sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Giboni, K. L.

Normalized to: Giboni, K.

50 article(s) in total. 314 co-authors, from 1 to 43 common article(s). Median position in authors list is 10,5.

[1]  oai:arXiv.org:1708.05825  [pdf] - 1598121
Exploring the dark matter inelastic frontier with 79.6 days of PandaX-II data
Comments: 5 pages, 6 figures
Submitted: 2017-08-19, last modified: 2017-10-03
We report here the results of searching for inelastic scattering of dark matter (initial and final state dark matter particles differ by a small mass splitting) with nucleon with the first 79.6-day of PandaX-II data (Run 9). We set the upper limits for the spin independent WIMP-nucleon scattering cross section up to a mass splitting of 300 keV/c$^2$ at two benchmark dark matter masses of 1 and 10 TeV/c$^2$.
[2]  oai:arXiv.org:1707.07921  [pdf] - 1586345
Limits on Axion Couplings from the first 80-day data of PandaX-II Experiment
Comments: 5 pages, 4 figures
Submitted: 2017-07-25, last modified: 2017-10-02
We report new searches for the solar axions and galactic axion-like dark matter particles, using the first low-background data from PandaX-II experiment at China Jinping Underground Laboratory, corresponding to a total exposure of about $2.7\times 10^4$ kg$\cdot$day. No solar axion or galactic axion-like dark matter particle candidate has been identified. The upper limit on the axion-electron coupling ($g_{Ae}$) from the solar flux is found to be about $4.35 \times 10^{-12}$ in mass range from $10^{-5}$ to 1 keV/$c^2$ with 90\% confidence level, similar to the recent LUX result. We also report a new best limit from the $^{57}$Fe de-excitation. On the other hand, the upper limit from the galactic axions is on the order of $10^{-13}$ in the mass range from 1 keV/$c^2$ to 10 keV/$c^2$ with 90\% confidence level, slightly improved compared with the LUX.
[3]  oai:arXiv.org:1708.06917  [pdf] - 1587379
Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
Comments: Supplementary materials at https://pandax.sjtu.edu.cn/articles/2nd/supplemental.pdf version 2 as accepted by PRL
Submitted: 2017-08-23, last modified: 2017-09-21
We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day, improved by a factor of 2.5 in comparison to the previous run in 2016. No excess events were found above the expected background. With a total exposure of 5.4$\times10^4$ kg day, the most stringent upper limit on spin-independent WIMP-nucleon cross section was set for a WIMP with mass larger than 100 GeV/c$^2$, with the lowest exclusion at 8.6$\times10^{-47}$ cm$^2$ at 40 GeV/c$^2$.
[4]  oai:arXiv.org:1708.07051  [pdf] - 1697916
The XENON1T Dark Matter Experiment
XENON Collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Antunes, B.; Arneodo, F.; Balata, M.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breskin, A.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Chiarini, A.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Corrieri, R.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Disdier, J. -M.; Doets, M.; Duchovni, E.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Florin, D.; Front, D.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Giboni, K. -L.; Goetzke, L. W.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Huhmann, C.; Itay, R.; James, A.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Maier, R.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Orlandi, D.; Othegraven, R.; Pakarha, P.; Parlati, S.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; García, D. Ramírez; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Saldahna, R.; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Sivers, M. v.; Stern, M.; Stein, A.; Tatananni, D.; Tatananni, L.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Wack, O.; Walet, R.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.
Comments: 22 pages, 25 figures
Submitted: 2017-08-23
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.
[5]  oai:arXiv.org:1611.06553  [pdf] - 1532729
Spin-Dependent Weakly-Interacting-Massive-Particle--Nucleon Cross Section Limits from First Data of PandaX-II Experiment
Comments: 5 pages, 5 figures, version accepted for publication in PRL
Submitted: 2016-11-20, last modified: 2017-02-14
New constraints are presented on the spin-dependent WIMP-nucleon interaction from the PandaX-II experiment, using a data set corresponding to a total exposure of 3.3$\times10^4$ kg-days. Assuming a standard axial-vector spin-dependent WIMP interaction with $^{129}$Xe and $^{131}$Xe nuclei, the most stringent upper limits on WIMP-neutron cross sections for WIMPs with masses above 10 GeV/c$^{2}$ are set in all dark matter direct detection experiments. The minimum upper limit of $4.1\times 10^{-41}$ cm$^2$ at 90\% confidence level is obtained for a WIMP mass of 40 GeV/c$^{2}$. This represents more than a factor of two improvement on the best available limits at this and higher masses. These improved cross-section limits provide more stringent constraints on the effective WIMP-proton and WIMP-neutron couplings.
