Normalized to: Gatti, F.
[1]
oai:arXiv.org:2005.01187 [pdf] - 2089273
Progress report on the Large Scale Polarization Explorer
Lamagna, L.;
Addamo, G.;
Ade, P. A. R.;
Baccigalupi, C.;
Baldini, A. M.;
Battaglia, P. M.;
Battistelli, E.;
Baù, A.;
Bersanelli, M.;
Biasotti, M.;
Boragno, C.;
Boscaleri, A.;
Caccianiga, B.;
Caprioli, S.;
Cavaliere, F.;
Cei, F.;
Cleary, K. A.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
Corsini, D.;
Cuttaia, F.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Petris, M.;
Del Torto, F.;
Fafone, V.;
Farooqui, Z.;
Farsian, F.;
Fontanelli, F.;
Franceschet, C.;
Gaier, T. C.;
Gatti, F.;
Genova-Santos, R.;
Gervasi, M.;
Ghigna, T.;
Grassi, M.;
Grosso, D.;
Gualtieri, R.;
Incardona, F.;
Jones, M.;
Kangaslahti, P.;
Krachmalnicoff, N.;
Mainini, R.;
Maino, D.;
Mandelli, S.;
Maris, M.;
Masi, S.;
Matarrese, S.;
May, A.;
Mena, P.;
Mennella, A.;
Molina, R.;
Molinari, D.;
Morgante, G.;
Nati, F.;
Natoli, P.;
Pagano, L.;
Paiella, A.;
Paonessa, F.;
Passerini, A.;
Perez-de-Taoro, M.;
Peverini, O. A.;
Pezzotta, F.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Polastri, L.;
Polenta, G.;
Poletti, D.;
Presta, G.;
Realini, S.;
Reyes, N.;
Rocchi, A.;
Rubiño-Martin, J. A.;
Sandri, M.;
Sartor, S.;
Schillaci, A.;
Signorelli, G.;
Siri, B.;
Soria, M.;
Spinella, F.;
Tapia, V.;
Tartari, A.;
Taylor, A.;
Terenzi, L.;
Tomasi, M.;
Tommasi, E.;
Tucker, C.;
Vaccaro, D.;
Vigano, D. M.;
Villa, F.;
Virone, G.;
Vittorio, N.;
Volpe, A.;
Watkins, B.;
Zacchei, A.;
Zannoni, M.
Submitted: 2020-05-03, last modified: 2020-05-05
The Large Scale Polarization Explorer (LSPE) is a cosmology program for the
measurement of large scale curl-like features (B-modes) in the polarization of
the Cosmic Microwave Background. Its goal is to constrain the background of
inflationary gravity waves traveling through the universe at the time of
matter-radiation decoupling. The two instruments of LSPE are meant to
synergically operate by covering a large portion of the northern microwave sky.
LSPE/STRIP is a coherent array of receivers planned to be operated from the
Teide Observatory in Tenerife, for the control and characterization of the
low-frequency polarized signals of galactic origin; LSPE/SWIPE is a
balloon-borne bolometric polarimeter based on 330 large throughput multi-moded
detectors, designed to measure the CMB polarization at 150 GHz and to monitor
the polarized emission by galactic dust above 200 GHz. The combined performance
and the expected level of systematics mitigation will allow LSPE to constrain
primordial B-modes down to a tensor/scalar ratio of $10^{-2}$. We here report
the status of the STRIP pre-commissioning phase and the progress in the
characterization of the key subsystems of the SWIPE payload (namely the
cryogenic polarization modulation unit and the multi-moded TES pixels) prior to
receiver integration.
[2]
oai:arXiv.org:1912.06390 [pdf] - 2014523
The Demonstration Model of the ATHENA X-IFU Cryogenic AntiCoincidence
Detector
D'Andrea, Matteo;
Macculi, Claudio;
Torrioli, Guido;
Argan, Andrea;
Brienza, Daniele;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Barusso, Lorenzo Ferrari;
Gatti, Flavio;
Rigano, Manuela;
Volpe, Angela;
Battistelli, Elia Stefano
Submitted: 2019-12-13
The Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU is designed
to reduce the particle background of the instrument and to enable the mission
science goals. It is a 4 pixel silicon microcalorimeter sensed by an Ir/Au TES
network. We have developed the CryoAC Demonstration Model, a prototype aimed to
probe the critical technologies of the detector, i.e. the suspended absorber
with an active area of 1 cm2; the low energy threshold of 20 keV; and the
operation connected to a 50 mK thermal bath with a power dissipation less than
40 nW. Here we report the test performed on the first CryoAC DM sample (namely
the AC-S10 prototype), showing that it is fully compliant with its
requirements.
