Gabriel, Jean-Francois
Normalized to: Gabriel, J.
2 article(s) in total. 28 co-authors, from 1 to 2 common article(s). Median position in authors list is 12,0.
[1]
oai:arXiv.org:1608.01196 [pdf] - 1531178
Visible camera cryostat design and performance for the SuMIRe Prime
Focus Spectrograph (PFS)
Smee, Stephen A.;
Gunn, James E.;
Golebiowski, Mirek;
Hope, Stephen C.;
Madec, Fabrice;
Gabriel, Jean-Francois;
Loomis, Craig;
Fur, Arnaud Le;
Dohlen, Kjetil;
Mignant, David Le;
Barkhouser, Robert;
Carr, Michael;
Hart, Murdock;
Tamura, Naoyuki;
Shimono, Atsushi;
Takato, Naruhisa
Submitted: 2016-08-03
We describe the design and performance of the SuMIRe Prime Focus Spectrograph
(PFS) visible camera cryostats. SuMIRe PFS is a massively multi-plexed
ground-based spectrograph consisting of four identical spectrograph modules,
each receiving roughly 600 fibers from a 2394 fiber robotic positioner at the
prime focus. Each spectrograph module has three channels covering wavelength
ranges 380~nm -- 640~nm, 640~nm -- 955~nm, and 955~nm -- 1.26~um, with the
dispersed light being imaged in each channel by a f/1.07 vacuum Schmidt camera.
The cameras are very large, having a clear aperture of 300~mm at the entrance
window, and a mass of $\sim$280~kg. In this paper we describe the design of the
visible camera cryostats and discuss various aspects of cryostat performance.
[2]
oai:arXiv.org:1608.01287 [pdf] - 1531180
SUBARU prime focus spectrograph: integration, testing and performance
for the first spectrograph
Madec, F.;
Fur, A. Le;
Mignant, D. Le;
Dohlen, K.;
Barrette, R.;
Belhadi, M.;
Pascal, S.;
Smee, S.;
Gunn, J.;
Merrer, J. Le;
Lorred, M.;
Jaquet, M.;
Balard, P.;
Blanchard, P.;
Thao, W.;
Roman, F.;
Lapere, V.;
Gabriel, JF;
Loomis, C.;
Golebiowski, M.;
Hart, M.;
Oliveira, L.;
Oliveira, A.;
Tamura, N.;
Shimono, A.
Submitted: 2016-08-03
The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and
Redshifts (SuMIRe) project for Subaru telescope consists in four identical
spectrographs fed by 600 fibers each. Each spectrograph is composed by an
optical entrance unit that creates a collimated beam and distributes the light
to three channels, two visibles and one near infrared. This paper presents the
on-going effort for the tests & integration process for the first spectrograph
channel: we have developed a detailed Assembly Integration and Test (AIT) plan,
as well as the methods, detailed processes and I&T tools. We describe the tools
we designed to assemble the parts and to test the performance of the
spectrograph. We also report on the thermal acceptance tests we performed on
the first visible camera unit. We also report on and discuss the technical
difficulties that did appear during this integration phase. Finally, we detail
the important logistic process that is require to transport the components from
other country to Marseille.