Normalized to: Gómez, H.
[1]
oai:arXiv.org:1211.4508 [pdf] - 1157898
Ionization and scintillation response of high-pressure xenon gas to
alpha particles
NEXT Collaboration;
Álvarez, V.;
Borges, F. I. G. M.;
Cárcel, S.;
Cebrián, S.;
Cervera, A.;
Conde, C. A. N.;
Dafni, T.;
Díaz, J.;
Egorov, M.;
Esteve, R.;
Evtoukhovitch, P.;
Fernandes, L. M. P.;
Ferrario, P.;
Ferreira, A. L.;
Freitas, E. D. C.;
Gehman, V. M.;
Gil, A.;
Goldschmidt, A.;
Gómez, H.;
Gómez-Cadenas, J. J.;
González-Díaz, D.;
Gutiérrez, R. M.;
Hauptman, J.;
Morata, J. A. Hernando;
Herrera, D. C.;
Irastorza, I. G.;
Jinete, M. A.;
Labarga, L.;
Laing, A.;
Liubarsky, I.;
Lopes, J. A. M.;
Lorca, D.;
Losada, M.;
Luzón, G.;
Marí, A.;
Martín-Albo, J.;
Miller, T.;
Moiseenko, A.;
Monrabal, F.;
Monteiro, C. M. B.;
Mora, F. J.;
Moutinho, L. M.;
Vidal, J. Muñoz;
da Luz, H. Natal;
Navarro, G.;
Nebot-Guinot, M.;
Nygren, D.;
Oliveira, C. A. B.;
Palma, R.;
Pérez, J.;
Aparicio, J. L. Pérez;
Renner, J.;
Ripoll, L.;
Rodríguez, A.;
Rodríguez, J.;
Santos, F. P.;
Santos, J. M. F. dos;
Segui, L.;
Serra, L.;
Shuman, D.;
Simón, A.;
Sofka, C.;
Sorel, M.;
Toledo, J. F.;
Tomás, A.;
Torrent, J.;
Tsamalaidze, Z.;
Vázquez, D.;
Veloso, J. F. C. A.;
Webb, R.;
White, J. T;
Yahlali, N.
Submitted: 2012-11-19, last modified: 2013-05-21
High-pressure xenon gas is an attractive detection medium for a variety of
applications in fundamental and applied physics. In this paper we study the
ionization and scintillation detection properties of xenon gas at 10 bar
pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO
time projection chamber, the large scale prototype of the NEXT-100 neutrinoless
double beta decay experiment, in three different drift electric field
configurations. We measure the ionization electron drift velocity and
longitudinal diffusion, and compare our results to expectations based on
available electron scattering cross sections on pure xenon. In addition, two
types of measurements addressing the connection between the ionization and
scintillation yields are performed. On the one hand we observe, for the first
time in xenon gas, large event-by-event correlated fluctuations between the
ionization and scintillation signals, similar to that already observed in
liquid xenon. On the other hand, we study the field dependence of the average
scintillation and ionization yields. Both types of measurements may shed light
on the mechanism of electron-ion recombination in xenon gas for highly-ionizing
particles. Finally, by comparing the response of alpha particles and electrons
in NEXT-DEMO, we find no evidence for quenching of the primary scintillation
light produced by alpha particles in the xenon gas.
[2]
oai:arXiv.org:1210.3287 [pdf] - 1152052
Micromegas-TPC operation at high pressure in xenon-trimethylamine
mixtures
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Gonzalez-Diaz, D.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Rodríguez, A.;
Segui, L.;
Tomás, A.
Submitted: 2012-10-11, last modified: 2012-11-23
In this work we present a systematic study of Micromegas detectors in high
pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains
and energy resolutions for 22.1 keV X-rays are measured for pressures between 1
and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We
observe stable operation at all pressures, and a strongly enhanced gas gain,
suggestive of Penning-like energy-transfer processes. The effect is present at
all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3
%. Operating in this concentration range, the maximum gain reached values as
high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable
for 22.1 keV X-rays is substantially better than the one previously obtained in
pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of
interest for calorimetric applications of high pressure gas Xe TPCs, in
particular for the search of the neutrinoless double beta decay of Xe-136. The
resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value
of Xe-136 for 1 (10) bar.