[3]
oai:arXiv.org:1902.05508 [pdf] - 1970174
Neutrino physics with the PTOLEMY project: active neutrino properties
and the light sterile case
PTOLEMY collaboration;
Betti, M. G.;
Biasotti, M.;
Boscá, A.;
Calle, F.;
Cavoto, G.;
Chang, C.;
Cocco, A. G.;
Colijn, A. P.;
Conrad, J.;
D'Ambrosio, N.;
De Groot, N.;
de Salas, P. F.;
Faverzani, M.;
Ferella, A.;
Ferri, E.;
Garcia-Abia, P.;
García-Cortés, I.;
Gomez-Tejedor, G. Garcia;
Gariazzo, S.;
Gatti, F.;
Gentile, C.;
Giachero, A.;
Gudmundsson, J. E.;
Hochberg, Y.;
Kahn, Y.;
Kievsky, A.;
Lisanti, M.;
Mancini-Terracciano, C.;
Mangano, G.;
Marcucci, L. E.;
Mariani, C.;
Martínez, J.;
Messina, M.;
Molinero-Vela, A.;
Monticone, E.;
Moroño, A.;
Nucciotti, A.;
Pandolfi, F.;
Parlati, S.;
Pastor, S.;
Pedrós, J.;
Heros, C. Pérez de los;
Pisanti, O.;
Polosa, A. D.;
Puiu, A.;
Rago, I.;
Raitses, Y.;
Rajteri, M.;
Rossi, N.;
Rucandio, I.;
Santorelli, R.;
Schaeffner, K.;
Tully, C. G.;
Viviani, M.;
Zhao, F.;
Zurek, K. M.
Submitted: 2019-02-14, last modified: 2019-09-30
The PTOLEMY project aims to develop a scalable design for a Cosmic Neutrino
Background (CNB) detector, the first of its kind and the only one conceived
that can look directly at the image of the Universe encoded in neutrino
background produced in the first second after the Big Bang. The scope of the
work for the next three years is to complete the conceptual design of this
detector and to validate with direct measurements that the non-neutrino
backgrounds are below the expected cosmological signal. In this paper we
discuss in details the theoretical aspects of the experiment and its physics
goals. In particular, we mainly address three issues. First we discuss the
sensitivity of PTOLEMY to the standard neutrino mass scale. We then study the
perspectives of the experiment to detect the CNB via neutrino capture on
tritium as a function of the neutrino mass scale and the energy resolution of
the apparatus. Finally, we consider an extra sterile neutrino with mass in the
eV range, coupled to the active states via oscillations, which has been
advocated in view of neutrino oscillation anomalies. This extra state would
contribute to the tritium decay spectrum, and its properties, mass and mixing
angle, could be studied by analyzing the features in the beta decay electron
spectrum.
[4]
oai:arXiv.org:1810.06703 [pdf] - 1875231
A Design for an Electromagnetic Filter for Precision Energy Measurements
at the Tritium Endpoint
Betti, M. G.;
Biasotti, M.;
Bosca, A.;
Calle, F.;
Carabe-Lopez, J.;
Cavoto, G.;
Chang, C.;
Chung, W.;
Cocco, A. G.;
Colijn, A. P.;
Conrad, J.;
D'Ambrosio, N.;
de Salas, P. F.;
Faverzani, M.;
Ferella, A.;
Ferri, E.;
Garcia-Abia, P.;
Gomez-Tejedor, G. Garcia;
Gariazzo, S.;
Gatti, F.;
Gentile, C.;
Giachero, A.;
Gudmundsson, J.;
Hochberg, Y.;
Kahn, Y.;
Lisanti, M.;
Mancini-Terracciano, C.;
Mangano, G.;
Marcucci, L. E.;
Mariani, C.;
Martinez, J.;
Messina, M.;
Molinero-Vela, A.;
Monticone, E.;
Nucciotti, A.;
Pandolfi, F.;
Pastor, S.;
Pedros, J.;
Heros, C. Perez de los;
Pisanti, O.;
Polosa, A.;
Puiu, A.;
Raitses, Y.;
Rajteri, M.;
Rossi, N.;
Santorelli, R.;
Schaeffner, K.;
Strid, C. F.;
Tully, C. G.;
Zhao, F.;
Zurek, K. M.
Submitted: 2018-10-15
We present a detailed description of the electromagnetic filter for the
PTOLEMY project to directly detect the Cosmic Neutrino Background (CNB).
