Normalized to: Gauvreau, J.
[1]
oai:arXiv.org:1709.06219 [pdf] - 1648626
Study of Negative-Ion TPC Using {\mu}-PIC for Directional Dark Matter
Search
Ikeda, Tomonori;
Miuchi, Kentaro;
Ochi, Atsuhiko;
Yakabe, Ryota;
Hashimoto, Takashi;
Taishaku, Ryosuke;
Snowden-Ifft, Daniel P.;
Gauvreau, Jean-Luc;
Tanimori, Toru;
Takada, Atsushi;
Nakamura, Kiseki
Submitted: 2017-09-18
Negative-ion time projection chambers(TPCs) have been studied for low-rate
and high-resolution applications such as dark matter search experiments.
Recently, a full volume fiducialization in a self-triggering TPC was realized.
This innovative technology demonstrated a significant reduction in the
background with MWPC-TPCs. We studied negative-ion TPC using the {\mu}-PIC+GEM
system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at
low pressures. We expect an improvement in detector sensitivity and angular
resolution with better electronics.
[2]
oai:arXiv.org:1707.09431 [pdf] - 1586535
Measurement of directional range components of nuclear recoil tracks in
a fiducialised dark matter detector
Battat, J. B. R.;
Daw, E. J.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Lee, E. R.;
Loomba, D.;
Lynch, W.;
Miller, E. H.;
Mouton, F.;
Paling, S.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.
Submitted: 2017-07-28
We present results from the first measurement of axial range components of
fiducialized neutron induced nuclear recoil tracks using the DRIFT directional
dark matter detector. Nuclear recoil events are fiducialized in the DRIFT
experiment using temporal charge carrier separations between different species
of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this
measurement, neutron-induced nuclear recoil tracks were generated by exposing
the detector to $^{252}$Cf source from different directions. Using these
events, the sensitivity of the detector to the expected axial directional
signatures were investigated as the neutron source was moved from one detector
axis to another. Results obtained from these measurements show clear
sensitivity of the DRIFT detector to the axial directional signatures in this
fiducialization gas mode.
[3]
oai:arXiv.org:1701.00171 [pdf] - 1564000
Low Threshold Results and Limits from the DRIFT Directional Dark Matter
Detector
Battat, J. B. R.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Paling, S. M.;
Phan, N. S.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Waldram, N.
Submitted: 2016-12-31, last modified: 2017-03-27
We present results from a 54.7 live-day shielded run of the DRIFT-IId
detector, the world's most sensitive, directional, dark matter detector.
Several improvements were made relative to our previous work including a lower
threshold for detection, a more robust analysis and a tenfold improvement in
our gamma rejection factor. After analysis, no events remain in our fiducial
region leading to an exclusion curve for spin-dependent WIMP-proton
interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our
previous work. We also present results from a 45.4 live-day unshielded run of
the DRIFT-IId detector during which 14 nuclear recoil-like events were
observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08
events per day is consistent with detection of ambient, fast neutrons emanating
from the walls of the Boulby Underground Science Facility.
[4]
oai:arXiv.org:1410.7821 [pdf] - 1250420
First background-free limit from a directional dark matter experiment:
results from a fully fiducialised DRIFT detector
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Gold, M.;
Harton, J. L.;
Landers, J. M.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Vahsen, S. E.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-10-28, last modified: 2015-07-23
The addition of O2 to gas mixtures in time projection chambers containing CS2
has recently been shown to produce multiple negative ions that travel at
slightly different velocities. This allows a measurement of the absolute
position of ionising events in the z (drift) direction. In this work, we apply
the z-fiducialisation technique to a directional dark matter search. In
particular, we present results from a 46.3 live-day source-free exposure of the
DRIFT-IId detector run in this completely new mode. With full-volume
fiducialisation, we have achieved the first background-free operation of a
directional detector. The resulting exclusion curve for spin-dependent
WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better
than our previous work. We describe the automated analysis used here, and argue
that detector upgrades, implemented after the acquisition of these data, will
bring an additional factor of >3 improvement in the near future.
[5]
oai:arXiv.org:1407.3938 [pdf] - 1215675
Radon in the DRIFT-II directional dark matter TPC: emanation, detection
and mitigation
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Fox, J. R.;
Gauvreau, J. -L.;
Gold, M.;
Harmon, L. J.;
Harton, J. L.;
Landers, J. M.;
Lee, E. R.;
Loomba, D.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Pipe, M.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-07-15, last modified: 2014-08-25
Radon gas emanating from materials is of interest in environmental science
and also a major concern in rare event non-accelerator particle physics
experiments such as dark matter and double beta decay searches, where it is a
major source of background. Notable for dark matter experiments is the
production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils
of radon daughter isotopes, which can mimic the signal expected from WIMP
interactions. Presented here are results of measurements of radon emanation
from detector materials in the 1 metre cubed DRIFT-II directional dark matter
gas time projection chamber experiment. Construction and operation of a radon
emanation facility for this work is described, along with an analysis to
continuously monitor DRIFT data for the presence of internal 222Rn and 218Po.
Applying this analysis to historical DRIFT data, we show how systematic
substitution of detector materials for alternatives, selected by this device
for low radon emanation, has resulted in a factor of ~10 reduction in internal
radon rates. Levels are found to be consistent with the sum from separate radon
emanation measurements of the internal materials and also with direct
measurement using an attached alpha spectrometer. The current DRIFT detector,
DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 {\mu}Bq/l with current
analysis efficiency, potentially opening up DRIFT technology as a new tool for
sensitive radon assay of materials.
