Normalized to: Gottardi, L.
[1]
oai:arXiv.org:2003.11899 [pdf] - 2070581
Progress in the development of frequency domain multiplexing for the
X-ray Integral Field Unit on board the Athena mission
Akamatsu, H.;
Gottardi, L.;
van der Kuur, J.;
de Vries, C. P.;
Bruijn, M. P.;
Chervenak, J. A.;
Kiviranta, M.;
Linden, A. J. van den;
Jackson, B. D.;
Miniussi, A.;
Ravensberg, K.;
Sakai, K.;
Smith, S. J.;
Wakeham, N.
Submitted: 2020-03-26
Frequency domain multiplexing (FDM) is the baseline readout system for the
X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM
scheme, TESs are coupled to a passive LC filter and biased with alternating
current (AC bias) at MHz frequencies. Using high-quality factor LC filters and
room temperature electronics developed at SRON and low-noise two-stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have
achieved a performance requested for the demonstration model (DM) with the
single pixel AC bias ($\Delta E=$1.8 eV) and 9 pixel multiplexing ($\Delta
E=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an
average energy resolution of 3.3 eV, which is limited by non-fundamental issues
related to FDM readout in our lab setup.
[2]
oai:arXiv.org:1805.06215 [pdf] - 1684638
Proximity effect model for x-ray Transition Edge Sensors
Submitted: 2018-05-16, last modified: 2018-05-17
Transition Edge Sensors are ultra-sensitive superconducting detectors with
applications in many areas of research, including astrophysics. The device
consists of a superconducting thin film, often with additional normal metal
features, held close to its transition temperature and connected to two
superconducting leads of a higher transition temperature. There is currently no
way to reliably assess the performance of a particular device geometry or
material composition without making and testing the device. We have developed a
proximity effect model based on the Usadel equations to predict the effects of
device geometry and material composition on sensor performance. The model is
successful in reproducing I-V curves for two devices currently under study. We
use the model to suggest the optimal size and geometry for TESs, considering
how small the devices can be made before their performance is compromised. In
the future, device modelling prior to manufacture will reduce the need for
time-consuming and expensive testing.
[3]
oai:arXiv.org:1611.05268 [pdf] - 1515839
Optimising the multiplex factor of the frequency domain multiplexed
readout of the TES-based microcalorimeter imaging array for the X-IFU
instrument on the Athena Xray observatory
Submitted: 2016-11-16
Athena is a space-based X-ray observatory intended for exploration of the hot
and energetic universe. One of the science instruments on Athena will be the
X-ray Integrated Field Unit (X-IFU), which is a cryogenic X-ray spectrometer,
based on a large cryogenic imaging array of Transition Edge Sensors (TES) based
microcalorimeters operating at a temperature of 100mK. The imaging array
consists of 3800 pixels providing 2.5 eV spectral resolution, and covers a
field of view with a diameter of of 5 arc minutes. Multiplexed readout of the
cryogenic microcalorimeter array is essential to comply with the cooling power
and complexity constraints on a space craft. Frequency domain multiplexing has
been under development for the readout of TES-based detectors for this purpose,
not only for the X-IFU detector arrays but also for TES-based bolometer arrays
for the Safari instrument of the Japanese SPICA observatory. This paper
discusses the design considerations which are applicable to optimise the
multiplex factor within the boundary conditions as set by the space craft. More
specifically, the interplay between the science requirements such as pixel
dynamic range, pixel speed, and cross talk, and the space craft requirements
such as the power dissipation budget, available bandwidth, and electromagnetic
compatibility will be discussed.
[4]
oai:arXiv.org:1611.00956 [pdf] - 1521434
Development of frequency domain multiplexing for the X-ray Integral
Field Unit (X-IFU) on the Athena
Akamatsu, Hiroki;
Gottardi, Luciano;
van der Kuur, Jan;
de Vries, Cor P.;
Ravensberg, Kevin;
Adams, Joseph S.;
Bandler, Simon R.;
Bruijn, Marcel P.;
Chervenak, James A.;
Kilbourne, Caroline A;
Kiviranta, Mikko;
Linden, A. J. van den;
Jackson, Brian D.;
Smith, Stephen J.
Submitted: 2016-11-03
We are developing the frequency domain multiplexing (FDM) read-out of
transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field
Unit (X-IFU) instrument on board of the future European X-Ray observatory
Athena. The X-IFU instrument consists of an array of $\sim$3840 TESs with a
high quantum efficiency ($>$90 \%) and spectral resolution $\Delta E$=2.5 eV
$@$ 7 keV ($E/\Delta E\sim$2800). FDM is currently the baseline readout system
for the X-IFU instrument. Using high quality factor LC filters and room
temperature electronics developed at SRON and low-noise two stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. An integrated
noise equivalent power resolution of about 2.0 eV at 1.7 MHz has been
demonstrated with a pixel from a new TES array from NASA/Goddard (GSFC-A2). We
have achieved X-ray energy resolutions $\sim$2.5 eV at AC bias frequency at 1.7
MHz in the single pixel read-out. We have also demonstrated for the first time
an X-ray energy resolution around 3.0 eV in a 6 pixel FDM read-out with TES
array (GSFC-A1). In this paper we report on the single pixel performance of
these microcalorimeters under MHz AC bias, and further results of the
performance of these pixels under FDM.
