Normalized to: Gendotti, A.
[1]
oai:arXiv.org:2004.02024 [pdf] - 2075899
SiPM-matrix readout of two-phase argon detectors using
electroluminescence in the visible and near infrared range
The DarkSide collaboration;
Aalseth, C. E.;
Abdelhakim, S.;
Agnes, P.;
Ajaj, R.;
Albuquerque, I. F. M.;
Alexander, T.;
Alici, A.;
Alton, A. K.;
Amaudruz, P.;
Ameli, F.;
Anstey, J.;
Antonioli, P.;
Arba, M.;
Arcelli, S.;
Ardito, R.;
Arnquist, I. J.;
Arpaia, P.;
Asner, D. M.;
Asunskis, A.;
Ave, M.;
Back, H. O.;
Barbaryan, V.;
Olmedo, A. Barrado;
Batignani, G.;
Bisogni, M. G.;
Bocci, V.;
Bondar, A.;
Bonfini, G.;
Bonivento, W.;
Borisova, E.;
Bottino, B.;
Boulay, M. G.;
Bunker, R.;
Bussino, S.;
Buzulutskov, A.;
Cadeddu, M.;
Cadoni, M.;
Caminata, A.;
Canci, N.;
Candela, A.;
Cantini, C.;
Caravati, M.;
Cariello, M.;
Carnesecchi, F.;
Castellani, A.;
Castello, P.;
Cavalcante, P.;
Cavazza, D.;
Cavuoti, S.;
Cebrian, S.;
Ruiz, J. M. Cela;
Celano, B.;
Cereseto, R.;
Chashin, S.;
Cheng, W.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Citterio, M.;
Coccetti, F.;
Cocco, V.;
Colocci, M.;
Vidal, E. Conde;
Consiglio, L.;
Cossio, F.;
Covone, G.;
Crivelli, P.;
D'Antone, I.;
D'Incecco, M.;
Rolo, M. D. Da Rocha;
Dadoun, O.;
Daniel, M.;
Davini, S.;
De Cecco, S.;
De Deo, M.;
De Falco, A.;
De Gruttola, D.;
De Guido, G.;
De Rosa, G.;
Dellacasa, G.;
Demontis, P.;
De Pasquale, S.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Noto, L.;
Di Pietro, G.;
Di Stefano, P.;
Dionisi, C.;
Dolganov, G.;
Dordei, F.;
Downing, M.;
Edalatfar, F.;
Empl, A.;
Diaz, M. Fernandez;
Filip, C.;
Fiorillo, G.;
Fomenko, K.;
Franceschi, A.;
Franco, D.;
Frolov, E.;
Froudakis, G. E.;
Funicello, N.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Garbini, M.;
Abia, P. Garcia;
Fora, D. Gascón;
Gendotti, A.;
Ghiano, C.;
Ghisi, A.;
Giampa, P.;
Giampaolo, R. A.;
Giganti, C.;
Giorgi, M. A.;
Giovanetti, G. K.;
Gligan, M. L.;
Gorchakov, O.;
Grab, M.;
Diaz, R. Graciani;
Grassi, M.;
Grate, J. W.;
Grobov, A.;
Gromov, M.;
Guan, M.;
Guerra, M. B. B.;
Guerzoni, M.;
Gulino, M.;
Haaland, R. K.;
Hackett, B. R.;
Hallin, A.;
Haranczyk, M.;
Harrop, B.;
Hoppe, E. W.;
Horikawa, S.;
Hosseini, B.;
Hubaut, F.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ilyasov, A.;
Ippolito, V.;
Jillings, C.;
Keeter, K.;
Kendziora, C. L.;
Kochanek, I.;
Kondo, K.;
Kopp, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kugathasan, R.;
Kuss, M.;
La Commara, M.;
La Delfa, L.;
Lai, M.;
Lebois, M.;
Lehnert, B.;
Levashko, N.;
Li, X.;
Liqiang, Q.;
Lissia, M.;
Lodi, G. U.;
Longo, G.;
Lussana, R.;
Luzzi, L.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Manecki, S.;
Mapelli, L.;
Margotti, A.;
Mari, S. M.;
Mariani, M.;
Maricic, J.;
Marinelli, M.;
Marras, D.;
Martínez, M.;
Rojas, A. D. Martinez;
Mascia, M.;
Mason, J.;
Masoni, A.;
McDonald, A. B.;
Messina, A.;
Miletic, T.;
Milincic, R.;
Moggi, A.;
Moioli, S.;
Monroe, J.;
Morrocchi, M.;
Mroz, T.;
Mu, W.;
Muratova, V. N.;
Murphy, S.;
Muscas, C.;
Musico, P.;
Nania, R.;