[6]
oai:arXiv.org:1404.2253 [pdf] - 934775
Background Assay and Rejection in DRIFT
Brack, Jeff;
Daw, Ed;
Dorofeev, Alexei;
Ezeribe, Anthony;
Gauvreau, Jean-Luc;
Gold, Michael;
Harton, John;
Lafler, Randy;
Lauer, Robert;
Lee, Eric R.;
Loomba, Dinesh;
Matthews, John;
Miller, Eric H.;
Monte, Alissa;
Murphy, Alex;
Paling, Sean;
Phan, Nguyen;
Sadler, Steve;
Scarff, Andrew;
Snowden-Ifft, Daniel;
Spooner, Neil;
Telfer, Sam;
Walker, Daniel;
Williams, Matt;
Yuriev, Leonid
Submitted: 2014-04-08
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with
directional sensitivity to WIMP-induced nuclear recoils. Its primary
backgrounds were due to alpha decays from contamination on the central cathode.
Efforts to reduce these backgrounds led to replacing the 20 \mu m wire central
cathode with one constructed from 0.9 \mu m aluminized mylar, which is almost
totally transparent to alpha particles. Detailed modeling of the nature and
origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of
alpha decay backgrounds from the central cathode. This led to further
improvements in the thin-film cathode resulting in over 2 orders of magnitude
reduction in backgrounds compared to the wire cathode. Finally, the addition of
O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative
charge carriers, providing a method to determine the absolute position of
nuclear recoils and reject all known remaining backgrounds while retaining a
high efficiency for nuclear recoil detection.
[7]
oai:arXiv.org:1301.7145 [pdf] - 1159372
High Precision Measurements of Carbon Disulfide Negative Ion Mobility
and Diffusion
Submitted: 2013-01-30, last modified: 2013-12-12
High precision measurements were made of reduced mobility, lateral and
longitudinal diffusion of CS2- negative ions in 40 Torr CS2 and a 30 - 10 Torr
CS2 - CF4 gas mixture. The reduced mobility was found to be 353.0 +/- 0.5 cm^2
Torr / s V in CS2 and 397.4 +/- 0.7 cm^2 Torr / s V in the CS2 - CF4 gas
mixture at STP. The lateral diffusion temperatures for these two gases (295 +/-
15 K and 297 +/- 6 K) were found to be in good agreement with room temperature.
By contrast longitudinal diffusion temperature was found to be slightly
elevated (319 +/- 10 (stat) +/- 8 (sys) K and 310 +/- 20 (stat) +/- 6 (sys) K)
though given the errors, room temperature diffusion can not be ruled out. For
lateral diffusion significant capture distances (0.21 +/- 0.07 mm and 0.15 +/-
0.03 mm) were measured while for longitudinal diffusion the results were not
conclusive.
[8]
oai:arXiv.org:1110.0222 [pdf] - 967108
The DRIFT Dark Matter Experiments
Daw, E.;
Dorofeev, A.;
Fox, J. R.;
Gauvreau, J. -L.;
Ghag, C.;
Harmon, L. J.;
Harton, J. L.;
Gold, M.;
Lee, E. R.;
Loomba, D.;
Miller, E. H.;
Murphy, A. St. J.;
Paling, S. M.;
Landers, J. M.;
Phan, N.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Sadler, S. W.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Walker, D.;
Warner, D.
Submitted: 2011-10-02
The current status of the DRIFT (Directional Recoil Identification From
Tracks) experiment at Boulby Mine is presented, including the latest limits on
the WIMP spin-dependent cross-section from 1.5 kg days of running with a
mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with
ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale
directional Dark Matter detector.
[9]
oai:arXiv.org:1010.3027 [pdf] - 345888
Spin-Dependent Limits from the DRIFT-IId Directional Dark Matter
Detector
Daw, E.;
Fox, J. R.;
Gauvreau, J. -L.;
Ghag, C.;
Harmon, L. J.;
Gold, M.;
Lee, E.;
Loomba, D.;
Miller, E.;
Murphy, A. StJ.;
Paling, S. M.;
Landers, J. M.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Walker, D.
Submitted: 2010-10-14, last modified: 2011-04-16
Data are presented from the DRIFT-IId detector housed in the Boulby mine in
northeast England. A 0.8 m^3 fiducial volume, containing partial pressures of
30 Torr CS2 and 10 Torr CF4, was exposed for a duration of 47.4 live-time days
with sufficient passive shielding to provide a neutron free environment within
the detector. The nuclear recoil events seen are consistent with a remaining
low level background from the decay of progeny of radon daughters attached to
the central cathode of the detector. However, energy depositions from such
events must drift across the entire width of the detector, and thus display
large diffusion upon reaching the readout planes of the device. Exploiting this
feature, it is shown to be possible to reject energy depositions from these
radon decay progeny events while still retaining sensitivity to nuclear recoil
events. The response of the detector is then interpreted, using the F nuclei
content of the gas, in terms of sensitivity to proton spin-dependent
WIMP-nucleon interactions, displaying a minimum in sensitivity cross section at
0.5 pb for a WIMP mass of 100 GeV/c^2.