[5]
oai:arXiv.org:1607.00834 [pdf] - 1521238
Microcalorimeter pulse analysis by means of principle component
decomposition
Submitted: 2016-07-04
The X-ray integral field unit for the Athena mission consists of a
microcalorimeter transition edge sensor pixel array. Incoming photons generate
pulses which are analyzed in terms of energy, in order to assemble the X-ray
spectrum. Usually this is done by means of optimal filtering in either time or
frequency domain.
In this paper we investigate an alternative method by means of principle
component analysis. This method attempts to find the main components of an
orthogonal set of functions to describe the data.
We show, based on simulations, what the influence of various instrumental
effects is on this type of analysis. We compare analyses both in time and
frequency domain. Finally we apply these analyses on real data, obtained via
frequency domain multiplexing readout.
[6]
oai:arXiv.org:1604.02593 [pdf] - 1388308
AC bias characterization of low noise bolometers for SAFARI using an
Open-Loop Frequency Domain SQUID-based multiplexer operating between 1 and 5
MHz
Gottardi, Luciano;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
de Korte, Piet;
van der Kuur, Jan;
Lindeman, Mark;
Ridder, Marcel
Submitted: 2016-04-09
SRON is developing the Frequency Domain Multiplexing (FDM) readout and the
ultra low NEP TES bolometers array for the infrared spectrometer SAFARI on
board of the Japanese space mission SPICA. The FDM prototype of the instrument
requires critical and complex optimizations. For single pixel characterization
under AC bias we are developing a simple FDM system working in the frequency
range from 1 to 5 MHz, based on the open loop read-out of a linearized
two-stage SQUID amplifier and high Q lithographic LC resonators. We describe
the details of the experimental set-up required to achieve low power loading (<
1 fW) and low noise (NEP $\sim 10^{-19} W/Hz^{1/2}$) in the TES bolometers. We
conclude the paper by comparing the performance of a $4 \cdot 10^{-19}
W/Hz^{1/2}$ TES bolometer measured under DC and AC bias.
[7]
oai:arXiv.org:1604.02600 [pdf] - 1388309
A multiplexer for the ac/dc characterization of TES based bolometers and
microcalorimeters
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
van der Kuur, Jan;
van der Linden, Anoton;
Lindeman, Marcel;
Ridder, Marcel
Submitted: 2016-04-09
At SRON we are developing the Frequency Domain Multiplexing (FDM) for the
read-out of the TES-based detector array for the future infrared and X-ray
space mission. We describe the performances of a multiplexer designed to
increase the experimental throughput in the characterisation of ultra-low noise
equivalent power (NEP) TES bolometers and high energy resolving power X-ray
microcalorimeters arrays under ac and dc bias. We discuss the results obtained
using the TiAu TES bolometers array fabricated at SRON with measured dark NEP
below $5\cdot 10^{-19}W/Hz^{1/2}$ and saturation power of several fW
[8]
oai:arXiv.org:1604.00670 [pdf] - 1489757
Development of the superconducting detectors and read-out for the X-IFU
instrument on board of the X-ray observatory Athena
Submitted: 2016-04-03
The Advanced Telescope for High-Energy Astrophysics (Athena) has been
selected by ESA as its second large-class mission. The future European X-ray
observatory will study the hot and energetic Universe with its launch foreseen
in 2028. Microcalorimeters based on superconducting Transition-edge sensor
(TES) are the chosen technology for the detectors array of the X-ray Integral
Field Unit (X-IFU) on board of Athena. The X-IFU is a 2-D imaging
integral-field spectrometer operating in the soft X-ray band (0.3 -12 keV). The
detector consists of an array of 3840 TESs coupled to X-ray absorbers and read
out in the MHz bandwidth using Frequency Domain Multiplexing (FDM) based on
Superconducting QUantum Interference Devices (SQUIDs). The proposed design
calls for devices with a high filling-factor, high quantum efficiency,
relatively high count-rate capability and an energy resolution of 2.5 eV at 5.9
keV. The paper will review the basic principle and the physics of the TES-based
microcalorimeters and present the state-of-the art of the FDM read-out.
