sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Gom, B.

Normalized to: Gom, B.

4 article(s) in total. 73 co-authors, from 1 to 4 common article(s). Median position in authors list is 11,5.

[1]  oai:arXiv.org:2005.12459  [pdf] - 2120013
The Herschel SPIRE Fourier Transform Spectrometer Spectral Feature Finder I. The Spectral Feature Finder and Catalogue
Comments: 20 pages, 8 figures, 8 tables, final version accepted by MNRAS June 2020
Submitted: 2020-05-25, last modified: 2020-06-05
We provide a detailed description of the Herschel-SPIRE Fourier Transform Spectrometer (FTS) Spectral Feature Finder (FF). The FF is an automated process designed to extract significant spectral features from SPIRE FTS data products. Optimising the number of features found in SPIRE-FTS spectra is challenging. The wide SPIRE-FTS frequency range (447-1568 GHz) leads to many molecular species and atomic fine structure lines falling within the observed bands. As the best spectral resolution of the SPIRE-FTS is ~1.2 GHz, there can be significant line blending, depending on the source type. In order to find, both efficiently and reliably, features in spectra associated with a wide range of sources, the FF iteratively searches for peaks over a number of signal-to-noise ratio (SNR) thresholds. For each threshold, newly identified features are rigorously checked before being added to the fitting model. At the end of each iteration, the FF simultaneously fits the continuum and features found, with the resulting residual spectrum used in the next iteration. The final FF products report the frequency of the features found and the associated SNRs. Line flux determination is not included as part of the FF products, as extracting reliable line flux from SPIRE-FTS data is a complex process that requires careful evaluation and analysis of the spectra on a case-by-case basis. The FF results are 100% complete for features with SNR greater than 10 and 50-70% complete at SNR of 5. The FF code and all FF products are publicly available via the Herschel Science Archive.
[2]  oai:arXiv.org:1303.6331  [pdf] - 730563
Astronomical imaging Fourier spectroscopy at far-infrared wavelengths
Comments: 10 pages; 9 figures. Accepted for publication in the Canadian Journal of Physics. v2: minor typographical changes to match published version
Submitted: 2013-03-25, last modified: 2013-05-02
The principles and practice of astronomical imaging Fourier transform spectroscopy (FTS) at far-infrared wavelengths are described. The Mach-Zehnder interferometer design has been widely adopted for current and future imaging FTS instruments; we compare this design with two other common interferometer formats. Examples of three instruments based on the Mach-Zehnder design are presented. The techniques for retrieving astrophysical parameters from the measured spectra are discussed using calibration data obtained with the Herschel SPIRE instrument. The paper concludes with an example of imaging spectroscopy obtained with the SPIRE FTS instrument.
[3]  oai:arXiv.org:1010.1887  [pdf] - 1041179
Calibration of the AKARI Far-Infrared Imaging Fourier Transform Spectrometer
Comments: 22 pages, 10 figures
Submitted: 2010-10-09
The Far-Infrared Surveyor (FIS) onboard the AKARI satellite has a spectroscopic capability provided by a Fourier transform spectrometer (FIS-FTS). FIS-FTS is the first space-borne imaging FTS dedicated to far-infrared astronomical observations. We describe the calibration process of the FIS-FTS and discuss its accuracy and reliability. The calibration is based on the observational data of bright astronomical sources as well as two instrumental sources. We have compared the FIS-FTS spectra with the spectra obtained from the Long Wavelength Spectrometer (LWS) of the Infrared Space Observatory (ISO) having a similar spectral coverage. The present calibration method accurately reproduces the spectra of several solar system objects having a reliable spectral model. Under this condition the relative uncertainty of the calibration of the continuum is estimated to be $\pm$ 15% for SW, $\pm$ 10% for 70-85 cm^(-1) of LW, and $\pm$ 20% for 60-70 cm^(-1) of LW; and the absolute uncertainty is estimated to be +35/-55% for SW, +35/-55% for 70-85 cm^(-1) of LW, and +40/-60% for 60-70 cm^(-1) of LW. These values are confirmed by comparison with theoretical models and previous observations by the ISO/LWS.
[4]  oai:arXiv.org:1005.2874  [pdf] - 1032509
Herschel-SPIRE spectroscopy of the DR21 molecular cloud core
Comments: 5 pages, 6 figures
Submitted: 2010-05-17
We present far-infrared spectra and maps of the DR21 molecular cloud core between 196 and 671 microns, using the Herschel-SPIRE spectrometer. Nineteen molecular lines originating from CO, 13CO, HCO+ and H2O, plus lines of [N II] and [CI] were recorded, including several transitions not previously detected. The CO lines are excited in warm gas with Tkin ~ 125 K and nH2 ~ 7 x 10^4 cm-3, CO column density N(CO) ~ 3.5 x 10^18 cm^-2 and a filling factor of ~ 12%, and appear to trace gas associated with an outflow. The rotational temperature analysis incorporating observations from ground-based telescopes reveals an additional lower excitation CO compoment which has a temperature ~ 78 K and N(CO) ~ 4.5 x 10^21 cm^-2. Astronomy & Astrophysics HERSCHEL special Issue, in press.