Normalized to: Galan, J.
[1]
oai:arXiv.org:1812.04519 [pdf] - 1983798
Background assessment for the TREX Dark Matter experiment
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Dafni, T.;
Galan, J.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Mirallas, H.;
de Solorzano, A. Ortiz;
Ruiz-Choliz, E.
Submitted: 2018-12-11, last modified: 2019-09-22
TREX-DM is conceived to look for low-mass Weakly Interacting Massive
Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas
readout planes at the Canfranc Underground Laboratory. The detector can hold in
the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30
kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered
acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low
background level in the lowest energy region is another essential requirement.
To assess the expected background, all the relevant sources have been
considered, including the measured fluxes of gamma radiation, muons and
neutrons at the Canfranc Laboratory, together with the activity of most of the
components used in the detector and ancillary systems, obtained in a complete
assay program. The background contributions have been simulated by means of a
dedicated application based on Geant4 and a custom-made code for the detector
response. The background model developed for the detector presently installed
in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region
of interest, making TREX-DM competitive in the search for low-mass WIMPs. A
roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
[2]
oai:arXiv.org:1706.05818 [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Amare, J.;
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Cuesta, C.;
Dafni, T.;
Galan, J.;
Garcia, E.;
Garza, J. G.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Martinez, M.;
Mirallas, H.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Ruiz-Choliz, E.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background
conditions at energies below a few tens of keV. Radioactive isotopes are
produced via cosmogenic activation in detectors and other materials and those
isotopes constitute a background source which has to be under control. In
particular, tritium is specially relevant due to its decay properties (very low
endpoint energy and long half-life) when induced in the detector medium, and
because it can be generated in any material as a spallation product.
Quantification of cosmogenic production of tritium is not straightforward,
neither experimentally nor by calculations. In this work, a method for the
calculation of production rates at sea level has been developed and applied to
some of the materials typically used as targets in dark matter detectors
(germanium, sodium iodide, argon and neon); it is based on a selected
description of tritium production cross sections over the entire energy range
of cosmic nucleons. Results have been compared to available data in the
literature, either based on other calculations or from measurements. The
obtained tritium production rates, ranging from a few tens to a few hundreds of
nuclei per kg and per day at sea level, point to a significant contribution to
the background in dark matter experiments, requiring the application of
specific protocols for target material purification, material storing
underground and limiting the time the detector is on surface during the
building process in order to minimize the exposure to the most dangerous cosmic
ray components.
[3]
oai:arXiv.org:1709.10062 [pdf] - 1589033
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Aznar, F;
Castel, J;
Cebrian, S;
Coarasa, I;
Dafni, T;
Galan, J;
Garza, JG;
Iguaz, FJ;
Irastorza, IG;
Luzon, G;
Mirallas, H;
de Solorzano, A Ortiz;
Ruiz-Choliz, E;
Villar, JA
Submitted: 2017-09-28
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a
gas time projection chamber equipped with novel micromegas readout planes at
the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized
gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg
of Ne. The micromegas will be read with a self-triggered acquisition, allowing
for effective thresholds below 0.4 keV (electron equivalent). The preliminary
background model, following a complete material screening program, points to
levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest,
making TREX-DM competitive. The status of the commissioning, description of the
background model and the corresponding WIMP sensitivity will be presented here.
[4]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[5]
oai:arXiv.org:1501.01466 [pdf] - 918435
Lowering the background level and the energy threshold of Micromegas
x-ray detectors for axion searches
Iguaz, F. J.;
Aune, S.;
Aznar, F.;
Castel, J. F.;
Dafni, T.;
Davenport, M.;
Ferrer-Ribas, E.;
Galan, J.;
Garcia, J. A.;
Garza, J. G.;
Giomataris, I.;
Irastorza, I. G.;
Papaevangelou, T.;
Rodriguez, A.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2015-01-07
Axion helioscopes search for solar axions by their conversion in x-rays in
the presence of high magnetic fields. The use of low background x-ray detectors
is an essential component contributing to the sensitivity of these searches. In
this work, we review the recent advances on Micromegas detectors used in the
CERN Axion Solar Telescope (CAST) and proposed for the future International
Axion Observatory (IAXO). The actual setup in CAST has achieved background
levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than
the first generation of Micromegas detectors. This reduction is based on active
and passive shielding techniques, the selection of radiopure materials, offline
discrimination techniques and the high granularity of the readout. We describe
in detail the background model of the detector, based on its operation at CAST
site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4
simulations. The best levels currently achieved at LSC are low than 10$^{-7}$
keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of
this technology in IAXO. Finally, we present some ideas and results for
reducing the energy threshold of these detectors below 1 keV, using
high-transparent windows, autotrigger electronics and studying the cluster
shape at different energies. As a high flux of axion-like-particles is expected
in this energy range, a sub-keV threshold detector could enlarge the physics
case of axion helioscopes.
