Normalized to: Gascon, J.
[1]
oai:arXiv.org:2003.01046 [pdf] - 2057126
First germanium-based constraints on sub-MeV Dark Matter with the
EDELWEISS experiment
EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Elkhoury, E.;
Fillipini, J. -B.;
Filosofov, D.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Lattaud, H.;
Marnieros, S.;
Misiak, D.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Oriol, C.;
Pari, P.;
Paul, B.;
Poda, D.;
Rozov, S.;
Salagnac, T.;
Sanglard, V.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zolotarova, A.
Submitted: 2020-03-02
The EDELWEISS collaboration has performed a search for Dark Matter (DM)
particles interacting with electrons using a 33.4 g Ge cryogenic detector
operated underground at the LSM. A charge resolution of 0.53 electron-hole
pairs (RMS) has been achieved using the Neganov-Trofimov-Luke amplification
with a bias of 78 V. We set the first Ge-based constraints on sub-MeV/c$^{2}$
DM particles interacting with electrons, as well as on dark photons down to 1
eV/c$^2$. These are competitive with other searches. In particular, new limits
are set on the kinetic mixing of dark photon DM in a so far unconstrained
parameter space region in the 6 to 9 eV/c$^2$ mass range. These results
demonstrate the high relevance of cryogenic Ge detectors for the search of DM
interactions producing eV-scale electron signals.
[2]
oai:arXiv.org:1901.03588 [pdf] - 1871473
Searching for low-mass dark matter particles with a massive Ge bolometer
operated above-ground
Armengaud, E.;
Augier, C.;
Benoît, A.;
Benoit, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapelier, M.;
Charlieux, F.;
Ducimetière, D.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
De Jésus, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Maisonobe, R.;
Marnieros, S.;
Misiak, D.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Oriol, C.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zolotarova, A.;
Kavanagh, B. J.
Submitted: 2019-01-11, last modified: 2019-04-02
The EDELWEISS collaboration has performed a search for dark matter particles
with masses below the GeV-scale with a 33.4-g germanium cryogenic detector
operated in a surface lab. The energy deposits were measured using a
neutron-transmutation-doped Ge thermal sensor with a 17.7~eV (RMS) baseline
heat energy resolution leading to a 60~eV analysis energy threshold. Despite a
moderate lead shielding and the high-background environment, the first sub-GeV
spin-independent dark matter limit based on a germanium target has been
achieved. The experiment provides the most stringent, nuclear recoil based,
above-ground limit on spin-independent interactions above 600~MeV/c$^{2}$. The
experiment also provides the most stringent limits on spin-dependent
interactions with protons and neutrons below 1.3~GeV/c$^{2}$. Furthermore, the
dark matter search results were studied in the context of Strongly Interacting
Massive Particles, taking into account Earth-shielding effects, for which new
regions of the available parameter space have been excluded. Finally, the dark
matter search has also been extended to interactions via the Migdal effect,
resulting for the first time in the exclusion of particles with masses between
45 and 150~MeV/c$^{2}$ with spin-independent cross sections ranging from
$10^{-29}$ to $10^{-26}$~cm$^2$.
[3]
oai:arXiv.org:1707.04308 [pdf] - 1622237
Optimizing EDELWEISS detectors for low-mass WIMP searches
EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Maisonobe, R.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2017-07-11
The physics potential of EDELWEISS detectors for the search of low-mass
Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven
background model, projected exclusion limits are computed using frequentist and
multivariate analysis approaches, namely profile likelihood and boosted
decision tree. Both current and achievable experimental performance are
considered. The optimal strategy for detector optimization depends critically
on whether the emphasis is put on WIMP masses below or above $\sim$ 5
GeV/c$^2$. The projected sensitivity for the next phase of the EDELWEISS-III
experiment at the Modane Underground Laboratory (LSM) for low-mass WIMP search
is presented. By 2018 an upper limit on the spin-independent WIMP-nucleon
cross-section of $\sigma_{SI} = 7 \times 10^{-42}$ cm$^2$ is expected for a
WIMP mass in the range 2$-$5 GeV/c$^2$. The requirements for a future
hundred-kilogram scale experiment designed to reach the bounds imposed by the
coherent scattering of solar neutrinos are also described. By improving the
ionization resolution down to 50 eV$_{ee}$, we show that such an experiment
installed in an even lower background environment (e.g. at SNOLAB) should allow
to observe about 80 $^8$B neutrino events after discrimination.