Starting with an initial estimate for the orbital magnetic moment, the
higher-order drift process of ExB is configured to balance the gradient-B drift
motion of the electron in such a way as to guide the trajectory into the
standing voltage potential along the mid-plane of the filter. As a function of
drift distance along the length of the filter, the filter zooms in with
exponentially increasing precision on the transverse velocity component of the
electron kinetic energy. This yields a linear dimension for the total filter
length that is exceptionally compact compared to previous techniques for
electromagnetic filtering. The parallel velocity component of the electron
kinetic energy oscillates in an electrostatic harmonic trap as the electron
drifts along the length of the filter. An analysis of the phase-space volume
conservation validates the expected behavior of the filter from the adiabatic
invariance of the orbital magnetic moment and energy conservation following
Liouville's theorem for Hamiltonian systems.
[5]
oai:arXiv.org:1808.01892 [pdf] - 1728123
PTOLEMY: A Proposal for Thermal Relic Detection of Massive Neutrinos and
Directional Detection of MeV Dark Matter
Baracchini, E.;
Betti, M. G.;
Biasotti, M.;
Bosca, A.;
Calle, F.;
Carabe-Lopez, J.;
Cavoto, G.;
Chang, C.;
Cocco, A. G.;
Colijn, A. P.;
Conrad, J.;
D'Ambrosio, N.;
de Salas, P. F.;
Faverzani, M.;
Ferella, A.;
Ferri, E.;
Garcia-Abia, P.;
Gomez-Tejedor, G. Garcia;
Gariazzo, S.;
Gatti, F.;
Gentile, C.;
Giachero, A.;
Gudmundsson, J.;
Hochberg, Y.;
Kahn, Y.;
Lisanti, M.;
Mancini-Terracciano, C.;
Mangano, G.;
Marcucci, L. E.;
Mariani, C.;
Martinez, J.;
Mazzitelli, G.;
Messina, M.;
Molinero-Vela, A.;
Monticone, E.;
Nucciotti, A.;
Pandolfi, F.;
Pastor, S.;
Pedros, J.;
Heros, C. Perez de los;
Pisanti, O.;
Polosa, A.;
Puiu, A.;
Rajteri, M.;
Santorelli, R.;
Schaeffner, K.;
Tully, C. G.;
Raitses, Y.;
Rossi, N.;
Zhao, F.;
Zurek, K. M.
Submitted: 2018-08-06
We propose to achieve the proof-of-principle of the PTOLEMY project to
directly detect the Cosmic Neutrino Background (CNB). Each of the technological
challenges described in [1,2] will be targeted and hopefully solved by the use
of the latest experimental developments and profiting from the low background
environment provided by the LNGS underground site. The first phase will focus
on the graphene technology for a tritium target and the demonstration of TES
microcalorimetry with an energy resolution of better than 0.05 eV for low
energy electrons. These technologies will be evaluated using the PTOLEMY
prototype, proposed for underground installation, using precision HV controls
to step down the kinematic energy of endpoint electrons to match the
calorimeter dynamic range and rate capabilities. The second phase will produce
a novel implementation of the EM filter that is scalable to the full target
size and which demonstrates intrinsic triggering capability for selecting
endpoint electrons. Concurrent with the CNB program, we plan to exploit and
develop the unique properties of graphene to implement an intermediate program
for direct directional detection of MeV dark matter [3,4]. This program will
evaluate the radio-purity and scalability of the graphene fabrication process
with the goal of using recently identified ultra-high radio-purity CO2 sources.
The direct detection of the CNB is a snapshot of early universe dynamics
recorded by the thermal relic neutrino yield taken at a time that predates the
epochs of Big Bang Nucleosynthesis, the Cosmic Microwave Background and the
recession of galaxies (Hubble Expansion). Big Bang neutrinos are believed to
have a central role in the evolution of the Universe and a direct measurement
with PTOLEMY will unequivocally establish the extent to which these predictions
match present-day neutrino densities.
