Normalized to: Gironnet, J.
[1]
oai:arXiv.org:1909.11450 [pdf] - 1968540
Assessment of the GCT prototype's optical system implementation and
other key performances for the Cherenkov Telescope Array
Dmytriiev, A.;
Dangeon, L.;
Fasola, G.;
Sol, H.;
Zech, A.;
Gironnet, J.;
Blanc, O. Le;
Amans, J. P.;
Buchholtz, G.;
Dournaux, J. L.;
de Frondat, F.;
Horville, D.;
Huet, J. M.;
Jégouzo, I.;
Laporte, P.
Submitted: 2019-09-25
The Cherenkov Telescope Array (CTA) project, led by an international
collaboration of institutes, aims to create the world's largest next generation
observatory for Very High Energy (VHE) gamma-ray astronomy. It will be devoted
to observations in a wide band of energy, from a few tens of GeV to a few
hundreds of TeV with Large, Medium and Small-sized telescopes. The Small-Size
Telescopes (SSTs) are dedicated to the highest energy range above a few TeV and
up to 300 TeV. GCT is an imaging atmospheric Cherenkov telescope (IACT)
proposed for the subarray of about 70 SSTs to be installed on the Southern site
of CTA in Chile. The Observatory of Paris and the National Institute for Earth
Sciences and Astronomy (INSU/CNRS) have developed the mechanical structure,
mirrors (aspherical lightweight aluminium segments) and control system of the
GCT. The GCT is based on a Schwarzschild- Couder (S-C) dual-mirror optical
design which has the advantages, compared to the current IACTs, to offer a wide
field of view (~ 9{\deg}) while decreasing the cost and volume (~ 9 m x 4 m x 6
m for ~ 11 tons) of the telescope structure, as well as the camera. The
prototype (pGCT) has been installed at the Meudon's site of the Observatory of
Paris and was the first S-C telescope and the first CTA prototype to record VHE
events on-sky in November 2015. After three years of intensive testing, pGCT
has now been commissioned. This paper is a status report on the complete GCT
telescope optical system and the performance it can provide for CTA.
[3]
oai:arXiv.org:1806.11308 [pdf] - 1716177
Characterisation and Testing of CHEC-M - a camera prototype for the
Small-Sized Telescopes of the Cherenkov Telescope Array
Zorn, J.;
White, R.;
Watson, J. J.;
Armstrong, T. P.;
Balzer, A.;
Barcelo, M.;
Berge, D.;
Bose, R.;
Brown, A. M.;
Bryan, M.;
Chadwick, P. M.;
Clark, P.;
Costantini, H.;
Cotter, G.;
Dangeon, L.;
Daniel, M.;
De Franco, A.;
Deiml, P.;
Fasola, G.;
Funk, S.;
Gebyehu, M.;
Gironnet, J.;
Graham, J. A.;
Greenshaw, T.;
Hinton, J. A.;
Kraus, M.;
Lapington, J. S.;
Laporte, P.;
Leach, S. A.;
Blanc, O. Le;
Malouf, A.;
Molyneux, P.;
Moore, P.;
Prokoph, H.;
Okumura, A.;
Ross, D.;
Rowell, G.;
Sapozhnikov, L.;
Schoorlemmer, H.;
Sol, H.;
Stephan, M.;
Tajima, H.;
Tibaldo, L.;
Varner, G.;
Zink, A.
Submitted: 2018-06-29, last modified: 2018-07-16
The Compact High Energy Camera (CHEC) is a camera design for the Small-Sized
Telescopes (SSTs; 4 m diameter mirror) of the Cherenkov Telescope Array (CTA).