[6]  oai:arXiv.org:1505.00771  [pdf] - 1280844
Low-mass dark matter search results from full exposure of PandaX-I experiment
Comments: v3 as accepted by PRD. Minor update in the text in response to referee comments. Separating Fig. 11(a) and (b) into Fig. 11 and Fig. 12. Legend tweak in Fig. 9(b) and 9(c) as suggested by referee, as well as a missing legend for CRESST-II legend in Fig. 12 (now Fig. 13). Same version as submitted to PRD
Submitted: 2015-05-04, last modified: 2015-08-20
We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on the low mass WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.
[7]  oai:arXiv.org:1408.5114  [pdf] - 863825
First dark matter search results from the PandaX-I experiment
Comments: 7 pages, 6 figures, final version as appeared in the journal publication
Submitted: 2014-08-21, last modified: 2014-09-04
We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positive experimental results. The minimum upper limit, $3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar DM-particle-nucleon scattering cross section is obtained at a DM-particle mass of 49\,GeV/c$^2$ at 90\% confidence level.
[8]  oai:arXiv.org:1311.1088  [pdf] - 783783
Observation and applications of single-electron charge signals in the XENON100 experiment
Comments: 16 pages, 8 figures. Accepted for publication in Journal of Physics G: Nuclear and Particle Physics
Submitted: 2013-11-05, last modified: 2014-01-28
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
[9]  oai:arXiv.org:1207.3458  [pdf] - 1693882
Analysis of the XENON100 Dark Matter Search Data
Comments: 18 pages, 17 figures, information for the 224.6 live days run included
Submitted: 2012-07-14, last modified: 2013-10-14
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have been used in the 100.9 and 224.6 live days science runs from which results on spin-independent elastic, spin-dependent elastic and inelastic WIMP-nucleon cross-sections have already been reported.
[10]  oai:arXiv.org:1306.2303  [pdf] - 1171929
The neutron background of the XENON100 dark matter experiment
Comments:
Submitted: 2013-06-10, last modified: 2013-09-02
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($\alpha$,n) and spontaneous fission reactions due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on Monte Carlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by the XENON100 experiment in 2011 and 2012, 0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively, and conclude that they do not limit the sensitivity of the experiment.
[11]  oai:arXiv.org:1304.1427  [pdf] - 705114
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
Comments: 10 pages, 10 figures. Matches version accepted by PRD. Contains revised representation of expected WIMP event signature. Conclusions remain unaffected
Submitted: 2013-04-04, last modified: 2013-07-18
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matter searches of the XENON100 experiment.
[12]  oai:arXiv.org:1104.3088  [pdf] - 661239
A search for light dark matter in XENON10 data
Comments: Manuscript identical to v2 (published version) but also contains erratum. Note v3==v2 but without \linenumbers
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic dark matter interpretations of excess low-energy events observed by CoGeNT and CRESST-II, as well as the DAMA annual modulation signal.
[13]  oai:arXiv.org:1207.5988  [pdf] - 642231
Dark Matter Results from 225 Live Days of XENON100 Data
Comments: 6 pages, 5 figures. Matches version accepted by PRL. Includes limits up to 10 TeV/c^2, published as supplementary material: http://prl.aps.org/supplemental/PRL/v109/i18/e181301 Please cite high mass limits as "Phys. Rev. Lett. 109, 181301 (2012), online supplementary material."
Submitted: 2012-07-25, last modified: 2013-03-20
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on the spin-independent elastic WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2 and 90% confidence level.
[14]  oai:arXiv.org:1101.3866  [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
Comments: 10 pages, 12 figures The updated version of the paper takes into account the new measurement of $^{136}$Xe 2$\nu$ $\beta\beta$ decay by EXO-200, with a half-life of (2.11$\pm0.04\pm$0.021)$\times10^{21}$ years
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We present a comprehensive study of the predicted electronic recoil background coming from radioactive decays inside the detector and shield materials, and intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a detailed geometry together with the measured radioactivity of all detector components, we predict an electronic recoil background in the WIMP-search energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2 events/(kg-day-keV), consistent with the experiment's design goal. The predicted background spectrum is in very good agreement with the data taken during the commissioning of the detector, in Fall 2009.
[15]  oai:arXiv.org:1301.6620  [pdf] - 704634
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
Comments: 5 pages, 3 figures; corrected caption of figure 3
Submitted: 2013-01-28, last modified: 2013-01-29
We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x 10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
[16]  oai:arXiv.org:1211.0836  [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Comments: 12 pages, 4 figures
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.
