Normalized to: Giboni, K.
[1]
oai:arXiv.org:1708.05825 [pdf] - 1598121
Exploring the dark matter inelastic frontier with 79.6 days of PandaX-II
data
Collaboration, PandaX-II;
:;
Chen, Xun;
Abdukerim, Abdusalam;
Chen, Wei;
Chen, Yunhua;
Cui, Xiangyi;
Fang, Deqing;
Fu, Changbo;
Giboni, Karl;
Giuliani, Franco;
Guo, Xuyuan;
Guo, Zhifan;
Han, Ke;
He, Shengming;
Huang, Xingtao;
Ji, Xiangdong;
Ju, Yonglin;
Li, Shaoli;
Lin, Heng;
Liu, Huaxuan;
Liu, Jianglai;
Ma, Yugang;
Mao, Yajun;
Ning, Jinhua;
Ren, Xiangxiang;
Shi, Fang;
Tan, Andi;
Wang, Cheng;
Wang, Hongwei;
Wang, Meng;
Wang, Qiuhong;
Wang, Siguang;
Wang, Xiuli;
Wang, Xuming;
Wu, Qingyu;
Wu, Shiyong;
Xiao, Mengjiao;
Xie, Pengwei;
Yan, Binbin;
Yang, Yong;
Yue, Jianfeng;
Zhang, Dan;
Zhang, Hongguang;
Zhang, Tao;
Zhao, Li;
Zhou, Jifang;
Zhou, Ning;
Zhou, Xiaopeng
Submitted: 2017-08-19, last modified: 2017-10-03
We report here the results of searching for inelastic scattering of dark
matter (initial and final state dark matter particles differ by a small mass
splitting) with nucleon with the first 79.6-day of PandaX-II data (Run 9). We
set the upper limits for the spin independent WIMP-nucleon scattering cross
section up to a mass splitting of 300 keV/c$^2$ at two benchmark dark matter
masses of 1 and 10 TeV/c$^2$.
[2]
oai:arXiv.org:1707.07921 [pdf] - 1586345
Limits on Axion Couplings from the first 80-day data of PandaX-II
Experiment
Fu, Changbo;
Zhou, Xiaopeng;
Chen, Xun;
Chen, Yunhua;
Cui, Xiangyi;
Fang, Deqing;
Giboni, Karl;
Giuliani, Franco;
Han, Ke;
Huang, Xingtao;
Ji, Xiangdong;
Ju, Yonglin;
Lei, Siao;
Li, Shaoli;
Liu, Huaxuan;
Liu, Jianglai;
Ma, Yugang;
Mao, Yajun;
Ren, Xiangxiang;
Tan, Andi;
Wang, Hongwei;
Wang, Jimin;
Wang, Meng;
Wang, Qiuhong;
Wang, Siguang;
Wang, Xuming;
Wang, Zhou;
Wu, Shiyong;
Xiao, Mengjiao;
Xie, Pengwei;
Yan, Binbin;
Yang, Yong;
Yue, Jianfeng;
Zhang, Hongguang;
Zhang, Tao;
Zhao, Li;
Zhou, Ning
Submitted: 2017-07-25, last modified: 2017-10-02
We report new searches for the solar axions and galactic axion-like dark
matter particles, using the first low-background data from PandaX-II experiment
at China Jinping Underground Laboratory, corresponding to a total exposure of
about $2.7\times 10^4$ kg$\cdot$day. No solar axion or galactic axion-like dark
matter particle candidate has been identified. The upper limit on the
axion-electron coupling ($g_{Ae}$) from the solar flux is found to be about
$4.35 \times 10^{-12}$ in mass range from $10^{-5}$ to 1 keV/$c^2$ with 90\%
confidence level, similar to the recent LUX result. We also report a new best
limit from the $^{57}$Fe de-excitation. On the other hand, the upper limit from
the galactic axions is on the order of $10^{-13}$ in the mass range from 1
keV/$c^2$ to 10 keV/$c^2$ with 90\% confidence level, slightly improved
compared with the LUX.
[3]
oai:arXiv.org:1708.06917 [pdf] - 1587379
Dark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment
Collaboration, PandaX-II;
:;
Cui, Xiangyi;
Abdukerim, Abdusalam;
Chen, Wei;
Chen, Xun;
Chen, Yunhua;
Dong, Binbin;
Fang, Deqing;
Fu, Changbo;
Giboni, Karl;
Giuliani, Franco;
Gu, Linhui;
Gu, Yikun;
Guo, Xuyuan;
Guo, Zhifan;
Han, Ke;
He, Changda;
Huang, Di;
He, Shengming;
Huang, Xingtao;
Huang, Zhou;
Ji, Xiangdong;
Ju, Yonglin;
Li, Shaoli;
Li, Yao;
Lin, Heng;
Liu, Huaxuan;
Liu, Jianglai;
Ma, Yugang;
Mao, Yajun;
Ni, Kaixiang;
Ning, Jinhua;
Ren, Xiangxiang;
Shi, Fang;
Tan, Andi;
Wang, Cheng;
Wang, Hongwei;
Wang, Meng;
Wang, Qiuhong;
Wang, Siguang;
Wang, Xiuli;
Wang, Xuming;
Wu, Qinyu;
Wu, Shiyong;
Xiao, Mengjiao;
Xie, Pengwei;
Yan, Binbin;
Yang, Yong;
Yue, Jianfeng;
Zhang, Dan;
Zhang, Hongguang;
Zhang, Tao;
Zhang, Tianqi;
Zhao, Li;
Zhou, Jifang;
Zhou, Ning;
Zhou, Xiaopeng
Submitted: 2017-08-23, last modified: 2017-09-21
We report a new search of weakly interacting massive particles (WIMPs) using
the combined low background data sets in 2016 and 2017 from the PandaX-II
experiment in China. The latest data set contains a new exposure of 77.1 live
day, with the background reduced to a level of 0.8$\times10^{-3}$ evt/kg/day,
improved by a factor of 2.5 in comparison to the previous run in 2016. No
excess events were found above the expected background. With a total exposure
of 5.4$\times10^4$ kg day, the most stringent upper limit on spin-independent
WIMP-nucleon cross section was set for a WIMP with mass larger than 100
GeV/c$^2$, with the lowest exclusion at 8.6$\times10^{-47}$ cm$^2$ at 40
GeV/c$^2$.
