Normalized to: Giomataris, I.
[1]
oai:arXiv.org:1902.08960 [pdf] - 1890376
Precision laser-based measurements of the single electron response of
SPCs for the NEWS-G light dark matter search experiment
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Bard, J. -P.;
Brossard, A.;
Chapellier, M.;
Clark, M.;
Crawford, S.;
Corcoran, E. C.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Giroux, G.;
Gorel, P.;
Gros, M.;
Gros, P.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Knights, P.;
Langrock, S.;
Lautridou, P.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Nikolopoulos, K.;
Piquemal, F.;
Piro, M. -C.;
Santos, D.;
Savvidis, G.;
Savvidis, I.;
Fernandez, F. Vazquez de Sola;
Vidal, M.;
Zampaolo, M.
Submitted: 2019-02-24
Spherical Proportional Counters (SPCs) are a novel gaseous detector
technology employed by the NEWS-G low-mass dark matter search experiment for
their high sensitivity to single electrons from ionization. In this paper, we
report on the first characterization of the single electron response of SPCs
with unprecedented precision, using a UV-laser calibration system. The
experimental approach and analysis methodology are presented along with various
direct applications for the upcoming next phase of the experiment at SNOLAB.
These include the continuous monitoring of the detector response and electron
drift properties during dark matter search runs, as well as the experimental
measurement of the trigger threshold efficiency. We measure a mean ionization
energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$
for 2.8 keV X-rays, and demonstrate the feasibility of performing similar
precision measurements at sub-keV energies for future gas mixtures to be used
for dark matter searches at SNOLAB.
[2]
oai:arXiv.org:1706.04934 [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at
the LSM
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Asner, D.;
Bard, J. -P.;
Brossard, A.;
Cai, B.;
Chapellier, M.;
Clark, M.;
Corcoran, E. C.;
Dandl, T.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Gorel, P.;
Gros, M.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Navick, X. -F.;
Papaevangelou, T.;
Piquemal, F.;
Roth, S.;
Santos, D.;
Savvidis, I.;
Ulrich, A.;
Fernandez, F. Vazquez de Sola;
Zampaolo, M.
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection
experiment using Spherical Proportional Counters (SPCs) with light noble gases
to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report
the results from the first physics run taken at the Laboratoire Souterrain de
Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a
mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total
exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the
spin-independent WIMP-nucleon scattering cross-section in the
sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times
\mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5
$\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are
promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to
be installed at SNOLAB by summer 2018.
[3]
oai:arXiv.org:1504.05865 [pdf] - 1579629
First detection of tracks of radon progeny recoils by MIMAC
Riffard, Q.;
Santos, D.;
Bosson, G.;
Bourrion, O.;
Descombes, T.;
Fourel, C.;
Guillaudin, O.;
Muraz, J. -F.;
Colas, P.;
Ferrer-Ribas, E.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Lebreton, L.;
Maire, D.
Submitted: 2015-04-22, last modified: 2017-06-20
The MIMAC experiment is a $\mu$-TPC matrix project for directional dark
matter search. Directional detection is a strategy based on the measurement of
the WIMP flux anisotropy due to the solar system motion with respect to the
dark matter halo. The main purpose of MIMAC project is the measurement of the
energy and the direction of nuclear recoils in 3D produced by elastic
scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the
Modane underground laboratory. In this paper, we report the first ionization
energy and 3D track observations of nuclear recoils produced by the radon
progeny. This measurement shows the capability of the MIMAC detector and opens
the possibility to explore the low energy recoil directionality signature.
[4]
oai:arXiv.org:1607.08765 [pdf] - 1446365
Directional detection of Dark Matter with the MIcro-tpc MAtrix of
Chambers
Couturier, C.;
Guillaudin, O.;
Naraghi, F.;
Riffard, Q.;
Santos, D.;
Sauzet, N.;
Colas, P.;
Ribas, E. Ferrer;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Zhou, N.
