Normalized to: Gandolfi, G.
[1]
oai:arXiv.org:astro-ph/0305359 [pdf] - 56832
X/gamma-ray measurements of the faint GRB 020321
Zand, J. J. M. in 't;
Kuiper, L.;
Heise, J.;
Amati, L.;
Costa, E.;
Feroci, M.;
Frontera, F.;
Gandolfi, G.;
Nicastro, L.;
Piro, L.;
Rodriguez-Pascual, P.;
Santos-Lleo, M.;
Schartel, N.
Submitted: 2003-05-20
GRB 020321 is a faint GRB that received wide follow-up attention in X-rays
(BeppoSAX/NFI, Chandra/ACIS-S, XMM-Newton), radio (ATCA) and optical (ESO,
HST). We identify a weak X-ray afterglow by a combined study of the Chandra and
XMM-Newton observations. Its decay index of 1.2 is typical for GRB afterglows.
Inside the 4"-accurate error box there is a weak optical counterpart candidate
with a much shallower decay index.
[2]
oai:arXiv.org:astro-ph/0212298 [pdf] - 53688
A comparative study of the X-ray afterglow properties of optically
bright and dark GRBs
De Pasquale, M.;
Piro, L.;
Perna, R.;
Costa, E.;
Feroci, M.;
Gandolfi, G.;
Zand, J. in 't;
Nicastro, L.;
Frontera, F.;
Antonelli, L. A.;
Fiore, F.;
Stratta, G.
Submitted: 2002-12-12, last modified: 2002-12-13
We have examined the complete set of X-ray afterglow observations of dark and
optically bright GRBs performed by BeppoSAX until February 2001. X-ray
afterglows are detected in 90% of the cases. We do not find significant
differences in the X-ray spectral shape, in particular no higher X-ray
absorption in GRBs without optical transient (dark GRBs) compared to GRBs with
optical transient (OTGRBs). Rather, we find that the 1.6-10 keV flux of OTGRBs
is on average about 5 times larger than that of the dark GRBs. A K-S test shows
that this difference is significant at 99.8% probability. Under the assumption
that dark and OTGRB have similar spectra, this could suggest that the first are
uncaught in the optical band because they are just faint sources. In order to
test this hypothesis, we have determined the optical-to-X ray flux ratios of
the sample. OTGRBs show a remarkably narrow distribution of flux ratios, which
corresponds to an average optical-to-x spectral index 0.794\pm 0.054. We find
that, while 75% of dark GRBs have flux ratio upper limits still consistent with
those of OT GRBs, the remaining 25% are 4 - 10 times weaker in optical than in
X-rays. The significance of this result is equal to or higher than 2.6 sigma.
If this sub-population of dark GRBs were constituted by objects assimilable to
OTGRBs, they should have shown optical fluxes higher than upper limits actually
found. We discuss the possible causes of their behaviour, including a possible
occurrence in high density clouds or origin at very high redshift and a
connection with ancient, Population III stars.
[3]
oai:arXiv.org:astro-ph/0201282 [pdf] - 1456313
The bright Gamma-Ray Burst of February 10, 2000: a case study of an
optically dark GRB
Piro, L.;
Frail, D. A.;
Gorosabel, J.;
Garmire, G.;
Soffitta, P.;
Amati, L.;
Andersen, M. I.;
Antonelli, L. A.;
Berger, E.;
Frontera, F.;
Fynbo, J.;
Gandolfi, G.;
Garcia, M. R.;
Hjorth, J.;
Zand, J. in 't;
Jensen, B. L.;
Masetti, N.;
Möller, P.;
Pedersen, H.;
Pian, E.;
Wieringa, M. H.
Submitted: 2002-01-17, last modified: 2002-06-26
The gamma-ray burst GRB000210 had the highest gamma-ray peak flux of any
event localized by BeppoSAX as yet but it did not have a detected optical
afterglow. It is therefore one of the events recently classified as dark GRBs
or GHOST (GRB Hiding Optical Source Transient), whose origin is still unclear.