[17]  oai:arXiv.org:1209.3658  [pdf] - 673149
Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid Xenon
Comments: 14 pages, 8 figures
Submitted: 2012-09-17
We have measured the energy dependence of the liquid xenon (LXe) scintillation yield of electrons with energy between 2.1 and 120.2keV, using the Compton coincidence technique. A LXe scintillation detector with a very high light detection efficiency was irradiated with 137Cs {\gamma} rays and the energy of the Compton-scattered {\gamma} rays was measured with a high-purity germanium (HPGe) detector placed at different scattering angles. The excellent energy resolution of the HPGe detector allows the selection of events with Compton electrons of known energy in the LXe detector. We find that the scintillation yield initially increases as the electron energy decreases from 120 keV to about 60keV but then decreases by about 30% from 60keV to 2keV. The measured scintillation yield was also measured with conversion electrons from the 32.1 keV and 9.4 keV transitions of the 83mKr isomer, used as an internal calibration source. We find that the scintillation yield of the 32.1 keV transition is compatible with that obtained from the Compton coincidence measurement. On the other hand, the yield for the 9.4keV transition is much higher than that measured for a Compton electron of the same energy. We interpret the enhancement in the scintillation yield as due to the enhanced recombination rate in the presence of Xe ions left from the 32.1 keV transition, which precedes the 9.4 keV one by 220 ns, on average.
[18]  oai:arXiv.org:1208.5762  [pdf] - 555466
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
Comments: 3 pages, no figures
Submitted: 2012-08-28
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the rationale for not considering the described effect in our final analysis and list several potential problems with his study.
[19]  oai:arXiv.org:1207.5432  [pdf] - 1125033
Measurement of the Quantum Efficiency of Hamamatsu R8520 Photomultipliers at Liquid Xenon Temperature
Comments:
Submitted: 2012-07-23
Vacuum ultraviolet light sensitive photomultiplier tubes directly coupled to liquid xenon are being used to efficiently detect the 178 nm scintillation light in a variety of liquid xenon based particle detectors. Good knowledge of the performance of these photomultipliers under cryogenic conditions is needed to properly characterize these detectors. Here, we report on measurements of the quantum efficiency of Hamamatsu R8520 photomultipliers, used in the XENON Dark Matter Experiments. The quantum efficiency measurements at room temperature agree with the values provided by Hamamatsu. At low temperatures, between 160K and 170K, the quantum efficiency increases by $\sim5-11$% relative to the room temperature values.
[20]  oai:arXiv.org:1207.5100  [pdf] - 1125005
The Cryogenic System for the Panda-X Dark Matter Search Experiment
Comments: 10 pages, 5 figures
Submitted: 2012-07-21
Panda-X is a liquid xenon dual-phase detector for the Dark Matter Search. The first modestly-sized module will soon be installed in the China JinPing Deep Underground Laboratory in Sichuan province, P.R. China. The cryogenics system is designed to handle much larger detectors, even the final version in the ton scale. Special attention has been paid to the reliability, serviceability, and adaptability to the requirements of a growing experiment. The system is cooled by a single Iwatani PC150 Pulse Tube Refrigerator. After subtracting all thermal losses, the remaining cooling power is still 82W. The fill speed was 9 SLPM, but could be boosted by LN2 assisted cooling to 40 SLPM. For the continuous recirculation and purification through a hot getter, a heat exchanger was employed to reduce the required cooling power. The recirculation speed is limited to 35 SLPM by the gas pump. At this speed, recirculation only adds 18.5 W to the heat load of the system, corresponding to a 95.2 % efficiency of the heat exchanger.
[21]  oai:arXiv.org:1107.2155  [pdf] - 474250
The XENON100 Dark Matter Experiment
Comments: 23 pages, 27 figures; version accepted by journal
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science runs. The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating inside the liquid or in Xe gas. The LXe target and veto are contained in a low-radioactivity stainless steel vessel, embedded in a passive radiation shield. The experiment is installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy and has recently published results from a 100 live-days dark matter search. The ultimate design goal of XENON100 is to achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of \sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[22]  oai:arXiv.org:1109.4270  [pdf] - 427699
Limits on the release of Rb isotopes from a zeolite based 83mKr calibration source for the XENON project
Comments: 11 pages, 7 figures, submitted to Journal of Instrumentation
Submitted: 2011-09-20, last modified: 2011-10-06
The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source for a liquid noble gas dark matter experiment like the XENON project. However, the risk of contamination of the detector with traces of the much longer lived mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has been investigated. To do so, a cryogenic trap has been connected to the source for about 10 days, after which it was removed and probed for the strongest 83Rb gamma-rays with an ultra-sensitive Germanium detector. No signal has been found. The corresponding upper limit on the released 83Rb activity means that the investigated type of source can be used in the XENON project and similar low-background experiments as 83mKr generator without a significant risk of contaminating the detector. The measurements also allow to set upper limits on the possible release of the isotopes 84Rb and 86Rb, traces of which were created alongside the production of 83Rb at the Rez cyclotron.
