Normalized to: Germain, M.
[1]
oai:arXiv.org:1207.2285 [pdf] - 1124711
PIONIER: a status report
Bouquin, J. -B. Le;
Berger, J. -P.;
Zins, G.;
Lazareff, B.;
Jocou, L.;
Kern, P.;
Millan-Gabet, R.;
Traub, W.;
Haguenauer, P.;
Absil, O.;
Augereau, J. -C.;
Benisty, M.;
Blind, N.;
Delboulbe, A.;
Feautrier, P.;
Germain, M.;
Gillier, D.;
Gitton, P.;
Kiekebusch, M.;
Knudstrup, J.;
Lizon, J. -L;
Magnard, Y.;
Malbet, F.;
Maurel, D.;
Menard, F.;
Micallef, M.;
Michaud, L.;
Moulin, T.;
Popovic, D.;
Perraut, K.;
Rabou, P.;
Rochat, S.;
Roussel, F.;
Roux, A.;
Stadler, E.;
Tatulli, E.
Submitted: 2012-07-10
The visitor instrument PIONIER provides VLTI with improved imaging
capabilities and sensitivity. The instrument started routinely delivering
scientific data in November 2010, that is less than 12 months after being
approved by the ESO Science and Technical Committee. We recall the challenges
that had to be tackled to design, built and commission PIONIER. We summarize
the typical performances and some astrophysical results obtained so far. We
conclude this paper by summarizing lessons learned.
[2]
oai:arXiv.org:1109.1918 [pdf] - 1083951
PIONIER: a 4-telescope visitor instrument at VLTI
Bouquin, Jean-Baptiste Le;
Berger, J. -P.;
Lazareff, B.;
Zins, G.;
Haguenauer, P.;
Jocou, L.;
Kern, P.;
Millan-Gabet, R.;
Traub, W.;
Absil, O.;
Augereau, J. -C.;
Benisty, M.;
Blind, N.;
Bonfils, X.;
Bourget, P.;
Delboulbe, A.;
Feautrier, P.;
Germain, M.;
Gitton, P.;
Gillier, D.;
Kiekebusch, M.;
Kluska, J.;
Knudstrup, J.;
Labeye, P.;
Lizon, J. -L.;
Monin, J. -L.;
Magnard, Y.;
Malbet, F.;
Maurel, D.;
Menard, F.;
Micallef, M.;
Michaud, L.;
Montagnier, G.;
Morel, S.;
Moulin, T.;
Perraut, K.;
Popovic, D.;
Rabou, P.;
Rochat, S.;
Rojas, C.;
Roussel, F.;
Roux, A.;
Stadler, E.;
Stefl, S.;
Tatulli, E.;
Ventura, N.
Submitted: 2011-09-09
PIONIER stands for Precision Integrated-Optics Near-infrared Imaging
ExpeRiment. It combines four 1.8m Auxilliary Telescopes or four 8m Unit
Telescopes of the Very Large Telescope Interferometer (ESO, Chile) using an
integrated optics combiner. The instrument has been integrated at IPAG starting
in December 2009 and commissioned at the Paranal Observatory in October 2010.
It provides scientific observations since November 2010. In this paper, we
detail the instrumental concept, we describe the standard operational modes and
the data reduction strategy. We present the typical performance and discuss how
to improve them. This paper is based on laboratory data obtained during the
integrations at IPAG, as well as on-sky data gathered during the commissioning
at VLTI. We illustrate the imaging capability of PIONIER on the binaries
deltaSco and HIP11231. PIONIER provides 6 visibilities and 3 independent
closure phases in the H band, either in a broadband mode or with a low spectral
dispersion (R=40), using natural light (i.e. unpolarized). The limiting
magnitude is Hmag=7 in dispersed mode under median atmospheric conditions
(seeing<1", tau0>3ms) with the 1.8m Auxiliary Telescopes. We demonstrate a
precision of 0.5deg on the closure phases. The precision on the calibrated
visibilities ranges from 3 to 15% depending on the atmospheric conditions.