[4]
oai:arXiv.org:1708.07051 [pdf] - 1697916
The XENON1T Dark Matter Experiment
XENON Collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Antunes, B.;
Arneodo, F.;
Balata, M.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Chiarini, A.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Corrieri, R.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Disdier, J. -M.;
Doets, M.;
Duchovni, E.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Florin, D.;
Front, D.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Huhmann, C.;
Itay, R.;
James, A.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Maier, R.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orlandi, D.;
Othegraven, R.;
Pakarha, P.;
Parlati, S.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Saldahna, R.;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stern, M.;
Stein, A.;
Tatananni, D.;
Tatananni, L.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Walet, R.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.
Submitted: 2017-08-23
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is
the first WIMP dark matter detector operating with a liquid xenon target mass
above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute
the active target of the dual-phase time projection chamber. The scintillation
and ionization signals from particle interactions are detected with
low-background photomultipliers. This article describes the XENON1T instrument
and its subsystems as well as strategies to achieve an unprecedented low
background level. First results on the detector response and the performance of
the subsystems are also presented.
[5]
oai:arXiv.org:1611.06553 [pdf] - 1532729
Spin-Dependent Weakly-Interacting-Massive-Particle--Nucleon Cross
Section Limits from First Data of PandaX-II Experiment
Fu, Changbo;
Cui, Xiangyi;
Zhou, Xiaopeng;
Chen, Xun;
Chen, Yunhua;
Fang, Deqing;
Giboni, Karl;
Giuliani, Franco;
Han, Ke;
Huang, Xingtao;
Ji, Xiangdong;
Ju, Yonglin;
Lei, Siao;
Li, Shaoli;
Liu, Huaxuan;
Liu, Jianglai;
Ma, Yugang;
Mao, Yajun;
Ren, Xiangxiang;
Tan, Andi;
Wang, Hongwei;
Wang, Jiming;
Wang, Meng;
Wang, Qiuhong;
Wang, Siguang;
Wang, Xuming;
Wang, Zhou;
Wu, Shiyong;
Xiao, Mengjiao;
Xie, Pengwei;
Yan, Binbin;
Yang, Yong;
Yue, Jianfeng;
Zhang, Hongguang;
Zhang, Tao;
Zhao, Li;
Zhou, Ning
Submitted: 2016-11-20, last modified: 2017-02-14
New constraints are presented on the spin-dependent WIMP-nucleon interaction
from the PandaX-II experiment, using a data set corresponding to a total
exposure of 3.3$\times10^4$ kg-days. Assuming a standard axial-vector
spin-dependent WIMP interaction with $^{129}$Xe and $^{131}$Xe nuclei, the most
stringent upper limits on WIMP-neutron cross sections for WIMPs with masses
above 10 GeV/c$^{2}$ are set in all dark matter direct detection experiments.
The minimum upper limit of $4.1\times 10^{-41}$ cm$^2$ at 90\% confidence level
is obtained for a WIMP mass of 40 GeV/c$^{2}$. This represents more than a
factor of two improvement on the best available limits at this and higher
masses. These improved cross-section limits provide more stringent constraints
on the effective WIMP-proton and WIMP-neutron couplings.
[6]
oai:arXiv.org:1505.00771 [pdf] - 1280844
Low-mass dark matter search results from full exposure of PandaX-I
experiment
PandaX Collaboration;
Xiao, Xiang;
Chen, Xun;
Tan, Andi;
Chen, Yunhua;
Cui, Xiangyi;
Fang, Deqing;
Fu, Changbo;
Giboni, Karl L.;
Gong, Haowei;
Guo, Guodong;
He, Ming;
Ji, Xiangdong;
Ju, Yonglin;
Lei, Siao;
Li, Shaoli;
Lin, Qing;
Liu, Huaxuan;
Liu, Jianglai;
Liu, Xiang;
Lorenzon, Wolfgang;
Ma, Yugang;
Mao, Yajun;
Ni, Kaixuan;
Pushkin, Kirill;
Ren, Xiangxiang;
Schubnell, Michael;
Shen, Manbin;
Shi, Yuji;
Stephenson, Scott;
Wang, Hongwei;
Wang, Jiming;
Wang, Meng;
Wang, Siguang;
Wang, Xuming;
Wang, Zhou;
Wu, Shiyong;
Xiao, Mengjiao;
Xie, Pengwei;
Yan, Binbin;
You, Yinghui;
Zeng, Xionghui;
Zhang, Tao;
Zhao, Li;
Zhou, Xiaopeng;
Zhu, Zhonghua
Submitted: 2015-05-04, last modified: 2015-08-20
We report the results of a weakly-interacting massive particle (WIMP) dark
matter search using the full 80.1\;live-day exposure of the first stage of the
PandaX experiment (PandaX-I) located in the China Jin-Ping Underground
Laboratory. The PandaX-I detector has been optimized for detecting low-mass
WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid
xenon target mass of 54.0\,kg, no significant excess event were found above the
expected background. A profile likelihood analysis confirms our earlier finding
that the PandaX-I data disfavor all positive low-mass WIMP signals reported in
the literature under standard assumptions. A stringent bound on the low mass
WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon
detectors can be competitive for low-mass WIMP searches.
[7]
oai:arXiv.org:1408.5114 [pdf] - 863825
First dark matter search results from the PandaX-I experiment
PandaX Collaboration;
Xiao, Mengjiao;
Xiao, Xiang;
Zhao, Li;
Cao, Xiguang;
Chen, Xun;
Chen, Yunhua;
Cui, Xiangyi;
Fang, Deqing;
Fu, Changbo;
Giboni, Karl L.;
Gong, Haowei;
Guo, Guodong;
Hu, Jie;
Huang, Xingtao;
Ji, Xiangdong;
Ju, Yonglin;
Lei, Siao;
Li, Shaoli;
Lin, Qing;
Liu, Huaxuan;
Liu, Jianglai;
Liu, Xiang;
Lorenzon, Wolfgang;
Ma, Yugang;
Mao, Yajun;
Ni, Kaixuan;
Pushkin, Kirill;
Ren, Xiangxiang;
Schubnell, Michael;
Shen, Manbing;
Stephenson, Scott;
Tan, Andi;
Tarle, Greg;
Wang, Hongwei;
Wang, Jimin;
Wang, Meng;
Wang, Xuming;
Wang, Zhou;
Wei, Yuehuan;
Wu, Shiyong;
Xie, Pengwei;
You, Yinghui;
Zeng, Xionghui;
Zhang, Hua;
Zhang, Tao;
Zhu, Zhonghua
Submitted: 2014-08-21, last modified: 2014-09-04
We report on the first dark-matter (DM) search results from PandaX-I, a low
threshold dual-phase xenon experiment operating at the China Jinping
Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of
exposure, no DM particle candidate event was found. This result sets a
stringent limit for low-mass DM particles and disfavors the interpretation of
previously-reported positive experimental results. The minimum upper limit,
$3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar
DM-particle-nucleon scattering cross section is obtained at a DM-particle mass
of 49\,GeV/c$^2$ at 90\% confidence level.
