Normalized to: Golovkin, I.
[1]
oai:arXiv.org:1608.03512 [pdf] - 1531248
Comment on "Large enhancement in high-energy photoionization of Fe XVII
and missing continuum plasma opacity"
Blancard, C.;
Colgan, J.;
Cossé, Ph.;
Faussurier, G.;
Fontes, C. J.;
Gilleron, F.;
Golovkin, I.;
Hansen, S. B.;
Iglesias, C. A.;
Kilcrease, D. P.;
MacFarlane, J. J.;
More, R. M.;
Pain, J. -C.;
Sherrill, M.;
Wilson, B. G.
Submitted: 2016-08-10
Recent R-matrix calculations claim to produce a significant enhancement in
the opacity of Fe XVII due to atomic core excitations [S. N. Nahar & A.K.
Pradhan, Phys. Rev. Letters 116, 235003 (2016), arXiv:1606.02731] and assert
that this enhancement is consistent with recent measurements of
higher-than-predicted iron opacities [J. E. Bailey et al., Nature 517, 56
(2015)]. This comment shows that the standard opacity models which have already
been directly compared with experimental data produce photon absorption
cross-sections for Fe XVII that are effectively equivalent to (and in fact
larger than) the new R-matrix opacities. Thus, the new R-matrix results cannot
be expected to significantly impact the existing discrepancies between theory
and experiment because they produce neither a "large enhancement" nor account
for "missing continuum plasma opacity" relative to standard models.
[2]
oai:arXiv.org:1405.4012 [pdf] - 824642
Control and diagnosis of temperature, density, and uniformity in x-ray
heated iron/magnesium samples for opacity measurements
Submitted: 2014-05-15
Experimental tests are in progress to evaluate the accuracy of the modeled
iron opacity at solar interior conditions, in particular to better constrain
the solar abundance problem [S. Basu and H.M. Antia, Physics Reports 457, 217
(2008)]. Here we describe measurements addressing three of the key requirements
for reliable opacity experiments: control of sample conditions, independent
sample condition diagnostics, and verification of sample condition uniformity.
The opacity samples consist of iron/magnesium layers tamped by plastic. By
changing the plastic thicknesses, we have controlled the iron plasma conditions
to reach i) Te=167+/-3 eV and ne=(7.1+/-1.5)e21 e/cc, ii) Te=170+/-2 eV and
ne=(2.0+/-0.2)e22 e/cc, and iii) Te=196+/-6 eV and ne=(3.8+/-0.8)e22 e/cc,
which were measured by magnesium tracer K-shell spectroscopy. The opacity
sample non-uniformity was directly measured by a separate experiment where Al
is mixed into the side of the sample facing the radiation source and Mg into
the other side. The iron condition was confirmed to be uniform within their
measurement uncertainties by Al and Mg K-shell spectroscopy. The conditions are
suitable for testing opacity calculations needed for modeling the solar
interior, other stars, and high energy density plasmas.
[3]
oai:arXiv.org:astro-ph/0703264 [pdf] - 90073
Short-N characteristic radiative transfer method in 2D cylindrical RZ
coordinates
Submitted: 2007-03-12
We present a new radiative transfer method Short-N Characteristics that is a
hybrid between the standard long characteristic methods and the standard short
characteristic methods. We have implemented the numerical method within the
SPECT3D imaging and spectral analysis application. Numerical experiments have
shown that the short-N method is capable of reproducing the accuracy of the
long characteristic methods, while delivering the CPU time efficiency of the
short characteristic methods. We apply the short-N method to 2.5D cylindrical
coordinates, i.e., we assume a 3D problem under azimuthal symmetry leading to a
2D mathematical problem with r-z as the independent spatial coordinates (2DRZ).
We are currently working to extend this new method to other geometries.