Normalized to: Goldfinger, D.
[1]
oai:arXiv.org:1908.09010 [pdf] - 2040682
Micro-X Sounding Rocket: Transitioning from First Flight to a Dark
Matter Configuration
Adams, J. S.;
Anderson, A. J.;
Baker, R.;
Bandler, S. R.;
Bastidon, N.;
Castro, D.;
Danowski, M. E.;
Doriese, W. B.;
Eckart, M. E.;
Figueroa-Feliciano, E.;
Goldfinger, D. C.;
Heine, S. N. T.;
Hilton, G. C.;
Hubbard, A. J. F.;
Kelley, R. L.;
Kilbourne, C. A.;
Manzagol-Harwood, R. E.;
McCammon, D.;
Okajima, T.;
Porter, F. S.;
Reintsema, C. D.;
Serlemitsos, P.;
Smith, S. J.;
Wikus, P.
Submitted: 2019-08-22, last modified: 2020-01-30
The Micro-X sounding rocket flew for the first time on July 22, 2018,
becoming the first program to fly Transition-Edge Sensors and multiplexing
SQUID readout electronics in space. While a rocket pointing failure led to no
time on-target, the success of the flight systems was demonstrated. The
successful flight operation of the instrument puts the program in a position to
modify the payload for indirect galactic dark matter searches. The payload
modifications are motivated by the science requirements of this observation.
Micro-X can achieve world-leading sensitivity in the keV regime with a single
flight. Dark matter sensitivity projections have been updated to include recent
observations and the expected sensitivity of Micro-X to these observed fluxes.
If a signal is seen (as seen in the X-ray satellites), Micro-X can
differentiate an atomic line from a dark matter signature.
[2]
oai:arXiv.org:1908.09689 [pdf] - 2022786
First Operation of TES Microcalorimeters in Space with the Micro-X
Sounding Rocket
Adams, J. S.;
Baker, R.;
Bandler, S. R.;
Bastidon, N.;
Danowski, M. E.;
Doriese, W. B.;
Eckart, M. E.;
Figueroa-Feliciano, E.;
Goldfinger, D. C.;
Heine, S. N. T.;
Hilton, G. C.;
Hubbard, A. J. F.;
Kelley, R. L.;
Kilbourne, C. A.;
Manzagol-Harwood, R. E.;
McCammon, D.;
Okajima, T.;
Porter, F. S.;
Reintsema, C. D.;
Serlemitsos, P.;
Smith, S. J.;
Ullom, J. N.;
Wikus, P.
Submitted: 2019-08-26, last modified: 2020-01-05
Micro-X is a sounding rocket-borne instrument that uses a microcalorimeter
array to perform high-resolution X-ray spectroscopy. This instrument flew for
the first time on July 22nd, 2018 from the White Sands Missile Range, USA. This
flight marks the first successful operation of a Transition-Edge Sensor array
and its time division multiplexing read-out system in space. This launch was
dedicated to the observation of the supernova remnant Cassiopeia A. A failure
in the attitude control system prevented the rocket from pointing and led to no
time on target. The on-board calibration source provided X-rays in flight, and
it is used to compare detector performance during pre-flight integration,
flight, and after the successful post-flight recovery. This calibration data
demonstrates the capabilities of the detector in a space environment as well as
its potential for future flights.
[3]
oai:arXiv.org:1506.05519 [pdf] - 1212420
Searching for keV Sterile Neutrino Dark Matter with X-ray
Microcalorimeter Sounding Rockets
Figueroa-Feliciano, Enectali;
Anderson, Adam J.;
Castro, Daniel;
Goldfinger, David C.;
Rutherford, John;
Eckart, Megan E.;
Kelley, Richard L.;
Kilbourne, Caroline A.;
McCammon, Dan;
Morgan, Kelsey;
Porter, Frederick Scott;
Szymkowiak, Andrew E.
Submitted: 2015-06-17
High-resolution X-ray spectrometers onboard suborbital sounding rockets can
search for dark matter candidates that produce X-ray lines, such as decaying
keV-scale sterile neutrinos. Even with exposure times and effective areas far
smaller than XMM-Newton and Chandra observations, high-resolution, wide
field-of-view observations with sounding rockets have competitive sensitivity
to decaying sterile neutrinos. We analyze a subset of the 2011 observation by
the X-ray Quantum Calorimeter instrument centered on Galactic coordinates l =
165, b = -5 with an effective exposure of 106 seconds, obtaining a limit on the
sterile neutrino mixing angle of sin^2(2 theta) < 7.2e-10 at 95% CL for a 7 keV
neutrino. Better sensitivity at the level of sin^2(2 theta) ~ 2.1e-11 at 95\%
CL for a 7 keV neutrino is achievable with future 300-second observations of
the galactic center by the Micro-X instrument, providing a definitive test of
the sterile neutrino interpretation of the reported 3.56 keV excess from galaxy
clusters.