Normalized to: Gauron, T.
[1]
oai:arXiv.org:1905.03320 [pdf] - 1898058
Binospec: A Wide-field Imaging Spectrograph for the MMT
Fabricant, Daniel;
Fata, Robert;
Epps, Harland;
Gauron, Thomas;
Mueller, Mark;
Zajac, Joseph;
Amato, Stephen;
Barberis, Jack;
Bergner, Henry;
Brennan, Patricia;
Brown, Warren;
Chilingarian, Igor;
Geary, John;
Kradinov, Vladimir;
McLeod, Brian;
Smith, Matthew;
Woods, Deborah
Submitted: 2019-05-08
Binospec is a high throughput, 370 to 1000 nm, imaging spectrograph that
addresses two adjacent 8' by 15' fields of view. Binospec was commissioned in
late 2017 at the f/5 focus of the 6.5m MMT and is now available to all MMT
observers. Aperture masks cut from stainless steel with a laser cutter are used
to define the entrance apertures that range from 15' long slits to hundreds of
2" slitlets. System throughputs, including the MMT's mirrors and the f/5
wide-field corrector peak at ~30%. Three reflection gratings, duplicated for
the two beams, provide resolutions ($\lambda$/$\Delta \lambda$) between 1300
and $>$5000 with a 1" wide slit. Two through-the-mask guiders are used for
target acquisition, mask alignment, guiding, and precision offsets. A full-time
Shack-Hartmann wave front sensor allows continuous adjustment of primary mirror
support forces, telescope collimation and focus. Active flexure control
maintains spectrograph alignment and focus under varying gravity and thermal
conditions.
[2]
oai:arXiv.org:0709.2719 [pdf] - 5059
Wide Field Hard X-ray Survey Telescope: ProtoEXIST1
Hong, J.;
Grindlay, J. E.;
Chammas, N.;
Allen, B.;
Copete, A.;
Said, B.;
Burke, M.;
Howell, J.;
Gauron, T.;
Baker, R. G.;
Barthelmy, S. D.;
Sheikh, S.;
Gehrels, N.;
Cook, W. R.;
Burnham, J. A.;
Harrison, F. A.;
Collins, J.;
Labov, S.;
Garson, A.;
Krawczynski, H.
Submitted: 2007-09-17
We report our progress on the development of pixellated imaging CZT detector
arrays for our first-generation balloon-borne wide-field hard X-ray (20 - 600
keV) telescope, ProtoEXIST1. Our ProtoEXIST program is a pathfinder for the
High Energy Telescope (HET) on the Energetic X-ray Imaging Survey telescope
(EXIST), a proposed implementation of the Black Hole Finder Probe. ProtoEXIST1
consists of four independent coded-aperture telescopes with close-tiled (~0.4
mm gaps) CZT detectors that preserve their 2.5mm pixel pitch. Multiple
shielding/field-of-view configurations are planned to identify optimal geometry
for the HET in EXIST. The primary technical challenge in ProtoEXIST is the
development of large area, close-tiled modules of imaging CZT detectors (1000
cm2 for ProtoEXIST1), with all readout and control systems for the ASIC readout
vertically stacked. We describe the overall telescope configuration of
ProtoEXIST1 and review the current development status of the CZT detectors,
from individual detector crystal units (DCUs) to a full detector module (DM).
We have built the first units of each component for the detector plane and have
completed a few Rev2 DCUs (2x2 cm2), which are under a series of tests. Bare
DCUs (pre-crystal bonding) show high, uniform ASIC yield (~70%) and ~30%
reduction in electronics noise compared to the Rev1 equivalent. A Rev1 DCU
already achieved ~1.2% FWHM at 662 keV, and preliminary analysis of the initial
radiation tests on a Rev2 DCU shows ~ 4 keV FWHM at 60 keV (vs. 4.7 keV for
Rev1). We therefore expect about <~1% FWHM at 662 keV with the Rev2 detectors.
[3]
oai:arXiv.org:astro-ph/0508554 [pdf] - 371776
Hectospec, the MMT's 300 Optical Fiber-Fed Spectrograph
Submitted: 2005-08-25
The Hectospec is a 300 optical fiber fed spectrograph commissioned at the MMT
in the spring of 2004. A pair of high-speed six-axis robots move the 300 fiber
buttons between observing configurations within ~300 s and to an accuracy ~25
microns. The optical fibers run for 26 m between the MMT's focal surface and
the bench spectrograph operating at R~1000-2000. Another high dispersion bench
spectrograph offering R~5,000, Hectochelle, is also available. The system
throughput, including all losses in the telescope optics, fibers, and
spectrograph peaks at ~10% at the grating blaze in 1" FWHM seeing. Correcting
for aperture losses at the 1.5" diameter fiber entrance aperture, the system
throughput peaks at $\sim$17%. Hectospec has proven to be a workhorse
instrument at the MMT. Hectospec and Hectochelle together were scheduled for
1/3 of the available nights since its commissioning. Hectospec has returned
\~60,000 reduced spectra for 16 scientific programs during its first year of
operation.