sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Giomataris, Y.

Normalized to: Giomataris, Y.

6 article(s) in total. 105 co-authors, from 1 to 3 common article(s). Median position in authors list is 2,0.

[1]  oai:arXiv.org:1610.02396  [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Comments: 58 pages, 26 figures, accepted by Physics Reports
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
[2]  oai:arXiv.org:1603.03966  [pdf] - 1376056
Neutral Current Coherent Cross Sections -- Implications on Gaseous Spherical TPC's for detecting SN and Earth neutrinos
Comments: 14 pages with 8 Figures. It will be published in a special volume dedicated to the memory of G. E. Brown. arXiv admin note: substantial text overlap with arXiv:1103.1107
Submitted: 2016-03-12, last modified: 2016-03-16
The detection of galactic supernova (SN) neutrinos represents one of the future frontiers of low-energy neutrino physics and astrophysics. The neutron coherence of neutral currents (NC) allows quite large cross sections in the case of neutron rich targets, which can be exploited in detecting earth and sky neutrinos by measuring nuclear recoils. They are relatively cheap and easy to maintain. The relevant NC cross sections are not dependent on flavor conversions and, thus, their measurement will provide useful information about the neutrino source. In particular they will yield information about the primary neutrino fluxes and perhaps about the spectrum after flavor conversions in neutrino sphere.They might also provide some clues about the neutrino mass hierarchy. The advantages of large gaseous low threshold and high resolution detectors with time projection counters (TPC) are discussed.
[3]  oai:arXiv.org:1109.1675  [pdf] - 1083919
Micromegas detector developments for MIMAC
Comments: 8 pages, 7 figures Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011; corrections on author affiliations
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
[4]  oai:arXiv.org:astro-ph/0511470  [pdf] - 77828
Dedicated Supernova Detection by a Network of Neutral Current Spherical TPC's
Comments: 10 LaTex pages, 11 post script figures. To appear in the proceedings of NANP05, Dubna, Russia
Submitted: 2005-11-16
Supernova neutrinos can easily be detected by a spherical gaseous TPC detector measuring very low energy nuclear recoils. The expected rates are quite large for a neutron rich target since the neutrino nucleus neutral current interaction yields a coherent contribution of all neutrons. As a matter of fact for a typical supernova at 10 kpc, about 1000 events are expected using a spherical detector of radius 4 m with Xe gas at a pressure of 10 Atm. A world wide network of several such simple, stable and low cost supernova detectors with a running time of a few centuries is quite feasible.
[5]  oai:arXiv.org:hep-ex/0503029  [pdf] - 113360
A Network of Neutral Current Spherical TPC's for Dedicated Supernova Detection
Comments: 17 LaTex pages, 9 PostScript figures
Submitted: 2005-03-17, last modified: 2005-06-15
The coherent contribution of all neutrons in neutrino nucleus scattering due to the neutral current offers a realistic prospect of detecting supernova neutrinos. As a matter of fact. for a typical supernova at 10 kpc, about 1000 events are expected usinga spherical gaseous detector of radius 4 m andemploying Xe gas at a pressure of 10 Atm. We propose a world wide network of several such simple, stable and low cost supernova detectors with a running time of a few centuries.
[6]  oai:arXiv.org:hep-ex/0009063  [pdf] - 387150
Low-background applications of MICROMEGAS detector technology
Comments: 5 pg, presented at IMAGING-2000, Stockholm, June 2000. To appear in Nucl. Instr. & Meth. Final version after referees' input
Submitted: 2000-09-28, last modified: 2001-01-17
The MICROMEGAS detector concept, generally optimized for use in accelerator experiments, displays a peculiar combination of features that can be advantageous in several astroparticle and neutrino physics applications. Their sub-keV ionization energy threshold, excellent energy and space resolution, and a simplicity of design that allows the use of radioclean materials in their construction are some of these characteristics. We envision tackling experimental challenges such as the measurement of neutral-current neutrino-nucleus coherent scattering or Weakly Interacting Massive Particle (WIMP) detectors with directional sensitivity. The large physics potential of a compact (total volume O(1)m$^{3}$), multi-purpose array of low-background MICROMEGAS is made evident.