Garcıa-Marın, Macarena
Normalized to: Garcıa-Marın, M.
2 article(s) in total. 15 co-authors, from 1 to 2 common article(s). Median position in authors list is 5,0.
[1]
oai:arXiv.org:1508.02362 [pdf] - 1264204
The Mid-Infrared Instrument for the James Webb Space Telescope, VII: The
MIRI Detectors
Rieke, G. H.;
Ressler, M. E.;
Morrison, Jane E.;
Bergeron, L.;
Bouchet, Patrice;
Garcıa-Marın, Macarena;
Greene, T. P.;
Regan, M. W.;
Sukhatme, K. G.;
Walker, Helen
Submitted: 2015-08-10
The MIRI Si:As IBC detector arrays extend the heritage technology from the
Spitzer IRAC arrays to a 1024 x 1024 pixel format. We provide a short
discussion of the principles of operation, design, and performance of the
individual MIRI detectors, in support of a description of their operation in
arrays provided in an accompanying paper (Ressler et al. (2015)). We then
describe modeling of their response. We find that electron diffusion is an
important component of their performance, although it was omitted in previous
models. Our new model will let us optimize the bias voltage while avoiding
avalanche gain. It also predicts the fraction of the IR-active layer that is
depleted (and thus contributes to the quantum efficiency) as signal is
accumulated on the array amplifier. Another set of models accurately predicts
the nonlinearity of the detector-amplifier unit and has guided determination of
the corrections for nonlinearity. Finally, we discuss how diffraction at the
interpixel gaps and total internal reflection can produce the extended
cross-like artifacts around images with these arrays at short wavelengths, ~ 5
microns. The modeling of the behavior of these devices is helping optimize how
we operate them and also providing inputs to the development of the data
pipeline.
[2]
oai:arXiv.org:1508.02427 [pdf] - 1264209
The Mid-Infrared Instrument for the James Webb Space Telescope, IX:
Predicted Sensitivity
Submitted: 2015-08-10
We present an estimate of the performance that will be achieved during on
orbit operations of the JWST Mid Infrared Instrument, MIRI. The efficiency of
the main imager and spectrometer systems in detecting photons from an
astronomical target are presented, based on measurements at sub-system and
instrument level testing, with the end-to-end transmission budget discussed in
some detail. The brightest target fluxes that can be measured without
saturating the detectors are provided. The sensitivity for long duration
observations of faint sources is presented in terms of the target flux required
to achieve a signal to noise ratio of 10 after a 10,000 second observation. The
algorithms used in the sensitivity model are presented, including the
understanding gained during testing of the MIRI Flight Model and flight-like
detectors.