[8]
oai:arXiv.org:1311.1088 [pdf] - 783783
Observation and applications of single-electron charge signals in the
XENON100 experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-11-05, last modified: 2014-01-28
The XENON100 dark matter experiment uses liquid xenon in a time projection
chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of
dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we
report the observation of single-electron charge signals which are not related
to WIMP interactions. These signals, which show the excellent sensitivity of
the detector to small charge signals, are explained as being due to the
photoionization of impurities in the liquid xenon and of the metal components
inside the TPC. They are used as a unique calibration source to characterize
the detector. We explain how we can infer crucial parameters for the XENON100
experiment: the secondary-scintillation gain, the extraction yield from the
liquid to the gas phase and the electron drift velocity.
[9]
oai:arXiv.org:1207.3458 [pdf] - 1693882
Analysis of the XENON100 Dark Matter Search Data
The XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D. B.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-07-14, last modified: 2013-10-14
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso,
aims at the direct detection of dark matter in the form of weakly interacting
massive particles (WIMPs), based on their interactions with xenon nuclei in an
ultra low background dual-phase time projection chamber. This paper describes
the general methods developed for the analysis of the XENON100 data. These
methods have been used in the 100.9 and 224.6 live days science runs from which
results on spin-independent elastic, spin-dependent elastic and inelastic
WIMP-nucleon cross-sections have already been reported.
[10]
oai:arXiv.org:1306.2303 [pdf] - 1171929
The neutron background of the XENON100 dark matter experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
ScottoLavina, L.;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-06-10, last modified: 2013-09-02
The XENON100 experiment, installed underground at the Laboratori Nazionali
del Gran Sasso (LNGS), aims to directly detect dark matter in the form of
Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off
xenon nuclei. This paper presents a study on the nuclear recoil background of
the experiment, taking into account neutron backgrounds from ($\alpha$,n) and
spontaneous fission reactions due to natural radioactivity in the detector and
shield materials, as well as muon-induced neutrons. Based on Monte Carlo
simulations and using measured radioactive contaminations of all detector
components, we predict the nuclear recoil backgrounds for the WIMP search
results published by the XENON100 experiment in 2011 and 2012,
0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively,
and conclude that they do not limit the sensitivity of the experiment.
[11]
oai:arXiv.org:1304.1427 [pdf] - 705114
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
The XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.;
Schuhmacher, H.;
Wiegel, B.
Submitted: 2013-04-04, last modified: 2013-07-18
Results from the nuclear recoil calibration of the XENON100 dark matter
detector installed underground at the Laboratori Nazionali del Gran Sasso
(LNGS), Italy are presented. Data from measurements with an external 241AmBe
neutron source are compared with a detailed Monte Carlo simulation which is
used to extract the energy dependent charge-yield Qy and relative scintillation
efficiency Leff. A very good level of absolute spectral matching is achieved in
both observable signal channels - scintillation S1 and ionization S2 - along
with agreement in the 2-dimensional particle discrimination space. The results
confirm the validity of the derived signal acceptance in earlier reported dark
matter searches of the XENON100 experiment.
[12]
oai:arXiv.org:1104.3088 [pdf] - 661239
A search for light dark matter in XENON10 data
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with
the XENON10 detector. The event trigger was sensitive to a single electron,
with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear
recoil energy. Considering spin-independent dark matter-nucleon scattering, we
exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle
mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic
dark matter interpretations of excess low-energy events observed by CoGeNT and
CRESST-II, as well as the DAMA annual modulation signal.
[13]
oai:arXiv.org:1207.5988 [pdf] - 642231
Dark Matter Results from 225 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kettling, H.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-07-25, last modified: 2013-03-20
We report on a search for particle dark matter with the XENON100 experiment,
operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during
2011 and 2012. XENON100 features an ultra-low electromagnetic background of
(5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of
interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded
no evidence for dark matter interactions. The two candidate events observed in
the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent
with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood
analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on
the spin-independent elastic WIMP-nucleon scattering cross section for WIMP
masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2
and 90% confidence level.
[14]
oai:arXiv.org:1101.3866 [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso
(LNGS), aims to directly detect dark matter in the form of Weakly Interacting
Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We
present a comprehensive study of the predicted electronic recoil background
coming from radioactive decays inside the detector and shield materials, and
intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a
detailed geometry together with the measured radioactivity of all detector
components, we predict an electronic recoil background in the WIMP-search
energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2
events/(kg-day-keV), consistent with the experiment's design goal. The
predicted background spectrum is in very good agreement with the data taken
during the commissioning of the detector, in Fall 2009.
[15]
oai:arXiv.org:1301.6620 [pdf] - 704634
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days
of XENON100 data
XENON100 collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-01-28, last modified: 2013-01-29
We present new experimental constraints on the elastic, spin-dependent
WIMP-nucleon cross section using recent data from the XENON100 experiment,
operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of
224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no
excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe
nuclei. This leads to the most stringent upper limits on WIMP-neutron cross
sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x
10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
[16]
oai:arXiv.org:1211.0836 [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G. M.;
Budnik, R.;
Calloch, M. Le;
Cardoso, J. M.;
Chen, W. -T.;
Choi, B.;
Contreras, H.;
Cussonneau, J. -P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Giboni, K. -L.;
Goetzke, L.;
Grignon, C.;
Gross, E.;
Hampel, W.;
McKinsey, D. N.;
Kish, A.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Manzur, A.;
Undagoitia, T. Marrodán;
Massoli, F. V.;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Patricio, J. V.;
Persiani, R.;
Plante, G.;
Priel, N.;
Ribeiro, A. C. C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso (LNGS) in Italy, was designed to search for evidence of dark matter
interactions inside a volume of liquid xenon using a dual-phase time projection
chamber. This paper describes the Slow Control System (SCS) of the experiment
with emphasis on the distributed architecture as well as on its modular and
expandable nature. The system software was designed according to the rules of
Object-Oriented Programming and coded in Java, thus promoting code reusability
and maximum flexibility during commissioning of the experiment. The SCS has
been continuously monitoring the XENON100 detector since mid 2008, remotely
recording hundreds of parameters on a few dozen instruments in real time, and
setting emergency alarms for the most important variables.