[23]  oai:arXiv.org:1104.3121  [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
Comments: 3 pages, 3 figures
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 \pm 0.6) events. Based on this analysis we present limits on the WIMP-nucleon cross section for inelastic dark matter. With the present data we are able to rule out the explanation for the observed DAMA/LIBRA modulation as being due to inelastic dark matter scattering off iodine at a 90% confidence level.
[24]  oai:arXiv.org:1104.2549  [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
Comments: 5 pages, 5 figures; matches accepted version
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90% confidence level.
[25]  oai:arXiv.org:1103.0303  [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
Comments: 8 pages, 6 figures, matches accepted version
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to distinguish a dominant background from the expected feeble signals, based on some measured discrimination parameter. We develop a statistical model for such experiments using the Profile Likelihood ratio as a test statistic in a frequentist approach. We take data from calibrations as control measurements for signal and background, and the method allows the inclusion of data from Monte Carlo simulations. Systematic detector uncertainties, such as uncertainties in the energy scale, as well as astrophysical uncertainties, are included in the model. The statistical model can be used to either set an exclusion limit or to make a discovery claim, and the results are derived with a proper treatment of statistical and systematic uncertainties. We apply the model to the first data release of the XENON100 experiment, which allows to extract additional information from the data, and place stronger limits on the spin-independent elastic WIMP-nucleon scattering cross-section. In particular, we derive a single limit, including all relevant systematic uncertainties, with a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[26]  oai:arXiv.org:1104.2587  [pdf] - 669518
New Measurement of the Scintillation Efficiency of Low-Energy Nuclear Recoils in Liquid Xenon
Comments: 14 pages, 13 figures
Submitted: 2011-04-13
Particle detectors that use liquid xenon (LXe) as detection medium are among the leading technologies in the search for dark matter weakly interacting massive particles (WIMPs). A key enabling element has been the low-energy detection threshold for recoiling nuclei produced by the interaction of WIMPs in LXe targets. In these detectors, the nuclear recoil energy scale is based on the LXe scintillation signal and thus requires knowledge of the relative scintillation efficiency of nuclear recoils, Leff. The uncertainty in Leff at low energies is the largest systematic uncertainty in the reported results from LXe WIMP searches at low masses. In the context of the XENON Dark Matter project, a new LXe scintillation detector has been designed and built specifically for the measurement of Leff at low energies, with an emphasis on maximizing the scintillation light detection efficiency to obtain the lowest possible energy threshold. We report new measurements of Leff at low energies performed with this detector. Our results suggest a Leff which slowly decreases with energy, from 0.144 +/- 0.009 at 15 keV down to 0.088 +0.014 -0.015 at 3 keV.
[27]  oai:arXiv.org:1005.0380  [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
Comments: 5 pages, 5 figures. Matches published version
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62 kg of liquid xenon in an ultra-low background dual-phase time projection chamber. In this letter, we present first dark matter results from the analysis of 11.17 live days of non-blind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the pre-defined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs at 90% confidence level. Below 20 GeV/c^2, this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.
[28]  oai:arXiv.org:0910.3698  [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Comments: 8 pages, 4 figures
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of nuclear recoil events at higher nuclear recoil equivalent energies. This is in stark contrast to the well-known expectation of a falling exponential spectrum for the case of elastic interactions. We present a new analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV nuclear recoil equivalent energy. Our results exclude a significant region of previously allowed parameter space in the model of inelastically interacting dark matter. In particular, it is found that dark matter particle masses $m_{\chi}\gtrsim150$ GeV are disfavored.
[29]  oai:arXiv.org:1011.6439  [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Comments: Conference proceedings from the Identification of Dark Matter 2010, Montpellier, France. To be published by SISSA as PoS(IDM2010)017
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surface events based solely on the ionization signal.
