Normalized to: Gallina, G.
[1]
oai:arXiv.org:1903.03663 [pdf] - 1920852
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
Gallina, G.;
Giampa, P.;
Retiere, F.;
Kroeger, J.;
Zhang, G.;
Ward, M.;
Margetak, P.;
Lic, G.;
Tsang, T.;
Doria, L.;
Kharusi, S. Al;
Alfaris, M.;
Anton, G.;
Arnquist, I. J.;
Badhrees, I.;
Barbeau, P. S.;
Beck, D.;
Belov, V.;
Bhatta, T.;
Blatchford, J.;
Brodsky, J. P.;
Brown, E.;
Brunner, T.;
Cao, G. F.;
Cao, L.;
Cen, W. R.;
Chambers, C.;
Charlebois, S. A.;
Chiu, M.;
Cleveland, B.;
Coon, M.;
Craycraft, A.;
Dalmasson, J.;
Daniels, T.;
Darroch, L.;
Daugherty, S. J.;
Croix, A. De St.;
Der Mesrobian-Kabakian, A.;
DeVoe, R.;
Dilling, J.;
Ding, Y. Y.;
Dolinski, M. J.;
Dragone, A.;
Echevers, J.;
Elbeltagi, M.;
Fabris, L.;
Fairbank, D.;
Fairbank, W.;
Farine, J.;
Feyzbakhsh, S.;
Fontaine, R.;
Gautam, P.;
Giacomini, G.;
Gornea, R.;
Gratta, G.;
Hansen, E. V.;
Heffner, M.;
Hoppe, E. W.;
Hoßl, J.;
House, A.;
Hughes, M.;
Ito, Y.;
Iverson, A.;
Jamil, A.;
Jewell, M. J.;
Jiang, X. S.;
Karelin, A.;
Kaufman, L. J.;
Kodroff, D.;
Koffas, T.;
Krucken, R.;
Kuchenkov, A.;
Kumar, K. S.;
Lana, Y.;
Larson, A.;
Lenardo, B. G.;
Leonarda, D. S.;
Lik, S.;
Li, Z.;
Licciardi, C.;
Linw, Y. H.;
Lv, P.;
MacLellan, R.;
McElroy, T.;
Medina-Peregrina, M.;
Michel, T.;
Mong, B.;
Moore, D. C.;
Murray, K.;
Nakarmi, P.;
Newby, R. J.;
Ning, Z.;
Njoya, O.;
Nolet, F.;
Nusair, O.;
Odgers, K.;
Odian, A.;
Oriunno, M.;
Orrell, J. L.;
Ortega, G. S.;
Ostrovskiy, I.;
Overman, C. T.;
Parent, S.;
Piepkez, A.;
Pocar, A.;
Pratte, J. -F.;
Qiu, D.;
Radeka, V.;
Raguzin, E.;
Rescia, S.;
Richman, M.;
Robinson, A.;
Rossignol, T.;
Rowson, P. C.;
Roy, N.;
Saldanha, R.;
Sangiorgio, S.;
VIII, K. Skarpaas;
Soma, A. K.;
St-Hilaire, G.;
Stekhanov, V.;
Stiegler, T.;
Sun, X. L.;
Tarka, M.;
Todd, J.;
Tolba, T.;
Totev, T. I.;
Tsang, R.;
Vachon, F.;
Veeraraghavan, V.;
Visser, G.;
Vuilleumier, J. -L.;
Wagenpfeil, M.;
Walent, M.;
Wang, Q.;
Watkins, J.;
Weber, M.;
Wei, W.;
Wen, L. J.;
Wichoski, U.;
Wu, S. X.;
Wu, W. H.;
Wu, X.;
Xia, Q.;
Yang, H.;
Yang, L.;
Yen, Y. -R.;
Zeldovich, O.;
Zhao, J.;
Zhou, Y.;
Ziegler, T.
Submitted: 2019-03-08, last modified: 2019-06-07
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N:
S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers
(SiPMs) as part of the development of a solution for the detection of liquid
xenon scintillation light for the nEXO experiment. Various SiPM features, such
as: dark noise, gain, correlated avalanches, direct crosstalk and Photon
Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs
were characterized in the range $163 \text{ } \text{K} \leq \text{T}\leq 233
\text{ } \text{K}$. At an over voltage of $3.1\pm0.2$ V and at $\text{T}=163
\text{ }\text{K}$ we report a number of Correlated Avalanches (CAs) per pulse
in the $1 \upmu\text{s}$ interval following the trigger pulse of
$0.161\pm0.005$. At the same settings the Dark-Noise (DN) rate is
$0.137\pm0.002 \text{ Hz/mm}^{2}$. Both the number of CAs and the DN rate are
within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two
different devices at $\text{T}=233 \text{ }\text{K}$ for a mean wavelength of
$189\pm7\text{ nm}$. At $3.6\pm0.2$ V and $3.5\pm0.2$ V of over voltage we
report a PDE of $13.4\pm2.6\text{ }\%$ and $11\pm2\%$, corresponding to a
saturation PDE of $14.8\pm2.8\text{ }\%$ and $12.2\pm2.3\%$, respectively. Both
values are well below the $24\text{ }\%$ saturation PDE advertised by
Hamamatsu. More generally, the second device tested at $3.5\pm0.2$ V of over
voltage is below the nEXO PDE requirement. The first one instead yields a PDE
that is marginally close to meeting the nEXO specifications. This suggests that
with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an
alternative to the FBK-LF SiPMs for the final design of the nEXO detector.
[2]
oai:arXiv.org:1609.05016 [pdf] - 1502130
Stability of multiplanet systems in binaries
Submitted: 2016-09-16
When exploring the stability of multiplanet systems in binaries, two
parameters are normally exploited: the critical semimajor axis ac computed by
Holman and Wiegert (1999) within which planets are stable against the binary
perturbations, and the Hill stability limit Delta determining the minimum
separation beyond which two planets will avoid mutual close encounters. Our aim
is to test whether these two parameters can be safely applied in multiplanet
systems in binaries or if their predictions fail for particular binary orbital
configurations. We have used the frequency map analysis (FMA) to measure the
diffusion of orbits in the phase space as an indicator of chaotic behaviour.
First we revisited the reliability of the empirical formula computing ac in the
case of single planets in binaries and we find that, in some cases, it
underestimates by 10-20% the real outer limit of stability. For two planet
systems, the value of Delta is close to that computed for planets around single
stars, but the level of chaoticity close to it substantially increases for
smaller semimajor axes and higher eccentricities of the binary orbit. In these
configurations ac also begins to be unreliable and non linear secular
resonances with the stellar companion lead to chaotic behaviour well within ac,
even for single planet systems. For two planet systems, the superposition of
mean motion resonances, either mutual or with the binary companion, and non
linear secular resonances may lead to chaotic behaviour in all cases. We have
developed a parametric semiempirical formula determining the minimum value of
the binary semimajor axis, for a given eccentricity of the binary orbit, below
which stable two planet systems cannot exist.