Normalized to: Gagnon, R.
[1]
oai:arXiv.org:1902.04048 [pdf] - 1924972
Search for dark matter with a 231-day exposure of liquid argon using
DEAP-3600 at SNOLAB
Ajaj, R.;
Amaudruz, P. -A.;
Araujo, G. R.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bonatt, J.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Cavuoti, S.;
Chen, M.;
Chen, Y.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Doria, L.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Fiorillo, G.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Gallacher, D.;
Garcés, E. A.;
Garg, S.;
Giampa, P.;
Goeldi, D.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Joy, A.;
Jillings, C. J.;
Kamaev, O.;
Kaur, G.;
Kemp, A.;
Kochanek, I.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, X.;
Lidgard, J.;
Lindner, T.;
Litvinov, O.;
Lock, J.;
Longo, G.;
Majewski, P.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Piro, M. -C.;
Pollmann, T. R.;
Rand, E. T.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Viel, S.;
Walding, J.;
Waqar, M.;
Ward, M.;
Westerdale, S.;
Willis, J.;
Zuñiga-Reyes, A.
Submitted: 2019-02-11, last modified: 2019-07-04
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter
experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The
detector consists of 3279 kg of LAr contained in a spherical acrylic vessel.
This paper reports on the analysis of a 758 tonne\cdot day exposure taken over
a period of 231 live-days during the first year of operation. No candidate
signal events are observed in the WIMP-search region of interest, which results
in the leading limit on the WIMP-nucleon spin-independent cross section on a
LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a
100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a
detailed background model, this analysis demonstrates the best pulse-shape
discrimination in LAr at threshold, employs a Bayesian photoelectron-counting
technique to improve the energy resolution and discrimination efficiency, and
utilizes two position reconstruction algorithms based on PMT charge and photon
arrival times.
[2]
oai:arXiv.org:1707.08042 [pdf] - 1735166
First results from the DEAP-3600 dark matter search with argon at SNOLAB
Collaboration, DEAP-3600;
:;
Amaudruz, P. -A.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bishop, D.;
Bonatt, J.;
Boorman, G.;
Boulay, M. G.;
Broerman, B.;
Bromwich, T.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Chan, S.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Dittmeier, S.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Giampa, P.;
Golovko, V. V.;
Gorel, P.;
Gornea, R.;
Grace, E.;
Graham, K.;
Gulyev, E.;
Hakobyan, R.;
Hall, A.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Jillings, C. J.;
Kamaev, O.;
Kemp, A.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Lidgard, J. J.;
Lim, C.;
Lindner, T.;
Linn, Y.;
Liu, S.;
Majewski, P.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McGinn, T.;
McLaughlin, J. B.;
Mead, S.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Muir, A.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ohlmann, C.;
Olchanski, K.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T. R.;
Rand, E. T.;
Rau, W.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Shaw, B.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Taylor, J.;
Veloce, L.;
Vázquez-Jáuregui, E.;
Walding, J.;
Ward, M.;
Westerdale, S.;
Woolsey, E.;
Zielinski, J.
Submitted: 2017-07-25, last modified: 2018-08-13
This paper reports the first results of a direct dark matter search with the
DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was
performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target
mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg
capacity. The LAr is viewed by an array of PMTs, which would register
scintillation light produced by rare nuclear recoil signals induced by dark
matter particle scattering. An analysis of 4.44 live days (fiducial exposure of
9.87 tonne-days) of data taken with the nearly full detector during the initial
filling phase demonstrates the detector performance and the best electronic
recoil rejection using pulse-shape discrimination in argon, with leakage
$<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate
signal events are observed, which results in the leading limit on WIMP-nucleon
spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100
GeV/c$^2$ WIMP mass (90% C.L.).
[3]
oai:arXiv.org:1712.01982 [pdf] - 1832993
Design and Construction of the DEAP-3600 Dark Matter Detector
Amaudruz, P. -A.;
Baldwin, M.;
Batygov, M.;
Beltran, B.;
Bina, C. E.;
Bishop, D.;
Bonatt, J.;
Boorman, G.;
Boulay, M. G.;
Broerman, B.;
Bromwich, T.;
Bueno, J. F.;
Burghardt, P. M.;
Butcher, A.;
Cai, B.;
Chan, S.;
Chen, M.;
Chouinard, R.;
Churchwell, S.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
DiGioseffo, J.;
Dittmeier, S.;
Duncan, F. A.;
Dunford, M.;
Erlandson, A.;
Fatemighomi, N.;
Florian, S.;
Flower, A.;
Ford, R. J.;
Gagnon, R.;
Giampa, P.;
Golovko, V. V.;
Gorel, P.;
Gornea, R.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Gulyev, E.;
Hall, A.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P. J.;
Hearns, C.;
Jillings, C. J.;
Kamaev, O.;
Kemp, A.;
Kuźniak, M.;
Langrock, S.;
La Zia, F.;
Lehnert, B.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lim, C.;
Lindner, T.;
Linn, Y.;
Liu, S.;
Majewski, P.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McGinn, T.;
McLaughlin, J. B.;
Mead, S.;
Mehdiyev, R.;
Mielnichuk, C.;
Monroe, J.;
Muir, A.;
Nadeau, P.;
Nantais, C.;
Ng, C.;
Noble, A. J.;
O'Dwyer, E.;
Ohlmann, C.;
Olchanski, K.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T. R.;
Rand, E. T.;
Rau, W.;
Rethmeier, C.;
Retière, F.;
Seeburn, N.;
Shaw, B.;
Singhrao, K.;
Skensved, P.;
Smith, B.;
Smith, N. J. T.;
Sonley, T.;
Soukup, J.;
Stainforth, R.;
Stone, C.;
Strickland, V.;
Sur, B.;
Tang, J.;
Taylor, J.;
Veloce, L.;
Vázquez-Jáuregui, E.;
Walding, J.;
Ward, M.;
Westerdale, S.;
White, R.;
Woolsey, E.;
Zielinski, J.