[30]  oai:arXiv.org:0810.0274  [pdf] - 166670
New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV
Comments: 8 pages, 8 figures
Submitted: 2008-10-01, last modified: 2010-05-16
Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative scintillation efficiency of nuclear recoils below 20 keV lead to inconsistent extrapolations at lower energies. This results in a different energy scale and thus sensitivity reach of liquid xenon dark matter detectors. We report a new measurement of the relative scintillation efficiency below 10 keV performed with a liquid xenon scintillation detector, optimized for maximum light collection. Greater than 95% of the interior surface of this detector was instrumented with photomultiplier tubes, giving a scintillation yield of 19.6 photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying constant around this value up to 10 keV. For higher energy recoils we measure a value around 20%, consistent with previously reported data. In light of this new measurement, the XENON10 experiment's results on spin-independent WIMP-nucleon cross section, which were calculated assuming a constant 0.19 relative scintillation efficiency, change from $8.8\times10^{-44}$ cm$^2$ to $9.9\times10^{-44}$ cm$^2$ for WIMPs of mass 100 GeV/c$^2$, and from $4.4\times10^{-44}$ cm$^2$ to $5.6\times10^{-44}$ cm$^2$ for WIMPs of mass 30 GeV/c$^2$.
[31]  oai:arXiv.org:1001.2834  [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Comments:
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulations data. The results on the detector's energy threshold, energy and position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (<10 keVr) and the excellent energy resolution achieved by combining the ionization and scintillation signals, detected simultaneously.
[32]  oai:arXiv.org:0807.0459  [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear recoils
Comments: 8 pages, 9 figures. To be published in Nucl. Instrum. Methods A
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relative scintillation yield \leff and the absolute ionization yield Q_y, for nuclear recoils in xenon. A dark matter particle is expected to deposit energy by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for establishing the energy threshold of the experiment; this in turn determines the sensitivity to particle dark matter. Our \leff measurement is in agreement with recent theoretical predictions above 15 keV nuclear recoil energy, and the energy threshold of the measurement is 4 keV. A knowledge of the ionization yield \Qy is necessary to establish the trigger threshold of the experiment. The ionization yield \Qy is measured in two ways, both in agreement with previous measurements and with a factor of 10 lower energy threshold.
[33]  oai:arXiv.org:0805.2939  [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10 experiment
Comments: 4 pages, 4 figures; final version published in PRL (added DAMA region to Figure 1)
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.
[34]  oai:arXiv.org:0706.0039  [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
Comments: accepted for publication in Phys. Rev. Lett
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4 kg, excludes previously unexplored parameter space, setting a new 90% C.L. upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x 10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a WIMP mass of 30 GeV/c^2. This result further constrains predictions of supersymmetric models.
[35]  oai:arXiv.org:0704.1118  [pdf] - 231
Observation of Anti-correlation between Scintillation and Ionization for MeV Gamma-Rays in Liquid Xenon
Comments:
Submitted: 2007-04-09
A strong anti-correlation between ionization and scintillation signals produced by MeV gamma-rays in liquid xenon has been measured and used to improve the energy resolution by combining the two signals. The improvement is explained by reduced electron-ion recombination fluctuations of the combined signal compared to fluctuations of the individual signals. Simultaneous measurements of ionization and scintillation signals were carried out with Cs-137, Na-22 and Co-60 gamma rays, as a function of electric field in the liquid. A resolution of 1.7%(sigma) at 662 keV was measured at 1 kV/cm, significantly better than the resolution from either scintillation or ionization alone. A detailed analysis indicates that further improvement to less than 1%(sigma) is possible with higher light collection efficiency and lower electronic noise.
[36]  oai:arXiv.org:physics/0702078  [pdf] - 119207
A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during the 2000 Balloon Flight Campaign
Comments: 20 pages, 15 figures; submitted to NIMA
Submitted: 2007-02-09
LXeGRIT - Liquid Xenon Gamma-Ray Imaging Telescope - is the first prototype of a Compton telescope for \MeV \g-ray astrophysics based on a LXe time projection chamber. One of the most relevant figures of merit for a Compton telescope is the detection efficiency for \g-rays, which depends on diverse contributions such as detector geometry and passive materials, trigger efficiency, dead time, etc. A detailed study of the efficiency of the LXeGRIT instrument, based both on laboratory measurements and Monte Carlo simulations, is presented in this paper.
[37]  oai:arXiv.org:astro-ph/0609714  [pdf] - 85306
3D Position Sensitive XeTPC for Dark Matter Search
Comments: Presented at the 7th UCLA Symposium on "Sources and Detection of Dark Matter and Dark Energy in the Universe"
Submitted: 2006-09-26
The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.
