Normalized to: Gomes, N.
[1]
oai:arXiv.org:1812.06191 [pdf] - 1806287
Why Chromatic Imaging Matters
Sanchez-Bermudez, Joel;
Millour, Florentin;
Baron, Fabien;
van Boekel, Roy;
Bourgès, Laurent;
Duvert, Gilles;
Garcia, Paulo J. V.;
Gomes, Nuno;
Hofmann, Karl-Heinz;
Henning, Thomas;
Isbell, Jacob W.;
Lopez, Bruno;
Matter, Alexis;
Pott, J-Uwe;
Schertl, Dieter;
Thiébaut, Eric;
Weigelt, Gerd;
Young, John
Submitted: 2018-12-14
During the last two decades, the first generation of beam combiners at the
Very Large Telescope Interferometer has proved the importance of optical
interferometry for high-angular resolution astrophysical studies in the near-
and mid-infrared. With the advent of 4-beam combiners at the VLTI, the u-v
coverage per pointing increases significantly, providing an opportunity to use
reconstructed images as powerful scientific tools. Therefore, interferometric
imaging is already a key feature of the new generation of VLTI instruments, as
well as for other interferometric facilities like CHARA and JWST. It is thus
imperative to account for the current image reconstruction capabilities and
their expected evolutions in the coming years. Here, we present a general
overview of the current situation of optical interferometric image
reconstruction with a focus on new wavelength-dependent information,
highlighting its main advantages and limitations. As an Appendix we include
several cookbooks describing the usage and installation of several state-of-the
art image reconstruction packages. To illustrate the current capabilities of
the software available to the community, we recovered chromatic images, from
simulated MATISSE data, using the MCMC software SQUEEZE. With these images, we
aim at showing the importance of selecting good regularization functions and
their impact on the reconstruction.
[2]
oai:arXiv.org:1611.06155 [pdf] - 1532711
Assessing the quality of restored images in optical long-baseline
interferometry
Submitted: 2016-11-18, last modified: 2017-02-20
Assessing the quality of aperture synthesis maps is relevant for benchmarking
image reconstruction algorithms, for the scientific exploitation of data from
optical long-baseline interferometers, and for the design/upgrade of
new/existing interferometric imaging facilities. Although metrics have been
proposed in these contexts, no systematic study has been conducted on the
selection of a robust metric for quality assessment. This article addresses the
question: what is the best metric to assess the quality of a reconstructed
image? It starts by considering several metrics, and selecting a few based on
general properties. Then, a variety of image reconstruction cases is
considered. The observational scenarios are phase closure and phase referencing
at the Very Large Telescope Interferometer (VLTI), for a combination of two,
three, four and six telescopes. End-to-end image reconstruction is accomplished
with the MiRA software, and several merit functions are put to test. It is
found that convolution by an effective point spread function is required for
proper image quality assessment. The effective angular resolution of the images
is superior to naive expectation based on the maximum frequency sampled by the
array. This is due to the prior information used in the aperture synthesis
algorithm and to the nature of the objects considered. The l1 norm is the most
robust of all considered metrics, because being linear it is less sensitive to
image smoothing by high regularisation levels. For the cases considered, this
metric allows the implementation of automatic quality assessment of
reconstructed images, with a performance similar to human selection.
[3]
oai:arXiv.org:1012.1321 [pdf] - 955720
First results from fringe tracking with the PRIMA fringe sensor unit
Sahlmann, J.;
Abuter, R.;
Menardi, S.;
Schmid, C.;
Di Lieto, N.;
Delplancke, F.;
Frahm, R.;
Gomes, N.;
Haguenauer, P.;
Leveque, S.;
Morel, S.;
Mueller, A.;
Duc, T. Phan;
Schuhler, N.;
van Belle, G.
Submitted: 2010-12-06
The fringe sensor unit (FSU) is the central element of the phase referenced
imaging and micro-arcsecond astrometry (PRIMA) dual-feed facility for the Very
Large Telescope interferometer (VLTI). It has been installed at the Paranal
observatory in August 2008 and is undergoing commissioning and preparation for
science operation. Commissioning observations began shortly after installation
and first results include the demonstration of spatially encoded fringe sensing
and the increase in VLTI limiting magnitude for fringe tracking. However,
difficulties have been encountered because the FSU does not incorporate
real-time photometric correction and its fringe encoding depends on
polarisation. These factors affect the control signals, especially their
linearity, and can disturb the tracking control loop. To account for this,
additional calibration and characterisation efforts are required. We outline
the instrument concept and give an overview of the commissioning results
obtained so far. We describe the effects of photometric variations and
beam-train polarisation on the instrument operation and propose possible
solutions. Finally, we update on the current status in view of the start of
astrometric science operation with PRIMA.