[6]
oai:arXiv.org:1807.08561 [pdf] - 1720395
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: assessing the
role of the athermal phonons collectors in the AC-S8 prototype
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Corsini, Dario;
Gatti, Flavio;
Torrioli, Guido
Submitted: 2018-07-23
The ATHENA X-ray Observatory is the second large-class mission in the ESA
Cosmic Vision 2015-2025 science programme. One of the two on-board instruments
is the X-IFU, an imaging spectrometer based on a large array of TES
microcalorimeters. To reduce the particle-induced background, the spectrometer
works in combination with a Cryogenic Anticoincidence detector (CryoAC), placed
less than 1 mm below the TES array. The last CryoAC single-pixel prototypes,
namely AC-S7 and AC-S8, are based on large area (1 cm2) Silicon absorbers
sensed by 65 parallel-connected iridium TES. This design has been adopted to
improve the response generated by the athermal phonons, which will be used as
fast anticoincidence flag. The latter sample is featured also with a network of
Aluminum fingers directly connected to the TES, designed to further improve the
athermals collection efficiency. In this paper we will report the main results
obtained with AC-S8, showing that the additional fingers network is able to
increase the energy collected from the athermal part of the pulses (from the 6%
of AC-S7 up to the 26 % with AC-S8). Furthermore, the finger design is able to
prevent the quasiparticle recombination in the aluminum, assuring a fast pulse
rising front (L/R limited). In our road map, the AC-S8 prototype is the last
step before the development of the CryoAC Demonstration Model (DM), which will
be the detector able to demonstrate the critical technologies expected in the
CryoAC development programme.
[7]
oai:arXiv.org:1807.08565 [pdf] - 1720396
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: improvement of
the test setup towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Corsini, Dario;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-23
The ATHENA X-IFU development program foresees to build and characterize an
instrument Demonstration Model (DM), in order to probe the system critical
technologies before the mission adoption. In this respect, we are now
developing the DM of the X-IFU Cryogenic Anticoincidence Detector (CryoAC),
which will be delivered to the Focal Plane Assembly (FPA) development team for
the integration with the TES array. Before the delivery, we will characterize
and test the CryoAC DM in our CryoLab at INAF/IAPS. In this paper we report the
main results of the activities performed to improve our cryogenic test setup,
making it suitable for the DM integration. These activities mainly consist in
the development of a mechanichal setup and a cryogenic magnetic shielding
system, whose effectiveness has been assessed by FEM simulations and a
measurement at warm. The preliminary performance test has been performed by
means of the last CryoAC single pixel prototype, the AC-S8 pre-DM sample.
[8]
oai:arXiv.org:1807.06092 [pdf] - 1717296
The Athena X-ray Integral Field Unit
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Cappi, Massimo;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rozanska, Agata;
Wilms, Joern;
Bandler, Simon;
Barbera, Marco;
Barcons, Xavier;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Costantini, Elisa;
Decourchelle, Anne;
Hartog, Roland den;
Duband, Lionel;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Sato, Kosuke;
Schaye, Joop;
Shinozaki, Keisuke;
Thibert, Tanguy;
Valenziano, Luca;
Valette, Veronique;
Vink, Jacco;
Webb, Natalie;
Wise, Michael;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Mesnager, Jean-Michel;
Pontet, Bernard;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Bulbul, Esra;
Dadina, Mauro;
Ettori, Stefano;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Kaastra, Jelle;
Mazzotta, Pasquale;
Miller, Jon;
Miniutti, Giovanni;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Simionescu, Aurora;
Torrejon, Jose Miguel;
Frezouls, Benoît;
Geoffray, Hervé;
Peille, Philippe;
Aicardi, Corinne;
André, Jérôme;
Clénet, Antoine;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hervet, Gilles;
Jolly, Antoine;
Ledot, Aurélien;
Maussang, Irwin;
Paillet, Alexis;
Schmisser, Roseline;
Vella, Bruno;
Damery, Jean-Charles;
Boyce, Kevin;
DiPirro, Michael;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Clerc, Nicolas;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Kirsch, Christian;
Cucchetti, Edoardo;
Eckart, Megan;
Ferrando, Philippe;
Natalucci, Lorenzo
Submitted: 2018-07-16
The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray
spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5'
equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a
spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is
based on a large format array of super-conducting molybdenum-gold Transition
Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold
and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector
located underneath the prime TES array enables the non X-ray background to be
reduced. A bath temperature of about 50 mK is obtained by a series of
mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers
which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with
an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing
enables to read out 40 pixels in one single channel. A photon interacting with
an absorber leads to a current pulse, amplified by the readout electronics and
whose shape is reconstructed on board to recover its energy with high accuracy.
The defocusing capability offered by the Athena movable mirror assembly enables
the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like
intensities) by spreading the telescope point spread function over hundreds of
pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and
typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10
or more better than Silicon based X-ray detectors. In this paper, the current
X-IFU baseline is presented, together with an assessment of its anticipated
performance in terms of spectral resolution, background, and count rate
capability. The X-IFU baseline configuration will be subject to a preliminary
requirement review that is scheduled at the end of 2018.
