Glück, M.

Normalized to: Glück, M.

7 article(s) in total. 139 co-authors, from 1 to 6 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:1912.09537  [pdf] - 2018298
Focal Plane Tip-Tilt Sensing for Improved Single-Mode Fiber Coupling using a 3D-printed Microlens-Ring
Comments: AO4ELT6 Conference Proceedings, 7 pages, 4 figures
Submitted: 2019-12-19
Modern extreme adaptive optics (AO) systems achieving diffraction-limited performance open up new possibilities for instrumentation. Especially important for the fields of spectroscopy and interferometry is that it enables the prospect to couple light into single-mode fibers (SMFs). However, due to their small size, efficient coupling is very sensitive to the quality of the fiber alignment, beam drifts and higher-frequency tip-tilt aberrations caused by telescope mechanics and vibrations. These residual aberrations are not always sensed and corrected by the AO system, leading to unacceptable losses. This is particularly severe for the Extremely Large Telescopes, where their huge structure will mean vibrations increase and optimal AO solutions are even more difficult to implement. We have created a focal plane sensor to correct for residual aberrations by surrounding the SMF with six Multi-mode fibers (MMFs). On each of the MMFs sits a printed freeform lens, making up a six-element micro-lens ring to refract the light into these surrounding MMFs and thus minimizing light loss in the gap between the fiber cores. This means when the beam is near diffraction limited and centered almost all light couples to the SMF. When the beam is misaligned, it couples to the surrounding cores, which are read out by a detector and processed by the DARC software driving a tip-tilt mirror. Currently we are aiming to detect and correct only tip-tilt aberrations. However, choosing to surround the central fiber with six sensing locations potentially allows us to investigate higher order correction modes. Here we present the design and performance our prototype system. This has been designed for use with the iLocater fiber injection system at the LBT and can easily be scaled to larger telescopes. We present test results from the KOOL laboratory and initial integration with the iLocater instrument.
[2]  oai:arXiv.org:1902.00738  [pdf] - 1875316
Development of the Warm Astrometric Mask for MICADO astrometry calibration
Comments:
Submitted: 2019-02-02
The achievement of $\mu$arcsec relative astrometry with ground-based, near infrared, extremely large telescopes requires a significant endeavour of calibration strategies. In this paper we address the removal of instrument optical distortions coming from the ELT first light instrument MICADO and its adaptive optics system MAORY by means of an astrometric calibration mask. The results of the test campaign on a prototype mask (scale 1:2) has probed the manufacturing precision down to $\sim$ 50nm/1mm scale, leading to a relative precision $\delta\sigma \sim 5e-5$. The assessed manufacturing precision indicates that an astrometric relative precision of $\delta\sigma \sim 5e-5 = \frac{50\mu as}{1 arcsec}$ is in principle achievable, disclosing $\mu$arcsec near infrared astrometry behind an extremely large telescope. The impact of $\sim$ 10-100 nm error residuals on the mask pinholes position is tolerable at a calibration level as confirmed by ray tracing simulations of realistic MICADO distortion patterns affected by mid spatial frequencies residuals. We demonstrated that the MICADO astrometric precision of 50 $\mu$as is achievable also in presence of a mid spatial frequencies pattern and manufacturing errors of the WAM by fitting the distorted WAM pattern seen through the instrument with a 10$^{th}$ order Legendre polynomial.
[3]  oai:arXiv.org:1808.03190  [pdf] - 1730722
Micro-lens array as tip-tilt sensor for single-mode fiber coupling
Comments: 15 pages, 11 figures, SPIE Astronomical Telescopes + Instrumentation
Submitted: 2018-08-09
We introduce a design for a tip-tilt sensor with integrated single-mode fiber coupling for use with the front-end prototype of the iLocater spectrograph at the Large Binocular Telescope to detect vibrations that occur within the optical train. This sensor is made up of a micro-lens array printed on top of a fiber bundle consisting of a central single-mode fiber and six surrounding multi-mode fibers. The design in based on a previous prototype that utilized a multi-core fiber with seven single-mode fibers. With this updated design, we are able to achieve a better sensing throughput. We report on the modeled performance: if the beam is perfectly aligned, 69% light is coupled into the central single-mode fiber feeding the scientific instrument. When the beam is not aligned, some of the light will be coupled into the outer sensing fibers, providing the position of the beam for tip-tilt correction. For this design we show that there is a linear response in the sensing fibers when the beam is subject to tip-tilt movement. Furthermore we introduce an adaptive optics testbed, which we call the Koenigstuhl Observatory Opto-mechatronics Laboratory (KOOL), this testbed currently simulates vibrations at the Large Binocular Telescope, and in collaboration we have extended it to allow single-mode fiber coupling tests.
