Normalized to: Gangapshev, A.
[1]
oai:arXiv.org:1706.09378 [pdf] - 1598071
Towards a medium-scale axion helioscope and haloscope
Anastassopoulos, V.;
Avignone, F.;
Bykov, A.;
Cantatore, G.;
Cetin, S. A.;
Derbin, A.;
Drachnev, I.;
Djilkibaev, R.;
Eremin, V.;
Fischer, H.;
Gangapshev, A.;
Gardikiotis, A.;
Gninenko, S.;
Golubev, N.;
Hoffmann, D. H. H.;
Karuza, M.;
Kravchuk, L.;
Libanov, M.;
Lutovinov, A.;
Maroudas, M.;
Matveev, V.;
Molkov, S.;
Muratova, V.;
Pantuev, V.;
Pavlinsky, M.;
Ptitsyna, K.;
Rubtsov, G.;
Semenov, D.;
Sikivie, P.;
Spiridonov, A.;
Tinyakov, P.;
Tkachev, I.;
Troitsky, S.;
Unzhakov, E.;
Zioutas, K.
Submitted: 2017-06-28, last modified: 2017-11-08
We discuss the physics case for and the concept of a medium-scale axion
helioscope with sensitivities in the axion-photon coupling a few times better
than CERN Axion Solar Telescope (CAST). Search for an axion-like particle with
these couplings is motivated by several persistent astrophysical anomalies. We
present early conceptual design, existing infrastructure, projected sensitivity
and timeline of such a helioscope (Troitsk Axion Solar Telescope Experiment,
TASTE) to be constructed in the Institute for Nuclear Research, Troitsk,
Russia. The proposed instrument may be also used for the search of dark-matter
halo axions.
[2]
oai:arXiv.org:1512.05939 [pdf] - 1914607
Study of the characteristics of SiPMs matrix as a photosensor for the
scintillation detectors
Submitted: 2015-12-18
The matrices formed of silicon photomultipliers (SiPMs) are very promising
photosensors for the scintillation detectors. The use of SiPM matrices with
appropriate optical collector gives, in principle, a possibility to do a
snapshot of glowing track of charged particle traversing a scintillator. The
prototype of such scintillation detector is under development now in INR RAS.
The preliminary results of characterization study of the matrix
ArrayC-60035-64P-PCB (SensL company) for the prototype of such detector are
presented.
[3]
oai:arXiv.org:1505.01752 [pdf] - 1521139
Results of a search for daily and annual variations of the Po-214
half-life at the two year observation period
Submitted: 2015-05-07
The brief description of installation TAU-2 intended for long-term monitoring
of the half-life value $\tau$ ($\tau_{1/2}$) of the $^{214}$Po is presented.
The methods of measurement and processing of collected data are reported. The
results of analysis of time series values $\tau$ with different time step are
presented. Total of measurement time was equal to 590 days. Averaged value of
the $^{214}$Po half-life was obtained $\tau=163.46\pm0.04$ $\mu$s. The annual
variation with an amplitude $A=(8.9\pm2.3)\cdot10^{-4}$, solar-daily variation
with an amplitude $A_{So}=(7.5\pm1.2)\cdot10^{-4}$, lunar-daily variation with
an amplitude $A_L=(6.9\pm2.0)\cdot10^{-4}$ and sidereal-daily variation with an
amplitude $A_S=(7.2\pm1.2)\cdot10^{-4}$ were found in a series of $\tau$
values. The maximal values of amplitude are observed at the moments when the
projections of the installation Earth location velocity vectors toward the
source of possible variation achieve its maximal magnitudes.