Normalized to: Gers, L.
[1]
oai:arXiv.org:1807.01938 [pdf] - 1711133
Veloce Rosso: Australia's new precision radial velocity spectrograph
Gilbert, James;
Bergmann, Christoph;
Bloxham, Gabe;
Boz, Robert;
Brookfield, Robert;
Carkic, Tom;
Carter, Brad;
Case, Scott;
Churilov, Vladimir;
Ellis, Michael;
Gausachs, Gaston;
Gers, Luke;
Gray, Doug;
Herrald, Nicholas;
Ireland, Michael;
Jones, Damien;
Kripak, Yevgen;
Lawrence, Jon;
O'Brien, Ellie;
Price, Ian;
Robertson, Matthew;
Schwab, Christian;
Tinney, Chris;
Vaccarella, Annino;
Vest, Colin;
Wright, Duncan;
Zhelem, Ross
Submitted: 2018-07-05
Veloce is an ultra-stable fibre-fed R4 echelle spectrograph for the 3.9 m
Anglo-Australian Telescope. The first channel to be commissioned, Veloce
'Rosso', utilises multiple low-cost design innovations to obtain Doppler
velocities for Sun-like and M-dwarf stars at <1 m/s precision. The spectrograph
has an asymmetric white-pupil format with a 100-mm beam diameter, delivering
R>75,000 spectra over a 580-950 nm range for the Rosso channel. Simultaneous
calibration is provided by a single-mode pulsed laser frequency comb in tandem
with a traditional arc lamp. A bundle of 19 object fibres provides a 2.4" field
of view for full sampling of stellar targets from the AAT site. Veloce is
housed in dual environmental enclosures that maintain positive air pressure at
a stability of +/-0.3 mbar, with a thermal stability of +/-0.01 K on the
optical bench. We present a technical overview and early performance data from
Australia's next major spectroscopic machine.
[2]
oai:arXiv.org:1606.07140 [pdf] - 1530883
Development and construction of MAROON-X
Submitted: 2016-06-22
We report on the development and construction of a new fiber-fed,
red-optical, high-precision radial-velocity spectrograph for one of the twin
6.5m Magellan Telescopes in Chile. MAROON-X will be optimized to find and
characterize rocky planets around nearby M dwarfs with an intrinsic per
measurement noise floor below 1 m/s. The instrument is based on a commercial
echelle spectrograph customized for high stability and throughput. A microlens
array based pupil slicer and double scrambler, as well as a rubidium-referenced
etalon comb calibrator will turn this spectrograph into a high-precision
radial-velocity machine. MAROON-X will undergo extensive lab tests in the
second half of 2016.
[3]
oai:arXiv.org:1509.00129 [pdf] - 1530302
First Light Results from the Hermes Spectrograph at the AAT
Sheinis, Andrew;
Anguiano, Borja;
Asplund, Martin;
Bacigalupo, Carlos;
Barden, Sam;
Birchall, Michael;
Bland-Hawthorn, Joss;
Brzeski, Jurek;
Cannon, Russell;
Carollo, Daniela;
Case, Scott;
Casey, Andrew;
Churilov, Vladimir;
Warrick, Couch;
Dean, Robert;
De Silva, Gayandhi;
D'Orazi, Valentina;
Duong, Ly;
Farrell, Tony;
Fiegert, Kristin;
Freeman, Kenneth;
Gabriella, Frost;
Gers, Luke;
Goodwin, Michael;
Gray, Doug;
Green, Andrew;
Heald, Ron;
Heijmans, Jeroen;
Ireland, Michael;
Jones, Damien;
Kafle, Prajwal;
Keller, Stefan;
Klauser, Urs;
Kondrat, Yuriy;
Kos, Janez;
Lawrence, Jon;
Lee, Steve;
Mali, Slavko;
Martell, Sarah;
Mathews, Darren;
Mayfield, Don;
Miziarski, Stan;
Muller, Rolf;
Pai, Naveen;
Patterson, Robert;
Penny, Ed;
Orr, David;
Schlesinger, Katharine;
Sharma, Sanjib;
Shortridge, Keith;
Simpson, Jeffrey;
Smedley, Scott;
Smith, Greg;
Stafford, Darren;
Staszak, Nicholas;
Vuong, Minh;
Waller, Lewis;
de Boer, Elizabeth Wylie;
Xavier, Pascal;
Zheng, Jessica;
Zhelem, Ross;
Zucker, Daniel;
Zwitter, Tomaz
Submitted: 2015-08-31
The High Efficiency and Resolution Multi Element Spectrograph, HERMES, is a
facility-class optical spectrograph for the Anglo-Australian Telescope (AAT).