[4]
oai:arXiv.org:1706.01070 [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter
searches
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Maisonobe, R.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.;
Zolotarova, A.
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the
EDELWEISS-III array of cryogenic germanium detectors for direct dark matter
searches. The experimental setup and the FID (Fully Inter-Digitized) detector
array is described, as well as the efficiency of the double measurement of heat
and ionization signals in background rejection. For the whole set of 24 FID
detectors used for coincidence studies, the baseline resolutions for the
fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the
baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM).
The response to nuclear recoils as well as the very good discrimination
capability of the FID design has been measured with an AmBe source. The surface
$\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times
10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source,
the rejection of bulk $\gamma$-ray events has been demonstrated using
$\gamma$-calibrations with $^{133}$Ba sources leading to a value of
$R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels
of natural radioactivity measured in the detector array are shown as the rate
of single $\gamma$ background. The fiducial volume fraction of the FID
detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$
using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The
stability and uniformity of the detector response is also discussed. The
achieved resolutions, thresholds and background levels of the upgraded
EDELWEISS-III detectors in their setup are thus well suited to the direct
search of WIMP dark matter over a large mass range.
[5]
oai:arXiv.org:1607.03367 [pdf] - 1497465
Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile
likelihood approach
EDELWEISS Collaboration;
Hehn, L.;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Heuermann, G.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-07-12, last modified: 2016-09-20
We report on a dark matter search for a Weakly Interacting Massive Particle
(WIMP) in the mass range $m_\chi \in [4, 30]\,\mathrm{GeV}/c^2$ with the
EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data
from eight selected detectors with the lowest energy thresholds leading to a
combined fiducial exposure of 496 kg-days. External backgrounds from $\gamma$-
and $\beta$-radiation, recoils from $^{206}$Pb and neutrons as well as detector
intrinsic backgrounds were modelled from data outside the region of interest
and constrained in the analysis. The basic data selection and most of the
background models are the same as those used in a previously published analysis
based on Boosted Decision Trees (BDT). For the likelihood approach applied in
the analysis presented here, a larger signal efficiency and a subtraction of
the expected background lead to a higher sensitivity, especially for the lowest
WIMP masses probed. No statistically significant signal was found and upper
limits on the spin-independent WIMP-nucleon scattering cross section can be set
with a hypothesis test based on the profile likelihood test statistics. The 90%
C.L. exclusion limit set for WIMPs with $m_\chi = 4\,\mathrm{GeV/}c^2$ is $1.6
\times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven
with respect to the BDT-based analysis. For WIMP masses above
$15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in
good agreement.
[6]
oai:arXiv.org:1607.04560 [pdf] - 1438577
Measurement of the cosmogenic activation of germanium detectors in
EDELWEISS-III
The EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Heuermann, G.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-07-15
We present a measurement of the cosmogenic activation in the germanium
cryogenic detectors of the EDELWEISS III direct dark matter search experiment.
The decay rates measured in detectors with different exposures to cosmic rays
above ground are converted into production rates of different isotopes. The
measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H,
2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for
$^{65}$Zn. These results are the most accurate for these isotopes. A lower
limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also
presented. They are compared to model predictions present in literature and to
estimates calculated with the ACTIVIA code.
[7]
oai:arXiv.org:1606.08097 [pdf] - 1507589
Signals induced by charge-trapping in EDELWEISS FID detectors:
analytical modeling and applications
The EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Fourches, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Heuermann, G.;
De Jésus, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kéfélian, C.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-06-26, last modified: 2016-06-29
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge
detectors Fully covered with Inter-Digitized electrodes (FID). They are
operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence
charge-carrier trapping significantly affects both the ionization and heat
energy measurements. This paper describes an analytical model of the signals
induced by trapped charges in FID detectors based on the Shockley-Ramo theorem.
It is used to demonstrate that veto electrodes, initially designed for the sole
purpose of surface event rejection, can be used to provide a sensitivity to the
depth of the energy deposits, characterize the trapping in the crystals,
perform heat and ionization energy corrections and improve the ionization
baseline resolutions. These procedures are applied successfully to actual data.
[8]
oai:arXiv.org:1603.05120 [pdf] - 1403150
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
De Jésus, M.;
Jin, Y.;
Jokisch, S.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D. V.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2016-03-16, last modified: 2016-05-09
We present the results of a search for elastic scattering from galactic dark
matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30
GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an
array of 800 g Germanium bolometers equipped with a set of interleaved
electrodes with full surface coverage. We searched specifically for $\sim
2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an
illustration the number of observed events in the search for 5 (resp. 20)
GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1
(resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times
10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering
cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a
41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP
search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints
of WIMP signals from some recent experiments, thus confirming results obtained
with different detection techniques.