Chandra observations allowed us to localize this GRB within ~1" and a radio
transient was detected with the VLA. We identify the likely (P=0.01) host
galaxy of this burst at z=0.846. The X-ray spectrum of the afterglow shows
intrinsic absorption N_H=5x10**21 cm-2. The amount of dust needed to absorb the
optical flux of this object is consistent with the above HI column density,
given a dust-to-gas ratio similar to that of our Galaxy. We do not find
evidence for a partially ionized absorber expected if the absorption takes
place in a Giant Molecular Cloud. We therefore conclude that either the gas is
local to the GRB, but is condensed in small-scale high-density (n>~10**9 cm-3)
clouds, or that the GRB is located in a dusty, gas-rich region of the galaxy.
Finally, if GRB000210 lies at z>5, its X-ray absorbing medium would have to be
substantially different from that observed in GRBs with optical afterglows.
[4]
oai:arXiv.org:astro-ph/0104362 [pdf] - 42101
BeppoSAX measurements of the bright gamma-ray burst 010222
Zand, J. J. M. in 't;
Kuiper, L.;
Amati, L.;
Antonelli, L. A.;
Butler, R. C.;
Costa, E.;
Feroci, M.;
Frontera, F.;
Gandolfi, G.;
Guidorzi, C.;
Heise, J.;
Kaptein, R. G.;
Kuulkers, E.;
Nicastro, L.;
Piro, L.;
Soffitta, P.;
Tavani, M.
Submitted: 2001-04-23, last modified: 2001-06-28
We analyze the BeppoSAX measurements of the prompt and afterglow emission of
the gamma-ray burst GRB010222. Among 45 GRBs detected with the Wide Field
Cameras on BeppoSAX, the 40-700 keV fluence of (9.3+/-0.3)E-5 erg cm-2 is only
surpassed by GRB990123. In terms of the isotropic 20-2000 keV energy output of
7.8E53 erg, it ranks third of all GRBs with measured distances. Since this
burst is so bright, the data provide complete and valuable coverage up to 65 hr
after the event, except for a gap between 3.5 and 8.0 hr. The 2-10 keV flux
history shows clear signs of a break which is consistent with a break seen in
the optical, and provides supporting evidence for the achromatic nature of the
break. An explanation for the break in the context of a collimated expansion is
not straightforward. Rather, a model is favored whereby the fireball is braked
to the non-relativistic regime quickly (within a fraction of day) by a dense
1E6 cm-3 circumburst medium. This implies that, after a mild beaming
correction, GRB010222 may be the most energetic burst observed thus far. The
X-ray decay index after the break is 1.33+/-0.04, the spectral index
0.97+/-0.05. The decay is, with unprecedented accuracy, identical to that
observed in the optical.
[5]
oai:arXiv.org:astro-ph/0012318 [pdf] - 39907
Discovery of a Transient Absorption Edge in the X-ray Spectrum of GRB
990705
Amati, L.;
Frontera, F.;
Vietri, M.;
Zand, J. J. M. in't;
Soffitta, P.;
Costa, E.;
Del Sordo, S.;
Pian, E.;
Piro, L.;
Antonelli, L. A.;
Fiume, D. Dal;
Feroci, M.;
Gandolfi, G.;
Guidorzi, C.;
Heise, J.;
Kuulkers, E.;
Masetti, N.;
Montanari, E.;
Nicastro, L.;
Orlandini, M.;
Palazzi, E.
Submitted: 2000-12-14
We report the discovery of a transient equivalent hydrogen column density
with an absorption edge at ~3.8 kiloelectron volts in the spectrum of the
prompt x-ray emission of gamma-ray burst (GRB) 990705. This feature can be
satisfactorily modeled with a photoelectric absorption by a medium located at a
redshift of ~0.86 and with an iron abundance of ~75 times the solar one. The
transient behavior is attributed to the strong ionization produced in the
circumburst medium by the GRB photons. The high iron abundance points to the
existence of a burst environment enriched by a supernova along the line of
sight. The supernova explosion is estimated to have occurred about 10 years
before the burst. Our results agree with models in which GRBs originate from
the collapse of very massive stars and are preceded by a supernova event
[6]
oai:arXiv.org:astro-ph/0007280 [pdf] - 37118
X-ray afterglow detection of the short gamma-ray burst 991014
Zand, J. J. M. in 't;
Kuiper, L.;
Amati, L.;
Antonelli, L. A.;
Hurley, K.;
Coletta, A.;
Costa, E.;
Feroci, M.;
Frontera, F.;
Gandolfi, G.;
Heise, J.;
Kuulkers, E.;
Muller, J. M.;
Nicastro, L.;
Piro, L.;
Smith, M. J. S.;
Tavani, M.