The SSTs are focused on very-high-energy $\gamma$-ray detection via atmospheric
Cherenkov light detection over a very large area. This implies many individual
units and hence cost-effective implementation. CHEC relies on dual-mirror
optics to reduce the plate-scale and make use of 6 $\times$ 6 mm$^2$ pixels,
leading to a low-cost ($\sim$150 kEuro), compact (0.5 m $\times$ 0.5 m), and
light ($\sim$45 kg) camera with 2048 pixels providing a camera FoV of $\sim$9
degrees. The electronics are based on custom TARGET (TeV array readout with
GSa/s sampling and event trigger) ASICs and FPGAs sampling incoming signals at
a gigasample per second, with flexible camera-level triggering within a single
backplane FPGA. CHEC is designed to observe in the $\gamma$-ray energy range of
1$-$300 TeV, and at impact distances up to $\sim$500 m. To accommodate this and
provide full flexibility for later data analysis, full waveforms with 96
samples for all 2048 pixels can be read out at rates up to $\sim$900 Hz. The
first prototype, CHEC-M, based on multi-anode photomultipliers (MAPMs) as
photosensors, was commissioned and characterised in the laboratory and during
two measurement campaigns on a telescope structure at the Paris Observatory in
Meudon. In this paper, the results and conclusions from the laboratory and
on-site testing of CHEC-M are presented. They have provided essential input on
the system design and on operational and data analysis procedures for a camera
of this type. A second full-camera prototype based on Silicon photomultipliers
(SiPMs), addressing the drawbacks of CHEC-M identified during the first
prototype phase, has already been built and is currently being commissioned and
tested in the laboratory.
[5]
oai:arXiv.org:1709.03954 [pdf] - 1620688
Towards final characterisation and performance of the GCT prototype
telescope structure for the Cherenkov Telescope Array
Blanc, Oriane Le;
Fasola, Gilles;
Dournaux, Jean-Laurent;
Dangeon, Lucie;
Hocdé, Vincent;
Amans, Jean-Philippe;
Huet, Jean-Michel;
Jégouzo, Isabelle;
Laporte, Philippe;
Sol, Hélène;
De Frondat, Fatima;
Perennes, Cédric;
Gironnet, Johann;
Buchholtz, Gilles;
Abchiche, Abdel
Submitted: 2017-09-12
The Gamma-ray Cherenkov Telescope (GCT) is an innovative dual-mirror solution
proposed for the Small Size Telescopes of the future Cherenkov Telescope Array
(CTA), capable of imaging the showers induced by cosmic gamma-rays with
energies from a few TeV up to 300 TeV. The Schwarzschild Couder design on which
the telescope optical design is based makes possible the construction of a fast
telescope (primary mirror diameter 4 m, focal length 2.3 m) with a plate scale
well matched to compact photosensors, such as multi anode or silicon
photomultipliers (MAPMs and SiPMs, respectively) for the camera. The prototype
GCT on Meudon's site of the Observatoire de Paris saw first Cherenkov light
from air showers in November 2015, using an MAPM based camera. In this
contribution, we firstly report on the prototype GCT telescope's performance
during its assessment phase. Secondly, we present the telescope configuration
during a campaign of observations held in spring 2017. Finally, we describe
studies of the telescope structure, such as the pointing and tracking
performance.
[7]
oai:arXiv.org:1610.01398 [pdf] - 1580334
The Gamma-ray Cherenkov Telescope for the Cherenkov Telescope Array
Tibaldo, L.;
Abchiche, A.;
Allan, D.;
Amans, J. -P.;
Armstrong, T. P.;
Balzer, A.;
Berge, D.;
Boisson, C.;
Bousquet, J. -J.;
Brown, A. M.;
Bryan, M.;
Buchholtz, G.;
Chadwick, P. M.;
Costantini, H.;
Cotter, G.;
Daniel, M. K.;
De Franco, A.;
De Frondat, F.;
Dournaux, J. -L.;
Dumas, D.;
Ernenwein, J. -P.;
Fasola, G.;
Funk, S.;
Gironnet, J.;
Graham, J. A.;
Greenshaw, T.;
Hervet, O.;
Hidaka, N.;
Hinton, J. A.;
Huet, J. -M.;
Jankowsky, D.;
Jegouzo, I.;
Jogler, T.;
Kraus, M.;
Lapington, J. S.;
Laporte, P.;
Lefaucheur, J.;
Markoff, S.;
Melse, T.;
Mohrmann, L.;
Molyneux, P.;
Nolan, S. J.;
Okumura, A.;
Osborne, J. P.;
Parsons, R. D.;
Rosen, S.;
Ross, D.;
Rowell, G.;
Rulten, C. B.;
Sato, Y.;
Sayede, F.;
Schmoll, J.;
Schoorlemmer, H.;
Servillat, M.;
Sol, H.;
Stamatescu, V.;
Stephan, M.;
Stuik, R.;
Sykes, J.;
Tajima, H.;
Thornhill, J.;
Trichard, C.;
Vink, J.;
Watson, J. J.;
White, R.;
Yamane, N.;
Zech, A.;
Zink, A.;
Zorn, J.;
Consortium, the CTA
Submitted: 2016-10-05
The Cherenkov Telescope Array (CTA) is a forthcoming ground-based observatory
for very-high-energy gamma rays. CTA will consist of two arrays of imaging
atmospheric Cherenkov telescopes in the Northern and Southern hemispheres, and
will combine telescopes of different types to achieve unprecedented performance
and energy coverage. The Gamma-ray Cherenkov Telescope (GCT) is one of the
small-sized telescopes proposed for CTA to explore the energy range from a few
TeV to hundreds of TeV with a field of view $\gtrsim 8^\circ$ and angular
resolution of a few arcminutes. The GCT design features dual-mirror
Schwarzschild-Couder optics and a compact camera based on densely-pixelated
photodetectors as well as custom electronics. In this contribution we provide
an overview of the GCT project with focus on prototype development and testing
that is currently ongoing. We present results obtained during the first
on-telescope campaign in late 2015 at the Observatoire de Paris-Meudon, during
which we recorded the first Cherenkov images from atmospheric showers with the
GCT multi-anode photomultiplier camera prototype. We also discuss the
development of a second GCT camera prototype with silicon photomultipliers as
photosensors, and plans toward a contribution to the realisation of CTA.