[9]
oai:arXiv.org:1307.1488 [pdf] - 844079
Axion searches with the EDELWEISS-II experiment
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoit, A.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
de Boissière, T.;
De Jesus, M.;
Dolgorouky, Y.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Holtzer, N.;
Humbert, V.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Mancuso, M.;
Marrache-Kikuchi, C.;
Marnieros, S.;
Menshikov, A.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. C.;
Rigaut, O.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Tenconi, M.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-07-04
We present new constraints on the couplings of axions and more generic
axion-like particles using data from the EDELWEISS-II experiment. The EDELWEISS
experiment, located at the Underground Laboratory of Modane, primarily aims at
the direct detection of WIMPs using germanium bolometers. It is also sensitive
to the low-energy electron recoils that would be induced by solar or dark
matter axions. Using a total exposure of up to 448 kg.d, we searched for
axion-induced electron recoils down to 2.5 keV within four scenarios involving
different hypotheses on the origin and couplings of axions. We set a 95% CL
limit on the coupling to photons $g_{A\gamma}<2.13\times 10^{-9}$ GeV$^{-1}$ in
a mass range not fully covered by axion helioscopes. We also constrain the
coupling to electrons, $g_{Ae} < 2.56\times 10^{-11}$, similar to the more
indirect solar neutrino bound. Finally we place a limit on $g_{Ae}\times
g_{AN}^{\rm eff}<4.70 \times 10^{-17}$, where $g_{AN}^{\rm eff}$ is the
effective axion-nucleon coupling for $^{57}$Fe. Combining these results we
fully exclude the mass range $0.91\,{\rm eV}<m_A<80$ keV for DFSZ axions and
$5.73\,{\rm eV}<m_A<40$ keV for KSVZ axions.
[10]
oai:arXiv.org:1302.7112 [pdf] - 633724
Muon-induced background in the EDELWEISS dark matter search
The EDELWEISS collaboration;
Schmidt, B.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Collin, S.;
Coulter, P.;
Cox, G. A.;
Crauste, O.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Juillard, A.;
Kluck, H.;
Kozlov, V. Y.;
Kleifges, M.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nieder, H.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrentó-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-02-28
A dedicated analysis of the muon-induced background in the EDELWEISS dark
matter search has been performed on a data set acquired in 2009 and 2010. The
total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was
measured to be $\Phi_{\mu}=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The
modular design of the muon-veto system allows the reconstruction of the muon
trajectory and hence the determination of the angular dependent muon flux in
LSM. The results are in good agreement with both MC simulations and earlier
measurements. Synchronization of the muon-veto system with the phonon and
ionization signals of the Ge detector array allowed identification of
muon-induced events. Rates for all muon-induced events $\Gamma^{\mu}=(0.172 \pm
0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $\Gamma^{\mu-n} =
0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After
vetoing, the remaining rate of accepted muon-induced neutrons in the
EDELWEISS-II dark matter search was determined to be $\Gamma^{\mu-n}_{\rm
irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on
these results, the muon-induced background expectation for an anticipated
exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{\mu-n}_{3000 kg\cdot d} < 0.6$
events.
[11]
oai:arXiv.org:1207.1815 [pdf] - 568705
A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization
detectors
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Couëdo, F.;
Coulter, P.;
Cox, G. A.;
Domange, J.;
Drillien, A. A.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Heuermann, G.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kleifges, M.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Sueur, H. Le;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrento-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2012-07-07, last modified: 2012-09-05
We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear
recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium
detectors equipped with thermal sensors and an electrode design (ID) which
allows to efficiently reject several sources of background. The data indicate
no evidence for an exponential distribution of low-energy nuclear recoils that
could be attributed to WIMP elastic scattering after an exposure of 113 kg.d.
For WIMPs of mass 10 GeV, the observation of one event in the WIMP search
region results in a 90% CL limit of 1.0x10^-5 pb on the spin-independent
WIMP-nucleon scattering cross-section, which constrains the parameter space
associated with the findings reported by the CoGeNT, DAMA and CRESST
experiments.
[12]
oai:arXiv.org:1103.4070 [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of
cryogenic germanium detectors with interleaved electrodes
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chardin, G.;
Chapellier, M.;
Charlieux, F.;
Coulter, P.;
Cox, G. A.;
Defay, X.;
De Jesus, M.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A-S.;
Vagneron, L.;
Verdier, M-A.;
Walker, R. J.;
Yakushev, E.