Napolitano, T.;
Agasson, A. Navrer;
Nessi, M.;
Nikulin, I.;
Nosov, V.;
Nowak, J. A.;
Oleinik, A.;
Oleynikov, V.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Palmas, S.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Pazzona, F.;
Peeters, S.;
Pegoraro, P. A.;
Pelczar, K.;
Pellegrini, L. A.;
Pellegrino, C.;
Pelliccia, N.;
Perotti, F.;
Pesudo, V.;
Picciau, E.;
Pietropaolo, F.;
Pocar, A.;
Pollmann, T. R.;
Portaluppi, D.;
Poudel, S. S.;
Pralavorio, P.;
Price, D.;
Radics, B.;
Raffaelli, F.;
Ragusa, F.;
Razeti, M.;
Regenfus, C.;
Renshaw, A. L.;
Rescia, S.;
Rescigno, M.;
Retiere, F.;
Rignanese, L. P.;
Ripoli, C.;
Rivetti, A.;
Rode, J.;
Romani, A.;
Romero, L.;
Rossi, N.;
Rubbia, A.;
Sala, P.;
Salatino, P.;
Samoylov, O.;
García, E. Sánchez;
Sandford, E.;
Sanfilippo, S.;
Sant, M.;
Santone, D.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Scioli, G.;
Segreto, E.;
Seifert, A.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Siddhanta, S.;
Simeone, M.;
Singh, P. N.;
Skensved, P.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sobrero, G.;
Sokolov, A.;
Sotnikov, A.;
Stainforth, R.;
Steri, A.;
Stracka, S.;
Strickland, V.;
Suffritti, G. B.;
Sulis, S.;
Suvorov, Y.;
Szelc, A. M.;
Tartaglia, R.;
Testera, G.;
Thorpe, T.;
Tonazzo, A.;
Tosi, A.;
Tuveri, M.;
Unzhakov, E. V.;
Usai, G.;
Vacca, A.;
Vázquez-Jáuregui, E.;
Viant, T.;
Viel, S.;
Villa, F.;
Vishneva, A.;
Vogelaar, R. B.;
Wahl, J.;
Walding, J. J.;
Wang, H.;
Wang, Y.;
Westerdale, S.;
Wheadon, R. J.;
Williams, R.;
Wilson, J.;
Wojcik, Marcin;
Wojcik, Mariusz;
Wu, S.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zuffa, M.;
Zuzel, G.
Submitted: 2020-04-04
Proportional electroluminescence (EL) in noble gases is used in two-phase
detectors for dark matter search to record (in the gas phase) the ionization
signal induced by particle scattering in the liquid phase. The "standard" EL
mechanism is considered to be due to noble gas excimer emission in the vacuum
ultraviolet (VUV). In addition to it, there are two alternative mechanisms,
producing light in the visible and near infrared (NIR) range. The first is due
to bremsstrahlung of electrons scattered on neutral atoms (so-called neutral
bremsstrahlung, NBrS). The second, responsible for electron avalanche
scintillations in the NIR at higher electric fields, is due to transitions
between excited atomic states. In this work, we have for the first time
demonstrated two alternative techniques of the optical readout of two-phase
argon detectors, in the visible and NIR range, using a SiPM matrix and
electroluminescence due to either neutral bremsstrahlung or avalanche
scintillations effects. The amplitude yield and position resolution were
measured for these readout techniques, which allowed to assess the detection
threshold for electron and nuclear recoils in two-phase argon detectors for
dark matter search. It should be emphasized that this is the first practical
application of the NBrS effect in detection science.