Submitted: 2016-07-29
Particles weakly interacting with ordinary matter, with an associated mass of
the order of an atomic nucleus (WIMPs), are plausible candidates for Dark
Matter. The direct detection of an elastic collision of a target nuclei induced
by one of these WIMPs has to be discriminated from the signal produced by the
neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc
MAtrix of Chambers) collaboration has developed an original prototype detector
which combines a large pixelated Micromegas coupled with a fast,
self-triggering, electronics. Aspects of the two-chamber module in operation in
the Modane Underground Laboratory are presented: calibration, characterization
of the $^{222}$Rn progeny. A new test bench combining a MIMAC chamber with the
COMIMAC portable quenching line has been set up to characterize the 3D tracks
of low energy ions in the MIMAC gas mixture: the preliminary results thereof
are presented. Future steps are briefly discussed.
[5]
oai:arXiv.org:1602.01738 [pdf] - 1483260
MIMAC low energy electron-recoil discrimination measured with fast
neutrons
Riffard, Q.;
Santos, D.;
Guillaudin, O.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Descombes, T.;
Muraz, J. -F.;
Lebreton, L.;
Maire, D.;
Colas, P.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Brunner, J.;
Tao, C.
Submitted: 2016-02-04, last modified: 2016-07-04
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter
detector project. Direct dark matter experiments need a high level of
electron/recoil discrimination to search for nuclear recoils produced by
WIMP-nucleus elastic scattering. In this paper, we proposed an original method
for electron event rejection based on a multivariate analysis applied to
experimental data acquired using monochromatic neutron fields. This analysis
shows that a $10^5$ rejection power is reachable for electron/recoil
discrimination. Moreover, the efficiency was estimated by a Monte-Carlo
simulation showing that a 105 electron rejection power is reached with a
$86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range
and $94.67\pm0.19$\% considering a 5~keV lower threshold.
[6]
oai:arXiv.org:1503.04561 [pdf] - 1376478
Search for chameleons with CAST
Anastassopoulos, V.;
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Christensen, F.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Desch, K.;
Dermenev, A.;
Eleftheriadis, C.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Friedrich, P.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Giomataris, I.;
Hailey, C.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakobsen, A.;
Jakovčić, K.;
Kaminski, J.;
Karuza, M.;
Kavuk, M.;
Krčmar, M.;
Krieger, C.;
Krüger, A.;
Lakić, B.;
Laurent, J. M.;
Liolios, A.;
Ljubičić, A.;
Luzón, G.;
Neff, S.;
Ortega, I.;
Papaevangelou, T.;
Pivovarov, M. J.;
Raffelt, G.;
Riege, H.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Solanki, S. K.;
Vafeiadis, T.;
Villar, J. A.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.;
Brax, P.;
Lavrentyev, I.;
Upadhye, A.
Submitted: 2015-03-16, last modified: 2016-03-18
In this work we present a search for (solar) chameleons with the CERN Axion
Solar Telescope (CAST). This novel experimental technique, in the field of dark
energy research, exploits both the chameleon coupling to matter ($\beta_{\rm
m}$) and to photons ($\beta_{\gamma}$) via the Primakoff effect. By reducing
the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV
CAST became sensitive to the converted solar chameleon spectrum which peaks
around 600$\,$eV. Even though we have not observed any excess above background,
we can provide a 95% C.L. limit for the coupling strength of chameleons to
photons of $\beta_{\gamma}\!\lesssim\!10^{11}$ for $1<\beta_{\rm m}<10^6$.
[7]
oai:arXiv.org:1509.06190 [pdf] - 1323484
A Micromegas-based low-background x-ray detector coupled to a
slumped-glass telescope for axion research
Aznar, F.;
Castel, J.;
Christensen, F. E.;
Dafni, T.;
Decker, T. A.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Giomataris, I.;
Gracia, J. G.;
Hailey, C. J.;
Hill, R. M.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakobsen, A. C.;
Luzon, G.;
Mirallas, H.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Ruz, J.;
Vafeiadis, T.;
Vogel, J. K.