[9]
oai:arXiv.org:1807.02344 [pdf] - 1714361
The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary
test of AC-S9 towards the Demonstration Model
D'Andrea, Matteo;
Macculi, Claudio;
Argan, Andrea;
Lotti, Simone;
Minervini, Gabriele;
Piro, Luigi;
Biasotti, Michele;
Ceriale, Valentina;
Gallucci, Giovanni;
Gatti, Flavio;
Torrioli, Guido;
Volpe, Angela
Submitted: 2018-07-06, last modified: 2018-07-11
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the
ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector,
which will be placed less than 1 mm below the main TES array detector. We are
now producing the CryoAC Demonstration Model (DM): a single pixel prototype
able to probe the detector critical technologies, i.e. the operation at 50 mK
thermal bath, the threshold energy at 20 keV and the reproducibility of the
thermal conductance between the suspended absorber and the thermal bath. This
detector will be integrated and tested in our cryogenic setup at INAF/IAPS, and
then delivered to SRON for the integration in the X-IFU Focal Plane Assemby
(FPA) DM.
In this paper we report the status of the CryoAC DM development, showing the
main result obtained with the last developed prototype, namely AC-S9. This is a
DM-like sample, which we have preliminary integrated and tested before
performing the final etching process to suspend the silicon absorber. The
results are promising for the DM, since despite the limitations due to the
absence of the final etching (high thermal capacity, high thermal conductance,
partial TES surface coverage), we have been able to operate the detector with
TB = 50 mK and to detect 6 keV photons, thus having a low energy threshold
fully compatible with our requirement (20 keV).
[10]
oai:arXiv.org:1705.07004 [pdf] - 1583644
The Cryogenic AntiCoincidence detector for ATHENA X-IFU: a scientific
assessment of the observational capabilities in the hard X-ray band
Submitted: 2017-05-19
ATHENA is a large X-ray observatory, planned to be launched by ESA in 2028
towards an L2 orbit. One of the two instruments of the payload is the X-IFU: a
cryogenic spectrometer based on a large array of TES microcalorimeters, able to
perform integral field spectrography in the 0.2-12 keV band (2.5 eV FWHM at 6
keV). The X-IFU sensitivity is highly degraded by the particle background
expected in the L2 orbit, which is induced by primary protons of both galactic
and solar origin, and mostly by secondary electrons. To reduce the particle
background level and enable the mission science goals, the instrument
incorporates a Cryogenic AntiCoincidence detector (CryoAC). It is a 4 pixel TES
based detector, placed <1 mm below the main array. In this paper we report a
scientific assessment of the CryoAC observational capabilities in the hard
X-ray band (E>10 keV). The aim of the study has been to understand if the
present detector design can be improved in order to enlarge the X-IFU
scientific capability on an energy band wider than the TES array. This is
beyond the CryoAC baseline, being this instrument aimed to operate as
anticoincidence particle detector and not conceived to perform X-ray
observations.
[11]
oai:arXiv.org:1608.08105 [pdf] - 1467926
The Athena X-ray Integral Field Unit (X-IFU)
Barret, Didier;
Trong, Thien Lam;
Herder, Jan-Willem den;
Piro, Luigi;
Barcons, Xavier;
Huovelin, Juhani;
Kelley, Richard;
Mas-Hesse, J. Miguel;
Mitsuda, Kazuhisa;
Paltani, Stéphane;
Rauw, Gregor;
Rożanska, Agata;
Wilms, Joern;
Barbera, Marco;
Bozzo, Enrico;
Ceballos, Maria Teresa;
Charles, Ivan;
Decourchelle, Anne;
Hartog, Roland den;
Duval, Jean-Marc;
Fiore, Fabrizio;
Gatti, Flavio;
Goldwurm, Andrea;
Jackson, Brian;
Jonker, Peter;
Kilbourne, Caroline;
Macculi, Claudio;
Mendez, Mariano;
Molendi, Silvano;
Orleanski, Piotr;
Pajot, François;
Pointecouteau, Etienne;
Porter, Frederick;
Pratt, Gabriel W.;
Prêle, Damien;
Ravera, Laurent;
Renotte, Etienne;
Schaye, Joop;
Shinozaki, Keisuke;
Valenziano, Luca;
Vink, Jacco;