[17]
oai:arXiv.org:1209.3658 [pdf] - 673149
Measurement of the Scintillation Yield of Low-Energy Electrons in Liquid
Xenon
Aprile, E.;
Budnik, R.;
Choi, B.;
Contreras, H. A.;
Giboni, K. -L.;
Goetzke, L. W.;
Koglin, J. E.;
Lang, R. F.;
Lim, K. E.;
Fernandez, A. J. Melgarejo;
Persiani, R.;
Plante, G.;
Rizzo, A.
Submitted: 2012-09-17
We have measured the energy dependence of the liquid xenon (LXe)
scintillation yield of electrons with energy between 2.1 and 120.2keV, using
the Compton coincidence technique. A LXe scintillation detector with a very
high light detection efficiency was irradiated with 137Cs {\gamma} rays and the
energy of the Compton-scattered {\gamma} rays was measured with a high-purity
germanium (HPGe) detector placed at different scattering angles. The excellent
energy resolution of the HPGe detector allows the selection of events with
Compton electrons of known energy in the LXe detector. We find that the
scintillation yield initially increases as the electron energy decreases from
120 keV to about 60keV but then decreases by about 30% from 60keV to 2keV. The
measured scintillation yield was also measured with conversion electrons from
the 32.1 keV and 9.4 keV transitions of the 83mKr isomer, used as an internal
calibration source. We find that the scintillation yield of the 32.1 keV
transition is compatible with that obtained from the Compton coincidence
measurement. On the other hand, the yield for the 9.4keV transition is much
higher than that measured for a Compton electron of the same energy. We
interpret the enhancement in the scintillation yield as due to the enhanced
recombination rate in the presence of Xe ions left from the 32.1 keV
transition, which precedes the 9.4 keV one by 220 ns, on average.
[18]
oai:arXiv.org:1208.5762 [pdf] - 555466
Comment on "On the subtleties of searching for dark matter with liquid
xenon detectors"
The XENON Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-08-28
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that
XENON100's upper limits on spin-independent WIMP-nucleon cross sections for
WIMP masses below 10 GeV "may be understated by one order of magnitude or
more". Having performed a similar, though more detailed analysis prior to the
submission of our new result (arXiv:1207.5988), we do not confirm these
findings. We point out the rationale for not considering the described effect
in our final analysis and list several potential problems with his study.
[19]
oai:arXiv.org:1207.5432 [pdf] - 1125033
Measurement of the Quantum Efficiency of Hamamatsu R8520
Photomultipliers at Liquid Xenon Temperature
Aprile, E.;
Beck, M.;
Bokeloh, K.;
Budnik, R.;
Choi, B.;
Contreras, H. A.;
Giboni, K. -L.;
Goetzke, L. W.;
Lang, R. F.;
Lim, K. E.;
Fernandez, A. J. Melgarejo;
Plante, G.;
Rizzo, A.;
Shagin, P.;
Weinheimer, C.
Submitted: 2012-07-23
Vacuum ultraviolet light sensitive photomultiplier tubes directly coupled to
liquid xenon are being used to efficiently detect the 178 nm scintillation
light in a variety of liquid xenon based particle detectors. Good knowledge of
the performance of these photomultipliers under cryogenic conditions is needed
to properly characterize these detectors. Here, we report on measurements of
the quantum efficiency of Hamamatsu R8520 photomultipliers, used in the XENON
Dark Matter Experiments. The quantum efficiency measurements at room
temperature agree with the values provided by Hamamatsu. At low temperatures,
between 160K and 170K, the quantum efficiency increases by $\sim5-11$% relative
to the room temperature values.
[20]
oai:arXiv.org:1207.5100 [pdf] - 1125005
The Cryogenic System for the Panda-X Dark Matter Search Experiment
Submitted: 2012-07-21
Panda-X is a liquid xenon dual-phase detector for the Dark Matter Search. The
first modestly-sized module will soon be installed in the China JinPing Deep
Underground Laboratory in Sichuan province, P.R. China. The cryogenics system
is designed to handle much larger detectors, even the final version in the ton
scale. Special attention has been paid to the reliability, serviceability, and
adaptability to the requirements of a growing experiment. The system is cooled
by a single Iwatani PC150 Pulse Tube Refrigerator. After subtracting all
thermal losses, the remaining cooling power is still 82W. The fill speed was 9
SLPM, but could be boosted by LN2 assisted cooling to 40 SLPM. For the
continuous recirculation and purification through a hot getter, a heat
exchanger was employed to reduce the required cooling power. The recirculation
speed is limited to 35 SLPM by the gas pump. At this speed, recirculation only
adds 18.5 W to the heat load of the system, corresponding to a 95.2 %
efficiency of the heat exchanger.
[21]
oai:arXiv.org:1107.2155 [pdf] - 474250
The XENON100 Dark Matter Experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. L.;
Kish, A.;
Lam, C. W.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Tziaferi, E.;
Wang, H.;
Yamashita, M.
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time
projection chamber (TPC) to search for Xe nuclear recoils resulting from the
scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this
paper we present a detailed description of the detector design and present
performance results, as established during the commissioning phase and during
the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe
veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating
inside the liquid or in Xe gas. The LXe target and veto are contained in a
low-radioactivity stainless steel vessel, embedded in a passive radiation
shield. The experiment is installed underground at the Laboratori Nazionali del
Gran Sasso (LNGS), Italy and has recently published results from a 100
live-days dark matter search. The ultimate design goal of XENON100 is to
achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of
\sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[22]
oai:arXiv.org:1109.4270 [pdf] - 427699
Limits on the release of Rb isotopes from a zeolite based 83mKr
calibration source for the XENON project
Hannen, V.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Beck, M.;
Bokeloh, K.;
Ferella, A. D.;
Giboni, K.;
Lang, R. F.;
Lebeda, O.;
Ortjohann, H. -W.;
Schumann, M.;
Spalek, A.;
Venos, D.;
Weinheimer, C.
Submitted: 2011-09-20, last modified: 2011-10-06
The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source
for a liquid noble gas dark matter experiment like the XENON project. However,
the risk of contamination of the detector with traces of the much longer lived
mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the
release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has
been investigated. To do so, a cryogenic trap has been connected to the source
for about 10 days, after which it was removed and probed for the strongest 83Rb
gamma-rays with an ultra-sensitive Germanium detector. No signal has been
found. The corresponding upper limit on the released 83Rb activity means that
the investigated type of source can be used in the XENON project and similar
low-background experiments as 83mKr generator without a significant risk of
contaminating the detector. The measurements also allow to set upper limits on
the possible release of the isotopes 84Rb and 86Rb, traces of which were
created alongside the production of 83Rb at the Rez cyclotron.