Submitted: 2015-09-21
We report on the design, construction and operation of a low background x-ray
detection line composed of a shielded Micromegas (micromesh gaseous structure)
detector of the microbulk technique. The detector is made from radiopure
materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m
focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of
thermally-formed (or "slumped") glass substrates deposited with multilayer
coatings. The system has been conceived as a technological pathfinder for the
future International Axion Observatory (IAXO), as it combines two of the
techniques (optic and detector) proposed in the conceptual design of the
project. It is innovative for two reasons: it is the first time an x-ray optic
has been designed and fabricated specifically for axion research, and the first
time a Micromegas detector has been operated with an x-ray optic. The line has
been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and
is currently looking for solar axions. The combination of the XRT and
Micromegas detector provides the best signal-to-noise ratio obtained so far by
any detection system of the CAST experiment with a background rate of
5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and
signal spot area.
[8]
oai:arXiv.org:1508.03006 [pdf] - 1330987
Exploring 0.1-10$\,$eV axions with a new helioscope concept
Galán, J.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Iguaz, F. J.;
Irastorza, I. G.;
García, J. A.;
Gracia, J.;
Luzón, G.;
Papaevangelou, T.;
Redondo, J.;
Tomás, A.
Submitted: 2015-08-12, last modified: 2015-09-07
We explore the possibility to develop a new axion helioscope type, sensitive
to the higher axion mass region favored by axion models. We propose to use a
low background large volume TPC immersed in an intense magnetic field. Contrary
to traditional tracking helioscopes, this detection technique takes advantage
of the capability to directly detect the photons converted on the buffer gas
which defines the axion mass sensitivity region, and does not require pointing
the magnet to the Sun. The operation flexibility of a TPC to be used with
different gas mixtures (He, Ne, Xe, etc) and pressures (from 10 mbar to 10 bar)
will allow to enhance sensitivity for axion masses from few meV to several eV.
We present different helioscope data taking scenarios, considering detection
efficiency and axion absorption probability, and show the sensitivities
reachable with this technique to be few $\times$ 10$^{-11}\,$GeV$^{-1}$ for a
5$\,$T$\,$m$^3$ scale TPC. We show that a few years program taking data with
such setup would allow to probe the KSVZ axion model for axion masses above 100
meV.
[9]
oai:arXiv.org:1501.01466 [pdf] - 918435
Lowering the background level and the energy threshold of Micromegas
x-ray detectors for axion searches
Iguaz, F. J.;
Aune, S.;
Aznar, F.;
Castel, J. F.;
Dafni, T.;
Davenport, M.;
Ferrer-Ribas, E.;
Galan, J.;
Garcia, J. A.;
Garza, J. G.;
Giomataris, I.;
Irastorza, I. G.;
Papaevangelou, T.;
Rodriguez, A.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2015-01-07
Axion helioscopes search for solar axions by their conversion in x-rays in
the presence of high magnetic fields. The use of low background x-ray detectors
is an essential component contributing to the sensitivity of these searches. In
this work, we review the recent advances on Micromegas detectors used in the
CERN Axion Solar Telescope (CAST) and proposed for the future International
Axion Observatory (IAXO). The actual setup in CAST has achieved background
levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than
the first generation of Micromegas detectors. This reduction is based on active
and passive shielding techniques, the selection of radiopure materials, offline
discrimination techniques and the high granularity of the readout. We describe
in detail the background model of the detector, based on its operation at CAST
site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4
simulations. The best levels currently achieved at LSC are low than 10$^{-7}$
keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of
this technology in IAXO. Finally, we present some ideas and results for
reducing the energy threshold of these detectors below 1 keV, using
high-transparent windows, autotrigger electronics and studying the cluster
shape at different energies. As a high flux of axion-like-particles is expected
in this energy range, a sub-keV threshold detector could enlarge the physics
case of axion helioscopes.
[10]
oai:arXiv.org:1412.0161 [pdf] - 904473
Background optimization for a new spherical gas detector for very light
WIMP detection
Dastgheibi-Fard, Ali;
Giomataris, I.;
Gerbierb, G.;
Derree, J.;
Gros, M.;
Magnier, P.;
Jourde, D.;
Bougamont, E .;
Navick, X-F.;
Papaevangelou, T.;
Galan, J.;
Tsiledakis, G.;
Piquemal, F.;
Zampaolo, M.;
Loaiza, P.;
Savvidis, I.