[8]
oai:arXiv.org:1610.01452 [pdf] - 1580337
Inauguration and First Light of the GCT-M Prototype for the Cherenkov
Telescope Array
Watson, J. J.;
De Franco, A.;
Abchiche, A.;
Allan, D.;
Amans, J. -P.;
Armstrong, T. P.;
Balzer, A.;
Berge, D.;
Boisson, C.;
Bousquet, J. -J.;
Brown, A. M.;
Bryan, M.;
Buchholtz, G.;
Chadwick, P. M.;
Costantini, H.;
Cotter, G.;
Daniel, M. K.;
De Frondat, F.;
Dournaux, J. -L.;
Dumas, D.;
Ernenwein, J. -P.;
Fasola, G.;
Funk, S.;
Gironnet, J.;
Graham, J. A.;
Greenshaw, T.;
Hervet, O.;
Hidaka, N.;
Hinton, J. A.;
Huet, J. -M.;
Jegouzo, I.;
Jogler, T.;
Kraus, M.;
Lapington, J. S.;
Laporte, P.;
Lefaucheur, J.;
Markoff, S.;
Melse, T.;
Mohrmann, L.;
Molyneux, P.;
Nolan, S. J.;
Okumura, A.;
Osborne, J. P.;
Parsons, R. D.;
Rosen, S.;
Ross, D.;
Rowell, G.;
Rulten, C. B.;
Sato, Y.;
Sayéde, F.;
Schmoll, J.;
Schoorlemmer, H.;
Servillat, M.;
Sol, H.;
Stamatescu, V.;
Stephan, M.;
Stuik, R.;
Sykes, J.;
Tajima, H.;
Thornhill, J.;
Tibaldo, L.;
Trichard, C.;
Vink, J.;
White, R.;
Yamane, N.;
Zech, A.;
Zink, A.;
Zorn, J.;
Consortium, the CTA
Submitted: 2016-10-05
The Gamma-ray Cherenkov Telescope (GCT) is a candidate for the Small Size
Telescopes (SSTs) of the Cherenkov Telescope Array (CTA). Its purpose is to
extend the sensitivity of CTA to gamma-ray energies reaching 300 TeV. Its
dual-mirror optical design and curved focal plane enables the use of a compact
camera of 0.4 m diameter, while achieving a field of view of above 8 degrees.
Through the use of the digitising TARGET ASICs, the Cherenkov flash is sampled
once per nanosecond continuously and then digitised when triggering conditions
are met within the analogue outputs of the photosensors. Entire waveforms
(typically covering 96 ns) for all 2048 pixels are then stored for analysis,
allowing for a broad spectrum of investigations to be performed on the data.
Two prototypes of the GCT camera are under development, with differing
photosensors: Multi-Anode Photomultipliers (MAPMs) and Silicon Photomultipliers
(SiPMs). During November 2015, the GCT MAPM (GCT-M) prototype camera was
integrated onto the GCT structure at the Observatoire de Paris-Meudon, where it
observed the first Cherenkov light detected by a prototype instrument for CTA.