[23]
oai:arXiv.org:1104.3121 [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100
Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9
live-days of data, taken from January to June 2010. Events in a 48kg fiducial
volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A
total of three events have been found in the predefined signal region,
compatible with the background prediction of (1.8 \pm 0.6) events. Based on
this analysis we present limits on the WIMP-nucleon cross section for inelastic
dark matter. With the present data we are able to rule out the explanation for
the observed DAMA/LIBRA modulation as being due to inelastic dark matter
scattering off iodine at a 90% confidence level.
[24]
oai:arXiv.org:1104.2549 [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.
[25]
oai:arXiv.org:1103.0303 [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to
distinguish a dominant background from the expected feeble signals, based on
some measured discrimination parameter. We develop a statistical model for such
experiments using the Profile Likelihood ratio as a test statistic in a
frequentist approach. We take data from calibrations as control measurements
for signal and background, and the method allows the inclusion of data from
Monte Carlo simulations. Systematic detector uncertainties, such as
uncertainties in the energy scale, as well as astrophysical uncertainties, are
included in the model. The statistical model can be used to either set an
exclusion limit or to make a discovery claim, and the results are derived with
a proper treatment of statistical and systematic uncertainties. We apply the
model to the first data release of the XENON100 experiment, which allows to
extract additional information from the data, and place stronger limits on the
spin-independent elastic WIMP-nucleon scattering cross-section. In particular,
we derive a single limit, including all relevant systematic uncertainties, with
a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[26]
oai:arXiv.org:1104.2587 [pdf] - 669518
New Measurement of the Scintillation Efficiency of Low-Energy Nuclear
Recoils in Liquid Xenon
Submitted: 2011-04-13
Particle detectors that use liquid xenon (LXe) as detection medium are among
the leading technologies in the search for dark matter weakly interacting
massive particles (WIMPs). A key enabling element has been the low-energy
detection threshold for recoiling nuclei produced by the interaction of WIMPs
in LXe targets. In these detectors, the nuclear recoil energy scale is based on
the LXe scintillation signal and thus requires knowledge of the relative
scintillation efficiency of nuclear recoils, Leff. The uncertainty in Leff at
low energies is the largest systematic uncertainty in the reported results from
LXe WIMP searches at low masses. In the context of the XENON Dark Matter
project, a new LXe scintillation detector has been designed and built
specifically for the measurement of Leff at low energies, with an emphasis on
maximizing the scintillation light detection efficiency to obtain the lowest
possible energy threshold. We report new measurements of Leff at low energies
performed with this detector. Our results suggest a Leff which slowly decreases
with energy, from 0.144 +/- 0.009 at 15 keV down to 0.088 +0.014 -0.015 at 3
keV.
[27]
oai:arXiv.org:1005.0380 [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
The XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D. B.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Hugenberg, K.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weinheimer, C.
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62
kg of liquid xenon in an ultra-low background dual-phase time projection
chamber. In this letter, we present first dark matter results from the analysis
of 11.17 live days of non-blind data, acquired in October and November 2009. In
the selected fiducial target of 40 kg, and within the pre-defined signal
region, we observe no events and hence exclude spin-independent WIMP-nucleon
elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs
at 90% confidence level. Below 20 GeV/c^2, this result constrains the
interpretation of the CoGeNT and DAMA signals as being due to spin-independent,
elastic, light mass WIMP interactions.
[28]
oai:arXiv.org:0910.3698 [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically
from detector target nuclei could explain the apparent incompatibility of the
DAMA modulation signal (interpreted as evidence for particle dark matter) with
the null results from CDMS-II and XENON10. Among the predictions of
inelastically interacting dark matter are a suppression of low-energy events,
and a population of nuclear recoil events at higher nuclear recoil equivalent
energies. This is in stark contrast to the well-known expectation of a falling
exponential spectrum for the case of elastic interactions. We present a new
analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV
nuclear recoil equivalent energy. Our results exclude a significant region of
previously allowed parameter space in the model of inelastically interacting
dark matter. In particular, it is found that dark matter particle masses
$m_{\chi}\gtrsim150$ GeV are disfavored.
[29]
oai:arXiv.org:1011.6439 [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Sorensen, P.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark
matter search data can be lowered to ~1 keV, by using only the ionization
signal. In other words, we make no requirement that a valid event contain a
primary scintillation signal. We therefore relinquish incident particle type
discrimination, which is based on the ratio of ionization to scintillation in
liquid xenon. This method compromises the detector's ability to precisely
determine the z coordinate of a particle interaction. However, we show for the
first time that it is possible to discriminate bulk events from surface events
based solely on the ionization signal.
[30]
oai:arXiv.org:0810.0274 [pdf] - 166670
New Measurement of the Relative Scintillation Efficiency of Xenon
Nuclear Recoils Below 10 keV
Aprile, E.;
Baudis, L.;
Choi, B.;
Giboni, K. L.;
Lim, K. E.;
Manalaysay, A.;
Monzani, M. E.;
Plante, G.;
Santorelli, R.;
Yamashita, M.
Submitted: 2008-10-01, last modified: 2010-05-16
Liquid xenon is an important detection medium in direct dark matter
experiments, which search for low-energy nuclear recoils produced by the
elastic scattering of WIMPs with quarks. The two existing measurements of the
relative scintillation efficiency of nuclear recoils below 20 keV lead to
inconsistent extrapolations at lower energies. This results in a different
energy scale and thus sensitivity reach of liquid xenon dark matter detectors.
We report a new measurement of the relative scintillation efficiency below 10
keV performed with a liquid xenon scintillation detector, optimized for maximum
light collection. Greater than 95% of the interior surface of this detector was
instrumented with photomultiplier tubes, giving a scintillation yield of 19.6
photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the
relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying
constant around this value up to 10 keV. For higher energy recoils we measure a
value around 20%, consistent with previously reported data. In light of this
new measurement, the XENON10 experiment's results on spin-independent
WIMP-nucleon cross section, which were calculated assuming a constant 0.19
relative scintillation efficiency, change from $8.8\times10^{-44}$ cm$^2$ to
$9.9\times10^{-44}$ cm$^2$ for WIMPs of mass 100 GeV/c$^2$, and from
$4.4\times10^{-44}$ cm$^2$ to $5.6\times10^{-44}$ cm$^2$ for WIMPs of mass 30
GeV/c$^2$.
[31]
oai:arXiv.org:1001.2834 [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Aprile, E.;
Angle, J.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Orlandi, D.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Tatananni, E.;
Winant, C.;
Yamashita, M.
