Normalized to: Gothe, K.
[1]
oai:arXiv.org:1902.01081 [pdf] - 1851680
VHE Gamma-ray Observation of Crab Nebula with HAGAR Telescope Array
Singh, B. B.;
Britto, R. J.;
Chitnis, V. R.;
Shukla, A.;
Saha, L.;
Sinha, A.;
Acharya, B. S.;
Vishwanath, P. R.;
Anupama, G. C.;
Bhattacharjee, P.;
Gothe, K. S.;
Nagesh, B. K.;
Prabhu, T. P.;
Rao, S. K;
Srinivasan, R.;
Upadhya, S. S.
Submitted: 2019-02-04
HAGAR is a system of seven Non-imaging Atmospheric Cherenkov Telescopes
located at Hanle in the Ladakh region of the Indian Himalayas at an altitude of
4270 meters {\it amsl}. Since 2008, we have observed the Crab Nebula to assess
the performance of the HAGAR telescopes. We describe the analysis technique for
the estimation of $\gamma$-ray signal amidst cosmic ray background. The
consolidated results spanning nine years of the Crab nebula observations show
long term performance of the HAGAR telescopes. Based on about 219 hours of
data, we report the detection of $\gamma$-rays from the Crab Nebula at a
significance level of about 20$\sigma$, corresponding to a time averaged flux
of (1.64$\pm$0.09) $\times10^{-10}$ photons cm$^{-2}$ sec$^{-1}$ above 230 GeV.
Also, we perform a detailed study of possible systematic effects in our
analysis method on data taken with the HAGAR telescopes.
[3]
oai:arXiv.org:1708.09289 [pdf] - 1587688
Test results of a prototype device to calibrate the Large Size Telescope
camera proposed for the Cherenkov Telescope Array
Palatiello, Michele;
Cauz, Diego;
De Persio, Fulvio;
Ferrarotto, Fabrizio;
Paoletta, Giovanni;
Iori, Maurizio;
Majumdar, P.;
Chatterjee, A.;
Chitnis, V.;
Singh, B. B.;
Gothe, K.;
Manoranjan, M.
Submitted: 2017-08-30, last modified: 2017-09-19
A Large Size air Cherenkov Telescope (LST) prototype, proposed for the
Cherenkov Telescope Array (CTA), is under construction at the Canary Island of
La Palma (Spain) this year. The LST camera, which comprises an array of about
500 photomultipliers (PMTs), requires a precise and regular calibration over a
large dynamic range, up to $10^3$ photo-electrons (pe's), for each PMT. We
present a system built to provide the optical calibration of the camera
consisting of a pulsed laser (355 nm wavelength, 400 ps pulse width), a set of
filters to guarantee a large dynamic range of photons on the sensors, and a
diffusing sphere to uniformly spread the laser light, with flat fielding within
3%, over the camera focal plane 28 m away. The prototype of the system
developed at INFN is hermetically closed and filled with dry air to make the
system completely isolated from the external environment. In the paper we
present the results of the tests for the evaluation of the photon density at
the camera plane, the system isolation from the environment, and the shape of
the signal as detected by the PMTs. The description of the communication of the
system with the rest of detector is also given.
[7]
oai:arXiv.org:astro-ph/0109003 [pdf] - 44502
Distributed Data Acquisition System for Pachmarhi Array of Cerenkov
Telescopes
Bhat, P. N.;
Acharya, B. S.;
Chitnis, V. R.;
D'Souza, A. I.;
Francis, P. J.;
Gothe, K. S.;
Joshi, S. R.;
Majumdar, P.;
Nagesh, B. K.;
Pose, M. S.;
Purohit, P. N.;
Rahman, M. A.;
Rao, K. K.;
Rao, S. K.;
Sharma, S. K.;
Singh, B. B.;
Stanislaus, A. J.;
Sudershanan, P. V.;
Upadhyaya, S. S.;
Murthy, B. L. V.;
Vishwanath, P. R.
Submitted: 2001-09-01
Pachmarhi Array of \v Cerenkov Telescopes (PACT) consists of a 5$\times$5
array of \v Cerenkov telescopes deployed over an area of 100 $m$ $\times$ 80
$m$, in the form of a rectangular matrix. The experiment is based on
atmospheric \v Cerenkov technique using wavefront sampling technique. Each
telescope consists of 7 parabolic mirrors mounted para-axially on an equatorial
mount. At the focus of each mirror a fast phototube is mounted. In this
experiment a large number of parameters have to be measured and recorded from
each of the 175 phototubes in the shortest possible time. Further, the counting
rates from each phototube as well as the analog sum of the 7 phototubes from
each telescope (royal sum) need to be monitored at regular intervals during the
run. In view of the complexity of the system, the entire array is divided into
four smaller sectors each of which is handled by an independent field signal
processing centre (FSPC) housed in a control room that collects, processes and
records information from nearby six telescopes that belong to that sector. The
distributed data acquisition system (DDAS) developed for the purpose consists
of stand-alone sector data acquisition system (SDAS) in each of the four FSPC's
and a master data acquisition system (MDAS). MDAS running in the master signal
processing centre (MSPC) records data from each of the 25 telescopes. The data
acquisition and monitoring PCs (SDAS and MDAS) are networked through LAN. The
entire real time software for DDAS is developed in C under $linux$ environment.
Most of the hardware in DDAS are designed and fabricated in-house. The design
features and the performance of the entire system along with some other
auxiliary systems to facilitate the entire observations will be presented.
[8]
oai:arXiv.org:astro-ph/0108455 [pdf] - 44431
Pachmarhi Array of \v{C}erenkov Telescopes and its Sensitivity
Chitnis, V. R.;
Acharya, B. S.;
Bhat, P. N.;
Gothe, K. S.;
John, A. V.;
Majumdar, P.;
Nagesh, B. K.;
Rahman, M. A.;
Singh, B. B.;
Upadhyaya, S. S.;
Murthy, B. L. V.;
Vishwanath, P. R.
Submitted: 2001-08-28
Pachmarhi Array of \v{C}erenkov Telescopes (PACT) has been designed to search
for celestial TeV $\gamma-$rays using the wavefront sampling technique. PACT,
located at Pachmarhi, (latitude 22$^\circ$ 28$^\prime$ N, longitude 76$^\circ$
26$^\prime$ E, altitude 1075 m) consists of 25 telescopes deployed over an area
of 80 m $\times$ 100m. Each telescopes consists of 7 parabolic reflectors, each
viewed by a fast phototube behind a 3$^\circ$ mask at the focus. The density
and the arrival time of the photons at the PMT are recorded for each shower.
The energy threshold and collection area of the array are estimated, from Monte
Carlo simulations, to be $\sim$ 900 GeV and 10$^5$ m$^2$ respectively. The
accuracy in determination of arrival angle of a shower is estimated to be about
0.1$^\circ$ in the near vertical direction. About 99% of the off-axis hadronic
events could be rejected from directional information alone. Further, at least
75% of the on-axis hadronic events could be rejected using species sensitive
parameters derived from timing and density measurements. These cuts on data to
reject background would retain $\sim$ 44% of the $\gamma-$ray signal. The
sensitivity of the array for a 5$\sigma$ detection of $\gamma-$ray signal at a
threshold energy of 1 TeV has been estimated to be $\sim$ 4.1 $\times$
10$^{-12}$ photons cm$^{-2}$ s$^{-1}$ for an on source exposure of 50 hours.
The PACT set-up has been fully commissioned and is collecting data. The details
of the system parameters and sensitivity will be presented.