Submitted: 2014-11-29
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a
novel type of par- ticle detector, with a broad range of applications. Its main
features include a very low energy threshold independent of the volume (due to
its very low capacitance), a good energy resolution, robustness and a single
detection readout channel, in its simplest version. Applications range from
radon emanation gas monitoring, neutron flux and gamma counting and
spectroscopy to dark matter searches, in particular low mass WIMPs and coherent
neutrino scattering measure- ment. Laboratories interested in these various
applications share expertise within the NEWS (New Experiments With Sphere)
network. SEDINE, a low background prototype installed at underground site of
Laboratoire Souterrain de Modane is currently being operated and aims at
measuring events at very low energy threshold, around 100 eV. We will present
the energy cali- bration with 37Ar, the surface background reduction, the
measurement of detector background at sub-keV energies, and show anticipated
sensitivities for light dark matter search.
[11]
oai:arXiv.org:1307.1985 [pdf] - 867037
CAST solar axion search with 3^He buffer gas: Closing the hot dark
matter gap
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Brauninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Da Riva, E.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Friedrich, P.;
Galan, J.;
Garcia, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Georgiopoulou, E.;
Giomataris, I.;
Gninenko, S.;
Gomez, H.;
Marzoa, M. Gomez;
Gruber, E.;
Guthorl, T.;
Hartmann, R.;
Hauf, S.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovcic, K.;
Karuza, M.;
Konigsmann, K.;
Kotthaus, R.;
Krcmar, M.;
Kuster, M.;
Lakic, B.;
Lang, P. M.;
Laurent, J. M.;
Liolios, A.;
Ljubicic, A.;
Lozza, V.;
Luzon, G.;
Neff, S.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Riege, H.;
Rodriguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Shilon, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomas, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2013-07-08, last modified: 2014-09-15
The CERN Axion Solar Telescope (CAST) has finished its search for solar
axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV.
This closes the gap to the cosmological hot dark matter limit and actually
overlaps with it. From the absence of excess X-rays when the magnet was
pointing to the Sun we set a typical upper limit on the axion-photon coupling
of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on
the pressure setting. Future direct solar axion searches will focus on
increasing the sensitivity to smaller values of g_a, for example by the
currently discussed next generation helioscope IAXO.
[12]
oai:arXiv.org:1401.7902 [pdf] - 778183
NEWS : a new spherical gas detector for very low mass WIMP detection
Gerbier, G.;
Giomataris, I.;
Magnier, P.;
Dastgheibi, A.;
Gros, M.;
Jourde, D.;
Bougamont, E.;
Navick, X. F.;
Papaevangelou, T.;
Galan, J.;
Derre, J.;
Savvidis, I.;
Tsiledakis, G.
Submitted: 2014-01-30
The main characteristics of a new concept of spherical gaseous detectors,
with some details on its operation are first given. The very low energy
threshold of such detector has led to investigations of its potential
performance for dark matter particle searches, in particular low mass WIMP's :
original methods for energy and fiducial volume calibration and background
rejection are described and preliminary results obtained with a low
radioactivity prototype operated in Laboratoire Souterrain de Modane ("Frejus"
lab) are presented. Typical expected sensitivities in cross section for low
mass WIMP's are also shown, and other applications briefly discussed.
[13]
oai:arXiv.org:1310.4092 [pdf] - 732627
Extending axions searches with a spherical TPC
Submitted: 2013-10-15
We present the prospects for detection of KK-axions using a large volume
spherical TPC through natural decay to two gammas. The higher excited mass
states of this axion model allows to reach densities which could be detectable
by this method. We show the capability of this detector to detect 2-prong
events coming from rest-mass axion decays and we provide efficiencies obtained
under some gas mixtures and pressure conditions. The sensitivity limit of a
future experiment with existing detectors geometry has been estimated for the
case of zero background limit.