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark
matter with an array of ten 400-g cryogenic germanium detectors in operation at
the Laboratoire Souterrain de Modane. The combined use of thermal phonon
sensors and charge collection electrodes with an interleaved geometry enables
the efficient rejection of gamma-induced radioactivity as well as near-surface
interactions. A total effective exposure of 384 kg.d has been achieved, mostly
coming from fourteen months of continuous operation. Five nuclear recoil
candidates are observed above 20 keV, while the estimated background is 3.0
events. The result is interpreted in terms of limits on the cross-section of
spin-independent interactions of WIMPs and nucleons. A cross-section of
4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints
are also set on models where the WIMP-nucleon scattering is inelastic.
[13]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[14]
oai:arXiv.org:1006.3098 [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark
Matter searches
Kozlov, V. Yu.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X. -F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number
of low count rate experiments, namely direct searches for Dark Matter. In this
work we describe a neutron detector to measure this background in an
underground laboratory, the Laboratoire Souterrain de Modane. The system is
based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of
the EDELWEISS-II experiment for coincident muon detection. The system was
installed in autumn 2008 and passed since then a number of commissioning tests
proving its full functionality. The data-taking is continuously ongoing and a
count rate of the order of 1 muon-induced neutron per day has been achieved.
[15]
oai:arXiv.org:1001.4383 [pdf] - 33100
Monitoring of the thermal neutron flux in the LSM underground laboratory
Rozov, S.;
Armengaud, E.;
Augier, C.;
Bergé, L.;
Benoit, A.;
Besida, O.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Defay, X.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrach, C.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M-A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2010-01-25
This paper describes precise measurements of the thermal neutron flux in the
LSM underground laboratory in proximity of the EDELWEISS-II dark matter search
experiment together with short measurements at various other locations.
Monitoring of the flux of thermal neutrons is accomplished using a mobile
detection system with low background proportional counter filled with $^3$He.
On average 75 neutrons per day are detected with a background level below 1
count per day (cpd). This provides a unique possibility of a day by day study
of variations of the neutron field in a deep underground site. The measured
average 4$\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is
$\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We
report the first experimental observation that the point-to-point thermal
neutron flux at LSM varies by more than a factor two.
[16]
oai:arXiv.org:0912.0805 [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic
detectors with interleaved electrodes
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X-F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.;
Collaboration, the EDELWEISS
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark
matter with an array of ten 400 g heat-and-ionization cryogenic detectors
equipped with interleaved electrodes for the rejection of near-surface events.
Six months of continuous operation at the Laboratoire Souterrain de Modane have
been achieved. The observation of one nuclear recoil candidate above 20 keV in
an effective exposure of 144 kgd is interpreted in terms of limits on the
cross-section of spin-independent interactions of WIMPs and nucleons. A
cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80
GeV/c2. This result demonstrates for the first time the very high background
rejection capabilities of these simple and robust detectors in an actual WIMP
search experiment.
[17]
oai:arXiv.org:0906.4232 [pdf] - 25561
Direct Dark Matter Searches and the EDELWEISS-II Experiment
Submitted: 2009-06-23
Direct searches for Dark Matter are experiment dedicated to the observation
of the energetic recoiling ions produced by the scattering of WIMP particles
from our galactic halo on terrestrial targets. The status and prospects of some
currently running experiments are presented, together with new preliminary
results of the experiments EDELWEISS-II.
[18]
oai:arXiv.org:0905.0753 [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Broniatowski, A.;
Defay, X.;
Armengaud, E.;
Berge, L.;
Benoit, A.;
Besida, O.;
Blumer, J.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrache, C.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M. -A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is
presented, taking advantage of the coplanar grid technique of event
localisation for improved background discrimination. Experiments performed with
prototype devices in the EDELWEISS II setup at the Modane underground facility
demonstrate the remarkably high efficiency of these devices for the rejection
of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate
the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as
proposed in the EURECA project of a one-ton cryogenic detector mass.
[19]
oai:arXiv.org:astro-ph/0610821 [pdf] - 86245
Identification of backgrounds in the EDELWEISS-I dark matter search
experiment
Fiorucci, S.;
Benoit, A.;
Berge, L.;
Blumer, J.;
Broniatowski, A.;
Censier, B.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Gros, M.;
Horn, M.;
Juillard, A.;
Lemrani, R.;
De Lesquen, A.;
Lubashevskiy, A.;
Luca, M.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Olivieri, O.;
Pari, P.;
Sanglard, V.;
Schoeffel, L.;
Schwamm, F.;
Stern, M.;
Yakushev, E.