It is designed primarily for Galactic Archaeology, the first major attempt to
create a detailed understanding of galaxy formation and evolution by studying
the history of our own galaxy, the Milky Way. The goal of the GALAH survey is
to reconstruct the mass assembly history of the Milky Way through a detailed
chemical abundance study of one million stars. The spectrograph is based at the
AAT and is fed by the existing 2dF robotic fiber positioning system. The
spectrograph uses volume phase holographic gratings to achieve a spectral
resolving power of 28,000 in standard mode and also provides a high-resolution
mode ranging between 40,000 and 50,000 using a slit mask. The GALAH survey
requires an SNR greater than 100 for a star brightness of V ?= 14 in an
exposure time of one hour. The total spectral coverage of the four channels is
about 100 nm between 370 and 1000 nm for up to 392 simultaneous targets within
the 2-degree field of view. HERMES has been commissioned over three runs,
during bright time in October, November, and December 2013, in parallel with
the beginning of the GALAH pilot survey, which started in November 2013. We
present the first-light results from the commissioning run and the beginning of
the GALAH survey, including performance results such as throughput and
resolution, as well as instrument reliability.
[4]
oai:arXiv.org:1407.6438 [pdf] - 1215881
PRAXIS: low thermal emission high efficiency OH suppressed fibre
spectrograph
Content, Robert;
Bland-Hawthorn, Joss;
Ellis, Simon;
Gers, Luke;
Haynes, Roger;
Horton, Anthony;
Lawrence, Jon;
Leon-Saval, Sergio;
Lindley, Emma;
Min, Seong-Sik;
Shortridge, Keith;
Staszak, Nick;
Trinh, Christopher;
Xavier, Pascal;
Zhelem, Ross
Submitted: 2014-07-23, last modified: 2014-07-29
PRAXIS is a second generation instrument that follows on from GNOSIS, which
was the first instrument using fibre Bragg gratings for OH background
suppression. The Bragg gratings reflect the NIR OH lines while being
transparent to light between the lines. This gives a much higher signal-noise
ratio at low resolution but also at higher resolutions by removing the
scattered wings of the OH lines. The specifications call for high throughput
and very low thermal and detector noise so that PRAXIS will remain sky noise
limited. The optical train is made of fore-optics, an IFU, a fibre bundle, the
Bragg grating unit, a second fibre bundle and a spectrograph. GNOSIS used the
pre-existing IRIS2 spectrograph while PRAXIS will use a new spectrograph
specifically designed for the fibre Bragg grating OH suppression and optimised
for 1470 nm to 1700 nm (it can also be used in the 1090 nm to 1260 nm band by
changing the grating and refocussing). This results in a significantly higher
transmission due to high efficiency coatings, a VPH grating at low incident
angle and low absorption glasses. The detector noise will also be lower.
Throughout the PRAXIS design special care was taken at every step along the
optical path to reduce thermal emission or stop it leaking into the system.
This made the spectrograph design challenging because practical constraints
required that the detector and the spectrograph enclosures be physically
separate by air at ambient temperature. At present, the instrument uses the
GNOSIS fibre Bragg grating OH suppression unit. We intend to soon use a new OH
suppression unit based on multicore fibre Bragg gratings which will allow
increased field of view per fibre. Theoretical calculations show that the gain
in interline sky background signal-noise ratio over GNOSIS may very well be as
high as 9 with the GNOSIS OH suppression unit and 17 with the multicore fibre
OH suppression unit.
[5]
oai:arXiv.org:1212.1201 [pdf] - 650886
GNOSIS: the first instrument to use fibre Bragg gratings for OH
suppression
Trinh, Christopher Q.;
Ellis, Simon C.;
Bland-Hawthorn, Joss;
Lawrence, Jon S.;
Horton, Anthony J.;
Leon-Saval, Sergio G.;
Shortridge, Keith;
Bryant, Julia;
Case, Scott;
Colless, Matthew;
Couch, Warick;
Freeman, Kenneth;
Loehmannsroeben, Hans-Gerd;
Gers, Luke;
Glazebrook, Karl;
Haynes, Roger;
Lee, Steve;
O'Byrne, John;
Miziarski, Stan;
Roth, Martin M.;
Schmidt, Brian;
Tinney, Christopher G.;
Zheng, Jessica
Submitted: 2012-12-05, last modified: 2013-04-11
GNOSIS is a prototype astrophotonic instrument that utilizes OH suppression
fibres consisting of fibre Bragg gratings and photonic lanterns to suppress the
103 brightest atmospheric emission doublets between 1.47-1.7 microns. GNOSIS
was commissioned at the 3.9-meter Anglo-Australian Telescope with the IRIS2
spectrograph to demonstrate the potential of OH suppression fibres, but may be
potentially used with any telescope and spectrograph combination. Unlike
previous atmospheric suppression techniques GNOSIS suppresses the lines before
dispersion and in a manner that depends purely on wavelength. We present the
instrument design and report the results of laboratory and on-sky tests from
commissioning. While these tests demonstrated high throughput and excellent
suppression of the skylines by the OH suppression fibres, surprisingly GNOSIS
produced no significant reduction in the interline background and the
sensitivity of GNOSIS and IRIS2 is about the same as IRIS2. It is unclear
whether the lack of reduction in the interline background is due to physical
sources or systematic errors as the observations are detector noise-dominated.