[38]  oai:arXiv.org:physics/0608034  [pdf] - 119179
Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon
Comments:
Submitted: 2006-08-03, last modified: 2006-08-04
Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency. The detector gives a high light yield of 6 photoelectron per keV (pe/keV), which allows efficient detection of the 122 keV gamma-ray line from Co-57, with a measured energy resolution of (8.8+/-0.6)% (sigma). The best achievable energy resolution, by removing the instrumental fluctuations, from liquid xenon scintillation light is estimated to be around 6-8% (sigma) for gamma-ray with energy between 662 keV and 122 keV.
[39]  oai:arXiv.org:astro-ph/0601552  [pdf] - 79410
Simultaneous Measurement of Ionization and Scintillation from Nuclear Recoils in Liquid Xenon as Target for a Dark Matter Experiment
Comments:
Submitted: 2006-01-24
We report the first measurements of the absolute ionization yield of nuclear recoils in liquid xenon, as a function of energy and electric-field. Independent experiments were carried out with two dual-phase time projection chamber prototypes, developed for the XENON Dark Matter project. We find that the charge yield increases with decreasing recoil energy, and exhibits only a weak field dependence. These results are a first demonstration of the capability of dual phase xenon detectors to discriminate between electron and nuclear recoils, a key requirement for a sensitive dark matter search at recoil energies down to 20 keV.
[40]  oai:arXiv.org:astro-ph/0503621  [pdf] - 72003
Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
Comments: 16 pages, 13 figures. Submitted to Phys. Rev. D
Submitted: 2005-03-29
Liquid Xenon (LXe) is expected to be an excellent target and detector medium to search for dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Knowledge of LXe ionization and scintillation response to low energy nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important for determining the sensitivity of LXe direct detection experiments. Here we report on new measurements of the scintillation yield of Xe recoils with kinetic energy as low as 10 keV. The dependence of the scintillation yield on applied electric field was also measured in the range of 0 to 4 kV/cm. Results are in good agreement with recent theoretical predictions that take into account the effect of biexcitonic collisions in addition to the nuclear quenching effect.
[41]  oai:arXiv.org:physics/0502071  [pdf] - 119079
Performance of a Large Area Avalanche Photodiode in a Liquid Xenon Ionization and Scintillation Chamber
Comments: 13 pages, 8 figures
Submitted: 2005-02-14
Scintillation light produced in liquid xenon (LXe) by alpha particles, electrons and gamma-rays was detected with a large area avalanche photodiode (LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a function of applied electric field. We estimate the quantum efficiency of the LAAPD to be 45%. The best energy resolution from the light measurement at zero electric field is 7.5%(sigma) for 976 keV internal conversion electrons from Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector used for these measurements was also operated as a gridded ionization chamber to measure the charge yield. We confirm that using a LAAPD in LXe does not introduce impurities which inhibit the drifting of free electrons.
[42]  oai:arXiv.org:astro-ph/0407575  [pdf] - 66417
The XENON Dark Matter Search Experiment
Comments: 9 pages, 8 figures, appear in the Proceeding of 6th UCLA Symposium on Sources and Detection of Dark Matter and Dark Energy in the Universe
Submitted: 2004-07-28
The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest interaction cross section predicted by SUSY models. The TPCs are operated in dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to 16keV energy, via simultaneous detection of the ionization, through secondary scintillation in the gas, and primary scintillation in the liquid. Thedistinct ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or neutrons), and for electron recoils from background, iskey to the event-by-event discrimination capability of XENON. A dual phase xenon prototype has been realized and is currently being tested, along with otherprototypes dedicated to other measurements relevant to the XENON program. As part of the R&D phase, we will realize and move underground a first XENON module (XENON10) with at least 10 kg fiducial mass to measure the background rejection capability and to optimize the conditions for continuous and stable detector operation underground. We present some of the results from the ongoing R&D and summarize the expected performance of the 10 kg experiment, from MonteCarlo simulations. The main design features of the 100 kg detector unit(XENON100), with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will also be presented.
[43]  oai:arXiv.org:astro-ph/0212005  [pdf] - 53395
The LXeGRIT Compton Telescope Prototype: Current Status and Future Prospects
Comments: 13 pages, 11 figures, SPIE 2002 Proceedings, Conf. Vol. 4851 - 140; corrected references
Submitted: 2002-11-30, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel concept of Compton telescope, based on the complete 3-dimensional reconstruction of the sequence of interactions of individual gamma rays in one position sensitive detector. This balloon-borne telescope consists of an unshielded time projection chamber with an active volume of 400 cm$^2 \times 7$ cm filled with high purity liquid xenon. Four VUV PMTs detect the fast xenon scintillation light signal, providing the event trigger. 124 wires and 4 anodes detect the ionization signals, providing the event spatial coordinates and total energy. In the period 1999 -- 2001, LXeGRIT has been extensively tested both in the laboratory and at balloon altitude, and its response in the MeV region has been thoroughly characterized. Here we summarize some of the results on pre-flight calibration, event reconstruction techniques, and performance during a 27 hour balloon flight on October 4 -- 5. We further present briefly the on-going efforts directed to improve the performance of this prototype towards the requirements for a base module of a next-generation Compton telescope.