[9]
oai:arXiv.org:1608.03420 [pdf] - 1521294
The GCT camera for the Cherenkov Telescope Array
Brown, Anthony M.;
Abchiche, A.;
Allan, D.;
Amans, J. P.;
Armstrong, T. P.;
Balzer, A.;
Berge, D.;
Boisson, C.;
Bousquet, J. -J.;
Bryan, M.;
Buchholtz, G.;
Chadwick, P. M.;
Costantini, H.;
Cotter, G.;
Daniel, M. K.;
De Franco, A.;
De Frondat, F.;
Dournaux, J. -L.;
Dumas, D.;
Fasola, G.;
Funk, S.;
Gironnet, J.;
Graham, J. A.;
Greenshaw, T.;
Hervet, O.;
Hidaka, N.;
Hinton, J. A.;
Huet, J. -M.;
Jegouzo, I.;
Jogler, T.;
Kraus, M.;
Lapington, J. S.;
Laporte, P.;
Lefaucheur, J.;
Markoff, S.;
Melse, T.;
Mohrmann, L.;
Molyneux, P.;
Nolan, S. J.;
Okumura, A.;
Osborne, J. P.;
Parsons, R. D.;
Rosen, S.;
Ross, D.;
Rowell, G.;
Sato, Y.;
Sayede, F.;
Schmoll, J.;
Schoorlemmer, H.;
Servillat, M.;
Sol, H.;
Stamatescu, V.;
Stephan, M.;
Stuik, R.;
Sykes, J.;
Tajima, H.;
Thornhill, J.;
Tibaldo, L.;
Trichard, C.;
Vink, J.;
Watson, J. J.;
White, R.;
Yamane, N.;
Zech, A.;
Zink, A.;
Zorn, J.
Submitted: 2016-08-11
The Gamma-ray Cherenkov Telescope (GCT) is proposed for the Small-Sized
Telescope component of the Cherenkov Telescope Array (CTA). GCT's dual-mirror
Schwarzschild-Couder (SC) optical system allows the use of a compact camera
with small form-factor photosensors. The GCT camera is ~0.4 m in diameter and
has 2048 pixels; each pixel has a ~0.2 degree angular size, resulting in a wide
field-of-view. The design of the GCT camera is high performance at low cost,
with the camera housing 32 front-end electronics modules providing full
waveform information for all of the camera's 2048 pixels. The first GCT camera
prototype, CHEC-M, was commissioned during 2015, culminating in the first
Cherenkov images recorded by a SC telescope and the first light of a CTA
prototype. In this contribution we give a detailed description of the GCT
camera and present preliminary results from CHEC-M's commissioning.
[10]
oai:arXiv.org:1207.1815 [pdf] - 568705
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization
detectors
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
Domange, J.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Heuermann, G.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrento-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2012-07-07, last modified: 2012-09-05
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear
recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium
detectors equipped with thermal sensors and an electrode design (ID) which
allows to efficiently reject several sources of background. The data indicate
no evidence for an exponential distribution of low-energy nuclear recoils that
could be attributed to WIMP elastic scattering after an exposure of 113 kg.d.
For WIMPs of mass 10 GeV, the observation of one event in the WIMP search
region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent
WIMP-nucleon scattering cross-section, which constrains the parameter space
associated with the findings reported by the CoGeNT, DAMA and CRESST
experiments.
[11]
oai:arXiv.org:1103.4070 [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of
cryogenic germanium detectors with interleaved electrodes
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chardin, G.;
Chapellier, M.;
Charlieux, F.;
Coulter, P.;
Cox, G. A.;
Defay, X.;
De Jesus, M.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A-S.;
Vagneron, L.;
Verdier, M-A.;
Walker, R. J.;
Yakushev, E.
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark
matter with an array of ten 400-g cryogenic germanium detectors in operation at
the Laboratoire Souterrain de Modane. The combined use of thermal phonon
sensors and charge collection electrodes with an interleaved geometry enables
the efficient rejection of gamma-induced radioactivity as well as near-surface
interactions. A total effective exposure of 384 kg.d has been achieved, mostly
coming from fourteen months of continuous operation. Five nuclear recoil
candidates are observed above 20 keV, while the estimated background is 3.0
events. The result is interpreted in terms of limits on the cross-section of
spin-independent interactions of WIMPs and nucleons. A cross-section of
4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints
are also set on models where the WIMP-nucleon scattering is inelastic.
[12]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.