Normalized to: Garde, G.
[1]
oai:arXiv.org:1911.04917 [pdf] - 2046326
KISS: a spectrometric imager for millimetre cosmology
Fasano, A.;
Aguiar, M.;
Benoit, A.;
Bideaud, A.;
Bourrion, O.;
Calvo, M.;
Catalano, A.;
de Taoro, A. P.;
Garde, G.;
Gomez, A.;
Renasco, M. F. Gomez;
Goupy, J.;
Hoarau, C.;
Hoyland, R.;
Macías-Pérez, J. F.;
Marpaud, J.;
Monfardini, A.;
Pisano, G.;
Ponthieu, N.;
Martín, J. A. Rubiño;
Tourres, D.;
Tucker, C.;
Beelen, A.;
Bres, G.;
De Petris, M.;
de Bernardis, P.;
Lagache, G.;
Marton, M.;
Rebolo, R.;
Roudier, S.
Submitted: 2019-11-12, last modified: 2020-01-23
Clusters of galaxies are used to map the large-scale structures in the
universe and as probe of universe evolution. They can be observed through the
Sunyaev-Zel'dovich (SZ) effect. At this respect the spectro-imaging at low
resolution frequency is an important tool, today, for the study of cluster of
galaxies. We have developed KISS (KIDs-Interferometer-Spectrum-Survey), a
spectrometric imager dedicated to the secondary anisotropies of the Cosmic
Microwave Background (CMB). The multi-frequency approach permits to improve the
component separation with respect to predecessor experiments. In this paper,
firstly, we provide a description of the scientific context and the state of
the art of SZ observations. Secondly, we describe the KISS instrument. Finally,
we show preliminary results of the ongoing commissioning campaign.
[2]
oai:arXiv.org:1911.13148 [pdf] - 2026468
The KISS experiment
Fasano, A.;
Aguiar, M.;
Benoit, A.;
Bideaud, A.;
Bourrion, O.;
Calvo, M.;
Catalano, A.;
de Taoro, A. P.;
Garde, G.;
Gomez, A.;
Renasco, M. F. Gomez;
Goupy, J.;
Hoarau, C.;
Hoyland, R.;
Macías-Pérez, J. F.;
Marpaud, J.;
Monfardini, A.;
Pisano, G.;
Ponthieu, N.;
Martín, J. A. Rubiño;
Tourres, D.;
Tucker, C.;
Beelen, A.;
Bres, G.;
De Petris, M.;
de Bernardis, P.;
Lagache, G.;
Lamagna, L.;
Luzzi, G.;
Marton, M.;
Masi, S.;
Rebolo, R.;
Roudier, S.
Submitted: 2019-11-29
Mapping millimetre continuum emission has become a key issue in modern
multi-wavelength astrophysics. In particular, spectrum-imaging at low frequency
resolution is an asset for characterizing the clusters of galaxies via the
Sunyaev Zeldovich (SZ) effect. In this context, we have built a ground-based
spectrum-imager named KIDs Interferometer Spectrum Survey (KISS). This
instrument is based on two 316-pixel arrays of Kinetic Inductance Detectors
(KID) cooled to 150 mK by a custom dilution refrigerator-based cryostat. By
using Ti-Al and Al absorbers, we can cover a wide frequency range between 80
and 300 GHz. In order to preserve a large instantaneous Field of View (FoV) 1
degree the spectrometer is based on a Fourier Transform interferometer. This
represents a technological challenge due to the fast scanning speed that is
needed to overcome the effects of background atmospheric fluctuations. KISS is
installed at the QUIJOTE 2.25 m telescope in Tenerife since February 2019 and
is currently in its commissioning phase. In this proceeding we present an
overview of the instrument and the latest results.