[44]  oai:arXiv.org:astro-ph/0211584  [pdf] - 53319
On the Background Rate in the LXeGRIT Instrument during the 2000 Balloon Flight
Comments: 13 pages, 12 figures, SPIE 2002 Proceedings, Conf. Vol. 4851 - 151; corrected references
Submitted: 2002-11-26, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel Compton telescope for MeV gamma-ray astrophysics based on a Liquid Xenon Time Projection Chamber (LXeTPC), sensitive in the energy band of 0.15-10 MeV. In this homogeneous, 3D position sensitive detector, gamma rays with at least two interactions in the sensitive volume of 2800 cm$^{3}$, are imaged as in a standard Compton telescope. Gamma-rays with a single interaction cannot be imaged and constitute a background which can be easily identified and rejected. Charged particles and localized beta-particles background is also easily suppressed based on the TPC localization capability with millimeter resolution. A measurement of the total gamma-ray background rate in near space conditions and the background rejection power of the LXeTPC was a primary goal of the LXeGRIT balloon flight program. We present here a preliminary analysis addressing this question, based on balloon flight data acquired during the Oct 4-5, 2000 LXeGRIT balloon flight from Ft. Sumner, NM. In this long duration (27 hr) balloon experiment, the LXeGRIT TPC was not surrounded by any gamma-ray or charged particle shield. Single site events and charged particles were mostly rejected on-line at the first and second trigger level. The remaining count rate of single-site \g-ray events, at an average atmospheric depth of 3.2 g cm$^{-2}$, is consistent with that expected from atmospheric and diffuse gamma-ray background, taking into account the instrument mass model and response.
[45]  oai:arXiv.org:astro-ph/0207670  [pdf] - 1591929
XENON: a 1 tonne Liquid Xenon Experiment for a Sensitive Dark Matter Search
Comments: 14 pages, 6 figures, submitted to proceedings of the International Workshop on Techniques and Applications of Xenon Detectors (Xenon01), ICRR, Univ. of Tokyo, Kashiwa, Japan, held December 2001 (World Scientific)
Submitted: 2002-07-31
XENON is a novel liquid xenon experiment concept for a sensitive dark matter search using a 1-tonne active target, distributed in an array of ten independent time projection chambers. The design relies on the simultaneous detection of ionization and scintillation signals in liquid xenon, with the goal of extracting as much information as possible on an event-by-event basis, while maintaining most of the target active. XENON is expected to have effective and redundant background identification and discrimination power, higher than 99.5%, and to achieve a very low threshold, on the order of 4 keV visible recoil energy. Based on this expectation and the 1-tonne mass of active xenon, we project a sensitivity of 0.0001 events/kg/day, after 3 yr operation in an appropriate underground location. The XENON experiment has been recently proposed to the National Science Foundation (NSF) for an initial development phase leading to the development of the 100 kg unit module.
[46]  oai:arXiv.org:astro-ph/0012398  [pdf] - 1232610
Preliminary Results from the 1999 Balloon Flight of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)
Comments: 16 pages, 15 figures; To appear in: X-Ray and Gamma-Ray Instrumentation for Astronomy XI, 2000; Proc. SPIE, vol. 4140; K.A. Flanagan & O.H. Siegmund, eds
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope employing a large volume liquid xenon time projection chamber (LXeTPC) as the central gamma-ray detector. It is designed to image gamma rays in the energy range of 200 keV to 20 MeV, with an angular resolution of about 3 degrees (1 sigma) at 2 MeV, within a field-of-view (FOV) of about 1 sr. The detector's energy and three-dimensional spatial resolution as measured during pre-flight calibration experiments, are $\Delta E_\mathrm{lxe}/E=8.8% : \sqrt{1\MeV /E}$ and < 1mm RMS, respectively. The detection efficiency for Compton events varies between 1.5% and 4% depending on energy and event selection. We describe the instrument as flown on May 7, 1999 and review its overall performance at balloon altitude. The launch occurred at 13:26:54 UT from Ft. Sumner, New Mexico and the flight was terminated about 9 hours later. The Crab was in the instrument FOV for a few hours. Analysis of these data is in progress.