Webb, Natalie;
Yamasaki, Noriko;
Delcelier-Douchin, Françoise;
Du, Michel Le;
Mesnager, Jean-Michel;
Pradines, Alice;
Branduardi-Raymont, Graziella;
Dadina, Mauro;
Finoguenov, Alexis;
Fukazawa, Yasushi;
Janiuk, Agnieszka;
Miller, Jon;
Nazé, Yaël;
Nicastro, Fabrizio;
Sciortino, Salvatore;
Torrejon, Jose Miguel;
Geoffray, Hervé;
Hernandez, Isabelle;
Luno, Laure;
Peille, Philippe;
André, Jérôme;
Daniel, Christophe;
Etcheverry, Christophe;
Gloaguen, Emilie;
Hassin, Jérémie;
Hervet, Gilles;
Maussang, Irwin;
Moueza, Jérôme;
Paillet, Alexis;
Vella, Bruno;
Garrido, Gonzalo Campos;
Damery, Jean-Charles;
Panem, Chantal;
Panh, Johan;
Bandler, Simon;
Biffi, Jean-Marc;
Boyce, Kevin;
Clénet, Antoine;
DiPirro, Michael;
Jamotton, Pierre;
Lotti, Simone;
Schwander, Denis;
Smith, Stephen;
van Leeuwen, Bert-Joost;
van Weers, Henk;
Brand, Thorsten;
Cobo, Beatriz;
Dauser, Thomas;
de Plaa, Jelle;
Cucchetti, Edoardo
Submitted: 2016-08-29
The X-ray Integral Field Unit (X-IFU) on board the Advanced Telescope for
High-ENergy Astrophysics (Athena) will provide spatially resolved
high-resolution X-ray spectroscopy from 0.2 to 12 keV, with 5 arc second pixels
over a field of view of 5 arc minute equivalent diameter and a spectral
resolution of 2.5 eV up to 7 keV. In this paper, we first review the core
scientific objectives of Athena, driving the main performance parameters of the
X-IFU, namely the spectral resolution, the field of view, the effective area,
the count rate capabilities, the instrumental background. We also illustrate
the breakthrough potential of the X-IFU for some observatory science goals.
Then we briefly describe the X-IFU design as defined at the time of the mission
consolidation review concluded in May 2016, and report on its predicted
performance. Finally, we discuss some options to improve the instrument
performance while not increasing its complexity and resource demands (e.g.
count rate capability, spectral resolution).
The X-IFU will be provided by an international consortium led by France, The
Netherlands and Italy, with further ESA member state contributions from
Belgium, Finland, Germany, Poland, Spain, Switzerland and two international
partners from the United States and Japan.
[12]
oai:arXiv.org:1602.07744 [pdf] - 1364436
Multi-mode TES bolometer optimization for the LSPE-SWIPE instrument
Submitted: 2016-02-24
In this paper we explore the possibility of using transition edge sensor
(TES) detectors in multi-mode configuration in the focal plane of the Short
Wavelength Instrument for the Polarization Explorer (SWIPE) of the
balloon-borne polarimeter Large Scale Polarization Explorer (LSPE) for the
Cosmic Microwave Background (CMB) polarization. This study is motivated by the
fact that maximizing the sensitivity of TES bolometers, under the augmented
background due to the multi-mode design, requires a non trivial choice of
detector parameters. We evaluate the best parameter combination taking into
account scanning strategy, noise constraints, saturation power and operating
temperature of the cryostat during the flight.
[13]
oai:arXiv.org:1308.6784 [pdf] - 713384
The Hot and Energetic Universe: The X-ray Integral Field Unit (X-IFU)
for Athena+
Barret, D.;
Herder, J. W. den;
Piro, L.;
Ravera, L.;
Hartog, R. Den;
Macculi, C.;
Barcons, X.;
Page, M.;
Paltani, S.;
Rauw, G.;
Wilms, J.;
Ceballos, M.;
Duband, L.;
Gottardi, L.;
Lotti, S.;
de Plaa, J.;
Pointecouteau, E.;
Schmid, C.;
Akamatsu, H.;
Bagliani, D.;
Bandler, S.;
Barbera, M.;
Bastia, P.;
Biasotti, M.;
Branco, M.;
Camon, A.;
Cara, C.;
Cobo, B.;
Colasanti, L.;
Costa-Kramer, J. L.;
Corcione, L.;
Doriese, W.;
Duval, J. M.;
Fabrega, L.;
Gatti, F.;
de Gerone, M.;
Guttridge, P.;
Kelley, R.;
Kilbourne, C.;
van der Kuur, J.;
Mineo, T.;
Mitsuda, K.;
Natalucci, L.;
Ohashi, T.;
Peille, P.;
Perinati, E.;
Pigot, C.;
Pizzigoni, G.;
Pobes, C.;
Porter, F.;
Renotte, E.;
Sauvageot, J. L.;
Sciortino, S.;
Torrioli, G.;
Valenziano, L.;
Willingale, D.;
de Vries, C.;
van Weers, H.