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed
within the XENON dark matter search program. The TPC, with an active liquid
xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground
laboratory (LNGS) in Italy, and operated for more than one year, with excellent
stability and performance. Results from a dark matter search with XENON10 have
been published elsewhere. In this paper, we summarize the design and
performance of the detector and its subsystems, based on calibration data using
sources of gamma-rays and neutrons as well as background and Monte Carlo
simulations data. The results on the detector's energy threshold, energy and
position resolution, and overall efficiency show a performance that exceeds
design specifications, in view of the very low energy threshold achieved (<10
keVr) and the excellent energy resolution achieved by combining the ionization
and scintillation signals, detected simultaneously.
[32]
oai:arXiv.org:0807.0459 [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear
recoils
Sorensen, P.;
Manzur, A.;
Dahl, C. E.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It
is a dual phase (liquid/gas) xenon time-projection chamber with 3D position
imaging. Particle interactions generate a primary scintillation signal (S1) and
ionization signal (S2), which are both functions of the deposited recoil energy
and the incident particle type. We present a new precision measurement of the
relative scintillation yield \leff and the absolute ionization yield Q_y, for
nuclear recoils in xenon. A dark matter particle is expected to deposit energy
by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for
establishing the energy threshold of the experiment; this in turn determines
the sensitivity to particle dark matter. Our \leff measurement is in agreement
with recent theoretical predictions above 15 keV nuclear recoil energy, and the
energy threshold of the measurement is 4 keV. A knowledge of the ionization
yield \Qy is necessary to establish the trigger threshold of the experiment.
The ionization yield \Qy is measured in two ways, both in agreement with
previous measurements and with a factor of 10 lower energy threshold.
[33]
oai:arXiv.org:0805.2939 [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10
experiment
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive
particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter
in our Universe. We report new results for spin-dependent WIMP-nucleon
interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the
Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a
WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously
unexplored regions in the theoretically allowed parameter space for
neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range
of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its
density and distribution in the galactic halo.
[34]
oai:arXiv.org:0706.0039 [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso
National Laboratory
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg
xenon dual phase time projection chamber (XeTPC) to search for dark matter
weakly interacting massive particles (WIMPs). The detector measures
simultaneously the scintillation and the ionization produced by radiation in
pure liquid xenon, to discriminate signal from background down to 4.5 keV
nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired
between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4
kg, excludes previously unexplored parameter space, setting a new 90% C.L.
upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x
10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a
WIMP mass of 30 GeV/c^2. This result further constrains predictions of
supersymmetric models.
[35]
oai:arXiv.org:0704.1118 [pdf] - 231
Observation of Anti-correlation between Scintillation and Ionization for
MeV Gamma-Rays in Liquid Xenon
Submitted: 2007-04-09
A strong anti-correlation between ionization and scintillation signals
produced by MeV gamma-rays in liquid xenon has been measured and used to
improve the energy resolution by combining the two signals. The improvement is
explained by reduced electron-ion recombination fluctuations of the combined
signal compared to fluctuations of the individual signals. Simultaneous
measurements of ionization and scintillation signals were carried out with
Cs-137, Na-22 and Co-60 gamma rays, as a function of electric field in the
liquid. A resolution of 1.7%(sigma) at 662 keV was measured at 1 kV/cm,
significantly better than the resolution from either scintillation or
ionization alone. A detailed analysis indicates that further improvement to
less than 1%(sigma) is possible with higher light collection efficiency and
lower electronic noise.
[36]
oai:arXiv.org:physics/0702078 [pdf] - 119207
A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during
the 2000 Balloon Flight Campaign
Submitted: 2007-02-09
LXeGRIT - Liquid Xenon Gamma-Ray Imaging Telescope - is the first prototype
of a Compton telescope for \MeV \g-ray astrophysics based on a LXe time
projection chamber. One of the most relevant figures of merit for a Compton
telescope is the detection efficiency for \g-rays, which depends on diverse
contributions such as detector geometry and passive materials, trigger
efficiency, dead time, etc. A detailed study of the efficiency of the LXeGRIT
instrument, based both on laboratory measurements and Monte Carlo simulations,
is presented in this paper.
[37]
oai:arXiv.org:astro-ph/0609714 [pdf] - 85306
3D Position Sensitive XeTPC for Dark Matter Search
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Coelho, L.;
Dahl, E.;
DeViveiros, L.;
Ferella, A.;
Fernandes, L.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. -L.;
Gomez, R.;
Hasty, R.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santos, J.;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Winant, C.;
Yamashita, M.
Submitted: 2006-09-26
The technique to realize 3D position sensitivity in a two-phase xenon time
projection chamber (XeTPC) for dark matter search is described. Results from a
prototype detector (XENON3) are presented.
[38]
oai:arXiv.org:physics/0608034 [pdf] - 119179
Gamma Ray Spectroscopy with Scintillation Light in Liquid Xenon
Submitted: 2006-08-03, last modified: 2006-08-04
Scintillation light from gamma ray irradiation in liquid xenon is detected by
two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV
light reflector material, PTFE, is used to optimize the light collection
efficiency. The detector gives a high light yield of 6 photoelectron per keV
(pe/keV), which allows efficient detection of the 122 keV gamma-ray line from
Co-57, with a measured energy resolution of (8.8+/-0.6)% (sigma). The best
achievable energy resolution, by removing the instrumental fluctuations, from
liquid xenon scintillation light is estimated to be around 6-8% (sigma) for
gamma-ray with energy between 662 keV and 122 keV.
[39]
oai:arXiv.org:astro-ph/0601552 [pdf] - 79410
Simultaneous Measurement of Ionization and Scintillation from Nuclear
Recoils in Liquid Xenon as Target for a Dark Matter Experiment
Aprile, E.;
Dahl, C. E.;
DeViveiros, L.;
Gaitskell, R.;
Giboni, K. L.;
Kwong, J.;
Majewski, P.;
Ni, K.;
Shutt, T.;
Yamashita, M.
Submitted: 2006-01-24
We report the first measurements of the absolute ionization yield of nuclear
recoils in liquid xenon, as a function of energy and electric-field.
Independent experiments were carried out with two dual-phase time projection
chamber prototypes, developed for the XENON Dark Matter project. We find that
the charge yield increases with decreasing recoil energy, and exhibits only a
weak field dependence. These results are a first demonstration of the
capability of dual phase xenon detectors to discriminate between electron and
nuclear recoils, a key requirement for a sensitive dark matter search at recoil
energies down to 20 keV.