Submitted: 2006-10-27, last modified: 2007-05-10
This paper presents our interpretation and understanding of the different
backgrounds in the EDELWEISS-I data sets. We analyze in detail the several
populations observed, which include gammas, alphas, neutrons, thermal sensor
events and surface events, and try to combine all data sets to provide a
coherent picture of the nature and localisation of the background sources. In
light of this interpretation, we draw conclusions regarding the background
suppression scheme for the EDELWEISS-II phase.
[20]
oai:arXiv.org:astro-ph/0607502 [pdf] - 83705
Measurement of the response of heat-and-ionization germanium detectors
to nuclear recoils
Benoit, A.;
Berge, L.;
Blumer, J.;
Broniatowski, A.;
Censier, B.;
Chantelauze, A.;
/Chapellier, M.;
Chardin, G.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Fiorucci, S.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Gros, M.;
Horn, M.;
Juillard, A.;
Lemrani, R.;
de Lesquen, A.;
Luca, M.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Olivieri, E.;
Pari, P.;
Sanglard, V.;
Schoeffel, L.;
Schwamm, F.;
Stern, M.
Submitted: 2006-07-21
The heat quenching factor Q' (the ratio of the heat signals produced by
nuclear and electron recoils of equal energy) of the heat-and-ionization
germanium bolometers used by the EDELWEISS collaboration has been measured. It
is explained how this factor affects the energy scale and the effective
quenching factor observed in calibrations with neutron sources. This effective
quenching effect is found to be equal to Q/Q', where Q is the quenching factor
of the ionization yield. To measure Q', a precise EDELWEISS measurement of Q/Q'
is combined with values of Q obtained from a review of all available
measurements of this quantity in tagged neutron beam experiments. The
systematic uncertainties associated with this method to evaluate Q' are
discussed in detail. For recoil energies between 20 and 100 keV, the resulting
heat quenching factor is Q' = 0.91+-0.03+-0.04, where the two errors are the
contributions from the Q and Q/Q' measurements, respectively. The present
compilation of Q values and evaluation of Q' represent one of the most precise
determinations of the absolute energy scale for any detector used in direct
searches for dark matter.
[21]
oai:arXiv.org:astro-ph/0512120 [pdf] - 78320
Critical revision of the ZEPLIN-I sensitivity to WIMP interactions
Benoit, A.;
Chapellier, M.;
Chardin, G.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Jochum, J.;
de Lesquen, A.;
Nollez, G.;
Proebst, F.;
Seidel, W.
Submitted: 2005-12-05, last modified: 2006-04-19
The ZEPLIN collaboration has recently published its first result presenting a
maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of
$\approx$ 60 GeV. The analysis is based on a discrimination method using the
different time distribution of scintillation light generated in electron recoil
and nuclear recoil interactions. We show that the methodology followed both for
the calibration of the ZEPLIN-I detector response and for the estimation of the
discrimination power is not reliable enough to claim any background
discrimination at the present stage. The ZEPLIN-I sensitivity appears then to
be in the order of 10$^{-3}$ picobarn, three orders of magnitude above the
claimed 1.1 10$^{-6}$ picobarn.
[22]
oai:arXiv.org:astro-ph/0503265 [pdf] - 71647
Final results of the EDELWEISS-I dark matter search with cryogenic
heat-and-ionization Ge detectors
Sanglard, V.;
Benoit, A.;
Berge, L.;
Blumer, J.;
Broniatowski, A.;
Censier, B.;
Chabert, L.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
Collin, S.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Drain, D.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Fiorucci, S.;
Gascon, J.;
Gerbier, G.;
Gerlic, E.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Herve, S.;
Horn, M.;
Juillard, A.;
Karolak, M.;
Kikuchi, C.;
de Lesquen, A.;
Luca, M.;
Mallet, J.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Schoeffel, L.;
Stern, M.;
Vagneron, L.;
Villar, V.
Submitted: 2005-03-11, last modified: 2005-05-26
The final results of the EDELWEISS-I dark matter search using cryogenic
heat-and-ionization Ge detectors are presented. The final data sample
corresponds to an increase by a factor five in exposure relative to the
previously published results. A recoil energy threshold of 13 keV or better was
achieved with three 320g detectors working simultaneously over four months of
stable operation. Limits on the spin-independent cross-section for the
scattering of a WIMP on a nucleon are derived from an accumulated fiducial
exposure of 62 kg.d.