[2]
oai:arXiv.org:2001.08106 [pdf] - 2080977
Design and construction of a new detector to measure ultra-low
radioactive-isotope contamination of argon
The DarkSide Collaboration;
Aalseth, C. E.;
Abdelhakim, S.;
Acerbi, F.;
Agnes, P.;
Ajaj, R.;
Albuquerque, I. F. M.;
Alexander, T.;
Alici, A.;
Alton, A. K.;
Amaudruz, P.;
Ameli, F.;
Anstey, J.;
Antonioli, P.;
Arba, M.;
Arcelli, S.;
Ardito, R.;
Arnquist, I. J.;
Arpaia, P.;
Asner, D. M.;
Asunskis, A.;
Ave, M.;
Back, H. O.;
Olmedo, A. Barrado;
Batignani, G.;
Bisogni, M. G.;
Bocci, V.;
Bondar, A.;
Bonfini, G.;
Bonivento, W.;
Borisova, E.;
Bottino, B.;
Boulay, M. G.;
Bunker, R.;
Bussino, S.;
Buzulutskov, A.;
Cadeddu, M.;
Cadoni, M.;
Caminata, A.;
Canci, N.;
Candela, A.;
Cantini, C.;
Caravati, M.;
Cariello, M.;
Carnesecchi, F.;
Carpinelli, M.;
Castellani, A.;
Castello, P.;
Catalanotti, S.;
Cataudella, V.;
Cavalcante, P.;
Cavazza, D.;
Cavuoti, S.;
Cebrian, S.;
Ruiz, J. M. Cela;
Celano, B.;
Cereseto, R.;
Cheng, W.;
Chepurnov, A.;
Cicalò, C.;
Cifarelli, L.;
Citterio, M.;
Cocco, A. G.;
Cocco, V.;
Colocci, M.;
Consiglio, L.;
Cossio, F.;
Covone, G.;
Crivelli, P.;
D'Antone, I.;
D'Incecco, M.;
D'Urso, D.;
Rolo, M. D. Da Rocha;
Dadoun, O.;
Daniel, M.;
Davini, S.;
De Candia, A.;
De Cecco, S.;
De Deo, M.;
De Falco, A.;
De Filippis, G.;
De Gruttola, D.;
De Guido, G.;
De Rosa, G.;
Dellacasa, G.;
Demontis, P.;
DePaquale, S.;
Derbin, A. V.;
Devoto, A.;
Di Eusanio, F.;
Di Noto, L.;
Di Pietro, G.;
Di Stefano, P.;
Dionisi, C.;
Dolganov, G.;
Dordei, F.;
Downing, M.;
Edalatfar, F.;
Empl, A.;
Diaz, M. Fernandez;
Ferri, A.;
Filip, C.;
Fiorillo, G.;
Fomenko, K.;
Franceschi, A.;
Franco, D.;
Froudakis, G. E.;
Gabriele, F.;
Gabrieli, A.;
Galbiati, C.;
Abia, P. Garcia;
Fora, D. Gascón;
Gendotti, A.;
Ghiano, C.;
Ghisi, A.;
Giagu, S.;
Giampa, P.;
Giampaolo, R. A.;
Giganti, C.;
Giorgi, M. A.;
Giovanetti, G. K.;
Gligan, M. L.;
Gola, A.;
Gorchakov, O.;
Grab, M.;
Diaz, R. Graciani;
Granato, F.;
Grassi, M.;
Grate, J. W.;
Grigoriev, G. Y.;
Grobov, A.;
Gromov, M.;
Guan, M.;
Guerra, M. B. B.;
Guerzoni, M.;
Gulino, M.;
Haaland, R. K.;
Hackett, B. R.;
Hallin, A.;
Harrop, B.;
Hoppe, E. W.;
Horikawa, S.;
Hosseini, B.;
Hubaut, F.;
Humble, P.;
Hungerford, E. V.;
Ianni, An.;
Ilyasov, A.;
Ippolito, V.;
Jillings, C.;
Keeter, K.;
Kendziora, C. L.;
Kim, S.;
Kochanek, I.;
Kondo, K.;
Kopp, G.;
Korablev, D.;
Korga, G.;
Kubankin, A.;
Kugathasan, R.;
Kuss, M.;
Kuźniak, M.;
La Commara, M.;
La Delfa, L.;
Lai, M.;
Langrock, S.;
Lebois, M.;
Lehnert, B.;
Levashko, N.;
Li, X.;
Liqiang, Q.;
Lissia, M.;
Lodi, G. U.;
Longo, G.;
Manzano, R. López;
Lussana, R.;
Luzzi, L.;
Machado, A. A.;
Machulin, I. N.;
Mandarano, A.;
Mapelli, L.;
Marcante, M.;
Margotti, A.;
Mari, S. M.;
Mariani, M.;
Maricic, J.;
Marinelli, M.;
Marras, D.;
Martínez, M.;
Morales, J. J. Martínez;
Rojas, A. D. Martinez;
Martoff, C. J.;
Mascia, M.;
Mason, J.;
Masoni, A.;
Mazzi, A.;
McDonald, A. B.;
Messina, A.;
Meyers, P. D.;
Miletic, T.;
Milincic, R.;
Moggi, A.;
Moioli, S.;
Monroe, J.;
Morrocchi, M.;
Mroz, T.;
Mu, W.;
Muratova, V. N.;
Murphy, S.;
Muscas, C.;
Musico, P.;
Nania, R.;
Napolitano, T.;
Agasson, A. Navrer;
Nessi, M.;
Nikulin, I.;
Oleinik, A.;
