the form of weakly interacting
massive particles (WIMP) has been developed with the direct detection of the
low energy nuclear recoils observed in a massive target (ultimately many tons)
of ultra pure Liquid Argon at 87 K. A high selectivity for Argon recoils is
achieved by the simultaneous observation of both the VUV scintillation
luminescence and of the electron signal surviving columnar recombination,
extracted through the liquid-gas boundary by an electric field. First physics
results from this method are reported, based on a small 2.3 litre test chamber
filled with natural Argon and an accumulated fiducial exposure of about 100 kg
x day, supporting the future validity of this method with isotopically purified
40Ar and for a much larger unit presently under construction with
correspondingly increased sensitivities.
[23]
oai:arXiv.org:astro-ph/0603131 [pdf] - 80340
Measurement of the specific activity of Ar-39 in natural argon
Benetti, P.;
Calaprice, F.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cavanna, F.;
Cocco, A. G.;
Di Pompeo, F.;
Ferrari, N.;
Fiorillo, G.;
Galbiati, C.;
Grandi, L.;
Mangano, G.;
Montanari, C.;
Pandola, L.;
Rappoldi, A.;
Raselli, G. L.;
Roncadelli, M.;
Rossella, M.;
Rubbia, C.;
Santorelli, R.;
Szelc, A. M.;
Vignoli, C.;
Zhao, Y.
Submitted: 2006-03-06, last modified: 2007-01-10
We report on the measurement of the specific activity of Ar-39 in natural
argon. The measurement was performed with a 2.3-liter two-phase (liquid and
gas) argon drift chamber. The detector was developed by the WARP Collaboration
as a prototype detector for WIMP Dark Matter searches with argon as a target.
The detector was operated for more than two years at Laboratori Nazionali del
Gran Sasso, Italy, at a depth of 3,400 m w.e. The specific activity measured
for Ar-39 is 1.01 +/- 0.02(stat) +/- 0.08(syst) Bq per kg of natural Ar.
[24]
oai:arXiv.org:astro-ph/0411491 [pdf] - 1507895
WARP: a WIMP double phase Argon detector
Brunetti, R.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cavanna, F.;
Cocco, A.;
De Vecchi, C.;
Dolfini, R.;
Ereditato, A.;
Ferrari, N.;
Fiorillo, G.;
Grandi, L.;
Mangano, G.;
Menegolli, A.;
Montanari, C.;
Palamara, O.;
Prata, M.;
Rappoldi, A.;
Raselli, G. L.;
Roncadelli, M.;
Rossella, M.;
Rubbia, C.;
Santorelli, R.;
Vignoli, C.
Submitted: 2004-11-17
The WARP programme for dark matter search with a double phase argon detector
is presented. In such a detector both excitation and ionization produced by an
impinging particle are evaluated by the contemporary measurement of primary
scintillation and secondary (proportional) light signal, this latter being
produced by extracting and accelerating ionization electrons in the gas phase.
The proposed technique, verified on a 2.3 liters prototype, could be used to
efficiently discriminate nuclear recoils, induced by WIMP's interactions, and
measure their energy spectrum. An overview of the 2.3 liters results and of the
proposed 100 liters detector is shown.
[25]
oai:arXiv.org:astro-ph/0405342 [pdf] - 64862
WARP liquid argon detector for dark matter survey
Brunetti, R.;
Calligarich, E.;
Cambiaghi, M.;
Carbonara, F.;
Cocco, A.;
De Vecchi, C.;
Dolfini, R.;
Ereditato, A.;
Fiorillo, G.;
Grandi, L.;
Mangano, G.;
Menegolli, A.;
Montanari, C.;
Prata, M.;
Rappoldi, A.;
Raselli, G. L.;
Roncadelli, M.;
Rossella, M.;
Rubbia, C.;
Santorelli, R.;
Vignoli, C.
Submitted: 2004-05-18
The WARP programme is a graded programme intended to search for cold Dark
Matter in the form of WIMP's. These particles may produce via weak interactions
nuclear recoils in the energy range 10-100 keV. A cryogenic noble liquid like
argon, already used in the realization of very large detector, permits the
simultaneous detection of both ionisation and scintillation induced by an
interaction, suggesting the possibility of discriminating between nuclear
recoils and electrons mediated events. A 2.3 litres two-phase argon detector
prototype has been used to perform several tests on the proposed technique.
Next step is the construction of a 100 litres sensitive volume device with
potential sensitivity a factor 100 better than presently existing experiments.