[40]
oai:arXiv.org:astro-ph/0503621 [pdf] - 72003
Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
Submitted: 2005-03-29
Liquid Xenon (LXe) is expected to be an excellent target and detector medium
to search for dark matter in the form of Weakly Interacting Massive Particles
(WIMPs). Knowledge of LXe ionization and scintillation response to low energy
nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important
for determining the sensitivity of LXe direct detection experiments. Here we
report on new measurements of the scintillation yield of Xe recoils with
kinetic energy as low as 10 keV. The dependence of the scintillation yield on
applied electric field was also measured in the range of 0 to 4 kV/cm. Results
are in good agreement with recent theoretical predictions that take into
account the effect of biexcitonic collisions in addition to the nuclear
quenching effect.
[41]
oai:arXiv.org:physics/0502071 [pdf] - 119079
Performance of a Large Area Avalanche Photodiode in a Liquid Xenon
Ionization and Scintillation Chamber
Submitted: 2005-02-14
Scintillation light produced in liquid xenon (LXe) by alpha particles,
electrons and gamma-rays was detected with a large area avalanche photodiode
(LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a
function of applied electric field. We estimate the quantum efficiency of the
LAAPD to be 45%. The best energy resolution from the light measurement at zero
electric field is 7.5%(sigma) for 976 keV internal conversion electrons from
Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector
used for these measurements was also operated as a gridded ionization chamber
to measure the charge yield. We confirm that using a LAAPD in LXe does not
introduce impurities which inhibit the drifting of free electrons.
[42]
oai:arXiv.org:astro-ph/0407575 [pdf] - 66417
The XENON Dark Matter Search Experiment
Aprile, E.;
Giboni, K. L.;
Majewski, P.;
Ni, K.;
Yamashita, M.;
Gaitskell, R.;
Sorensen, P.;
DeViveiros, L.;
Baudis, L.;
Bernstein, A.;
Hagmann, C.;
Winant, C.;
Shutt, T.;
Kwong, J.;
Oberlack, U.;
McKinsey, D.;
Hasty, R.
Submitted: 2004-07-28
The XENON experiment aims at the direct detection of dark matter in the form
of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering
off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent
liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest
interaction cross section predicted by SUSY models. The TPCs are operated in
dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to
16keV energy, via simultaneous detection of the ionization, through secondary
scintillation in the gas, and primary scintillation in the liquid. Thedistinct
ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or
neutrons), and for electron recoils from background, iskey to the
event-by-event discrimination capability of XENON. A dual phase xenon prototype
has been realized and is currently being tested, along with otherprototypes
dedicated to other measurements relevant to the XENON program. As part of the
R&D phase, we will realize and move underground a first XENON module (XENON10)
with at least 10 kg fiducial mass to measure the background rejection
capability and to optimize the conditions for continuous and stable detector
operation underground. We present some of the results from the ongoing R&D and
summarize the expected performance of the 10 kg experiment, from MonteCarlo
simulations. The main design features of the 100 kg detector unit(XENON100),
with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will
also be presented.
[43]
oai:arXiv.org:astro-ph/0212005 [pdf] - 53395
The LXeGRIT Compton Telescope Prototype: Current Status and Future
Prospects
Aprile, E.;
Curioni, A.;
Giboni, K. L.;
Kobayashi, M.;
Oberlack, U. G.;
Chupp, E. L.;
Dunphy, P. P.;
Doke, T.;
Kikuchi, J.;
Ventura, S.
Submitted: 2002-11-30, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel concept of Compton telescope, based
on the complete 3-dimensional reconstruction of the sequence of interactions of
individual gamma rays in one position sensitive detector. This balloon-borne
telescope consists of an unshielded time projection chamber with an active
volume of 400 cm$^2 \times 7$ cm filled with high purity liquid xenon. Four VUV
PMTs detect the fast xenon scintillation light signal, providing the event
trigger. 124 wires and 4 anodes detect the ionization signals, providing the
event spatial coordinates and total energy. In the period 1999 -- 2001, LXeGRIT
has been extensively tested both in the laboratory and at balloon altitude, and
its response in the MeV region has been thoroughly characterized. Here we
summarize some of the results on pre-flight calibration, event reconstruction
techniques, and performance during a 27 hour balloon flight on October 4 -- 5.
We further present briefly the on-going efforts directed to improve the
performance of this prototype towards the requirements for a base module of a
next-generation Compton telescope.
[44]
oai:arXiv.org:astro-ph/0211584 [pdf] - 53319
On the Background Rate in the LXeGRIT Instrument during the 2000 Balloon
Flight
Curioni, A.;
Aprile, E.;
Giboni, K. L.;
Kobayashi, M.;
Oberlack, U. G.;
Chupp, E. L.;
Dunphy, P. P.;
Doke, T.;
Kikuchi, J.;
Ventura, S.
Submitted: 2002-11-26, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel Compton telescope for MeV gamma-ray
astrophysics based on a Liquid Xenon Time Projection Chamber (LXeTPC),
sensitive in the energy band of 0.15-10 MeV. In this homogeneous, 3D position
sensitive detector, gamma rays with at least two interactions in the sensitive
volume of 2800 cm$^{3}$, are imaged as in a standard Compton telescope.
Gamma-rays with a single interaction cannot be imaged and constitute a
background which can be easily identified and rejected. Charged particles and
localized beta-particles background is also easily suppressed based on the TPC
localization capability with millimeter resolution. A measurement of the total
gamma-ray background rate in near space conditions and the background rejection
power of the LXeTPC was a primary goal of the LXeGRIT balloon flight program.
We present here a preliminary analysis addressing this question, based on
balloon flight data acquired during the Oct 4-5, 2000 LXeGRIT balloon flight
from Ft. Sumner, NM. In this long duration (27 hr) balloon experiment, the
LXeGRIT TPC was not surrounded by any gamma-ray or charged particle shield.
Single site events and charged particles were mostly rejected on-line at the
first and second trigger level. The remaining count rate of single-site \g-ray
events, at an average atmospheric depth of 3.2 g cm$^{-2}$, is consistent with
that expected from atmospheric and diffuse gamma-ray background, taking into
account the instrument mass model and response.
[45]
oai:arXiv.org:astro-ph/0207670 [pdf] - 1591929
XENON: a 1 tonne Liquid Xenon Experiment for a Sensitive Dark Matter
Search
Aprile, E.;
Baltz, E. A.;
Curioni, A.;
Giboni, K-L.;
Hailey, C. J.;
Hui, L.;
Kobayashi, M.;
Ni, K.;
Craig, W. W.;
Gaitskell, R. J.;
Oberlack, U.;
Shutt, T.