Oleynikov, V.;
Orsini, M.;
Ortica, F.;
Pagani, L.;
Pallavicini, M.;
Palmas, S.;
Pandola, L.;
Pantic, E.;
Paoloni, E.;
Paternoster, G.;
Pavletcov, V.;
Pazzona, F.;
Peeters, S.;
Pegoraro, P. A.;
Pelczar, K.;
Pellegrini, L. A.;
Pellegrino, C.;
Pelliccia, N.;
Perotti, F.;
Pesudo, V.;
Picciau, E.;
Piemonte, C.;
Pietropaolo, F.;
Pocar, A.;
Pollman, T.;
Portaluppi, D.;
Poudel, S. S.;
Pralavorio, P.;
Price, D.;
Radics, B.;
Raffaelli, F.;
Ragusa, F.;
Razeti, M.;
Razeto, A.;
Regazzoni, V.;
Regenfus, C.;
Renshaw, A. L.;
Rescia, S.;
Rescigno, M.;
Retiere, F.;
Rignanese, L. P.;
Rivetti, A.;
Romani, A.;
Romero, L.;
Rossi, N.;
Rubbia, A.;
Sablone, D.;
Sala, P.;
Salatino, P.;
Samoylov, O.;
García, E. Sánchez;
Sanfilippo, S.;
Sant, M.;
Santone, D.;
Santorelli, R.;
Savarese, C.;
Scapparone, E.;
Schlitzer, B.;
Scioli, G.;
Segreto, E.;
Seifert, A.;
Semenov, D. A.;
Shchagin, A.;
Sheshukov, A.;
Siddhanta, S.;
Simeone, M.;
Singh, P. N.;
Skensved, P.;
Skorokhvatov, M. D.;
Smirnov, O.;
Sobrero, G.;
Sokolov, A.;
Sotnikov, A.;
Stainforth, R.;
Steri, A.;
Stracka, S.;
Strickland, V.;
Suffritti, G. B.;
Sulis, S.;
Suvorov, Y.;
Szelc, A. M.;
Tartaglia, R.;
Testera, G.;
Thorpe, T.;
Tonazzo, A.;
Tosi, A.;
Tuveri, M.;
Unzhakov, E. V.;
Usai, G.;
Vacca, A.;
Vázquez-Jáuregui, E.;
Verducci, M.;
Viant, T.;
Viel, S.;
Villa, F.;
Vishneva, A.;
Vogelaar, R. B.;
Wada, M.;
Wahl, J.;
Walding, J. J.;
Wang, H.;
Wang, Y.;
Westerdale, S.;
Wheadon, R. J.;
Williams, R.;
Wilson, J.;
Wojcik, Marcin;
Wojcik, Mariusz;
Wu, S.;
Xiao, X.;
Yang, C.;
Ye, Z.;
Zuffa, M.;
Zuzel, G.
Submitted: 2020-01-22
Large liquid argon detectors offer one of the best avenues for the detection
of galactic weakly interacting massive particles (WIMPs) via their scattering
on atomic nuclei. The liquid argon target allows exquisite discrimination
between nuclear and electron recoil signals via pulse-shape discrimination of
the scintillation signals. Atmospheric argon (AAr), however, has a naturally
occurring radioactive isotope, $^{39}$Ar, a $\beta$ emitter of cosmogenic
origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up
concerns. The use of argon extracted from underground wells, deprived of
$^{39}$Ar, is key to the physics potential of these experiments. The
DarkSide-20k dark matter search experiment will operate a dual-phase time
projection chamber with 50 tonnes of radio-pure underground argon (UAr), that
was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger
than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is
crucial for the success of DarkSide-20k, as well as for future experiments of
the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by
the DArT in ArDM experiment, a small chamber made with extremely radio-pure
materials that will be placed at the centre of the ArDM detector, in the
Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an
active veto for background radioactivity, mostly $\gamma$-rays from the ArDM
detector materials and the surrounding rock. This article describes the DArT in
ArDM project, including the chamber design and construction, and reviews the
background required to achieve the expected performance of the detector.