[3]
oai:arXiv.org:1712.04003 [pdf] - 1666796
The NIKA2 instrument at 30-m IRAM telescope: performance and results
Catalano, A.;
Adam, R.;
Ade, P. A. R.;
P.;
André;
Aussel, H.;
Beelen, A.;
Benoit, A.;
Bideaud, A.;
Billot, N.;
Bourrion, O.;
Calvo, M.;
Comis, B.;
De Petris, M.;
Désert, F. -X.;
Doyle, S.;
Driessen, E. F. C.;
Goupy, J.;
Kramer, C.;
Lagache, G.;
Leclercq, S.;
Lestrade, J. -F.;
Macìas-Pérez, J. F.;
Mauskopf, P.;
Mayet, F.;
Monfardini, A.;
Pascale, E.;
Perotto, L.;
Pisano, G.;
Ponthieu, N.;
Revéret, V.;
Ritacco, A.;
Romero, C.;
Roussel, H.;
Ruppin, F.;
Schuster, K.;
Sievers, A.;
Triqueneaux, S.;
Tucker, C.;
Zylka, R.;
Barria, E.;
Bres, G.;
Camus, P.;
Chanthib, P.;
Donnier-Valentin, G.;
Exshaw, O.;
Garde, G.;
Gerardin, A.;
Leggeri, J. -P.;
Levy-Bertrand, F.;
Guttin, C.;
Hoarau, C.;
Grollier, M.;
Mocellin, J. -L.;
Pont, G.;
Rodenas, H.;
Tissot, O.;
Galvez, G.;
John, D.;
Ungerechts, H.;
Sanchez, S.;
Mellado, P.;
Munoz, M.;
Pierfederici, F.;
Penalver, J.;
Navarro, S.;
Bosson, G.;
Bouly, J. -L.;
Bouvier, J.;
Geraci, C.;
Li, C.;
Menu, J.;
Ponchant, N.;
Roni, S.;
Roudier, S.;
Scordillis, J. P.;
Tourres, D.;
Vescovi, C.;
Barbier, A.;
Billon-Pierron, D.;
Adane, A.;
Andrianasolo, A .;
Bracco, A.;
Coiffard, G.;
Evans, R.;
Maury, A.;
Rigby, A.
Submitted: 2017-12-11, last modified: 2018-02-04
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and
commissioning a millimetre camera on the IRAM 30 m telescope. It is a dual-band
camera operating with three frequency multiplexed kilo-pixels arrays of Lumped
Element Kinetic Inductance Detectors (LEKID) cooled at 150 mK, designed to
observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and
2 mm). NIKA2 is today an IRAM resident instrument for millimetre astronomy,
such as Intra Cluster Medium from intermediate to distant clusters and so for
the follow-up of Planck satellite detected clusters, high redshift sources and
quasars, early stages of star formation and nearby galaxies emission. We
present an overview of the instrument performance as it has been evaluated at
the end of the commissioning phase.
[4]
oai:arXiv.org:1706.01070 [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter
searches
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Maisonobe, R.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.;
Zolotarova, A.
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the
EDELWEISS-III array of cryogenic germanium detectors for direct dark matter
searches. The experimental setup and the FID (Fully Inter-Digitized) detector
array is described, as well as the efficiency of the double measurement of heat
and ionization signals in background rejection. For the whole set of 24 FID
detectors used for coincidence studies, the baseline resolutions for the
fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the
baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM).
The response to nuclear recoils as well as the very good discrimination
capability of the FID design has been measured with an AmBe source. The surface
$\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times
10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source,
the rejection of bulk $\gamma$-ray events has been demonstrated using
$\gamma$-calibrations with $^{133}$Ba sources leading to a value of
$R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels
of natural radioactivity measured in the detector array are shown as the rate
of single $\gamma$ background. The fiducial volume fraction of the FID
detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$
using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The
stability and uniformity of the detector response is also discussed. The
achieved resolutions, thresholds and background levels of the upgraded
EDELWEISS-III detectors in their setup are thus well suited to the direct
search of WIMP dark matter over a large mass range.
[5]
oai:arXiv.org:1603.05120 [pdf] - 1403150
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
De Jésus, M.;
Jin, Y.;
Jokisch, S.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D. V.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2016-03-16, last modified: 2016-05-09
We present the results of a search for elastic scattering from galactic dark
matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30
GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an
array of 800 g Germanium bolometers equipped with a set of interleaved
electrodes with full surface coverage. We searched specifically for $\sim
2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an
illustration the number of observed events in the search for 5 (resp. 20)
GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1
(resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times
10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering
cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a
41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP
search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints
of WIMP signals from some recent experiments, thus confirming results obtained
with different detection techniques.