Submitted: 2000-07-19
GRB 991014 is one of the shortest gamma-ray bursts detected so far with the
Wide Field Cameras aboard BeppoSAX, both in gamma-rays and X-rays. The duration
is 9.6 sec in 2-28 keV and 3.2 sec in 40 to 700 keV (as measured between the
times when 5 and 95% of the burst photons have been accumulated). We refine the
InterPlanetary Network annulus of the burst, present the detection of the X-ray
afterglow of GRB 991014 within this refined annulus, and discuss X-ray and
gamma-ray observations of the prompt and afterglow emission. Except for the
briefness of the prompt event, no other unusual aspects were found in the
prompt and afterglow observations as compared to such measurements in previous
gamma-ray bursts.
[7]
oai:arXiv.org:astro-ph/0001011 [pdf] - 33808
What can BeppoSAX tell us about short GRBs: An update from the Subsecond
GRB Project
Gandolfi, G.;
Feroci, M.;
Costa, E.;
Piro, L.;
Smith, M. J. S.;
Muller, J. M.;
Coletta, A.;
Celidonio, G.;
Di Ciolo, L.;
Paolino, A.;
Tarei, G.;
Tassone, G.;
Frontera, F.
Submitted: 2000-01-03
We present some statistical considerations on the BeppoSAX hunt for subsecond
GRBs at the Scientific Operation Center. Archive analysis of a BATSE/SAX
sub-sample of bursts indicates that the GRB Monitor is sensitive to short (< 2
sec) events, that are in fact about 22% of the total. The non-detection of
corresponding prompt X-ray counterparts to short bursts in the Wide Field
Cameras, in about 3 years of operations, is discussed: with present data no
implications on the X-to-gamma-ray spectra of short vs long GRBs may be
inferred. Finally, the status of searching procedures at SOC is reviewed.
[8]
oai:arXiv.org:astro-ph/9909204 [pdf] - 108240
The 0.1-100 keV spectral shape and variability of Mkn421 in high state
Malizia, A.;
Capalbi, M.;
Fiore, F.;
Giommi, P.;
Gandolfi, G.;
Tesseri, A.;
Antonelli, L. A.;
Butler, R. C.;
Celidonio, G.;
Coletta, A.;
Di Ciolo, L.;
Muller, J. M.;
Piro, L.;
Rebecchi, S.;
Ricci, D.;
Ricci, R.;
Smith, M.;
Torroni, V.
Submitted: 1999-09-13
The results of a BeppoSAX TOO observation of the BL Lac object Mkn421 during
a high intensity state are reported and compared with monitoring X-ray data
collected with the BeppoSAX Wide Field Cameras (WFC) and the RXTE All Sky
Monitor(ASM). The 0.1-100 keV spectrum of Mkn421 shows continuous convex
curvature that can be interpreted as the high-energy end of the synchrotron
emission. The source shows significant short-term temporal and spectral
variability, which can be interpreted in terms of synchrotron cooling. The
comparison of our results with those of previous observations when the source
was a factor 3-5 fainter shows evidence for strong spectral variability, with
the maximum of the synchrotron power shifting to higher energy during high
states. This behaviour suggest an increase in the number of energetic electrons
during high states.
[9]
oai:arXiv.org:astro-ph/9709105 [pdf] - 98558
The Optical Transient of GRB970228, 16 hours after the burst
Pedichini, F.;
Di Paola, A.;
Stella, L.;
Buonanno, R.;
Boattini, A.;
Gandolfi, G.;
Costa, E.;
Feroci, M.;
Piro, L.;
Fiume, D. Dal;
Frontera, F.;
Nicastro, L.;
Palazzi, E.;
Heise, J.;
Zand, J. in't;
Vietri, M.
Submitted: 1997-09-11
Until recently the positions of gamma ray bursts were not sufficiently well
known within a short timescale to localize and identify them with known
celestial sources. Following the historical detection of the X-ray afterglow of
the burst GRB970228, extending from 30 s to 3 days after the main peak, by the
Beppo-SAX satellite and that of an optical transient 21 hr after the burst, we
report here the detection of the same optical transient, in images obtained
only 16 hours after the burst.