[3]
oai:arXiv.org:1712.01932 [pdf] - 1799803
Backgrounds and pulse shape discrimination in the ArDM liquid argon TPC
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
Di Luise, S.;
Gendotti, A.;
Horikawa, S.;
Molina-Bueno, L.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Nguyen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2017-12-02
The ArDM experiment completed a single-phase commissioning run in 2015 with
an active liquid argon target of nearly one tonne in mass. The analysis of the
data and comparison to simulations allowed for a test of the crucial detector
properties and confirmed the low background performance of the setup. The
statistical rejection power for electron recoil events using the pulse shape
discrimination method was estimated using data from a Cf-252 neutron
calibration source. Electron and nuclear recoil band profiles were found to be
well described by Gaussian distributions. Employing such a model we derive
values for the electron recoil statistical rejection power of more than 10$^8$
in the tonne-scale liquid argon target for events with more than 50 detected
photons at a 50% acceptance for nuclear recoils. The Rn-222 emanation rate of
the ArDM cryostat at room temperature was found to be 65.6$\pm$0.4 $\mu$Hz/l,
and the Ar-39 specific activity from the employed atmospheric argon to be
0.95$\pm$0.05 Bq/kg. The cosmic muon flux at the Canfranc underground site was
determined to be between 2 and 3.5$\times 10^{-3}m^{2}s^{-1}$ . These results
pave the way for the next physics run of ArDM in the double-phase operational
mode.
[4]
oai:arXiv.org:1612.06375 [pdf] - 1551971
The ArDM Liquid Argon Time Projection Chamber at the Canfranc
Underground Laboratory: a ton-scale detector for Dark Matter Searches
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
DiLuise, S.;
Gendotti, A.;
Horikawa, S.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Ngyuen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2016-12-19
The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time
projection chamber (TPC) sensitive to nuclear recoils resulting from scattering
of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets.
With an active target of 850 kg, ArDM represents an important milestone in the
quest for Dark Matter with LAr. We present the experimental apparatus currently
installed underground at the Laboratorio Subterraneo de Canfranc (LSC), Spain.
We show first data recorded during a single-phase commissioning run in 2015
(ArDM Run I), which overall confirm the good and stable performance of the
ton-scale LAr detector.
[5]
oai:arXiv.org:1611.02481 [pdf] - 1510448
Measurement of the attenuation length of argon scintillation light in
the ArDM LAr TPC
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
DiLuise, S.;
Gendotti, A.;
Horikawa, S.;
Molina-Bueno, L.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Ngyuen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2016-11-08
We report on a measurement of the attenuation length for the scintillation
light in the tonne size liquid argon target of the ArDM dark matter experiment.
The data was recorded in the first underground operation of the experiment in
single-phase operational mode. The results were achieved by comparing the light
yield spectra from 39-Ar and 83m-Kr to a description of the ArDM setup with a
model of full light ray tracing. A relatively low value close to 0.5 m was
found for the attenuation length of the liquid argon bulk to its own
scintillation light. We interpret this result as a presence of optically active
impurities in the liquid argon which are not filtered by the installed
purification systems. We also present analyses of the argon gas employed for
the filling and discuss cross sections in the vacuum ultraviolet of various
molecules in respect to purity requirements in the context of large liquid
argon installations.
[6]
oai:arXiv.org:1505.02443 [pdf] - 996764
Status of ArDM-1t: First observations from operation with a full
ton-scale liquid argon target
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Daniel, M.;
Degunda, U.;
Di Luise, S.;
Epprecht, L.;
Gendotti, A.;
Horikawa, S.;
Knecht, L.;
Montes, B.;
Mu, W.;
Munoz, M.;
Murphy, S.;
Natterer, G.;
Nguyen, K.;
Nikolics, K.;
Periale, L.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Sgalaberna, D.;
Viant, T.;
Wu, S.
Submitted: 2015-05-10
ArDM-1t is the first operating ton-scale liquid argon detector for direct
search of Dark Matter particles. Developed at CERN as Recognized Experiment
RE18, the experiment has been approved in 2010 to be installed in the Spanish
underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of
LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical
completion and safety approval until the recent filling of the target vessel
with almost 2 ton of liquid argon. This report describes the experimental
achievements during commissioning of ArDM and the transition into a stage of
first physics data taking in single phase operational mode. We present
preliminary observations from this run. A first indication for the background
discrimination power of LAr detectors at the ton-scale is shown. We present an
outlook for completing the detector with the electric drift field and upgrade
of the scintillation light readout system with novel detector modules based on
SiPMs in order to improve the light yield.