[6]
oai:arXiv.org:1412.0161 [pdf] - 904473
Background optimization for a new spherical gas detector for very light
WIMP detection
Dastgheibi-Fard, Ali;
Giomataris, I.;
Gerbierb, G.;
Derree, J.;
Gros, M.;
Magnier, P.;
Jourde, D.;
Bougamont, E .;
Navick, X-F.;
Papaevangelou, T.;
Galan, J.;
Tsiledakis, G.;
Piquemal, F.;
Zampaolo, M.;
Loaiza, P.;
Savvidis, I.
Submitted: 2014-11-29
The Spherical gaseous detector (or Spherical Proportional Counter, SPC) is a
novel type of par- ticle detector, with a broad range of applications. Its main
features include a very low energy threshold independent of the volume (due to
its very low capacitance), a good energy resolution, robustness and a single
detection readout channel, in its simplest version. Applications range from
radon emanation gas monitoring, neutron flux and gamma counting and
spectroscopy to dark matter searches, in particular low mass WIMPs and coherent
neutrino scattering measure- ment. Laboratories interested in these various
applications share expertise within the NEWS (New Experiments With Sphere)
network. SEDINE, a low background prototype installed at underground site of
Laboratoire Souterrain de Modane is currently being operated and aims at
measuring events at very low energy threshold, around 100 eV. We will present
the energy cali- bration with 37Ar, the surface background reduction, the
measurement of detector background at sub-keV energies, and show anticipated
sensitivities for light dark matter search.
[7]
oai:arXiv.org:1307.1985 [pdf] - 867037
CAST solar axion search with 3^He buffer gas: Closing the hot dark
matter gap
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Brauninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Da Riva, E.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Friedrich, P.;
Galan, J.;
Garcia, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Georgiopoulou, E.;
Giomataris, I.;
Gninenko, S.;
Gomez, H.;
Marzoa, M. Gomez;
Gruber, E.;
Guthorl, T.;
Hartmann, R.;
Hauf, S.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovcic, K.;
Karuza, M.;
Konigsmann, K.;
Kotthaus, R.;
Krcmar, M.;
Kuster, M.;
Lakic, B.;
Lang, P. M.;
Laurent, J. M.;
Liolios, A.;
Ljubicic, A.;
Lozza, V.;
Luzon, G.;
Neff, S.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Riege, H.;
Rodriguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Shilon, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomas, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2013-07-08, last modified: 2014-09-15
The CERN Axion Solar Telescope (CAST) has finished its search for solar
axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV.
This closes the gap to the cosmological hot dark matter limit and actually
overlaps with it. From the absence of excess X-rays when the magnet was
pointing to the Sun we set a typical upper limit on the axion-photon coupling
of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on
the pressure setting. Future direct solar axion searches will focus on
increasing the sensitivity to smaller values of g_a, for example by the
currently discussed next generation helioscope IAXO.
[8]
oai:arXiv.org:1401.7902 [pdf] - 778183
NEWS : a new spherical gas detector for very low mass WIMP detection
Gerbier, G.;
Giomataris, I.;
Magnier, P.;
Dastgheibi, A.;
Gros, M.;
Jourde, D.;
Bougamont, E.;
Navick, X. F.;
Papaevangelou, T.;
Galan, J.;
Derre, J.;
Savvidis, I.;
Tsiledakis, G.
Submitted: 2014-01-30
The main characteristics of a new concept of spherical gaseous detectors,
with some details on its operation are first given. The very low energy
threshold of such detector has led to investigations of its potential
performance for dark matter particle searches, in particular low mass WIMP's :
original methods for energy and fiducial volume calibration and background
rejection are described and preliminary results obtained with a low
radioactivity prototype operated in Laboratoire Souterrain de Modane ("Frejus"
lab) are presented. Typical expected sensitivities in cross section for low
mass WIMP's are also shown, and other applications briefly discussed.
[9]
oai:arXiv.org:1310.4092 [pdf] - 732627
Extending axions searches with a spherical TPC
Submitted: 2013-10-15
We present the prospects for detection of KK-axions using a large volume
spherical TPC through natural decay to two gammas. The higher excited mass
states of this axion model allows to reach densities which could be detectable
by this method. We show the capability of this detector to detect 2-prong
events coming from rest-mass axion decays and we provide efficiencies obtained
under some gas mixtures and pressure conditions. The sensitivity limit of a
future experiment with existing detectors geometry has been estimated for the
case of zero background limit.