Submitted: 2002-07-31
XENON is a novel liquid xenon experiment concept for a sensitive dark matter
search using a 1-tonne active target, distributed in an array of ten
independent time projection chambers. The design relies on the simultaneous
detection of ionization and scintillation signals in liquid xenon, with the
goal of extracting as much information as possible on an event-by-event basis,
while maintaining most of the target active. XENON is expected to have
effective and redundant background identification and discrimination power,
higher than 99.5%, and to achieve a very low threshold, on the order of 4 keV
visible recoil energy.
Based on this expectation and the 1-tonne mass of active xenon, we project a
sensitivity of 0.0001 events/kg/day, after 3 yr operation in an appropriate
underground location. The XENON experiment has been recently proposed to the
National Science Foundation (NSF) for an initial development phase leading to
the development of the 100 kg unit module.
[46]
oai:arXiv.org:astro-ph/0012398 [pdf] - 1232610
Preliminary Results from the 1999 Balloon Flight of the Liquid Xenon
Gamma-Ray Imaging Telescope (LXeGRIT)
Aprile, E.;
Oberlack, U. G.;
Curioni, A.;
Egorov, V.;
Giboni, K. -L.;
Ventura, ;
S.;
Doke, ;
T.;
Kikuchi, J.;
Takizawa, K.;
Chupp, ;
E. L.;
Dunphy, P. P.
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope employing a large volume liquid
xenon time projection chamber (LXeTPC) as the central gamma-ray detector. It is
designed to image gamma rays in the energy range of 200 keV to 20 MeV, with an
angular resolution of about 3 degrees (1 sigma) at 2 MeV, within a
field-of-view (FOV) of about 1 sr. The detector's energy and three-dimensional
spatial resolution as measured during pre-flight calibration experiments, are
$\Delta E_\mathrm{lxe}/E=8.8% : \sqrt{1\MeV /E}$ and < 1mm RMS, respectively.
The detection efficiency for Compton events varies between 1.5% and 4%
depending on energy and event selection. We describe the instrument as flown on
May 7, 1999 and review its overall performance at balloon altitude. The launch
occurred at 13:26:54 UT from Ft. Sumner, New Mexico and the flight was
terminated about 9 hours later. The Crab was in the instrument FOV for a few
hours. Analysis of these data is in progress.
[47]
oai:arXiv.org:astro-ph/0012395 [pdf] - 39984
Performance of the Light Trigger System in the Liquid Xenon Gamma-Ray
Telescope LXeGRIT
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics,
based on a liquid xenon time projection chamber with charge and light readout.
The energy and direction of an incident gamma-ray is reconstructed from the
three-dimensional locations and energy deposits of individual interactions
taking place in the homogeneous detector volume. While the charge signals
provide energy information and X-Y positions, the fast xenon scintillation
light signal is used to trigger the detector. The drift time measurement,
referred to the time of the trigger signal, gives the Z-position with the known
drift velocity. The light is detected by four UV-sensitive photomultiplier
tubes (PMTs). The logical OR of the PMT signals triggers the data acquisition
system with an efficiency which depends on the event energy and location, as
well as on the discriminator thresholds used on the individual PMTs. Results
from experiments with a tagged 22Na source give the spatial distribution of the
light trigger efficiency for 511 keV gamma-rays. When averaged over the whole
sensitive volume amd all PMTs, the trigger efficiency is 47% or 40% for two
discriminator windows used during the LXeGRIT balloon flight of 1999. These
values are strongly affected by the different sensitivity of each PMT. The
corresponding average efficiency at 511 keV for the best of the four PMTs is in
fact 63%, and approaches 100% for interactions taking place in a small volume
right above the PMT.
[48]
oai:arXiv.org:astro-ph/0012276 [pdf] - 39865
An Upgraded Data Acquisition System for the Balloon-Borne Liquid Xenon
Gamma-Ray Telescope LXeGRIT
Submitted: 2000-12-12, last modified: 2000-12-14
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics,
based on a liquid xenon time projection chamber (LXe-TPC) with charge and light
readout. The first balloon flights in 1997 revealed limitations of the trigger
electronics and the data acquisition (DAQ) system, leading to their upgrade.
New electronics was developed to handle the xenon scintillation light trigger.
The original processor module was replaced by a commercial VME processor. The
telemetry rate was doubled to 2 x 500 kbps and onboard data storage on hard
disks was implemented. Relying on a robust real-time operating system, the new
DAQ software adopts an object oriented design to implement the diverse tasks of
trigger handling, data selection, transmission, and storage, as well as DAQ
control and monitor functions. The new systems performed well during two
flights in Spring 1999 and Fall 2000. In the 2000 flight, the DAQ system was
able to handle 300-350 triggers/s out of a total of about 650 Hz, including
charged particles.
[49]
oai:arXiv.org:astro-ph/0012297 [pdf] - 1232606
Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray
Imaging Telescope (LXeGRIT)
Aprile, E.;
Curioni, A.;
Egorov, V.;
Giboni, K. -L.;
Oberlack, U. G.;
Ventura, ;
S.;
Doke, ;
T.;
Kikuchi, J.;
Takizawa, K.;
Chupp, ;
E. L.;
Dunphy, P. P.
Submitted: 2000-12-13
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time
projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of
0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled
with high purity LXe. Both ionization and scintillation light signals are
detected to measure the energy deposits and the three spatial coordinates of
individual \g -ray interactions within the sensitive volume. The TPC has been
characterized with repeated measurements of its spectral and Compton imaging
response to \g -rays from radioactive sources such as \na, \cs, \yt and Am-Be.
The detector shows a linear response to \g -rays in the energy range 511 keV
-4.4 MeV, with an energy resolution (FWHM) of $ \Delta E/E=8.8% \: \sqrt{1\MeV
/E}$. Compton imaging of \yt \g -ray events with two detected interactions is
consistent with an angular resolution of $\sim$ 3 degrees (RMS) at 1.8 MeV.
[50]
oai:arXiv.org:astro-ph/0012296 [pdf] - 1232605
Compton scattering sequence reconstruction algorithm for the liquid
xenon gamma-ray imaging telescope (LXeGRIT)
Submitted: 2000-12-13
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born
experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main
detector is a time projection chamber filled with high purity liquid xenon
(LXeTPC), in which the three-dimensional location and energy deposit of
individual \g -ray interactions are accurately measured in one homogeneous
volume. To determine the \g -ray initial direction (Compton imaging), as well
as to reject background, the correct sequence of interactions has to be
determined. Here we report the development and optimization of an algorithm to
reconstruct the Compton scattering sequence and show its performance on Monte
Carlo events and LXeGRIT data.