OH suppression fibres could potentially impact ground-based astronomy at the
level of adaptive optics or greater. However, until a clear reduction in the
interline background and the corresponding increasing in sensitivity is
demonstrated optimized OH suppression fibres paired with a fibre-fed
spectrograph will at least provide a real benefits at low resolving powers.
[6]
oai:arXiv.org:1301.0670 [pdf] - 610414
CYCLOPS2: the fibre image slicer upgrade for the UCLES high resolution
spectrograph
Horton, Anthony;
Tinney, C. G.;
Case, Scott;
Farrell, Tony;
Gers, Luke;
Jones, Damien;
Lawrence, Jon;
Miziarski, Stan;
Staszak, Nick;
Orr, David;
Vuong, Minh;
Waller, Lew;
Zhelem, Ross
Submitted: 2013-01-03
CYCLOPS2 is an upgrade for the UCLES high resolution spectrograph on the
Anglo-Australian Telescope, scheduled for commissioning in semester 2012A. By
replacing the 5 mirror Coud\'e train with a Cassegrain mounted fibre-based
image slicer CYCLOPS2 simultaneously provides improved throughput, reduced
aperture losses and increased spectral resolution. Sixteen optical fibres
collect light from a 5.0 arcsecond^2 area of sky and reformat it into the
equivalent of a 0.6 arcsecond wide slit, delivering a spectral resolution of R
= 70000 and up to twice as much flux as the standard 1 arcsecond slit of the
Coud\'e train. CYCLOPS2 also adds support for simultaneous ThAr wavelength
calibration via a dedicated fibre. CYCLOPS2 consists of three main components,
the fore-optics unit, fibre bundle and slit unit. The fore optics unit
incorporates magnification optics and a lenslet array and is designed to mount
to the CURE Cassegrain instrument interface, which provides acquisition,
guiding and calibration facilities. The fibre bundle transports the light from
the Cassegrain focus to the UCLES spectrograph at Coud\'e and also includes a
fibre mode scrambler. The slit unit consists of the fibre slit and relay optics
to project an image of the slit onto the entrance aperture of the UCLES
spectrograph. CYCLOPS2 builds on experience with the first generation CYCLOPS
fibre system, which we also describe in this paper. We present the science case
for an image slicing fibre feed for echelle spectroscopy and describe the
design of CYCLOPS and CYCLOPS2.
[7]
oai:arXiv.org:1206.6551 [pdf] - 1124455
Suppression of the near-infrared OH night sky lines with fibre Bragg
gratings - first results
Ellis, S. C.;
Bland-Hawthorn, J.;
Lawrence, J.;
Horton, A. J.;
Trinh, C.;
Leon-Saval, S. G.;
Shortridge, K.;
Bryant, J.;
Case, S.;
Colless, M.;
Couch, W.;
Freeman, K.;
Gers, L.;
Glazebrook, K.;
Haynes, R.;
Lee, S.;
Loehmannsroeben, H. -G.;
Byrne, J. O.;
Miziarski, S.;
Roth, M.;
Schmidt, B.;
Tinney, C. G.;
Zheng, J.
Submitted: 2012-06-27
The background noise between 1 and 1.8 microns in ground-based instruments is
dominated by atmospheric emission from hydroxyl molecules. We have built and
commissioned a new instrument, GNOSIS, which suppresses 103 OH doublets between
1.47 - 1.7 microns by a factor of ~1000 with a resolving power of ~10,000. We
present the first results from the commissioning of GNOSIS using the IRIS2
spectrograph at the AAT. The combined throughput of the GNOSIS fore-optics,
grating unit and relay optics is ~36 per cent, but this could be improved to
~46 per cent with a more optimal design. We measure strong suppression of the
OH lines, confirming that OH suppression with fibre Bragg gratings will be a
powerful technology for low resolution spectroscopy. The integrated OH
suppressed background between 1.5 and 1.7 microns is reduced by a factor of 9
compared to a control spectrum using the same system without suppression. The
potential of low resolution OH suppressed spectroscopy is illustrated with
example observations.
The GNOSIS background is dominated by detector dark current below 1.67
microns and by thermal emission above 1.67 microns. After subtracting these we
detect an unidentified residual interline component of ~ 860 +/ 210
ph/s/m^2/micron/arcsec^2. This component is equally bright in the suppressed
and control spectra. We have investigated the possible source of the interline
component, but were unable to discriminate between a possible instrumental
artifact and intrinsic atmospheric emission. Resolving the source of this
emission is crucial for the design of fully optimised OH suppression
spectrographs. The next generation OH suppression spectrograph will be focussed
on resolving the source of the interline component, taking advantage of better
optimisation for a FBG feed. We quantify the necessary improvements for an
optimal OH suppressing fibre spectrograph design.