[9]
oai:arXiv.org:1604.00680 [pdf] - 1384872
Weak-Link Phenomena in AC-Biased Transition Edge Sensors
Gottardi, Luciano;
Akamatsu, Hiroki;
Bruijn, Marcel;
Gao, Jan-R.;
Hartog, Roland den;
Hijmering, Richard;
Hoevers, Henk;
Khosropanah, Pourya;
Kozorezov, Alex;
van der Kuur, Jan;
van der Linden, Anton;
Ridder, Marcel
Submitted: 2016-04-03
It has been recently demonstrated that superconducting transition edge
sensors (TESs) behave as weak-links due to longitudinally induced
superconductivity from the leads with higher Tc. In this work we study the
implication of this behaviour for TES-based bolometers and microcalorimeter
under ac bias. The TESs are read-out at frequencies between 1 and 5 MHz by a
Frequency Domain Multiplexer based on a linearised two-stage SQUID amplifier
and high- Q lithographically made superconducting LC resonators. In particular,
we focus on SRON TiAu TES bolometers with a measured dark Noise Equivalent
Power (NEP) of $3.2 \cdot 10^{-19} W/Hz^{1/2}$ developed for the short
wavelength band for the instrument SAFARI on the SPICA telescope.
[10]
oai:arXiv.org:1604.00553 [pdf] - 1384861
Development of TES-based detectors array for the X-ray Integral Field
Unit (X-IFU) on the future x-ray observatory ATHENA
Gottardi, Luciano;
Akamatsu, Hiroki;
Barret, Didier;
Bruijn, Marcel P.;
Hartog, Roland H. den;
Herder, Jan-Willem den;
Hoevers, Henk F. C.;
Kiviranta, Mikko;
van der Kuur, Jan;
van der Linden, Anton J.;
Jackson, Brian D.;
Jambunathan, Madu;
Ridder, Marcel L.
Submitted: 2016-04-02
We are developing transition-edge sensor (TES)-based microcalorimeters for
the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory
Athena. The microcalorimeters are based on TiAu TESs coupled to 250{\mu}m
squared, AuBi absorbers. We designed and fabricated devices with different
contact geometries between the absorber and the TES to optimise the detector
performance and with different wiring topology to mitigate the self-magnetic
field. The design is tailored to optimise the performance under Frequency
Domain Multiplexing. In this paper we review the main design feature of the
pixels array and we report on the performance of the 18 channels, 2-5MHz
frequency domain multiplexer that will be used to characterised the detector
array.
[11]
oai:arXiv.org:1308.6784 [pdf] - 713384
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU)
for Athena+
Barret, D.;
Herder, J. W. den;
Piro, L.;
Ravera, L.;
Hartog, R. Den;
Macculi, C.;
Barcons, X.;
Page, M.;
Paltani, S.;
Rauw, G.;
Wilms, J.;
Ceballos, M.;
Duband, L.;
Gottardi, L.;
Lotti, S.;
de Plaa, J.;
Pointecouteau, E.;
Schmid, C.;
Akamatsu, H.;
Bagliani, D.;
Bandler, S.;
Barbera, M.;
Bastia, P.;
Biasotti, M.;
Branco, M.;
Camon, A.;
Cara, C.;
Cobo, B.;
Colasanti, L.;
Costa-Kramer, J. L.;
Corcione, L.;
Doriese, W.;
Duval, J. M.;
Fabrega, L.;
Gatti, F.;
de Gerone, M.;
Guttridge, P.;
Kelley, R.;
Kilbourne, C.;
van der Kuur, J.;
Mineo, T.;
Mitsuda, K.;
Natalucci, L.;
Ohashi, T.;
Peille, P.;
Perinati, E.;
Pigot, C.;
Pizzigoni, G.;
Pobes, C.;
Porter, F.;
Renotte, E.;
Sauvageot, J. L.;
Sciortino, S.;
Torrioli, G.;
Valenziano, L.;
Willingale, D.;
de Vries, C.;
van Weers, H.
Submitted: 2013-08-30
The Athena+ mission concept is designed to implement the Hot and Energetic
Universe science theme submitted to the European Space Agency in response to
the call for White Papers for the definition of the L2 and L3 missions of its
science program. The Athena+ science payload consists of a large aperture high
angular resolution X-ray optics and twelve meters away, two interchangeable
focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide
Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a
large array of Transition Edge Sensors (TES), offering 2.5 eV spectral
resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter.
In this paper, we briefly describe the Athena+ mission concept and the X-IFU
performance requirements. We then present the X-IFU detector and readout
electronics principles, the current design of the focal plane assembly, the
cooling chain and review the global architecture design. Finally, we describe
the current performance estimates, in terms of effective area, particle
background rejection, count rate capability and velocity measurements. Finally,
we emphasize on the latest technology developments concerning TES array
fabrication, spectral resolution and readout performance achieved to show that
significant progresses are being accomplished towards the demanding X-IFU
requirements.