Submitted: 2013-08-30
The Athena+ mission concept is designed to implement the Hot and Energetic
Universe science theme submitted to the European Space Agency in response to
the call for White Papers for the definition of the L2 and L3 missions of its
science program. The Athena+ science payload consists of a large aperture high
angular resolution X-ray optics and twelve meters away, two interchangeable
focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide
Field Imager (WFI). The X-IFU is a cryogenic X-ray spectrometer, based on a
large array of Transition Edge Sensors (TES), offering 2.5 eV spectral
resolution, with ~5" pixels, over a field of view of 5 arc minutes in diameter.
In this paper, we briefly describe the Athena+ mission concept and the X-IFU
performance requirements. We then present the X-IFU detector and readout
electronics principles, the current design of the focal plane assembly, the
cooling chain and review the global architecture design. Finally, we describe
the current performance estimates, in terms of effective area, particle
background rejection, count rate capability and velocity measurements. Finally,
we emphasize on the latest technology developments concerning TES array
fabrication, spectral resolution and readout performance achieved to show that
significant progresses are being accomplished towards the demanding X-IFU
requirements.
[14]
oai:arXiv.org:1202.4763 [pdf] - 545013
The Electron Capture Decay of 163-Ho to Measure the Electron Neutrino
Mass with sub-eV Accuracy (and Beyond)
Submitted: 2012-02-21, last modified: 2012-08-02
We have investigated the possibility of measuring the electron neutrino mass
with sub-eV sensitivity by studying the electron capture decay of 163-Ho with
cryogenic microcalorimeters. In this paper we will introduce an experiment's
concept, discuss the technical requirements, and identify a roadmap to reach a
sensitivity of 0.1 eV and beyond.
[15]
oai:arXiv.org:1104.2048 [pdf] - 576598
ORIGIN: Metal Creation and Evolution from the Cosmic Dawn
Herder, J. W. den;
Piro, L.;
Ohashi, T.;
Kouveliotou, C.;
Hartmann, D. H.;
Kaastra, J. S.;
Amati, L.;
Andersen, M. I.;
Arnaud, M.;
Attéia, J-L.;
Bandler, S.;
Barbera, M.;
Barcons, X.;
Barthelmy, S.;
Basa, S.;
Basso, S.;
Boer, M.;
Branchini, E.;
Branduardi-Raymont, G.;
Borgani, S.;
Boyarsky, A.;
Brunetti, G.;
Budtz-Jorgensen, C.;
Burrows, D.;
Butler, N.;
Campana, S.;
Caroli, E.;
Ceballos, M.;
Christensen, F.;
Churazov, E.;
Comastri, A.;
Colasanti, L.;
Cole, R.;
Content, R.;
Corsi, A.;
Costantini, E.;
Conconi, P.;
Cusumano, G.;
de Plaa, J.;
De Rosa, A.;
Del Santo, M.;
Di Cosimo, S.;
De Pasquale, M.;
Doriese, R.;
Ettori, S.;
Evans, P.;
Ezoe, Y.;
Ferrari, L.;
Finger, H.;
Figueroa-Feliciano, T.;
Friedrich, P.;
Fujimoto, R.;
Furuzawa, A.;
Fynbo, J.;
Gatti, F.;
Galeazzi, M.;
Gehrels, N.;
Gendre, B.;
Ghirlanda, G.;
Ghisellini, G.;
Gilfanov, M.;
Giommi, P.;
Girardi, M.;
Grindlay, J.;
Cocchi, M.;
Godet, O.;
Guedel, M.;
Haardt, F.;
Hartog, R. den;
Hepburn, I.;
Hermsen, W.;
Hjorth, J.;
Hoekstra, H.;
Holland, A.;
Hornstrup, A.;
van der Horst, A.;
Hoshino, A.;
Zand, J. in 't;
Irwin, K.;
Ishisaki, Y.;
Jonker, P.;
Kitayama, T.;
Kawahara, H.;
Kawai, N.;
Kelley, R.;
Kilbourne, C.;
de Korte, P.;
Kusenko, A.;
Kuvvetli, I.;
Labanti, M.;
Macculi, C.;
Maiolino, R.;
Hesse, M. Mas;
Matsushita, K.;
Mazzotta, P.;
McCammon, D.;
Méndez, M.;
Mignani, R.;
Mineo, T.;
Mitsuda, K.;
Mushotzky, R.;
Molendi, S.;
Moscardini, L.;
Natalucci, L.;
Nicastro, F.;
O'Brien, P.;
Osborne, J.;
Paerels, F.;
Page, M.;
Paltani, S.;
Pedersen, K.;
Perinati, E.;
Ponman, T.;
Pointecouteau, E.;
Predehl, P.;
Porter, S.;
Rasmussen, A.;
Rauw, G.;
Röttgering, H.;
Roncarelli, M.;
Rosati, P.;
Quadrini, E.;
Ruchayskiy, O.;
Salvaterra, R.;
Sasaki, S.;
Sato, K.;
Savaglio, S.;
Schaye, J.;
Sciortino, S.;
Shaposhnikov, M.;
Sharples, R.;
Shinozaki, K.;
Spiga, D.;
Sunyaev, R.;
Suto, Y.;
Takei, Y.;
Tanvir, N.;
Tashiro, M.;
Tamura, T.;
Tawara, Y.;
Troja, E.;
Tsujimoto, M.;
Tsuru, T.;
Ubertini, P.;
Ullom, J.;
Ursino, E.;
Verbunt, F.;
van de Voort, F.;
Viel, M.;
Wachter, S.;
Watson, D.;
Weisskopf, M.;
Werner, N.;
White, N.;
Willingale, R.;
Wijers, R.;
Yamasaki, N.;
Yoshikawa, K.;
Zane, S.
