Normalized to: Geraci, A.
[1]
oai:arXiv.org:1808.00540 [pdf] - 1918816
Searching for ultra-light dark matter with optical cavities
Submitted: 2018-08-01, last modified: 2018-08-08
We discuss the use of optical cavities as tools to search for dark matter
(DM) composed of virialized ultra-light fields (VULFs). Such fields could lead
to oscillating fundamental constants, resulting in oscillations of the length
of rigid bodies. We propose searching for these effects via differential strain
measurement of rigid and suspended-mirror cavities. We estimate that more than
two orders of magnitude of unexplored phase space for VULF DM couplings can be
probed at VULF Compton frequencies in the audible range of 0.1-10 kHz.
[2]
oai:arXiv.org:1710.08102 [pdf] - 1590122
A method for controlling the magnetic field near a superconducting
boundary in the ARIADNE axion experiment
Fosbinder-Elkins, H.;
Dargert, J.;
Harkness, M.;
Geraci, A. A.;
Levenson-Falk, E.;
Mumford, S.;
Kapitulnik, A.;
Shin, Y.;
Semertzidis, Y.;
Lee, Y. -H.
Submitted: 2017-10-23
The QCD Axion is a particle postulated to exist since the 1970s to explain
the Strong-CP problem in particle physics. It could also account for all of the
observed Dark Matter in the universe. The Axion Resonant InterAction DetectioN
Experiment (ARIADNE) experiment intends to detect the QCD axion by sensing the
fictitious "magnetic field" created by its coupling to spin. The experiment
must be sensitive to magnetic fields below the $10^{-19}$ T level to achieve
its design sensitivity, necessitating tight control of the experiment's
magnetic environment. We describe a method for controlling three aspects of
that environment which would otherwise limit the experimental sensitivity.
Firstly, a system of superconducting magnetic shielding is described to screen
ordinary magnetic noise from the sample volume at the $10^8$ level. Secondly, a
method for reducing magnetic field gradients within the sample up to $10^2$
times is described, using a simple and cost-effective design geometry. Thirdly,
a novel coil design is introduced which allows the generation of fields similar
to those produced by Helmholtz coils in regions directly abutting
superconducting boundaries. The methods may be generally useful for magnetic
field control near superconducting boundaries in other experiments where
similar considerations apply.
[3]
oai:arXiv.org:1710.05413 [pdf] - 1589746
Progress on the ARIADNE axion experiment
Geraci, A. A.;
Fosbinder-Elkins, H.;
Lohmeyer, C.;
Dargert, J.;
Cunningham, M.;
Harkness, M.;
Levenson-Falk, E.;
Mumford, S.;
Kapitulnik, A.;
Arvanitaki, A.;
Lee, I.;
Smith, E.;
Wiesman, E.;
Shortino, J.;
Long, J. C.;
Snow, W. M.;
Liu, C. -Y.;
Shin, Y.;
Semertzidis, Y.;
Lee, Y. -H.
Submitted: 2017-10-15
The Axion Resonant InterAction Detection Experiment (ARIADNE) is a
collaborative effort to search for the QCD axion using techniques based on
nuclear magnetic resonance. In the experiment, axions or axion-like particles
would mediate short-range spin-dependent interactions between a laser-polarized
3He gas and a rotating (unpolarized) tungsten source mass, acting as a tiny,
fictitious "magnetic field". The experiment has the potential to probe deep
within the theoretically interesting regime for the QCD axion in the mass range
of 0.1-10 meV, independently of cosmological assumptions. The experiment relies
on a stable rotary mechanism and superconducting magnetic shielding, required
to screen the 3He sample from ordinary magnetic noise. Progress on testing the
stability of the rotary mechanism is reported, and the design for the
superconducting shielding is discussed.
[5]
oai:arXiv.org:1605.04048 [pdf] - 1530695
Sensitivity of atom interferometry to ultralight scalar field dark
matter
Submitted: 2016-05-13, last modified: 2016-09-24
We discuss the use of atom interferometry as a tool to search for Dark Matter
(DM) composed of ultra-light scalar fields. Previous work on ultra-light DM
detection using accelerometers has considered the possibility of equivalence
principle violating effects whereby gradients in the dark matter field can
directly produce relative accelerations between media of differing composition.
In atom interferometers, we find that time-varying phase signals from
oscillatory, or dilaton-like, DM can also arise due to changes in the atom rest
mass that can occur between light-pulses throughout the interferometer sequence
as well as changes in the earth's gravitational field. We estimate that several
orders of magnitude of unexplored phase space for light DM fields can be probed
with our proposed method.
[6]
oai:arXiv.org:1207.5320 [pdf] - 1125024
Detecting high-frequency gravitational waves with optically-levitated
sensors
Submitted: 2012-07-23, last modified: 2013-01-02
We propose a tunable resonant sensor to detect gravitational waves in the
frequency range of 50-300 kHz using optically trapped and cooled dielectric
microspheres or micro-discs. The technique we describe can exceed the
sensitivity of laser-based gravitational wave observatories in this frequency
range, using an instrument of only a few percent of their size. Such a device
extends the search volume for gravitational wave sources above 100 kHz by 1 to
3 orders of magnitude, and could detect monochromatic gravitational radiation
from the annihilation of QCD axions in the cloud they form around stellar mass
black holes within our galaxy due to the superradiance effect.
[7]
oai:arXiv.org:0802.2350 [pdf] - 10161
Improved constraints on non-Newtonian forces at 10 microns
Submitted: 2008-02-16, last modified: 2008-06-29
Several recent theories suggest that light moduli or particles in "large"
extra dimensions could mediate macroscopic forces exceeding gravitational
strength at length scales below a millimeter. Such new forces can be
parameterized as a Yukawa-type correction to the Newtonian potential of
strength $\alpha$ relative to gravity and range $\lambda$. To extend the search
for such new physics we have improved our apparatus utilizing cryogenic
micro-cantilevers capable of measuring attonewton forces, which now includes a
switchable magnetic force for calibration. Our most recent experimental
constraints on Yukawa-type deviations from Newtonian gravity are more than
three times as stringent as our previously published results, and represent the
best bound in the range of 5 - 15 microns, with a 95 percent confidence
exclusion of forces with $|\alpha| > 14,000$ at $\lambda$ = 10 microns.