[23]
oai:arXiv.org:astro-ph/0412061 [pdf] - 69465
Sensitivity of the EDELWEISS WIMP search to spin-dependent interactions
Benoit, A.;
Berge, L.;
Bluemer, J.;
Broniatowski, A.;
Censier, B.;
Chabert, L.;
Chapellier, M.;
Chardin, G.;
Collin, S.;
De Jesus, M.;
Deschamps, H.;
Di Stefano, P.;
Dolgorouky, Y.;
Drain, D.;
Dumoulin, L.;
Eitel, K.;
Fesquet, M.;
Fiorucci, S.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Gros, M.;
Gumbsheimer, R.;
Horn, M.;
Juillard, A.;
De Lesquen, A.;
Luca, M.;
Mallet, J.;
Marnieros, S.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Razeti, M.;
Sanglard, V.;
Schoeffel, L.;
Stern, M.;
Villar, V.
Submitted: 2004-12-02, last modified: 2005-04-19
The EDELWEISS collaboration is searching for WIMP dark matter using natural
Ge cryogenic detectors. The whole data set of the first phase of the experiment
contains a fiducial exposure of 4.8 kg.day on Ge-73, the naturally present
(7.8%), high-spin Ge isotope. The sensitivity of the experiment to the
spin-dependent WIMP-nucleon interactions is evaluated using the
model-independent framework proposed by Tovey et al.
[24]
oai:arXiv.org:astro-ph/0504241 [pdf] - 72338
Direct search for WIMP dark matter
Submitted: 2005-04-11
We will review the experimental aspects of the direct search for WIMP dark
matter. In thin search, one looks in a terrestrial target for nuclear recoils
produced by the impacts with WIMPs from the galatic halo. After describing the
different search strategies and review the currently running experiments and
the prospects of future experiments
[25]
oai:arXiv.org:astro-ph/0310657 [pdf] - 60320
Calibration of the EDELWEISS Cryogenic Heat-and-ionisation Germanium
Detectors for Dark Matter Search
The EDELWEISS Collaboration;
Martineau, O.;
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chabert, L.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Gerlic, E.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Herve, S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Mirabolfathi, N.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Riccio, C.;
Sanglard, V.;
Schoeffel, L.;
Stern, M.;
Vagneron, L.
Submitted: 2003-10-22
Several aspects of the analysis of the data obtained with the cryogenic
heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search
experiment are presented. Their calibration, the determination of their energy
threshold, fiducial volume and nuclear recoil acceptance are detailed.
[26]
oai:arXiv.org:astro-ph/0212491 [pdf] - 53881
SICANE: a Detector Array for the Measurement of Nuclear Recoil Quenching
Factors using Monoenergetic Neutron Beam
Simon, E.;
Berge, L.;
Broniatowski, A.;
Bouvier, R.;
Chambon, B.;
De Jesus, M.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Hadjout, J. P.;
Juillard, A.;
Martineau, O.;
Pastor, C.;
Stern, M.;
Vagneron, L.
Submitted: 2002-12-20
SICANE is a neutron scattering multidetector facility for the determination
of the quenching factor (ratio of the response to nuclear recoils and to
electrons) of cryogenic detectors used in direct WIMP searches. Well collimated
monoenergetic neutron beams are obtained with inverse (p,n) reactions. The
facility is described, and results obtained for the quenching factors of
scintillation in NaI(Tl) and of heat and ionization in Ge are presented.
[27]
oai:arXiv.org:astro-ph/0206271 [pdf] - 49902
Improved Exclusion Limits from the EDELWEISS WIMP Search
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chabert, L.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Gerlic, E.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Herve, S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Riccio, C.;
Sanglard, V.;
Stern, M.;
Vagneron, L.
Submitted: 2002-06-17
The EDELWEISS experiment has improved its sensitivity for the direct search
for WIMP dark matter. In the recoil energy range relevant for WIMP masses below
10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a
heat-and-ionization cryogenic Ge detector operated in the low-background
environment of the Laboratoire Souterrain de Modane in the Frejus Tunnel,
during an effective exposure of 7.4 kg.days. This result is combined with the
previous EDELWEISS data to derive a limit on the cross-section for
spin-independent interaction of WIMPs and nucleons as a function of WIMP mass,
using standard nuclear physics and astrophysical assumptions. This limit
excludes at more than 99.8%CL a WIMP candidate with a mass of 44 GeV/c2 and a
cross-section of 5.4 x 10-6 pb, as reported by the DAMA collaboration. A first
sample of supersymmetric models are also excluded at 90%CL.