[14]
oai:arXiv.org:1302.6283 [pdf] - 928601
CAST constraints on the axion-electron coupling
Barth, K.;
Belov, A.;
Beltran, B.;
Brauninger, H.;
Carmona, J. M.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Di Lella, L.;
Eleftheriadis, C.;
Englhauser, J.;
Fanourakis, G.;
Ribas, E. Ferrer;
Fischer, H.;
Franz, J.;
Friedrich, P.;
Galan, J.;
Garcia, J. A.;
Geralis, T.;
Giomataris, I.;
Gninenko, S.;
Gomez, H.;
Hassinoff, M. D.;
Heinsius, F. H.;
Hoffmann, D. H. H.;
Irastorza, I. G.;
Jacoby, J.;
Jakovcic, K.;
Kang, D.;
Konigsmann, K.;
Kotthaus, R.;
Kousouris, K.;
Krcmar, M.;
Kuster, M.;
Lakic, B.;
Liolios, A.;
Ljubicic, A.;
Lutz, G.;
Luzon, G.;
Miller, D. W.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Redondo, J.;
Riege, H.;
Rodriguez, A.;
Ruz, J.;
Savvidis, I.;
Semertzidis, Y.;
Stewart, L.;
Van Bibber, K.;
Vieira, J. D.;
Villar, J. A.;
Vogel, J. K.;
Walckiers, L.;
Zioutas, K.
Submitted: 2013-02-25, last modified: 2013-04-19
In non-hadronic axion models, which have a tree-level axion-electron
interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton
scattering, and axio-recombination, the "BCA processes." Based on a new
calculation of this flux, including for the first time axio-recombination, we
derive limits on the axion-electron Yukawa coupling g_ae and axion-photon
interaction strength g_ag using the CAST phase-I data (vacuum phase). For m_a <
10 meV/c2 we find g_ag x g_ae< 8.1 x 10^-23 GeV^-1 at 95% CL. We stress that a
next-generation axion helioscope such as the proposed IAXO could push this
sensitivity into a range beyond stellar energy-loss limits and test the
hypothesis that white-dwarf cooling is dominated by axion emission.
[15]
oai:arXiv.org:1304.2255 [pdf] - 1165808
MIMAC: A micro-tpc matrix for dark matter directional detection
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, C.;
Guillaudin, O.;
Lamblin, J.;
Muraz, J. F.;
Mayet, F.;
Richer, J. P.;
Riffard, Q.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-04-08
The dark matter directional detection opens a new field in cosmology bringing
the possibility to build a map of nuclear recoils that would be able to explore
the galactic dark matter halo giving access to a particle characterization of
such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers)
collaboration has developed in the last years an original prototype detector
based on the direct coupling of large pixelized micromegas with a devoted fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The discovery potential of this search strategy is
discussed and illustrated. In June 2012, the first bi-chamber prototype has
been installed at Modane Underground Laboratory (LSM) and the first underground
background events, the gain stability and calibration are shown.
[16]
oai:arXiv.org:1210.3287 [pdf] - 1152052
Micromegas-TPC operation at high pressure in xenon-trimethylamine
mixtures
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Gonzalez-Diaz, D.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Rodríguez, A.;
Segui, L.;
Tomás, A.
Submitted: 2012-10-11, last modified: 2012-11-23
In this work we present a systematic study of Micromegas detectors in high
pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains
and energy resolutions for 22.1 keV X-rays are measured for pressures between 1
and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We
observe stable operation at all pressures, and a strongly enhanced gas gain,
suggestive of Penning-like energy-transfer processes. The effect is present at
all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3
%. Operating in this concentration range, the maximum gain reached values as
high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable
for 22.1 keV X-rays is substantially better than the one previously obtained in
pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of
interest for calorimetric applications of high pressure gas Xe TPCs, in
particular for the search of the neutrinoless double beta decay of Xe-136. The
resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value
of Xe-136 for 1 (10) bar.
