Gavrilyuk, Yu. M.
Normalized to: Gavrilyuk, Y.
3 article(s) in total. 18 co-authors, from 1 to 2 common article(s). Median position in authors list is 2,0.
[1]
oai:arXiv.org:1911.03773 [pdf] - 2065314
Gravitational wave detector OGRAN as multi-messenger project of RAS-MSU
Submitted: 2019-11-09
Modernized version of the combined opto-acoustical gravitational wave
detector OGRAN is presented. Located in the deep underground of the Baksan
Neutrino Observatory this setup is aimed to work on the program of collapsing
stars searching for in multi-channel manner with the neutrino telescope BUST.
The both instruments have the sensitivity allowing a registration of collapses
in our Galaxy as rare events with the estimated probability 0:03 year-1. The
OGRAN narrow band sensitivity at the kilohertz frequency is limited by its
acoustical mode thermal noise achieving 10^{-20} in term of metric
perturbations. A possible algorithm of the joint data analysis for the both
instruments is developed and resulting formulae of the right detection
probability are given. A future increasing of the OGRAN sensitivity associated
with the moderate cooling (nitrogen temperature) of the acoustical mode is also
discussed.
[2]
oai:arXiv.org:1512.05939 [pdf] - 1914607
Study of the characteristics of SiPMs matrix as a photosensor for the
scintillation detectors
Submitted: 2015-12-18
The matrices formed of silicon photomultipliers (SiPMs) are very promising
photosensors for the scintillation detectors. The use of SiPM matrices with
appropriate optical collector gives, in principle, a possibility to do a
snapshot of glowing track of charged particle traversing a scintillator. The
prototype of such scintillation detector is under development now in INR RAS.
The preliminary results of characterization study of the matrix
ArrayC-60035-64P-PCB (SensL company) for the prototype of such detector are
presented.
[3]
oai:arXiv.org:1505.01752 [pdf] - 1521139
Results of a search for daily and annual variations of the Po-214
half-life at the two year observation period
Submitted: 2015-05-07
The brief description of installation TAU-2 intended for long-term monitoring
of the half-life value $\tau$ ($\tau_{1/2}$) of the $^{214}$Po is presented.
The methods of measurement and processing of collected data are reported. The
results of analysis of time series values $\tau$ with different time step are
presented. Total of measurement time was equal to 590 days. Averaged value of
the $^{214}$Po half-life was obtained $\tau=163.46\pm0.04$ $\mu$s. The annual
variation with an amplitude $A=(8.9\pm2.3)\cdot10^{-4}$, solar-daily variation
with an amplitude $A_{So}=(7.5\pm1.2)\cdot10^{-4}$, lunar-daily variation with
an amplitude $A_L=(6.9\pm2.0)\cdot10^{-4}$ and sidereal-daily variation with an
amplitude $A_S=(7.2\pm1.2)\cdot10^{-4}$ were found in a series of $\tau$
values. The maximal values of amplitude are observed at the moments when the
projections of the installation Earth location velocity vectors toward the
source of possible variation achieve its maximal magnitudes.