sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Gilson, Erik

Normalized to: Gilson, E.

2 article(s) in total. 9 co-authors, from 1 to 2 common article(s). Median position in authors list is 4,5.

[1]  oai:arXiv.org:1801.03569  [pdf] - 1797132
Experimental Confirmation of the Standard Magnetorotational Instability Mechanism with a Spring-Mass Analogue
Comments: 7 pages; 4 figures; accepted by Communications Physics
Submitted: 2018-01-10, last modified: 2018-12-11
The Magnetorotational Instability (MRI) has long been considered a plausibly ubiquitous mechanism to destabilize otherwise stable Keplerian flows to support radially outward transport of angular momentum. Such an efficient transport process would allow fast accretion in astrophysical objects such as stars and black holes to release copious kinetic energy that powers many of the most luminous sources in the universe. But the standard MRI under a purely vertical magnetic field has heretofore never been directly measured despite numerous efforts over more than a decade. Here we report an unambiguous laboratory demonstration of the spring-mass analogue to the standard MRI by comparing motion of a spring-tethered ball within different rotating flows. The experiment corroborates the theory: efficient outward angular momentum transport manifests only for cases with a weak spring in quasi-Keperian flow. Our experimental method accomplishes this in a new way, thereby connecting solid and fluid mechanics to plasma astrophysics.
[2]  oai:arXiv.org:1612.01224  [pdf] - 1532996
Numerical simulations of the Princeton magneto-rotational instability experiment with conducting axial boundaries
Comments:
Submitted: 2016-12-04
We investigate numerically the Princeton magneto-rotational instability (MRI) experiment and the effect of conducting axial boundaries or endcaps. MRI is identified and found to reach a much higher saturation than for insulating endcaps. This is probably due to stronger driving of the base flow by the magnetically rather than viscously coupled boundaries. Although the computations are necessarily limited to lower Reynolds numbers ($\Re$) than their experimental counterparts, it appears that the saturation level becomes independent of $\Re$ when $\Re$ is sufficiently large, whereas it has been found previously to decrease roughly as $\Re^{-1/4}$ with insulating endcaps. The much higher saturation levels will allow for the first positive detection of MRI beyond its theoretical and numerical predictions.