sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Galan, J.

Normalized to: Galan, J.

14 article(s) in total. 278 co-authors, from 1 to 9 common article(s). Median position in authors list is 7,5.

[1]  oai:arXiv.org:1812.04519  [pdf] - 1983798
Background assessment for the TREX Dark Matter experiment
Comments: Final version, as accepted in Eur. Phys. J. C
Submitted: 2018-12-11, last modified: 2019-09-22
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low background level in the lowest energy region is another essential requirement. To assess the expected background, all the relevant sources have been considered, including the measured fluxes of gamma radiation, muons and neutrons at the Canfranc Laboratory, together with the activity of most of the components used in the detector and ancillary systems, obtained in a complete assay program. The background contributions have been simulated by means of a dedicated application based on Geant4 and a custom-made code for the detector response. The background model developed for the detector presently installed in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive in the search for low-mass WIMPs. A roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
[2]  oai:arXiv.org:1706.05818  [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Comments: Final version as published
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
[3]  oai:arXiv.org:1709.10062  [pdf] - 1589033
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Comments: To appear in the Proceedings of the XV International Conference on Topics in Astroparticle and Underground Physics (TAUP2017) at Journal of Physics: Conference Series (JPCS)
Submitted: 2017-09-28
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a gas time projection chamber equipped with novel micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg of Ne. The micromegas will be read with a self-triggered acquisition, allowing for effective thresholds below 0.4 keV (electron equivalent). The preliminary background model, following a complete material screening program, points to levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive. The status of the commissioning, description of the background model and the corresponding WIMP sensitivity will be presented here.
[4]  oai:arXiv.org:1610.02396  [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Comments: 58 pages, 26 figures, accepted by Physics Reports
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
[5]  oai:arXiv.org:1501.01466  [pdf] - 918435
Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches
Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)
Submitted: 2015-01-07
Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observatory (IAXO). The actual setup in CAST has achieved background levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than the first generation of Micromegas detectors. This reduction is based on active and passive shielding techniques, the selection of radiopure materials, offline discrimination techniques and the high granularity of the readout. We describe in detail the background model of the detector, based on its operation at CAST site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4 simulations. The best levels currently achieved at LSC are low than 10$^{-7}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of this technology in IAXO. Finally, we present some ideas and results for reducing the energy threshold of these detectors below 1 keV, using high-transparent windows, autotrigger electronics and studying the cluster shape at different energies. As a high flux of axion-like-particles is expected in this energy range, a sub-keV threshold detector could enlarge the physics case of axion helioscopes.
[6]  oai:arXiv.org:1412.0161  [pdf] - 904473
Background optimization for a new spherical gas detector for very light WIMP detection
Comments: 5 pages, 3 figures
Submitted: 2014-11-29
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a novel type of par- ticle detector, with a broad range of applications. Its main features include a very low energy threshold independent of the volume (due to its very low capacitance), a good energy resolution, robustness and a single detection readout channel, in its simplest version. Applications range from radon emanation gas monitoring, neutron flux and gamma counting and spectroscopy to dark matter searches, in particular low mass WIMPs and coherent neutrino scattering measure- ment. Laboratories interested in these various applications share expertise within the NEWS (New Experiments With Sphere) network. SEDINE, a low background prototype installed at underground site of Laboratoire Souterrain de Modane is currently being operated and aims at measuring events at very low energy threshold, around 100 eV. We will present the energy cali- bration with 37Ar, the surface background reduction, the measurement of detector background at sub-keV energies, and show anticipated sensitivities for light dark matter search.
[7]  oai:arXiv.org:1307.1985  [pdf] - 867037
CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap
Comments: 5 pages, 2 figures. Last version uploaded
Submitted: 2013-07-08, last modified: 2014-09-15
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of g_a, for example by the currently discussed next generation helioscope IAXO.
[8]  oai:arXiv.org:1401.7902  [pdf] - 778183
NEWS : a new spherical gas detector for very low mass WIMP detection