[17]
oai:arXiv.org:1209.6347 [pdf] - 1453905
Results and perspectives of the solar axion search with the CAST
experiment
Ferrer-Ribas, E.;
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Ezer, C.;
Fanourakis, G.;
Friedrich, P.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Giomataris, I.;
Gninenko, S.;
Gómez, H.;
Gruber, E.;
Guthörl, T.;
Hartmann, R.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovčić, K.;
Karuza, M.;
Königsmann, K.;
Kotthaus, R.;
Krčmar, M.;
Kuster, M.;
Lakić, B.;
Laurent, J. M.;
Liolios, A.;
Ljubičić, A.;
Lozza, V.;
Lutz, G.;
Luzón, G.;
Morales, J.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Rashba, T.;
Riege, H.;
Rodríguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomás, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2012-09-27, last modified: 2012-10-30
The status of the solar axion search with the CERN Axion Solar Telescope
(CAST) will be presented. Recent results obtained by the use of $^3$He as a
buffer gas has allowed us to extend our sensitivity to higher axion masses than
our previous measurements with $^4$He. With about 1 h of data taking at each of
252 different pressure settings we have scanned the axion mass range 0.39 eV$
\le m_{a} \le $ 0.64 eV. From the absence of an excess of x rays when the
magnet was pointing to the Sun we set a typical upper limit on the axion-photon
coupling of g$_{a\gamma} \le 2.3\times 10^{-10}$ GeV$^{-1}$ at 95% C.L., the
exact value depending on the pressure setting. CAST published results represent
the best experimental limit on the photon couplings to axions and other similar
exotic particles dubbed WISPs (Weakly Interacting Slim Particles) in the
considered mass range and for the first time the limit enters the region
favored by QCD axion models. Preliminary sensitivities for axion masses up to
1.16 eV will also be shown reaching mean upper limits on the axion-photon
coupling of g$_{a\gamma} \le 3.5\times 10^{-10}$ GeV$^{-1}$ at 95% C.L.
Expected sensibilities for the extension of the CAST program up to 2014 will be
presented. Moreover long term options for a new helioscope experiment will be
evoked.
[18]
oai:arXiv.org:1208.5690 [pdf] - 771411
CAST microbulk micromegas in the Canfranc Underground Laboratory
Tomás, A.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gómez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Papaevangelou, T.;
Rodríguez, A.;
Ruz, J.;
Seguí, L.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2012-08-28
During the last taking data campaigns of the CAST experiment, the micromegas
detectors have achieved background levels of $\approx 5 \times
10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has
been possible thanks to the introduction of the microbulk technology, the
implementation of a shielding and the development of discrimination algorithms.
It has motivated new studies towards a deeper understanding of CAST detectors
background. One of the working lines includes the construction of a replica of
the set-up used in CAST by micromegas detectors and its installation in the
Canfranc Underground Laboratory. Thanks to the comparison between the
performance of the detectors underground and at surface, shielding upgrades,
etc, different contributions to the detectors background have been evaluated.
In particular, an upper limit $< 2 \times 10^{-7}$keV$^{-1}$cm$^{-2}$s$^{-1}$
for the intrinsic background of the detector has been obtained. This work means
a first evaluation of the potential of the newest micromegas technology in an
underground laboratory, the most suitable environment for Rare Event Searches.
[19]
oai:arXiv.org:1201.3012 [pdf] - 1092971
Characterization of microbulk detectors in argon- and neon-based
mixtures
Submitted: 2012-01-14
A recent Micromegas manufacturing technique, so called Microbulk, has been
developed, improving the uniformity and stability of this kind of detectors.
Excellent energy resolutions have been obtained, reaching values as low as 11%
FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its
flexible structure, low material budget and high radio-purity. Two microbulk
detectors with gaps of 50 and 25 um have been characterized in argon- and
neon-based mixtures with ethane, isobutane and cyclohexane. The results will be
presented and discussed. The gain curves have been fitted to the Rose-Korff
gain model and dependences of the electron mean free path and the threshold
energy for ionization have been obtained. The possible relation between these
two parameters and the energy resolution will be also discussed.