[4]  oai:arXiv.org:1807.10003  [pdf] - 1723038
The MICADO first light imager for the ELT: overview, operation, simulation
Davies, Richard; Alves, João; Clénet, Yann; Lang-Bardl, Florian; Nicklas, Harald; Pott, Jörg-Uwe; Ragazzoni, Roberto; Tolstoy, Eline; Amico, Paola; Anwand-Heerwart, Heiko; Barboza, Santiago; Barl, Lothar; Baudoz, Pierre; Bender, Ralf; Bezawada, Naidu; Bizenberger, Peter; Boland, Wilfried; Bonifacio, Piercarlo; Borgo, Bruno; Buey, Tristan; Chapron, Frédéric; Chemla, Fanny; Cohen, Mathieu; Czoske, Oliver; Deo, Vincent; Disseau, Karen; Dreizler, Stefan; Dupuis, Olivier; Fabricius, Maximilian; Falomo, Renato; Fedou, Pierre; Schreiber, Natascha Foerster; Garrel, Vincent; Geis, Norbert; Gemperlein, Hans; Gendron, Eric; Genzel, Reinhard; Gillessen, Stefan; Glück, Martin; Grupp, Frank; Hartl, Michael; Häuser, Marco; Hess, Hans-Joachim; Hofferbert, Ralf; Hopp, Ulrich; Hörmann, Veronika; Hubert, Zoltan; Huby, Elsa; Huet, Jean-Michel; Hutterer, Victoria; Ives, Derek; Janssen, Annemieke; Jellema, Willem; Kausch, Wolfgang; Kerber, Florian; Kravcar, Helmut; Ruyet, Bertrand Le; Leschinski, Kieran; Mandla, Christopher; Manhart, Markus; Massari, Davide; Mei, Simona; Merlin, Frédéric; Mohr, Lars; Monna, Anna; Muench, Norbert; Mueller, Friedrich; Musters, Gert; Navarro, Ramon; Neumann, Udo; Neumayer, Nadine; Niebsch, Jenny; Plattner, Markus; Przybilla, Norbert; Rabien, Sebastian; Ramlau, Ronny; Ramos, José; Ramsay, Suzanne; Rhode, Petra; Richter, Amon; Richter, Josef; Rix, Hans-Walter; Rodeghiero, Gabriele; Rohloff, Ralf-Rainer; Rosensteiner, Matthias; Rousset, Gérard; Schlichter, Jörg; Schubert, Josef; Sevin, Arnaud; Stuik, Remko; Sturm, Eckhard; Thomas, Jens; Tromp, Niels; Kleijn, Gijs Verdoes; Vidal, Fabrice; Wagner, Roland; Wegner, Michael; Zeilinger, Werner; Ziegleder, Julian; Ziegler, Bodo; Zins, Gérard
Comments: Proc SPIE 10702. SPIE's copyright notice: "Copyright 2018 Society of PhotoOptical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited."
Submitted: 2018-07-26
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and making use of the data simulation tool, an outline is presented of what we can expect the instrument to achieve.
[5]  oai:arXiv.org:1806.01327  [pdf] - 1694234
The impact of ELT distortions and instabilities on future astrometric observations
Comments:
Submitted: 2018-06-04
The paper discusses an assessment study about the impact of the distortions on the astrometric observations with the Extremely Large Telescope originated from the optics positioning errors and telescope instabilities. Optical simulations combined with Monte Carlo approach reproducing typical inferred opto-mechanical and dynamical instabilities, show RMS distortions between $\sim$ 0.1-5 mas over 1 arcmin field of view. Over minutes timescales the plate scale variations from ELT-M2 caused by wind disturbances and gravity flexures and the field rotation from ELT-M4-M5 induce distortions and PSF jitter at the edge of 1 arcmin FoV (radius 35 arcsec) up to $\sim$ 5 mas comparable to the diffraction-limited PSF size $FWHM_H = 8.5$ mas. The RMS distortions inherent to the ELT design are confined to the 1$^{st}$-3$^{rd}$ order and reduce to an astrometric RMS residual post fit of $\sim$ 10-20 $\mu as$ for higher order terms. In this paper, we study which calibration effort has to be undertaken to reach an astrometric stability close to this level of higher order residuals. The amplitude and timescales of the assumed telescope tolerances indicate the need for frequent on-sky calibrations and MCAO stabilization of the plate scale to enable astrometric observations with ELT at the level of $\leq 50 \mu as$, which is one of the core science missions for the ELT / MICADO instrument.
[6]  oai:arXiv.org:1607.01954  [pdf] - 1530973
MICADO: first light imager for the E-ELT
Comments: to appear in Ground-based and Airborne Instrumentation for Astronomy VI, eds. Evans C., Simard L., Takami H., Proc. SPIE vol. 9908 id 73; 2016
Submitted: 2016-07-07
MICADO will equip the E-ELT with a first light capability for diffraction limited imaging at near-infrared wavelengths. The instrument's observing modes focus on various flavours of imaging, including astrometric, high contrast, and time resolved. There is also a single object spectroscopic mode optimised for wavelength coverage at moderately high resolution. This contribution provides an overview of the key functionality of the instrument, outlining the scientific rationale for its observing modes. The interface between MICADO and the adaptive optics system MAORY that feeds it is summarised. The design of the instrument is discussed, focussing on the optics and mechanisms inside the cryostat, together with a brief overview of the other key sub-systems.
[7]  oai:arXiv.org:astro-ph/0503442  [pdf] - 71824
Alternative Multipole Vectors for the CMB Temperature Fluctuations
Comments: 4 pages, no figures, minor misprints corrected
Submitted: 2005-03-21, last modified: 2005-03-22
We introduce new, low-$\ell$, multipole vectors for the CMB temperature fluctuations. A very strong alignment of the quadrupole and octopole vectors is observed as well as a remarkably low declination of these vectors with respect to the galactic plane.