Comments: 6 pages, 8 figures
Submitted: 2014-01-30
The main characteristics of a new concept of spherical gaseous detectors, with some details on its operation are first given. The very low energy threshold of such detector has led to investigations of its potential performance for dark matter particle searches, in particular low mass WIMP's : original methods for energy and fiducial volume calibration and background rejection are described and preliminary results obtained with a low radioactivity prototype operated in Laboratoire Souterrain de Modane ("Frejus" lab) are presented. Typical expected sensitivities in cross section for low mass WIMP's are also shown, and other applications briefly discussed.
[9]  oai:arXiv.org:1310.4092  [pdf] - 732627
Extending axions searches with a spherical TPC
Comments:
Submitted: 2013-10-15
We present the prospects for detection of KK-axions using a large volume spherical TPC through natural decay to two gammas. The higher excited mass states of this axion model allows to reach densities which could be detectable by this method. We show the capability of this detector to detect 2-prong events coming from rest-mass axion decays and we provide efficiencies obtained under some gas mixtures and pressure conditions. The sensitivity limit of a future experiment with existing detectors geometry has been estimated for the case of zero background limit.
[10]  oai:arXiv.org:1302.6283  [pdf] - 928601
CAST constraints on the axion-electron coupling
Comments:
Submitted: 2013-02-25, last modified: 2013-04-19
In non-hadronic axion models, which have a tree-level axion-electron interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton scattering, and axio-recombination, the "BCA processes." Based on a new calculation of this flux, including for the first time axio-recombination, we derive limits on the axion-electron Yukawa coupling g_ae and axion-photon interaction strength g_ag using the CAST phase-I data (vacuum phase). For m_a < 10 meV/c2 we find g_ag x g_ae< 8.1 x 10^-23 GeV^-1 at 95% CL. We stress that a next-generation axion helioscope such as the proposed IAXO could push this sensitivity into a range beyond stellar energy-loss limits and test the hypothesis that white-dwarf cooling is dominated by axion emission.
[11]  oai:arXiv.org:1102.1406  [pdf] - 958376
Probing eV-mass scale axions with a Micromegas detector in the CAST experiment
Comments: PhD. Thesis
Submitted: 2011-02-07, last modified: 2012-02-21
The CAST (CERN Axion Solar Telescope) experiment is searching for axions, an hypothetical particle that emerges as a possible solution to the well known CP violation problem in strong interactions. CAST is using a decommissioned LHC dipole magnet able to track the Sun as a possible source of solar axions, and to convert them to X-rays photons detectable with low background X-ray detectors. CAST continues its data taking period scanning masses up to 1eV. This thesis presents the data obtained with a Micromegas detector for the scanned axion mass range up to 0.64eV. The working principle, characterization and analysis of the Micromegas detectors operating in CAST are detailed in this work. Moreover, the last detector data corresponding to the new data taking period, with 3He gas inside the bores, was used to obtain a preliminar and conservative upper limit on the axion-photon coupling for the new axion mass range explored, g_{a\gamma} < 2.44 10^{-10} GeV^{-1}.
[12]  oai:arXiv.org:1110.6640  [pdf] - 1091287
Signal propagation and spark mitigation in resistive strips read-outs
Comments: Proceedings of the PSD9 conference
Submitted: 2011-10-30, last modified: 2011-11-01
MicroPattern Gaseous Detectors (MPGD) made of resistive strips have raised as a promising technology for the protection against spark processes having place in the gaseous chamber. The reproduction of the signals and its propagation through the resistive foil is mandatory to better understand its behavior and optimize the key parameters which might depend on the application requirements. In this work it will be presented a resistive-strip model and the charge diffusion through the resistive strip for different model parameters, such as the strip linear resistivity and capacitance, together with the advantages and/or disadvantages of this type of technology.
[13]  oai:arXiv.org:1110.2608  [pdf] - 1084811
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011
Submitted: 2011-10-12, last modified: 2011-10-25
Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have motivated further studies in the nature of the background levels measured. In particular, different shielding configurations have been tested at the Canfranc Underground Laboratory, using a microbulk type detector which was previously running at the CAST experiment. The first results underground show that this technology, which is made of low radiative materials, is able to reach background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a proper shielding. Moreover, the experimental background measurements are complemented with Geant4 simulations which allow to understand the origin of the background, and to optimize future shielding set-ups.
[14]  oai:arXiv.org:0911.0323  [pdf] - 902277
The case for a directional dark matter detector and the status of current experimental efforts
Comments: 48 pages, 37 figures, whitepaper on direct dark matter detection with directional sensitivity
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.