[20]
oai:arXiv.org:1111.1566 [pdf] - 435178
MIMAC: A micro-tpc matrix project for directional detection of dark
matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-11-07
Directional detection of non-baryonic DarkMatter is a promising search
strategy for discriminating WIMP events from background ones. This strategy
requires both a measurement of the recoil energy down to a few keV and 3D
reconstruction of tracks down to a few mm. The MIMAC project, based on a
micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first
results of a chamber prototype of this matrix, on low energy nuclear recoils
(1H and 19F) obtained with mono-energetic neutron fields are presented. The
discovery potential of this search strategy is illustrated by a realistic case
accessible to MIMAC.
[21]
oai:arXiv.org:1110.2608 [pdf] - 1084811
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Galan, J.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gomez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Papaevangelou, T.;
Rodriguez, A.;
Ruz, J.;
Segui, L.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2011-10-12, last modified: 2011-10-25
Micromegas detectors, thanks to the good spatial and temporal discrimination
capabilities, are good candidates for rare event search experiments. Recent
X-ray background levels achieved by these detectors in the CAST experiment have
motivated further studies in the nature of the background levels measured. In
particular, different shielding configurations have been tested at the Canfranc
Underground Laboratory, using a microbulk type detector which was previously
running at the CAST experiment. The first results underground show that this
technology, which is made of low radiative materials, is able to reach
background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a
proper shielding. Moreover, the experimental background measurements are
complemented with Geant4 simulations which allow to understand the origin of
the background, and to optimize future shielding set-ups.
[22]
oai:arXiv.org:1102.3265 [pdf] - 399526
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-02-16
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with CF4 and CHF3. The first results on low energy nuclear recoils (H, F)
obtained with a low mono-energetic neutron field are presented. The discovery
potential of this search strategy is discussed and illustrated by a realistic
case accessible to MIMAC.
[23]
oai:arXiv.org:1012.1166 [pdf] - 955699
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Allaoua, A.;
Golabek, C.;
Lebreton, L.
Submitted: 2010-12-06
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H
and 19F) obtained with a low mono-energetic neutron field are presented. The
discovery potential of this search strategy is discussed and illustrated by a
realistic case accessible to MIMAC.
[24]
oai:arXiv.org:1008.4712 [pdf] - 228441
Directional detection of non-baryonic dark matter with MIMAC
Grignon, C.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Ferrer, E.;
Giomataris, I.;
Mols, J. P.
Submitted: 2010-08-27, last modified: 2010-09-17
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating genuine WIMP events from background ones. However,
carrying out such a strategy requires both a precise measurement of the energy
down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve
this goal, the MIMAC project has been developed: it is based on a gaseous
micro-TPC matrix, filled with 3He, CF4 and/or C4H10. Firsts results of low
energy nuclei recoils obtained with a low energy neutron field are presented.
[25]
oai:arXiv.org:1009.1827 [pdf] - 261761
Micromegas readouts for double beta decay searches
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Giomataris, I.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Rodríguez, A.;
Seguí, L.;
Tomás, A.
Submitted: 2010-09-09
Double beta $\beta\beta$ decay experiments are one of the most active
research topics in Neutrino Physics. The measurement of the neutrinoless mode
$0\nu\beta\beta$ could give unique information on the neutrino mass scale and
nature. The current generation of experiments aims at detector target masses at
the 100 kg scale, while the next generation will need to go to the ton scale in
order to completely explore the inverse hierarchy models of neutrino mass. Very
good energy resolutions and ultra-low background levels are the two main
experimental requirements for a successful experiment. The topological
information of the $\beta\beta$ events offered by gaseous detectors like gas
Time Projection Chambers (TPC) could provide a very powerful tool of signal
identification and background rejection. However only recent advances in TPC
readouts may assure the competitiveness of a high pressure gas TPCs for
$\beta\beta$ searches, especially regarding the required energy resolution. In
this paper we present first results on energy resolution with state-of-the-art
microbulk Micromesh Gas Amplification Structure (Micromegas) using a 5.5 MeV
alpha source in high pressure pure xenon. Resolutions down to 2 % FWHM have
been achieved for pressures up to 5 bar. These results, together with their
recently measured radiopurity , prove that Micromegas readouts are not only a
viable option but a very competitive one for $\beta\beta$ searches.