[28]
oai:arXiv.org:astro-ph/0205023 [pdf] - 49097
320g Ionization-Heat Cryogenic Detector for Dark Matter Search in the
EDELWEISS Experiment
Martineau, O.;
Chapellier, M.;
Chardin, G.;
De Jesus, M.;
Gascon, J.;
Herve, S.;
Juillard, A.;
Loidl, M.;
Navick, X-F.;
Nollez, G.
Submitted: 2002-05-02
The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge
detector operated in a low-background environment in the Laboratoire Souterrain
de Modane for direct WIMP detection. This detector presents an increase of more
than 4 times the mass of previous detectors. Calibrations of this detector are
used to determine its energy resolution and fiducial volume, and to optimize
the detector design for the 1kg phase of the EDELWEISS-I experiment. Analysis
of the calibrations and characteristics of a first series of 320g-detectors are
presented.
[29]
oai:arXiv.org:astro-ph/0106094 [pdf] - 173739
First Results of the EDELWEISS WIMP Search using a 320 g
Heat-and-Ionization Ge Detector
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Mosca, L.;
Miramonti, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Stern, M.;
Vagneron, L.
Submitted: 2001-06-06
The EDELWEISS collaboration has performed a direct search for WIMP dark
matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a
low-background environment in the Laboratoire Souterrain de Modane. No nuclear
recoils are observed in the fiducial volume in the 30-200 keV energy range
during an effective exposure of 4.53 kg.days. Limits for the cross-section for
the spin-independent interaction of WIMPs and nucleons are set in the framework
of the Minimal Supersymmetric Standard Model (MSSM). The central value of the
signal reported by the experiment DAMA is excluded at 90% CL.
[30]
oai:arXiv.org:astro-ph/0104192 [pdf] - 1943551
Dark Matter Search in the EDELWEISS experiment
Juillard, A.;
Benoit, A.;
Berge, L.;
Bonnevaux, A.;
Bouvier, R.;
Broniatowski, A.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
Cluzel, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
De Lesquen, A.;
Loidl, M.;
Loiseau, D.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Mosca, L.;
Navick, X-F.;
Nollez, G.;
Pari, P.;
Pastor, C.;
Simon, E.;
Stern, M.;
Vagneron, L.
Submitted: 2001-04-11
The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat
and ionisation read-out to identify nuclear recoils induced by elastic
collisions with WIMPs from the galactic halo. Preliminary results obtained with
320g bolometers are described. After a few weeks of data taking, data
accumulated with one of these detectors already allow to reach the upper part
of the DAMA region. Prospects for the present run and the second stage of the
experiment, EDELWEISS-II, using an innovative reversed cryostat allowing data
taking with 100 detectors, are briefly described.
[31]
oai:arXiv.org:astro-ph/0101204 [pdf] - 1507854
Dark Matter Search in the Edelweiss Experiment
Chapellier, M.;
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Hadjout, J. P.;
Herve, S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Miramonti, L.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Pastor, C.;
Simon, E.;
Stern, M.;
Vagneron, L.
Submitted: 2001-01-12, last modified: 2001-02-23
Preliminary results obtained with 320g bolometers with simultaneous
ionization and heat measurements are described. After a few weeks of data
taking, data accumulated with one of these detectors are beginning to exclude
the upper part of the DAMA region. Prospects for the present run and the second
stage of the experiment, EDELWEISS-II, using an innovative reversed cryostat
allowing data taking with 100 detectors, are briefly described.
[32]
oai:arXiv.org:astro-ph/0101454 [pdf] - 40592
The EDELWEISS Experiment : Status and Outlook
Gascon, J.;
Benoit, A.;
Bonnevaux, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
Cluzel, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Herve, J. P. Hadjout S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Miramonti, L.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Pastor, C.;
Simon, E.;
Stern, M.;
Vagneron, L.;
Gascon, Jules
Submitted: 2001-01-25, last modified: 2001-02-06
The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat
and ionisation read- out to identify nuclear recoils induced by elastic
collisions with WIMPs from the galactic halo. Results from the operation of 70
g and 320 g Ge detectors in the low-background environment of the Modane
Underground Laboratory (LSM) are presented.
