Normalized to: Gannon, R.
[1]
oai:arXiv.org:1902.09640 [pdf] - 1838469
Design and Bolometer Characterization of the SPT-3G First-year Focal
Plane
Everett, W.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Austermann, J. E.;
Avva, J. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T.;
Chang, C. L.;
Cliche, J. F.;
Cukierman, A.;
Denison, E. V.;
de Haan, T.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Foster, A.;
Gannon, R. N.;
Gilbert, A.;
Groh, J. C.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holzapfel, W. L.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Khaire, T.;
Kofman, A. M.;
Korman, M.;
Kubik, D.;
Kuhlmann, S.;
Kuo, C. L.;
Lee, A. T.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Pearson, J.;
Posada, C. M.;
Rahlin, A.;
Ruhl, J. E.;
Saunders, L. J.;
Sayre, J. T.;
Shirley, I.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Story, K. T.;
Suzuki, A.;
Tang, Q. Y.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-02-25
During the austral summer of 2016-17, the third-generation camera, SPT-3G,
was installed on the South Pole Telescope, increasing the detector count in the
focal plane by an order of magnitude relative to the previous generation.
Designed to map the polarization of the cosmic microwave background, SPT-3G
contains ten 6-in-hexagonal modules of detectors, each with 269 trichroic and
dual-polarization pixels, read out using 68x frequency-domain multiplexing.
Here we discuss design, assembly, and layout of the modules, as well as early
performance characterization of the first-year array, including yield and
detector properties.
[2]
oai:arXiv.org:1805.03219 [pdf] - 1679898
Optical Characterization of the SPT-3G Focal Plane
Pan, Zhaodi;
Ade, Peter;
Ahmed, Zeeshan;
Adam, Anderson;
Austermann, Jason;
Avva, Jessica;
Thakur, Ritoban Basu;
Amy, Bender;
Benson, Bradford;
Carlstrom, John;
Carter, Faustin;
Cecil, Thomas;
Chang, Clarence;
Cliche, Jean-Francois;
Cukierman, Ariel;
Denison, Edward;
de Haan, Tijmen;
Ding, Junjia;
Dobbs, Matt;
Dutcher, Daniel;
Everett, Wendeline;
Foster, Allen;
Gannon, Renae;
Gilbert, Adam;
Groh, John;
Halverson, Nils;
Harke-Horsemann, Angelina;
Harrington, Nicholas;
Henning, Jaosn;
Hilton, Gene;
Holzapfel, William;
Huang, Nicholas;
Irwin, Kent;
Jeong, Oliver;
Jonas, Michalle;
Khaire, Trupti;
Kofman, Anna;
Korman, Milo;
Kubik, Donna;
Kuhlmann, Steve;
Kuo, Chaolin;
Lee, Adrian;
Lowitz, Amy;
Meyer, Stephan;
Michalik, Daniel;
Montgomery, Joshua;
Nadolski, Andrew;
Natoli, Tyler;
Nguyen, Hogan;
Noble, Gavin;
Novosad, Valentyn;
Padin, Stephan;
Pearson, John;
Posada, Chrystian;
Rahlin, Alexandra;
Ruhl, John;
Saunders, Lauren;
Sayre, James;
Shirley, Ian;
Shirokoff, Erik;
Smecher, Graeme;
Sobrin, Joshua;
Stark, Antony;
Story, Kyle;
Suzuki, Aritoki;
Tang, Qingyang;
Thompson, Keith;
Tucker, Carole;
Vale, Leila;
Vanderlinde, Keith;
Vieira, Joaquin;
Wang, Gensheng;
Whitehorn, Nathan;
Yefremenko, Volodymyr;
Yoon, Ki Won;
Young, Matt
Submitted: 2018-05-08
The third-generation South Pole Telescope camera is designed to measure the
cosmic microwave background across three frequency bands (95, 150 and 220 GHz)
with ~16,000 transition-edge sensor (TES) bolometers. Each multichroic pixel on
a detector wafer has a broadband sinuous antenna that couples power to six
TESs, one for each of the three observing bands and both polarization
directions, via lumped element filters. Ten detector wafers populate the focal
plane, which is coupled to the sky via a large-aperture optical system. Here we
present the frequency band characterization with Fourier transform
spectroscopy, measurements of optical time constants, beam properties, and
optical and polarization efficiencies of the focal plane. The detectors have
frequency bands consistent with our simulations, and have high average optical
efficiency which is 86%, 77% and 66% for the 95, 150 and 220 GHz detectors. The
time constants of the detectors are mostly between 0.5 ms and 5 ms. The beam is
round with the correct size, and the polarization efficiency is more than 90%
for most of the bolometers