[7]
oai:arXiv.org:1403.3573 [pdf] - 797027
FACT -- The G-APD revolution in Cherenkov astronomy
Bretz, T.;
Anderhub, H.;
Backes, M.;
Biland, A.;
Boccone, V.;
Braun, I.;
Buß, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hempfling, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. S.;
Knoetig, M. L.;
Köhne, J. H.;
Krähenbühl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Müuller, S.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
Röser, U.;
Stucki, J. P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Zänglein, M.
Submitted: 2014-03-14
Since two years, the FACT telescope is operating on the Canary Island of La
Palma. Apart from its purpose to serve as a monitoring facility for the
brightest TeV blazars, it was built as a major step to establish solid state
photon counters as detectors in Cherenkov astronomy. The camera of the First
G-APD Cherenkov Telesope comprises 1440 Geiger-mode avalanche photo diodes
(G-APD), equipped with solid light guides to increase the effective light
collection area of each sensor. Since no sense-line is available, a special
challenge is to keep the applied voltage stable although the current drawn by
the G-APD depends on the flux of night-sky background photons significantly
varying with ambient light conditions. Methods have been developed to keep the
temperature and voltage dependent response of the G-APDs stable during
operation. As a cross-check, dark count spectra with high statistics have been
taken under different environmental conditions. In this presentation, the
project, the developed methods and the experience from two years of operation
of the first G-APD based camera in Cherenkov astronomy under changing
environmental conditions will be presented.
[8]
oai:arXiv.org:1308.1512 [pdf] - 1934965
FACT - The First G-APD Cherenkov Telescope: Status and Results
Bretz, T.;
Anderhub, H.;
Backes, M.;
Biland, A.;
Boccone, V.;
Braun, I.;
Bretz, T.;
Buss, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. -S.;
Knoetig, M. L.;
Koehne, J. -H.;
Kraehenbuehl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
Roeser, U.;
Stucki, J. -P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Zaenglein, M.
Submitted: 2013-08-07
The First G-APD Cherenkov telescope (FACT) is the first telescope using
silicon photon detectors (G-APD aka. SiPM). It is built on the mount of the
HEGRA CT3 telescope, still located at the Observatorio del Roque de los
Muchachos, and it is successfully in operation since Oct. 2011. The use of
Silicon devices promises a higher photon detection efficiency, more robustness
and higher precision than photo-multiplier tubes. The FACT collaboration is
investigating with which precision these devices can be operated on the
long-term. Currently, the telescope is successfully operated from remote and
robotic operation is under development. During the past months of operation,
the foreseen monitoring program of the brightest known TeV blazars has been
carried out, and first physics results have been obtained including a strong
flare of Mrk501. An instantaneous flare alert system is already in a testing
phase. This presentation will give an overview of the project and summarize its
goals, status and first results.
[9]
oai:arXiv.org:1307.7892 [pdf] - 699793
FACT: Towards Robotic Operation of an Imaging Air Cherenkov Telescope
Biland, A.;
Anderhub, H.;
Backes, M.;
Boccone, V.;
Braun, I.;
Bretz, T.;
Buss, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. -S.;
Knoetig, M. L.;
Koehne, J. -H.;
Kraehenbuehl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
Roeser, U.;
Stucki, J. -P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Zaenglein, M.
Submitted: 2013-07-30
The First G-APD Cherenkov Telescope (FACT) became operational at La Palma in
October 2011. Since summer 2012, due to very smooth and stable operation, it is
the first telescope of its kind that is routinely operated from remote, without
the need for a data-taking crew on site. In addition, many standard tasks of
operation are executed automatically without the need for manual interaction.
Based on the experience gained so far, some alterations to improve the safety
of the system are under development to allow robotic operation in the future.
We present the setup and precautions used to implement remote operations and
the experience gained so far, as well as the work towards robotic operation.