[33]
oai:arXiv.org:astro-ph/0101454 [pdf] - 40592
The EDELWEISS Experiment : Status and Outlook
Gascon, J.;
Benoit, A.;
Bonnevaux, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
Cluzel, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Gerbier, G.;
Goldbach, C.;
Goyot, M.;
Gros, M.;
Herve, J. P. Hadjout S.;
Juillard, A.;
de Lesquen, A.;
Loidl, M.;
Mallet, J.;
Marnieros, S.;
Martineau, O.;
Mirabolfathi, N.;
Miramonti, L.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Pastor, C.;
Simon, E.;
Stern, M.;
Vagneron, L.;
Gascon, Jules
Submitted: 2001-01-25, last modified: 2001-02-06
The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat
and ionisation read- out to identify nuclear recoils induced by elastic
collisions with WIMPs from the galactic halo. Results from the operation of 70
g and 320 g Ge detectors in the low-background environment of the Modane
Underground Laboratory (LSM) are presented.
[34]
oai:arXiv.org:astro-ph/0004308 [pdf] - 35667
Background discrimination capabilities of a heat and ionization
germanium cryogenic detector
Di Stefano, P.;
Berge, L.;
Chambon, B.;
Chapellier, M.;
Chaumont, J.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Drain, D.;
Dumoulin, L.;
Forget, P.;
Garoche, P.;
Gascon, J.;
Goldbach, C.;
L'Hote, D.;
Mallet, J.;
Mangin, J.;
Marnieros, S.;
Miramonti, L.;
Mosca, L.;
Navick, X. -F.;
Nollez, G.;
Pari, P.;
Pecourt, S.;
Simon, E.;
Stab, L.;
Torre, J. -P.;
Tourbot, R.;
Yvon, D.
Submitted: 2000-04-21
The discrimination capabilities of a 70 g heat and ionization Ge bolometer
are studied. This first prototype has been used by the EDELWEISS Dark Matter
experiment, installed in the Laboratoire Souterrain de Modane, for direct
detection of WIMPs. Gamma and neutron calibrations demonstrate that this type
of detector is able to reject more than 99.6% of the background while retaining
95% of the signal, provided that the background events distribution is not
biased towards the surface of the Ge crystal. However, the 1.17 kg.day of data
taken in a relatively important radioactive environment show an extra
population slightly overlapping the signal. This background is likely due to
interactions of low energy photons or electrons near the surface of the
crystal, and is somewhat reduced by applying a higher charge-collecting inverse
bias voltage (-6 V instead of -2 V) to the Ge diode. Despite this
contamination, more than 98% of the background can be rejected while retaining
50% of the signal. This yields a conservative upper limit of 0.7
event.day^{-1}.kg^{-1}.keV^{-1}_{recoil} at 90% confidence level in the 15-45
keV recoil energy interval; the present sensitivity appears to be limited by
the fast ambient neutrons. Upgrades in progress on the installation are
summarized.
[35]
oai:arXiv.org:astro-ph/0002462 [pdf] - 34805
Event categories in the EDELWEISS WIMP search experiment
Benoit, A.;
Berge, L.;
Broniatowski, A.;
Chambon, B.;
Chapellier, M.;
Chardin, G.;
Charvin, P.;
De Jesus, M.;
Di Stefano, P.;
Drain, D.;
Dumoulin, L.;
Garoche, P.;
Gascon, J.;
Goldbach, C.;
Gros, M.;
Juillard, A.;
de Lesquen, A.;
L'Hote, D.;
Mallet, L.;
Mangin, J.;
Marnieros, S.;
Mirabolfathi, N.;
Miramonti, L.;
Mosca, L.;
Navick, X-F.;
Nollez, G.;
Pari, P.;
Pecourt, S.;
Simon, E.;
Stern, M.;
Torre, J-P.
Submitted: 2000-02-24
Four categories of events have been identified in the EDELWEISS-I dark matter
experiment using germanium cryogenic detectors measuring simultaneously charge
and heat signals. These categories of events are interpreted as electron and
nuclear interactions occurring in the volume of the detector, and electron and
nuclear interactions occurring close to the surface of the detectors(10-20 mu-m
of the surface). We discuss the hypothesis that low energy surface nuclear
recoils,which seem to have been unnoticed by previous WIMP searches, may
provide an interpretation of the anomalous events recorded by the UKDMC and
Saclay NaI experiments. The present analysis points to the necessity of taking
into account surface nuclear and electron recoil interactions for a reliable
estimate of background rejection factors.