[6]
oai:arXiv.org:1601.02774 [pdf] - 1392791
The NIKA2 instrument, a dual-band kilopixel KID array for millimetric
astronomy
Calvo, M.;
Benoit, A.;
Catalano, A.;
Goupy, J.;
Monfardini, A.;
Ponthieu, N.;
Barria, E.;
Bres, G.;
Grollier, M.;
Garde, G.;
Leggeri, J. -P.;
Pont, G.;
Triqueneaux, S.;
Adam, R.;
Bourrion, O.;
Macías-Pérez, J. -F.;
Rebolo, M.;
Ritacco, A.;
Scordilis, J. -P.;
Tourres, D.;
Vescovi, C.;
Désert, F. -X.;
Adane, A.;
Coiffard, G.;
Leclercq, S.;
Doyle, S.;
Mauskopf, P.;
Tucker, C.;
Ade, P.;
André, P.;
Beelen, A.;
Belier, B.;
Bideaud, A.;
Billot, N.;
Comis, B.;
D'Addabbo, A.;
Kramer, C.;
Martino, J.;
Mayet, F.;
Pajot, F.;
Pascale, E.;
Perotto, L.;
Revéret, V.;
Rodriguez, L.;
Savini, G.;
Schuster, K.;
Sievers, A.;
Zylka, R.
Submitted: 2016-01-12
NIKA2 (New IRAM KID Array 2) is a camera dedicated to millimeter wave
astronomy based upon kilopixel arrays of Kinetic Inductance Detectors (KID).
The pathfinder instrument, NIKA, has already shown state-of-the-art detector
performance. NIKA2 builds upon this experience but goes one step further,
increasing the total pixel count by a factor $\sim$10 while maintaining the
same per pixel performance. For the next decade, this camera will be the
resident photometric instrument of the Institut de Radio Astronomie
Millimetrique (IRAM) 30m telescope in Sierra Nevada (Spain). In this paper we
give an overview of the main components of NIKA2, and describe the achieved
detector performance. The camera has been permanently installed at the IRAM 30m
telescope in October 2015. It will be made accessible to the scientific
community at the end of 2016, after a one-year commissioning period. When this
happens, NIKA2 will become a fundamental tool for astronomers worldwide.
[7]
oai:arXiv.org:1302.7112 [pdf] - 633724
Muon-induced background in the EDELWEISS dark matter search
The EDELWEISS collaboration;
Schmidt, B.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Bergé, L.;
Bergmann, T.;
Blümer, J.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chapellier, M.;
Charlieux, F.;
Collin, S.;
Coulter, P.;
Cox, G. A.;
Crauste, O.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hehn, L.;
Henry, S.;
Hervé, S.;
Heuermann, G.;
Juillard, A.;
Kluck, H.;
Kozlov, V. Y.;
Kleifges, M.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nieder, H.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Siebenborn, B.;
Tcherniakhovski, D.;
Torrentó-Coello, A. S.;
Vagneron, L.;
Walker, R. J.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2013-02-28
A dedicated analysis of the muon-induced background in the EDELWEISS dark
matter search has been performed on a data set acquired in 2009 and 2010. The
total muon flux underground in the Laboratoire Souterrain de Modane (LSM) was
measured to be $\Phi_{\mu}=(5.4\pm 0.2 ^{+0.5}_{-0.9})$\,muons/m$^2$/d. The
modular design of the muon-veto system allows the reconstruction of the muon
trajectory and hence the determination of the angular dependent muon flux in
LSM. The results are in good agreement with both MC simulations and earlier
measurements. Synchronization of the muon-veto system with the phonon and
ionization signals of the Ge detector array allowed identification of
muon-induced events. Rates for all muon-induced events $\Gamma^{\mu}=(0.172 \pm
0.012)\, \rm{evts}/(\rm{kg \cdot d})$ and of WIMP-like events $\Gamma^{\mu-n} =
0.008^{+0.005}_{-0.004}\, \rm{evts}/(\rm{kg \cdot d})$ were extracted. After
vetoing, the remaining rate of accepted muon-induced neutrons in the
EDELWEISS-II dark matter search was determined to be $\Gamma^{\mu-n}_{\rm
irred} < 6\cdot 10^{-4} \, \rm{evts}/(\rm{kg \cdot d})$ at 90%\,C.L. Based on
these results, the muon-induced background expectation for an anticipated
exposure of 3000\,\kgd\ for EDELWEISS-3 is $N^{\mu-n}_{3000 kg\cdot d} < 0.6$
events.