PIONIER has been installed and successfully tested as a visitor instrument for
the VLTI. It permits high angular resolution imaging studies at an
unprecedented level of sensitivity. The successful combination of the four 8m
Unit Telescopes in March 2011 demonstrates that VLTI is ready for 4-telescope
operation.
[3]
oai:arXiv.org:1008.5352 [pdf] - 1034577
PIONIER: a visitor instrument for the VLTI
Berger, J. -P.;
Zins, G.;
Lazareff, B.;
Lebouquin, J. -B.;
Jocou, L.;
Kern, P.;
Millan-Gabet, R.;
Traub, W.;
Haguenauer, P.;
Absil, O.;
Augereau, J. -C.;
Benisty, M.;
Blind, N.;
Bonfils, X.;
Delboulbe, A.;
Feautrier, P.;
Germain, M.;
Gillier, D.;
Gitton, P.;
Kiekebusch, M.;
Knudstrup, J.;
Lizon, J. -L;
Magnard, Y.;
Malbet, F.;
Maurel, D.;
Menard, F.;
Micallef, M.;
Michaud, L.;
Morel, S.;
Moulin, T.;
Popovic, D.;
Perraut, K.;
Rabou, P.;
Rochat, S.;
Roussel, F.;
Roux, A.;
Stadler, E.;
Tatulli, E.
Submitted: 2010-08-31
PIONIER is a 4-telescope visitor instrument for the VLTI, planned to see its
first fringes in 2010. It combines four ATs or four UTs using a pairwise ABCD
integrated optics combiner that can also be used in scanning mode. It provides
low spectral resolution in H and K band. PIONIER is designed for imaging with a
specific emphasis on fast fringe recording to allow closure-phases and
visibilities to be precisely measured. In this work we provide the detailed
description of the instrument and present its updated status.
[4]
oai:arXiv.org:1003.2136 [pdf] - 1025634
The Third US Naval Observatory CCD Astrograph Catalog (UCAC3)
Zacharias, N.;
Finch, C.;
Girard, T.;
Hambly, N.;
Wycoff, G.;
Zacharias, M.;
Castillo, D.;
Corbin, T.;
DiVittorio, M.;
Dutta, S.;
Gaume, R.;
Gauss, S.;
Germain, M.;
Hall, D.;
Hartkopf, W.;
Hsu, D.;
Holdenried, E.;
Makarov, V.;
Martines, M.;
Mason, B.;
Monet, D.;
Rafferty, T.;
Rhodes, A.;
Siemers, T.;
Smith, D.;
Tilleman, T.;
Urban, S.;
Wieder, G.;
Winter, L.;
Young, A.
Submitted: 2010-03-09
The third US Naval Observatory (USNO) CCD Astrograph Catalog, UCAC3 was
released at the IAU General Assembly on 2009 August 10. It is the first all-sky
release in this series and contains just over 100 million objects, about 95
million of them with proper motions, covering about R = 8 to 16 magnitudes.
Current epoch positions are obtained from the observations with the 20 cm
aperture USNO Astrograph's "red lens", equipped with a 4k by 4k CCD. Proper
motions are derived by combining these observations with over 140 ground- and
space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as
unpublished measures of over 5000 plates from other astrographs. For most of
the faint stars in the Southern Hemisphere the Yale/San Juan first epoch plates
from the SPM program (YSJ1) form the basis for proper motions. These data are
supplemented by all-sky Schmidt plate survey astrometry and photometry obtained
from the SuperCOSMOS project, as well as 2MASS near-IR photometry. Major
differences of UCAC3 data as compared to UCAC2 include a completely new raw
data reduction with improved control over systematic errors in positions,
significantly improved photometry, slightly deeper limiting magnitude, coverage
of the north pole region, greater completeness by inclusion of double stars and
weak detections. This of course leads to a catalog which is not as "clean" as
UCAC2 and problem areas are outlined for the user in this paper. The positional
accuracy of stars in UCAC3 is about 15 to 100 mas per coordinate, depending on
magnitude, while the errors in proper motions range from 1 to 10 mas/yr
depending on magnitude and observing history, with a significant improvement
over UCAC2 achieved due to the re-reduced SPM data and inclusion of more
astrograph plate data unavailable at the time of UCAC2.