[10]
oai:arXiv.org:1302.6283 [pdf] - 928601
CAST constraints on the axion-electron coupling
Barth, K.;
Belov, A.;
Beltran, B.;
Brauninger, H.;
Carmona, J. M.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Di Lella, L.;
Eleftheriadis, C.;
Englhauser, J.;
Fanourakis, G.;
Ribas, E. Ferrer;
Fischer, H.;
Franz, J.;
Friedrich, P.;
Galan, J.;
Garcia, J. A.;
Geralis, T.;
Giomataris, I.;
Gninenko, S.;
Gomez, H.;
Hassinoff, M. D.;
Heinsius, F. H.;
Hoffmann, D. H. H.;
Irastorza, I. G.;
Jacoby, J.;
Jakovcic, K.;
Kang, D.;
Konigsmann, K.;
Kotthaus, R.;
Kousouris, K.;
Krcmar, M.;
Kuster, M.;
Lakic, B.;
Liolios, A.;
Ljubicic, A.;
Lutz, G.;
Luzon, G.;
Miller, D. W.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Redondo, J.;
Riege, H.;
Rodriguez, A.;
Ruz, J.;
Savvidis, I.;
Semertzidis, Y.;
Stewart, L.;
Van Bibber, K.;
Vieira, J. D.;
Villar, J. A.;
Vogel, J. K.;
Walckiers, L.;
Zioutas, K.
Submitted: 2013-02-25, last modified: 2013-04-19
In non-hadronic axion models, which have a tree-level axion-electron
interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton
scattering, and axio-recombination, the "BCA processes." Based on a new
calculation of this flux, including for the first time axio-recombination, we
derive limits on the axion-electron Yukawa coupling g_ae and axion-photon
interaction strength g_ag using the CAST phase-I data (vacuum phase). For m_a <
10 meV/c2 we find g_ag x g_ae< 8.1 x 10^-23 GeV^-1 at 95% CL. We stress that a
next-generation axion helioscope such as the proposed IAXO could push this
sensitivity into a range beyond stellar energy-loss limits and test the
hypothesis that white-dwarf cooling is dominated by axion emission.
[11]
oai:arXiv.org:1102.1406 [pdf] - 958376
Probing eV-mass scale axions with a Micromegas detector in the CAST
experiment
Submitted: 2011-02-07, last modified: 2012-02-21
The CAST (CERN Axion Solar Telescope) experiment is searching for axions, an
hypothetical particle that emerges as a possible solution to the well known CP
violation problem in strong interactions. CAST is using a decommissioned LHC
dipole magnet able to track the Sun as a possible source of solar axions, and
to convert them to X-rays photons detectable with low background X-ray
detectors. CAST continues its data taking period scanning masses up to 1eV.
This thesis presents the data obtained with a Micromegas detector for the
scanned axion mass range up to 0.64eV. The working principle, characterization
and analysis of the Micromegas detectors operating in CAST are detailed in this
work. Moreover, the last detector data corresponding to the new data taking
period, with 3He gas inside the bores, was used to obtain a preliminar and
conservative upper limit on the axion-photon coupling for the new axion mass
range explored, g_{a\gamma} < 2.44 10^{-10} GeV^{-1}.
[12]
oai:arXiv.org:1110.6640 [pdf] - 1091287
Signal propagation and spark mitigation in resistive strips read-outs
Submitted: 2011-10-30, last modified: 2011-11-01
MicroPattern Gaseous Detectors (MPGD) made of resistive strips have raised as
a promising technology for the protection against spark processes having place
in the gaseous chamber. The reproduction of the signals and its propagation
through the resistive foil is mandatory to better understand its behavior and
optimize the key parameters which might depend on the application requirements.
In this work it will be presented a resistive-strip model and the charge
diffusion through the resistive strip for different model parameters, such as
the strip linear resistivity and capacitance, together with the advantages
and/or disadvantages of this type of technology.
[13]
oai:arXiv.org:1110.2608 [pdf] - 1084811
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Galan, J.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gomez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Papaevangelou, T.;
Rodriguez, A.;
Ruz, J.;
Segui, L.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2011-10-12, last modified: 2011-10-25
Micromegas detectors, thanks to the good spatial and temporal discrimination
capabilities, are good candidates for rare event search experiments. Recent
X-ray background levels achieved by these detectors in the CAST experiment have
motivated further studies in the nature of the background levels measured. In
particular, different shielding configurations have been tested at the Canfranc
Underground Laboratory, using a microbulk type detector which was previously
running at the CAST experiment. The first results underground show that this
technology, which is made of low radiative materials, is able to reach
background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a
proper shielding. Moreover, the experimental background measurements are
complemented with Geant4 simulations which allow to understand the origin of
the background, and to optimize future shielding set-ups.
[14]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.