Normalized to: Gastler, D.
[1]
oai:arXiv.org:1408.1914 [pdf] - 1216195
Improving Photoelectron Counting and Particle Identification in
Scintillation Detectors with Bayesian Techniques
Akashi-Ronquest, M.;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bodmer, M.;
Boulay, M. G.;
Broerman, B.;
Buck, B.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chen, Y.;
Cleveland, B.;
Coakley, K.;
Dering, K.;
Duncan, F. A.;
Formaggio, J. A.;
Gagnon, R.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grace, E.;
Guerrero, N.;
Guiseppe, V.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Henning, R.;
Hime, A.;
Hofgartner, J.;
Jaditz, S.;
Jillings, C. J.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Kuzniak, M.;
LaTorre, A.;
Lawson, I.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Linden, S.;
McFarlane, K.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mathew, R.;
McDonald, A. B.;
Mei, D. -M.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J. A.;
Noble, T.;
O'Dwyer, E.;
Olsen, K.;
Gann, G. D. Orebi;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Perumpilly, G.;
Pollmann, T.;
Rau, P.;
Retiere, F.;
Rielage, K.;
Schnee, R.;
Seibert, S.;
Skensved, P.;
Sonley, T.;
Vazquez-Jauregui, E.;
Veloce, L.;
Walding, J.;
Wang, B.;
Wang, J.;
Ward, M.;
Zhang, C.
Submitted: 2014-08-08, last modified: 2014-12-12
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.
[2]
oai:arXiv.org:1403.4842 [pdf] - 799232
Update on the MiniCLEAN Dark Matter Experiment
Rielage, K.;
Akashi-Ronquest, M.;
Bodmer, M.;
Bourque, R.;
Buck, B.;
Butcher, A.;
Caldwell, T.;
Chen, Y.;
Coakley, K.;
Flores, E.;
Formaggio, J. A.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Grace, E.;
Griego, J.;
Guerrero, N.;
Guiseppe, V.;
Henning, R.;
Hime, A.;
Jaditz, S.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Latorre, A.;
Lawson, I.;
Linden, S.;
Lopez, F.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mei, D. -M.;
Monroe, J.;
Nikkel, J. A.;
Oertel, J.;
Gann, G. D. Orebi;
Palladino, K.;
Perumpilly, G.;
Rodriguez, L.;
Schnee, R.;
Seibert, S.;
Walding, J.;
Wang, B.;
Wang, J.;
Zhang, C.
Submitted: 2014-03-19
The direct search for dark matter is entering a period of increased
sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One
such technology that is being examined is a scintillation only noble liquid
experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to
detect nuclear recoils from WIMP dark matter and serves as a demonstration for
a future detector of order 50 to 100 tonnes. The liquid cryogen is
interchangeable between argon and neon to study the A$^{2}$ dependence of the
potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular
design with spherical geometry to maximize the light yield using cold
photomultiplier tubes in a single-phase detector. Pulse shape discrimination
techniques are used to separate nuclear recoil signals from electron recoil
backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate
the effective reach of the pulse shape discrimination capability. Assembly of
the experiment is underway at SNOLAB and an update on the project is given.
[3]
oai:arXiv.org:1111.3260 [pdf] - 548322
Scintillation yield and time dependence from electronic and nuclear
recoils in liquid neon
Submitted: 2011-11-14, last modified: 2012-08-13
We have performed measurements of scintillation light in liquid neon,
observing a signal yield in our detector as high as (3.5 $\pm$ 0.4)
photoelectrons/keV. We measure pulse shape discrimination efficiency between
electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear
recoil energy. We also measure the \leff\, parameter in liquid neon between 30
and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50
keV. We observe a dependence of the scintillation time distribution and signal
yield on the pressure and temperature of the liquid neon.
[4]
oai:arXiv.org:1004.0373 [pdf] - 672810
Measurement of scintillation efficiency for nuclear recoils in liquid
argon
Submitted: 2010-04-02, last modified: 2012-05-08
The scintillation light yield of liquid argon from nuclear recoils relative
to electronic recoils has been measured as a function of recoil energy from 10
keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the
nuclear recoil scintillation response to the electronic recoil response, is
0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
[5]
oai:arXiv.org:0911.5453 [pdf] - 146838
Calibration of liquid argon and neon detectors with $^{83}Kr^m$
Submitted: 2009-11-30
We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration
source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are
produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$
scintillation peak at 41.5 keV appears in both liquids when filling our
detector through a piece of zeolite coated with $^{83}$Rb. Based on this
scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a
resolution of 6% ($\sigma$/E) and 3.0 photoelectrons/keV in liquid neon with a
resolution of 19% ($\sigma$/E). The observed peak intensity subsequently decays
with the $^{83}$Kr$^{\mathrm{m}}$ half-life after stopping the fill, and we
find evidence that the spatial location of $^{83}$Kr$^{\mathrm{m}}$ atoms in
the chamber can be resolved. $^{83}$Kr$^{\mathrm{m}}$ will be a useful
calibration source for liquid argon and neon dark matter and solar neutrino
detectors.