[10]
oai:arXiv.org:1304.1710 [pdf] - 680263
Design and Operation of FACT -- The First G-APD Cherenkov Telescope
Anderhub, H.;
Backes, M.;
Biland, A.;
Boccone, V.;
Braun, I.;
Bretz, T.;
Buß, J.;
Cadoux, F.;
Commichau, V.;
Djambazov, L.;
Dorner, D.;
Einecke, S.;
Eisenacher, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Haller, C.;
Hildebrand, D.;
Horisberger, U.;
Huber, B.;
Kim, K. -S.;
Knoetig, M. L.;
K"ohne, J. H.;
Kr"ahenb"uhl, T.;
Krumm, B.;
Lee, M.;
Lorenz, E.;
Lustermann, W.;
Lyard, E.;
Mannheim, K.;
Meharga, M.;
Meier, K.;
Montaruli, T.;
Neise, D.;
Nessi-Tedaldi, F.;
Overkemping, A. -K.;
Paravac, A.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Ribordy, M.;
R"oser, U.;
Stucki, J. -P.;
Schneider, J.;
Steinbring, T.;
Temme, F.;
Thaele, J.;
Tobler, S.;
Viertel, G.;
Vogler, P.;
Walter, R.;
Warda, K.;
Weitzel, Q.;
Z"anglein, M.
Submitted: 2013-04-05
The First G-APD Cherenkov Telescope (FACT) is designed to detect cosmic
gamma-rays with energies from several hundred GeV up to about 10 TeV using the
Imaging Atmospheric Cherenkov Technique. In contrast to former or existing
telescopes, the camera of the FACT telescope is comprised of solid-state
Geiger-mode Avalanche Photodiodes (G-APD) instead of photomultiplier tubes for
photo detection. It is the first full-scale device of its kind employing this
new technology. The telescope is operated at the Observatorio del Roque de los
Muchachos (La Palma, Canary Islands, Spain) since fall 2011. This paper
describes in detail the design, construction and operation of the system,
including hardware and software aspects. Technical experiences gained after one
year of operation are discussed and conclusions with regard to future projects
are drawn.
[11]
oai:arXiv.org:1010.2397 [pdf] - 266353
FACT -- the First Cherenkov Telescope using a G-APD Camera for TeV
Gamma-ray Astronomy (HEAD 2010)
Anderhub, H.;
Backes, M.;
Biland, A.;
Boller, A.;
Braun, I.;
Bretz, T.;
Commichau, S.;
Commichau, V.;
Domke, M.;
Dorner, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Hildebrand, D.;
Horisberger, U.;
Köhne, J. -H.;
Krähenbühl, T.;
Kranich, D.;
Krumm, B.;
Lorenz, E.;
Lustermann, W.;
Mannheim, K.;
Neise, D.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Rissi, M.;
Ribordy, M.;
Röser, U.;
Stark, L. S.;
Stucki, J. -P.;
Tibolla, O.;
Viertel, G.;
Vogler, P.;
Warda, K.;
Weitzel, Q.
Submitted: 2010-10-12, last modified: 2010-11-22
Geiger-mode Avalanche Photodiodes (G-APD) bear the potential to significantly
improve the sensitivity of Imaging Air Cherenkov Telescopes (IACT). We are
currently building the First G-APD Cherenkov Telescope (FACT) by refurbishing
an old IACT with a mirror area of 9.5 square meters and construct a new, fine
pixelized camera using novel G-APDs. The main goal is to evaluate the
performance of a complete system by observing very high energy gamma-rays from
the Crab Nebula. This is an important field test to check the feasibility of
G-APD-based cameras to replace at some time the PMT-based cameras of planned
future IACTs like AGIS and CTA. In this article, we present the basic design of
such a camera as well as some important details to be taken into account.