[5]
oai:arXiv.org:astro-ph/0009497 [pdf] - 1232559
Astrophysical Quantities of Cepheid Variables Measured with the NPOI
Submitted: 2000-09-29
We present mean angular diameters for two cepheid variables, alpha Ursae
Minoris and zeta Geminorum, determined with the Navy Prototype Optical
Interferometer (NPOI). We present linear radii for these cepheids and two
additional cepheids, delta Cephei and eta Aquilae, previously observed at the
NPOI. We find the limb-darkened angular diameter of alpha Ursae Minoris and of
zeta Geminorum to be 3.28 +/- 0.02 and 1.55 +/- 0.09 milliarcseconds
respectively. Using trigonometric parallaxes, we find the linear radii of alpha
Ursae Minoris, zeta Geminorum, delta Cephei and eta Aquilae to be 46 (+/- 3),
60 (+25, -14), 45 (+8, -6), and 69 (+28, -15) Solar radii respectively. We
compare the pulsation periods and linear radii of this sample of cepheids,
which range in period from three to 11 days, to theoretical and empirical
period-radius and period-radius-mass relations found in the literature. We find
that the observed diameter of alpha Ursae Minoris is in excellent agreement
with the predicted diameter as determined from both surface brightness
techniques and theory only if alpha Ursae Minoris is a first overtone pulsator.
[6]
oai:arXiv.org:astro-ph/0009398 [pdf] - 38240
Diameters of delta Cephei and eta Aquilae Measured with the Navy
Prototype Optical Interferometer
Submitted: 2000-09-25
We have measured the diameters of the Cepheid variables delta Cephei (18
nights) and eta Aquilae (11 nights) with the Navy Prototype Optical
Interferometer. The primary results of these observations are the mean angular
diameters <theta(LD)> of these Cepheids: 1.520 +/- 0.014 milliseconds of arc
(mas) for delta Cep and 1.69 +/- 0.04 mas for eta Aql. We also report
limb-darkened diameters for the check stars in this program: for beta Lac,
theta(LD) = 1.909 +/- 0.011 mas, and for 12 Aql, theta(LD) = 2.418 +/- 0.010
mas. When combined with radius estimates from period-radius relations in the
literature, the Cepheid angular diameters suggest distances slightly smaller
than, but still consistent with, the Hipparcos distances. Pulsations are weakly
detected at a level of about 1.5 sigma to 2 sigma for both Cepheids.
[7]
oai:arXiv.org:astro-ph/9907213 [pdf] - 107438
The Full-sky Astrometric Mapping Explorer -- Astrometry for the New
Millennium
Horner, Scott D.;
Germain, Marvin E.;
Greene, Thomas P.;
Harris, Fred H.;
Johnson, Mark S.;
Johnston, Kenneth J.;
Monet, David G.;
Murison, Marc A.;
Phillips, James D.;
Reasenberg, Robert D.;
Seidelmann, P. Kenneth;
Urban, Sean E.;
Vassar, Richard H.
Submitted: 1999-07-15
FAME is designed to perform an all-sky, astrometric survey with unprecedented
accuracy. It will create a rigid astrometric catalog of 4x10^7 stars with 5 <
m_V < 15. For bright stars, 5 < m_V < 9, FAME will determine positions and
parallaxes accurate to < 50 microarcseconds, with proper motion errors < 50
microarcseconds/year. For fainter stars, 9 < m_V < 15, FAME will determine
positions and parallaxes accurate to < 500 microarcseconds, with proper motion
errors < 500 microarcseconds/year. It will also collect photometric data on
these 4 x 10^7 stars in four Sloan DSS colors.