[26]
oai:arXiv.org:1001.2983 [pdf] - 32880
Directional detection of galactic Dark Matter
Mayet, F.;
Billard, J.;
Bernard, G.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Koumeir, C.;
Richer, J. P.;
Santos, D.;
Colas, P.;
Ferer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2010-01-18
Directional detection of galactic Dark Matter is a promising search strategy
for discriminating geniune WIMP events from background ones. We present
technical progress on gaseous detectors as well as recent phenomenological
studies, allowing the design and construction of competitive experiments.
[27]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[28]
oai:arXiv.org:0909.0654 [pdf] - 901600
A prototype of a directional detector for non-baryonic dark matter
search: MIMAC (Micro-TPC Matrix of Chambers)
Grignon, C.;
Bernard, G.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Koumeir, C.;
Mayet, F.;
Santos, D.;
Colas, P.;
Ferrer, E.;
Giomataris, I.;
Allaoua, A.;
Lebreton, L.
Submitted: 2009-09-03, last modified: 2009-10-30
We have developed a micro-tpc using a pixelized bulk micromegas coupled to
dedicated acquisition electronics as a read-out allowing to reconstruct the
three dimensional track of a few keV recoils. The prototype has been tested
with the Amande facility at the IRSN-Cadarache providing monochromatic
neutrons. The first results concerning discrimination of a few keV electrons
and proton recoils are presented.
[29]
oai:arXiv.org:0905.4800 [pdf] - 24752
Dark matter directional detection with MIMAC
Grignon, C.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Koumeir, C.;
Mayet, F.;
Santos, D.;
Colas, P.;
Ferrer, E.;
Giomataris, I.
Submitted: 2009-05-29
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for
direct detection of non-baryonic dark matter. Measurement of both track and
ionization energy will allow the electron-recoil discrimination, while access
to the directionnality of the tracks will open a unique way to distinguish a
geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV
electrons are presented as a proof of concept.
[30]
oai:arXiv.org:0905.4654 [pdf] - 24724
Micromegas micro-TPC for direct Dark Matter search with MIMAC
Submitted: 2009-05-28
The MIMAC project is a multi-chamber detector for Dark Matter search, aiming
at measuring both track and ionization with a matrix of micromegas micro-TPC
filled with He3 and CF4. Recent experimental results on the first measurements
of the Helium quenching factor at low energy (1 keV recoil) are presented,
together with the first simulation of the track reconstruction. Recontruction
of track of alpha from Radon impurities is shown as a first proof of concept.
[31]
oai:arXiv.org:0904.1667 [pdf] - 23251
Low energy measurements with Helium Micromegas micro-TPC
Submitted: 2009-04-10
The measurement of the ionization produced by particles in a medium presents
a great interest in several fields from metrology to particule physics and
cosmology. The ionization quenching factor is defined as the fraction of energy
released by ionisation by a recoil in a medium compared with its kinetic
energy. At low energy, in the range of a few keV, the ionization falls rapidly
and systematic measurement are needed. We have developped an experimental setup
devoted to the measurement of low energy (keV) ionization quenching factor for
the MIMAC project. The ionization produced in the gas has been measured with a
Micromegas detector filled with Helium gas mixture.
[32]
oai:arXiv.org:0810.1137 [pdf] - 17161
Ionization Quenching Factor Measurement of Helium 4
Submitted: 2008-10-07
The ionization quenching factor (IQF) is defined as the fraction of energy
released by a recoil in a medium through ionization compared with its total
kinetic energy. At low energies, in the range of a few keV, the ionization
produced in a medium falls rapidly and systematic measurements are needed. We
report measurements carried out at such low energies as a function of the
pressure in He4 at 350, 700, 1000 and 1300 mbar. In order to produce a nucleus
moving with a controlled energy in the detection volume, we have developed an
Electron Cyclotron Resonance Ion Source (ECRIS) coupled to an ionization
chamber by a differential pumping. The quenching factor of He4 has been
measured for the first time down to 1 keV recoil energies. An important
deviation with respect to the phenomenological calculations has been found
allowing an estimation of the scintillation produced in He4 as a function of
pressure. The variation of the IQF as a function of the percentage of
isobutane, used as quencher, is also presented.