oai:arXiv.org:1904.01944 [pdf] - 2065154
Development of Spherical Proportional Counter for light WIMP search
within NEWS-G collaboration
Submitted: 2019-04-03, last modified: 2019-05-03
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) has a
broad range of applications. In this work, we will focus on the light WIMP Dark
Matter particle search, that is, below a few GeV. The NEWS-G collaboration
operates a 60 cm diameter detector at Modane underground laboratory (LSM).
Running the detector at 3 b of Neon gas, some competitive limits have been set
down to 0.5 GeV WIMP mass thanks to an energy threshold of around 100 eV. To
reach better performances, the next generation of SPC (140cm), NEWS-G SNO, is
under construction. We will focus here on the fabrication method, the different
low energy calibration methods using 37Ar, neutron and UV laser, on the
cleaning methods to remove the surface contamination and mitigation of 210Pb
bulk contamination.