Submitted: 2017-12-05, last modified: 2018-04-10
The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has
been designed for a direct detection search for particle dark matter using a
single-phase liquid argon target. The projected cross section sensitivity for
DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive
Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$
WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the
physical properties and construction of the DEAP-3600 detector.
[4]
oai:arXiv.org:1704.01882 [pdf] - 1565347
Application of the TPB Wavelength Shifter to the DEAP-3600 Spherical
Acrylic Vessel Inner Surface
Broerman, B.;
Boulay, M. G.;
Cai, B.;
Cranshaw, D.;
Dering, K.;
Florian, S.;
Gagnon, R.;
Giampa, P.;
Gilmour, C.;
Hearns, C.;
Kezwer, J.;
Kuźniak, M.;
Pollmann, T.;
Ward, M.
Submitted: 2017-04-06
DEAP-3600 uses liquid argon contained in a spherical acrylic vessel as a
target medium to perform a sensitive spin-independent dark matter search. Argon
scintillates in the vacuum ultraviolet spectrum, which requires wavelength
shifting to convert the VUV photons to visible so they can be transmitted
through the acrylic light guides and detected by the surrounding
photomultiplier tubes. The wavelength shifter 1,1,4,4-tetraphenyl-1,3-butadiene
was evaporatively deposited to the inner surface of the acrylic vessel under
vacuum. Two evaporations were performed on the DEAP-3600 acrylic vessel with an
estimated coating thickness of 3.00 $\pm$ 0.02 $\mu$m which is successfully
wavelength shifting with liquid argon in the detector. Details on the
wavelength shifter coating requirements, deposition source, testing, and final
performance are presented.
[5]
oai:arXiv.org:0904.2930 [pdf] - 1488343
Measurement of the scintillation time spectra and pulse-shape
discrimination of low-energy beta and nuclear recoils in liquid argon with
DEAP-1
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bonatt, J.;
Boudjemline, K.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
Duncan, F.;
Fatemighomi, N.;
Ford, R.;
Gagnon, R.;
Giampa, P.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P.;
Hearns, C.;
Hofgartner, J.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
La Zia, F.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
Mehdiyev, R.;
McKinsey, D. N.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, A. J.;
O'Dwyer, E.;
Olsen, K.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T.;
Rau, W.;
Retière, F.;
Ronquest, M.;
Seeburn, N.;
Skensved, P.;
Smith, B.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Walding, J.;
Ward, M.
Submitted: 2009-04-20, last modified: 2016-09-14
The DEAP-1 low-background liquid argon detector was used to measure
scintillation pulse shapes of electron and nuclear recoil events and to
demonstrate the feasibility of pulse-shape discrimination (PSD) down to an
electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction
of beta events that are misidentified as nuclear recoils to be $<1.4\times
10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil
acceptance of at least 90%, with 4% systematic uncertainty on the absolute
energy scale. The discrimination measurement on surface was limited by nuclear
recoils induced by cosmic-ray generated neutrons. This was improved by moving
the detector to the SNOLAB underground laboratory, where the reduced background
rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains $1.23\times10^8$ events. One of those, in the
underground data set, is in the nuclear-recoil region of interest. Taking into
account the expected background of 0.48 events coming from random pileup, the
resulting upper limit on the electronic recoil contamination is
$<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil
acceptance of at least 90%, with 6% systematic uncertainty on the absolute
energy scale.
We developed a general mathematical framework to describe PSD parameter
distributions and used it to build an analytical model of the distributions
observed in DEAP-1. Using this model, we project a misidentification fraction
of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for
a detector with 8 PE/keVee light yield. This reduction enables a search for
spin-independent scattering of WIMPs from 1000 kg of liquid argon with a
WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming
negligible contribution from nuclear recoil backgrounds.
[6]
oai:arXiv.org:1408.1914 [pdf] - 1216195
Improving Photoelectron Counting and Particle Identification in
Scintillation Detectors with Bayesian Techniques
Akashi-Ronquest, M.;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bodmer, M.;
Boulay, M. G.;
Broerman, B.;
Buck, B.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chen, Y.;
Cleveland, B.;
Coakley, K.;
Dering, K.;
Duncan, F. A.;
Formaggio, J. A.;
Gagnon, R.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grace, E.;
Guerrero, N.;
Guiseppe, V.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Henning, R.;
Hime, A.;
Hofgartner, J.;
Jaditz, S.;
Jillings, C. J.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Kuzniak, M.;
LaTorre, A.;
Lawson, I.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Linden, S.;
McFarlane, K.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mathew, R.;
McDonald, A. B.;
Mei, D. -M.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J. A.;
Noble, T.;
O'Dwyer, E.;
Olsen, K.;
Gann, G. D. Orebi;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Perumpilly, G.;
Pollmann, T.;
Rau, P.;
Retiere, F.;
Rielage, K.;
Schnee, R.;
Seibert, S.;
Skensved, P.;
Sonley, T.;
Vazquez-Jauregui, E.;
Veloce, L.;
Walding, J.;
Wang, B.;
Wang, J.;
Ward, M.;
Zhang, C.
Submitted: 2014-08-08, last modified: 2014-12-12
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.