Submitted: 2011-04-11, last modified: 2011-04-15
ORIGIN is a proposal for the M3 mission call of ESA aimed at the study of
metal creation from the epoch of cosmic dawn. Using high-spectral resolution in
the soft X-ray band, ORIGIN will be able to identify the physical conditions of
all abundant elements between C and Ni to red-shifts of z=10, and beyond. The
mission will answer questions such as: When were the first metals created? How
does the cosmic metal content evolve? Where do most of the metals reside in the
Universe? What is the role of metals in structure formation and evolution? To
reach out to the early Universe ORIGIN will use Gamma-Ray Bursts (GRBs) to
study their local environments in their host galaxies. This requires the
capability to slew the satellite in less than a minute to the GRB location. By
studying the chemical composition and properties of clusters of galaxies we can
extend the range of exploration to lower redshifts (z ~ 0.2). For this task we
need a high-resolution spectral imaging instrument with a large field of view.
Using the same instrument, we can also study the so far only partially detected
baryons in the Warm-Hot Intergalactic Medium (WHIM). The less dense part of the
WHIM will be studied using absorption lines at low redshift in the spectra for
GRBs.
[16]
oai:arXiv.org:1002.0867 [pdf] - 1513441
SAGACE: the Spectroscopic Active Galaxies And Clusters Explorer
De Bernardis, P.;
Bagliani, D.;
Bardi, A.;
Battistelli, E.;
Birkinshaw, M.;
Calvo, M.;
Colafrancesco, S.;
Conte, A.;
De Gregori, S.;
De Petris, M.;
De Zotti, G.;
Donati, A.;
Ferrari, L.;
Franceschini, A.;
Gatti, F.;
Gervasi, M.;
Giommi, P.;
Giordano, C.;
Gonzalez-Nuevo, J.;
Lamagna, L.;
Lapi, A.;
Luzzi, G.;
Maiolino, R.;
Marchegiani, P.;
Mariani, A.;
Masi, S.;
Massardi, M.;
Mauskopf, P.;
Nati, F.;
Nati, L.;
Natoli, P.;
Negrello, M.;
Piacentini, F.;
Polenta, G.;
Salatino, M.;
Savini, G.;
Schillaci, A.;
Spinelli, S.;
Tartari, A.;
Tavanti, M.;
Tortora, A.;
Vaccari, M.;
Vaccarone, R.;
Zannoni, M.;
Zolesi, V.
Submitted: 2010-02-03
The SAGACE experiment consists of a mm/sub-mm telescope with a 3-m diameter
primary mirror, coupled to a cryogenic multi-beam differential spectrometer.
SAGACE explores the sky in the 100-760 GHz frequency range, using four
diffraction-limited bolometer arrays. The instrument is designed to perform
spectroscopic surveys of the Sunyaev-Zeldovich effects of thousands of galaxy
clusters, of the spectral energy distribution of active galactic nuclei, and of
the [CII] line of a thousand galaxies in the redshift desert. In 2008 a full
phase-A study for a national small mission was completed and delivered to the
Italian Space Agency (ASI). We have shown that taking advantage of the
differential operation of the Fourier Transform Spectrometer, this ambitious
instrument can operate from a Molniya orbit, and can be built and operated
within the tight budget of a small mission.