Normalized to: Golish, D.
[1]
oai:arXiv.org:1903.11559 [pdf] - 1857306
Spectral clustering tools applied to Ceres in preparation for OSIRIS-REx
color imaging of asteroid (101955) Bennu
Submitted: 2019-03-27
The OSIRIS-REx asteroid sample-return mission is investigating primitive
near-Earth asteroid (101955) Bennu. Thousands of images will be acquired by the
MapCam instrument onboard the spacecraft, an imager with four color filters
based on the Eight-Color Asteroid Survey (ECAS): $b$' (473 nm), $v$ (550 nm),
$w$ (698 nm), and $x$ (847 nm). This set of filters will allow identification
and characterization of the absorption band centered at 700 nm and associated
with hydrated silicates. In this work, we present and validate a spectral
clustering methodology for application to the upcoming MapCam images of the
surface of Bennu. Our procedure starts with the projection, calibration, and
photometric correction of the images. In a second step, we apply a K-means
algorithm and we use the Elbow criterion to identify natural clusters. This
methodology allows us to find distinct areas with spectral similarities, which
are characterized by parameters such as the spectral slope $S$' and the center
and depth of the 700-nm absorption band, if present. We validate this
methodology using images of (1) Ceres from NASA's Dawn mission. In particular,
we analyze the Occator crater and Ahuna Mons. We identify one spectral
cluster--located in the outer parts of the Occator crater interior--showing the
700-nm hydration band centered at 698 $\pm$ 7 nm and with a depth of 3.4 $\pm$
1.0 \%. We interpret this finding in the context of the crater's near-surface
geology.
[2]
oai:arXiv.org:1810.10080 [pdf] - 1773128
Overcoming the Challenges Associated with Image-based Mapping of Small
Bodies in Preparation for the OSIRIS-REx Mission to (101955) Bennu
DellaGiustina, D. N.;
Bennett, C. A.;
Becker, K.;
Golish, D. R;
Corre, L. Le;
Cook, D. A.;
Edmundson, K. L.;
Chojnacki, M.;
Sutton, S. S.;
Milazzo, M. P.;
Carcich, B.;
Nolan, M. C.;
Habib, N.;
Burke, K. N.;
Becker, T.;
Smith, P. H.;
Walsh, K. J.;
Getzandanner, K.;
Wibben, D. R.;
Leonard, J. M.;
Westermann, M. M.;
Polit, A. T.;
Kidd, J. N.;
Hergenrother, C. W.;
Boynton, W. V.;
Backer, J.;
Sides, S.;
Mapel, J.;
Berry, K.;
Roper, H.;
d'Aubigny, C. Drouet;
Rizk, B.;
Crombie, M. K.;
Kinney-Spano, E. K.;
de Leon, J.;
Rizos, J. L.;
Licandro, J.;
Campins, H. C.;
Clark, B. E.;
Enos, H. L.;
Lauretta, D. S.
Submitted: 2018-10-23
The OSIRIS-REx Asteroid Sample Return Mission is the third mission in NASA's
New Frontiers Program and is the first U.S. mission to return samples from an
asteroid to Earth. The most important decision ahead of the OSIRIS-REx team is
the selection of a prime sample-site on the surface of asteroid (101955) Bennu.
Mission success hinges on identifying a site that is safe and has regolith that
can readily be ingested by the spacecraft's sampling mechanism. To inform this
mission-critical decision, the surface of Bennu is mapped using the OSIRIS-REx
Camera Suite and the images are used to develop several foundational data
products. Acquiring the necessary inputs to these data products requires
observational strategies that are defined specifically to overcome the
challenges associated with mapping a small irregular body. We present these
strategies in the context of assessing candidate sample-sites at Bennu
according to a framework of decisions regarding the relative safety,
sampleability, and scientific value across the asteroid's surface. To create
data products that aid these assessments, we describe the best practices
developed by the OSIRIS-REx team for image-based mapping of irregular small
bodies. We emphasize the importance of using 3D shape models and the ability to
work in body-fixed rectangular coordinates when dealing with planetary surfaces
that cannot be uniquely addressed by body-fixed latitude and longitude.
[3]
oai:arXiv.org:1704.04531 [pdf] - 1622198
OCAMS: The OSIRIS-REx Camera Suite
Rizk, B.;
d'Aubigny, C. Drouet;
Golish, D.;
Fellows, C.;
Merrill, C.;
Smith, P.;
Walker, M. S.;
Hendershot, J. E.;
Hancock, J.;
Bailey, S. H.;
DellaGiustina, D.;
Lauretta, D.;
Tanner, R.;
Williams, M.;
Harshman, K.;
Fitzgibbon, M.;
Verts, W.;
Chen, J.;
Connors, T.;
Hamara, D.;
Dowd, A.;
Lowman, A.;
Dubin, M.;
Burt, R.;
Whiteley, M.;
Watson, M.;
McMahon, T.;
Ward, M.;
Booher, D.;
Read, M.;
Williams, B.;
Hunten, M.;
Little, E.;
Saltzman, T.;
Alfred, D.;
Dougherty, S. O;
Walthall, M.;
Kenagy, K.;
Peterson, S.;
Crowther, B.;
Perry, M. L.;
See, C.;
Selznick, S.;
Sauve, C.;
Beiser, M.;
Black, W.;
Pfisterer, R. N.;
Lancaster, A.;
Oliver, S.;
Oquest, C.;
Crowley, D.;
Morgan, C.;
Castle, C.;
Dominguez, R.;
Sullivan, M.