[12]
oai:arXiv.org:1001.0077 [pdf] - 32338
The LAGUNA design study- towards giant liquid based underground
detectors for neutrino physics and astrophysics and proton decay searches
LAGUNA Collaboration;
Angus, D.;
Ariga, A.;
Autiero, D.;
Apostu, A.;
Badertscher, A.;
Bennet, T.;
Bertola, G.;
Bertola, P. F.;
Besida, O.;
Bettini, A.;
Booth, C.;
Borne, J. L.;
Brancus, I.;
Bujakowsky, W.;
Campagne, J. E.;
Danil, G. Cata;
Chipesiu, F.;
Chorowski, M.;
Cripps, J.;
Curioni, A.;
Davidson, S.;
Declais, Y.;
Drost, U.;
Duliu, O.;
Dumarchez, J.;
Enqvist, T.;
Ereditato, A.;
von Feilitzsch, F.;
Fynbo, H.;
Gamble, T.;
Galvanin, G.;
Gendotti, A.;
Gizicki, W.;
Goger-Neff, M.;
Grasslin, U.;
Gurney, D.;
Hakala, M.;
Hannestad, S.;
Haworth, M.;
Horikawa, S.;
Jipa, A.;
Juget, F.;
Kalliokoski, T.;
Katsanevas, S.;
Keen, M.;
Kisiel, J.;
Kreslo, I.;
Kudryastev, V.;
Kuusiniemi, P.;
Labarga, L.;
Lachenmaier, T.;
Lanfranchi, J. C.;
Lazanu, I.;
Lewke, T.;
Loo, K.;
Lightfoot, P.;
Lindner, M.;
Longhin, A.;
Maalampi, J.;
Marafini, M.;
Marchionni, A.;
Margineanu, R. M.;
Markiewicz, A.;
Marrodan-Undagoita, T.;
Marteau, J. E.;
Matikainen, R.;
Meindl, Q.;
Messina, M.;
Mietelski, J. W.;
Mitrica, B.;
Mordasini, A.;
Mosca, L.;
Moser, U.;
Nuijten, G.;
Oberauer, L.;
Oprina, A.;
Paling, S.;
Pascoli, S.;
Patzak, T.;
Pectu, M.;
Pilecki, Z.;
Piquemal, F.;
Potzel, W.;
Pytel, W.;
Raczynski, M.;
Rafflet, G.;
Ristaino, G.;
Robinson, M.;
Rogers, R.;
Roinisto, J.;
Romana, M.;
Rondio, E.;
Rossi, B.;
Rubbia, A.;
Sadecki, Z.;
Saenz, C.;
Saftoiu, A.;
Salmelainen, J.;
Sima, O.;
Slizowski, J.;
Slizowski, K.;
Sobczyk, J.;
Spooner, N.;
Stoica, S.;
Suhonen, J.;
Sulej, R.;
Szarska, M.;
Szeglowski, T.;
Temussi, M.;
Thompson, J.;
Thompson, L.;
Trzaska, W. H.;
Tippmann, M.;
Tonazzo, A.;
Urbanczyk, K.;
Vasseur, G.;
Williams, A.;
Winter, J.;
Wojutszewska, K.;
Wurm, M.;
Zalewska, A.;
Zampaolo, M.;
Zito, M.
Submitted: 2009-12-30
The feasibility of a next generation neutrino observatory in Europe is being
considered within the LAGUNA design study. To accommodate giant neutrino
detectors and shield them from cosmic rays, a new very large underground
infrastructure is required. Seven potential candidate sites in different parts
of Europe and at several distances from CERN are being studied: Boulby (UK),
Canfranc (Spain), Fr\'ejus (France/Italy), Pyh\"asalmi (Finland),
Polkowice-Sieroszowice (Poland), Slanic (Romania) and Umbria (Italy). The
design study aims at the comprehensive and coordinated technical assessment of
each site, at a coherent cost estimation, and at a prioritization of the sites
within the summer 2010.
[13]
oai:arXiv.org:0911.4920 [pdf] - 902541
A novel camera type for very high energy gamma-ray astronomy based on
Geiger-mode avalanche photodiodes
Anderhub, H.;
Backes, M.;
Biland, A.;
Boller, A.;
Braun, I.;
Bretz, T.;
Commichau, S.;
Commichau, V.;
Dorner, D.;
Gendotti, A.;
Grimm, O.;
von Gunten, H.;
Hildebrand, D.;
Horisberger, U.;
Krähenbühl, T.;
Kranich, D.;
Lorenz, E.;
Lustermann, W.;
Mannheim, K.;
Neise, D.;
Pauss, F.;
Renker, D.;
Rhode, W.;
Rissi, M.;
Röser, U.;
Rollke, S.;
Stark, L. S.;
Stucki, J. -P.;
Viertel, G.;
Vogler, P.;
Weitzel, Q.
Submitted: 2009-11-25
Geiger-mode avalanche photodiodes (G-APD) are promising new sensors for light
detection in atmospheric Cherenkov telescopes. In this paper, the design and
commissioning of a 36-pixel G-APD prototype camera is presented. The data
acquisition is based on the Domino Ring Sampling (DRS2) chip. A sub-nanosecond
time resolution has been achieved. Cosmic-ray induced air showers have been
recorded using an imaging mirror setup, in a self-triggered mode. This is the
first time that such measurements have been carried out with a complete G-APD
camera.