[47]  oai:arXiv.org:astro-ph/0012395  [pdf] - 39984
Performance of the Light Trigger System in the Liquid Xenon Gamma-Ray Telescope LXeGRIT
Comments: Submitted to IEEE Trans. on Nuc. Sci., 7 pages, 11 figures
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber with charge and light readout. The energy and direction of an incident gamma-ray is reconstructed from the three-dimensional locations and energy deposits of individual interactions taking place in the homogeneous detector volume. While the charge signals provide energy information and X-Y positions, the fast xenon scintillation light signal is used to trigger the detector. The drift time measurement, referred to the time of the trigger signal, gives the Z-position with the known drift velocity. The light is detected by four UV-sensitive photomultiplier tubes (PMTs). The logical OR of the PMT signals triggers the data acquisition system with an efficiency which depends on the event energy and location, as well as on the discriminator thresholds used on the individual PMTs. Results from experiments with a tagged 22Na source give the spatial distribution of the light trigger efficiency for 511 keV gamma-rays. When averaged over the whole sensitive volume amd all PMTs, the trigger efficiency is 47% or 40% for two discriminator windows used during the LXeGRIT balloon flight of 1999. These values are strongly affected by the different sensitivity of each PMT. The corresponding average efficiency at 511 keV for the best of the four PMTs is in fact 63%, and approaches 100% for interactions taking place in a small volume right above the PMT.
[48]  oai:arXiv.org:astro-ph/0012276  [pdf] - 39865
An Upgraded Data Acquisition System for the Balloon-Borne Liquid Xenon Gamma-Ray Telescope LXeGRIT
Comments: Submitted to IEEE Trans. on Nuc. Sci., 6 pages, 3 figures
Submitted: 2000-12-12, last modified: 2000-12-14
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber (LXe-TPC) with charge and light readout. The first balloon flights in 1997 revealed limitations of the trigger electronics and the data acquisition (DAQ) system, leading to their upgrade. New electronics was developed to handle the xenon scintillation light trigger. The original processor module was replaced by a commercial VME processor. The telemetry rate was doubled to 2 x 500 kbps and onboard data storage on hard disks was implemented. Relying on a robust real-time operating system, the new DAQ software adopts an object oriented design to implement the diverse tasks of trigger handling, data selection, transmission, and storage, as well as DAQ control and monitor functions. The new systems performed well during two flights in Spring 1999 and Fall 2000. In the 2000 flight, the DAQ system was able to handle 300-350 triggers/s out of a total of about 650 Hz, including charged particles.
[49]  oai:arXiv.org:astro-ph/0012297  [pdf] - 1232606
Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)
Comments: To appear in: Hard X-Ray, Gamma-Ray and Neutron Detector Physics XI, 2000; Proc. SPIE, vol. 4140; K.A. Flanagan & O.H. Siegmund, eds
Submitted: 2000-12-13
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of 0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled with high purity LXe. Both ionization and scintillation light signals are detected to measure the energy deposits and the three spatial coordinates of individual \g -ray interactions within the sensitive volume. The TPC has been characterized with repeated measurements of its spectral and Compton imaging response to \g -rays from radioactive sources such as \na, \cs, \yt and Am-Be. The detector shows a linear response to \g -rays in the energy range 511 keV -4.4 MeV, with an energy resolution (FWHM) of $ \Delta E/E=8.8% \: \sqrt{1\MeV /E}$. Compton imaging of \yt \g -ray events with two detected interactions is consistent with an angular resolution of $\sim$ 3 degrees (RMS) at 1.8 MeV.
[50]  oai:arXiv.org:astro-ph/0012296  [pdf] - 1232605
Compton scattering sequence reconstruction algorithm for the liquid xenon gamma-ray imaging telescope (LXeGRIT)
Comments: To appear in: Hard X-Ray, Gamma-Ray, and Neutron Detector Physics II, 2000; Proc. SPIE, vol. 4141; R.B. James & R.C. Schirato, eds
Submitted: 2000-12-13
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main detector is a time projection chamber filled with high purity liquid xenon (LXeTPC), in which the three-dimensional location and energy deposit of individual \g -ray interactions are accurately measured in one homogeneous volume. To determine the \g -ray initial direction (Compton imaging), as well as to reject background, the correct sequence of interactions has to be determined. Here we report the development and optimization of an algorithm to reconstruct the Compton scattering sequence and show its performance on Monte Carlo events and LXeGRIT data.