Submitted: 2017-04-14
The requirements-driven OSIRIS-REx Camera Suite (OCAMS) acquires images
essential to collecting a sample from the surface of Bennu. During proximity
operations, these images document the presence of satellites and plumes, record
spin state, enable an accurate digital terrain model of the shape of the
asteroid and identify any surface hazards. They confirm the presence of
sampleable regolith on the surface, observe the sampling event itself, and
image the sample head in order to verify its readiness to be stowed. They
document the history of Bennu as an example of early solar system material, as
a microgravity body with a planetesimal size-scale, and as a carbonaceous
object. OCAMS is fitted with three cameras. The MapCam records point-source
color images on approach to the asteroid in order to connect ground-based
point-source observations of Bennu to later higher-resolution surface spectral
imaging. The SamCam documents the sample site before, during, and after it is
disturbed by the sample mechanism. The PolyCam, using its focus mechanism,
observes the sample site at sub-centimeter resolutions, revealing surface
texture and morphology. While their imaging requirements divide naturally
between the three cameras, they preserve a strong degree of functional overlap.
OCAMS and the other spacecraft instruments allow the OSIRIS-REx mission to
collect a sample from a microgravity body on the same visit during which it was
first optically acquired from long range, a useful capability as humanity
explores near-Earth, Main-Belt and Jupiter Trojan asteroids.
[4]
oai:arXiv.org:0803.3759 [pdf] - 11227
The Hertz/VPM polarimeter: Design and first light observations
Krejny, Megan;
Chuss, David;
d'Aubigny, Christian Drouet;
Golish, Dathon;
Houde, Martin;
Hui, Howard;
Kulesa, Craig;
Loewenstein, Robert F.;
Moseley, S. Harvey;
Novak, Giles;
Voellmer, George;
Walker, Chris;
Wollack, Ed
Submitted: 2008-03-26
We present first results of Hertz/VPM, the first submillimeter polarimeter
employing the dual Variable-delay Polarization Modulator (dual-VPM). This
device differs from previously used polarization modulators in that it operates
in translation rather than mechanical rotation. We discuss the basic theory
behind this device, and its potential advantages over the commonly used half
wave plate (HWP). The dual-VPM was tested both at the Submillimeter Telescope
Observatory (SMTO) and in the lab. In each case we present a detailed
description of the setup. We discovered nonideal behavior in the system. This
is at least in part due to properties of the VPM wire grids (diameter, spacing)
employed in our experiment. Despite this, we found that the dual-VPM system is
robust, operating with high efficiency and low instrumental polarization. This
device is well suited for air and space-borne applications.
[5]
oai:arXiv.org:astro-ph/0606061 [pdf] - 82501
SuperCam, a 64-pixel heterodyne imaging array for the 870 micron
atmospheric window
Groppi, Christopher;
Walker, Christopher;
Kulesa, Craig;
Puetz, Patrick;
Golish, Dathon;
Gensheimer, Paul;
Hedden, Abigail;
Bussmann, Shane;
Weinreb, Sander;
Kuiper, Thomas;
Kooi, Jacob;
Jones, Glenn;
Bardin, Joseph;
Mani, Hamdi;
Lichtenberger, Arthur;
Narayanan, Gopal
Submitted: 2006-06-02
We report on the development of SuperCam, a 64 pixel, superheterodyne camera
designed for operation in the astrophysically important 870 micron atmospheric
window. SuperCam will be used to answer fundamental questions about the physics
and chemistry of molecular clouds in the Galaxy and their direct relation to
star and planet formation. The advent of such a system will provide an order of
magnitude increase in mapping speed over what is now available and
revolutionize how observational astronomy is performed in this important
wavelength regime. Unlike the situation with bolometric detectors, heterodyne
receiver systems are coherent, retaining information about both the amplitude
and phase of the incident photon stream. From this information a high
resolution spectrum of the incident light can be obtained without multiplexing.
SuperCam will be constructed by stacking eight, 1x8 rows of fixed tuned, SIS
mixers. The IF output of each mixer will be connected to a low-noise, broadband
MMIC amplifier integrated into the mixer block. The instantaneous IF bandwidth
of each pixel will be ~2 GHz, with a center frequency of 5 GHz. A spectrum of
the central 500 MHz of each IF band will be provided by the array spectrometer.
Local oscillator power is provided by a frequency multiplier whose output is
divided between the pixels by using a matrix of waveguide power dividers. The
mixer array will be cooled to 4K by a closed-cycle refrigeration system.
SuperCam will reside at the Cassegrain focus of the 10m Heinrich Hertz
telescope (HHT). A prototype single row of the array will be tested on the HHT
in 2006, with the first engineering run of the full array in late 2007. The
array is designed and constructed so that it may be readily scaled to higher
frequencies.