Gallie, Angus
Normalized to: Gallie, A.
3 article(s) in total. 102 co-authors. Median position in authors list is 16,0.
[1]
oai:arXiv.org:1805.11931 [pdf] - 1691645
The adaptive optics modes for HARMONI: from Classical to Laser Assisted
Tomographic AO
Neichel, B.;
Fusco, T.;
Sauvage, J. -F.;
Correia, C.;
Dohlen, K.;
El-Hadi, K.;
Blanco, L.;
Schwartz, N.;
Clarke, F.;
Thatte, N.;
Tecza, M.;
Paufique, J.;
Vernet, J.;
Louarn, M. Le;
Hammersley, P.;
Gach, J. -L.;
Pascal, S.;
Vola, P.;
Petit, C.;
Conan, J. -M.;
Carlotti, A.;
Verinaud, C.;
Schnetler, H.;
Bryson, I.;
Morris, T.;
Myers, R.;
Hugot, E.;
Gallie, A.
Submitted: 2018-05-30
HARMONI is a visible and NIR integral field spectrograph, providing the
E-ELT's core spectroscopic capability at first light. HARMONI will work at the
diffraction limit of the E-ELT, thanks to a Classical and a Laser Tomographic
AO system. In this paper, we present the system choices that have been made for
these SCAO and LTAO modules. In particular, we describe the strategy developed
for the different Wave-Front Sensors: pyramid for SCAO, the LGSWFS concept, the
NGSWFS path, and the truth sensor capabilities. We present first potential
implementations. And we asses the first system performance.
[2]
oai:arXiv.org:1508.03070 [pdf] - 1264215
The Mid-Infrared Instrument for the James Webb Space Telescope, VI: The
Medium Resolution Spectrometer
Wells, Martyn;
Pel, J. -W.;
Glasse, Alistair;
Wright, G. S.;
Aitink-Kroes, Gabby;
Azzollini, Ruyman;
Beard, Steven;
Brandl, B. R.;
Gallie, Angus;
Geers, V. C.;
Glauser, A. M.;
Hastings, Peter;
Henning, Th.;
Jager, Rieks;
Justtanont, K.;
Kruizinga, Bob;
Lahuis, Fred;
Lee, David;
Martinez-Delgado, I.;
Martinez-Galarza, J. R.;
Meijers, M.;
Morrison, Jane E.;
Mueller, Friedrich;
Nakos, Thodori;
O'Sullivan, Brian;
Oudenhuysen, Ad;
Parr-Burman, P.;
Pauwels, Evert;
Rohloff, R. -R.;
Schmalzl, Eva;
Sykes, Jon;
Thelen, M. P.;
van Dishoeck, E. F.;
Vandenbussche, Bart;
Venema, Lars B.;
Visser, Huib;
Waters, L. B. F. M.;
Wright, David
Submitted: 2015-08-12
We describe the design and performance of the Medium Resolution Spectrometer
(MRS) for the JWST-MIRI instrument. The MRS incorporates four coaxial spectral
channels in a compact opto-mechanical layout that generates spectral images
over fields of view up to 7.7 X 7.7 arcseconds in extent and at spectral
resolving powers ranging from 1,300 to 3,700. Each channel includes an
all-reflective integral field unit (IFU): an 'image slicer' that reformats the
input field for presentation to a grating spectrometer. Two 1024 X 1024 focal
plane arrays record the output spectral images with an instantaneous spectral
coverage of approximately one third of the full wavelength range of each
channel. The full 5 to 28.5 micron spectrum is then obtained by making three
exposures using gratings and pass-band-determining filters that are selected
using just two three-position mechanisms. The expected on-orbit optical
performance is presented, based on testing of the MIRI Flight Model and
including spectral and spatial coverage and resolution. The point spread
function of the reconstructed images is shown to be diffraction limited and the
optical transmission is shown to be consistent with the design expectations.
[3]
oai:arXiv.org:1205.2957 [pdf] - 1123360
Space-quality data from balloon-borne telescopes: the High Altitude
Lensing Observatory (HALO)
Rhodes, Jason;
Dobke, Benjamin;
Booth, Jeffrey;
Massey, Richard;
Liewer, Kurt;
Smith, Roger;
Amara, Adam;
Aldrich, Jack;
Berge, Joel;
Bezawada, Naidu;
Brugarolas, Paul;
Clark, Paul;
Dubbeldam, Cornelis M.;
Ellis, Richard;
Frenk, Carlos;
Gallie, Angus;
Heavens, Alan;
Henry, David;
Jullo, Eric;
Kitching, Thomas;
Lanzi, James;
Lilly, Simon;
Lunney, David;
Miyazaki, Satoshi;
Morris, David;
Paine, Christopher;
Peacock, John;
Pellegrino, Sergio;
Pittock, Roger;
Pool, Peter;
Refregier, Alexandre;
Seiffert, Michael;
Sharples, Ray;
Smith, Alexandra;
Stuchlik, David;
Taylor, Andy;
Teplitz, Harry;
Vanderveld, R. Ali;
Wu, James
Submitted: 2012-05-14
We present a method for attaining sub-arcsecond pointing stability during
sub- orbital balloon flights, as designed for in the High Altitude Lensing
Observatory (HALO) concept. The pointing method presented here has the
potential to perform near-space quality optical astronomical imaging at 1-2% of
the cost of space-based missions. We also discuss an architecture that can
achieve sufficient thermomechanical stability to match the pointing stability.
This concept is motivated by advances in the development and testing of Ultra
Long Duration Balloon (ULDB) flights which promise to allow observation
campaigns lasting more than three months. The design incorporates a multi-stage
pointing architecture comprising: a gondola coarse azimuth control system, a
multi-axis nested gimbal frame structure with arcsecond stability, a telescope
de-rotator to eliminate field rotation, and a fine guidance stage consisting of
both a telescope mounted angular rate sensor and guide CCDs in the focal plane
to drive a fast-steering mirror. We discuss the results of pointing tests
together with a preliminary thermo-mechanical analysis required for
sub-arcsecond pointing at high altitude. Possible future applications in the
areas of wide-field surveys and exoplanet searches are also discussed.