Normalized to: Gerber, K.
[1]
oai:arXiv.org:2006.11875 [pdf] - 2119173
GREGOR: Optics Redesign and Updates from 2018-2020
Submitted: 2020-06-21
The GREGOR telescope was inaugurated in 2012. In 2018, we started a complete
upgrade, involving optics, alignment, instrumentation, mechanical upgrades for
vibration reduction, updated control systems, and building enhancements and, in
addition, adapted management and policies. This paper describes all major
updates performed during this time. Since 2012, all powered mirrors except for
M1 were exchanged. Starting from 2020, GREGOR observes with diffraction-limited
performance and a new optics and instrument layout.
[2]
oai:arXiv.org:1009.3196 [pdf] - 1040623
The Wave-Front Correction System for the Sunrise Balloon-Borne Solar
Observatory
Berkefeld, T.;
Schmidt, W.;
Soltau, D.;
Bell, A.;
Doerr, H. P.;
Feger, B.;
Friedlein, R.;
Gerber, K.;
Heidecke, F.;
Kentischer, T.;
Lühe, O. v. d.;
Sigwarth, M.;
Wälde, E.;
Barthol, P.;
Deutsch, W.;
Gandorfer, A.;
Germerott, D.;
Grauf, B.;
Meller, R.;
Alvarez-Herrero, A.;
Knölker, M.;
Pillet, V. Martinez;
Solanki, S. K.;
Title, A. M.
Submitted: 2010-09-16
This paper describes the wave-front correction system developed for the
Sunrise balloon telescope, and provides information about its in-flight
performance. For the correction of low-order aberrations, a Correlating
Wave-Front Sensor (CWS) was used. It consisted of a six-element Shack-Hartmann
wave-front sensor (WFS), a fast tip-tilt mirror for the compensation of image
motion, and an active telescope secondary mirror for focus correction. The CWS
delivered a stabilized image with a precision of 0.04 arcsec (rms), whenever
the coarse pointing was better than 90 arcsec peak-to-peak. The automatic focus
adjustment maintained a focus stability of 0.01 waves in the focal plane of the
CWS. During the 5.5 day flight, good image quality and stability was achieved
during 33 hours, containing 45 sequences that lasted between 10 and 45 minutes.