[3]
oai:arXiv.org:1209.6347 [pdf] - 1453905
Results and perspectives of the solar axion search with the CAST
experiment
Ferrer-Ribas, E.;
Arik, M.;
Aune, S.;
Barth, K.;
Belov, A.;
Borghi, S.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Cetin, S. A.;
Collar, J. I.;
Dafni, T.;
Davenport, M.;
Eleftheriadis, C.;
Elias, N.;
Ezer, C.;
Fanourakis, G.;
Friedrich, P.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gazis, E. N.;
Geralis, T.;
Giomataris, I.;
Gninenko, S.;
Gómez, H.;
Gruber, E.;
Guthörl, T.;
Hartmann, R.;
Haug, F.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jacoby, J.;
Jakovčić, K.;
Karuza, M.;
Königsmann, K.;
Kotthaus, R.;
Krčmar, M.;
Kuster, M.;
Lakić, B.;
Laurent, J. M.;
Liolios, A.;
Ljubičić, A.;
Lozza, V.;
Lutz, G.;
Luzón, G.;
Morales, J.;
Niinikoski, T.;
Nordt, A.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Raffelt, G.;
Rashba, T.;
Riege, H.;
Rodríguez, A.;
Rosu, M.;
Ruz, J.;
Savvidis, I.;
Silva, P. S.;
Solanki, S. K.;
Stewart, L.;
Tomás, A.;
Tsagri, M.;
van Bibber, K.;
Vafeiadis, T.;
Villar, J.;
Vogel, J. K.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2012-09-27, last modified: 2012-10-30
The status of the solar axion search with the CERN Axion Solar Telescope
(CAST) will be presented. Recent results obtained by the use of $^3$He as a
buffer gas has allowed us to extend our sensitivity to higher axion masses than
our previous measurements with $^4$He. With about 1 h of data taking at each of
252 different pressure settings we have scanned the axion mass range 0.39 eV$
\le m_{a} \le $ 0.64 eV. From the absence of an excess of x rays when the
magnet was pointing to the Sun we set a typical upper limit on the axion-photon
coupling of g$_{a\gamma} \le 2.3\times 10^{-10}$ GeV$^{-1}$ at 95% C.L., the
exact value depending on the pressure setting. CAST published results represent
the best experimental limit on the photon couplings to axions and other similar
exotic particles dubbed WISPs (Weakly Interacting Slim Particles) in the
considered mass range and for the first time the limit enters the region
favored by QCD axion models. Preliminary sensitivities for axion masses up to
1.16 eV will also be shown reaching mean upper limits on the axion-photon
coupling of g$_{a\gamma} \le 3.5\times 10^{-10}$ GeV$^{-1}$ at 95% C.L.
Expected sensibilities for the extension of the CAST program up to 2014 will be
presented. Moreover long term options for a new helioscope experiment will be
evoked.
[4]
oai:arXiv.org:1208.5690 [pdf] - 771411
CAST microbulk micromegas in the Canfranc Underground Laboratory
Tomás, A.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gómez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Papaevangelou, T.;
Rodríguez, A.;
Ruz, J.;
Seguí, L.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2012-08-28
During the last taking data campaigns of the CAST experiment, the micromegas
detectors have achieved background levels of $\approx 5 \times
10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has
been possible thanks to the introduction of the microbulk technology, the
implementation of a shielding and the development of discrimination algorithms.
It has motivated new studies towards a deeper understanding of CAST detectors
background. One of the working lines includes the construction of a replica of
the set-up used in CAST by micromegas detectors and its installation in the
Canfranc Underground Laboratory. Thanks to the comparison between the
performance of the detectors underground and at surface, shielding upgrades,
etc, different contributions to the detectors background have been evaluated.
In particular, an upper limit $< 2 \times 10^{-7}$keV$^{-1}$cm$^{-2}$s$^{-1}$
for the intrinsic background of the detector has been obtained. This work means
a first evaluation of the potential of the newest micromegas technology in an
underground laboratory, the most suitable environment for Rare Event Searches.
[5]
oai:arXiv.org:1009.1827 [pdf] - 261761
Micromegas readouts for double beta decay searches
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Galán, J.;
García, J. A.;
Giomataris, I.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzón, G.;
Rodríguez, A.;
Seguí, L.;
Tomás, A.
Submitted: 2010-09-09
Double beta $\beta\beta$ decay experiments are one of the most active
research topics in Neutrino Physics. The measurement of the neutrinoless mode
$0\nu\beta\beta$ could give unique information on the neutrino mass scale and
nature. The current generation of experiments aims at detector target masses at
the 100 kg scale, while the next generation will need to go to the ton scale in
order to completely explore the inverse hierarchy models of neutrino mass. Very
good energy resolutions and ultra-low background levels are the two main
experimental requirements for a successful experiment. The topological
information of the $\beta\beta$ events offered by gaseous detectors like gas
Time Projection Chambers (TPC) could provide a very powerful tool of signal
identification and background rejection. However only recent advances in TPC
readouts may assure the competitiveness of a high pressure gas TPCs for
$\beta\beta$ searches, especially regarding the required energy resolution. In
this paper we present first results on energy resolution with state-of-the-art
microbulk Micromesh Gas Amplification Structure (Micromegas) using a 5.5 MeV
alpha source in high pressure pure xenon. Resolutions down to 2 % FWHM have
been achieved for pressures up to 5 bar. These results, together with their
recently measured radiopurity , prove that Micromegas readouts are not only a
viable option but a very competitive one for $\beta\beta$ searches.
[6]
oai:arXiv.org:0706.1636 [pdf] - 2119
Background studies and shielding effects for the TPC detector of the
CAST experiment
Luzón, G.;
Beltrán, B.;
Carmona, J. M.;
Cebrián, S.;
Gómez, H.;
Irastorza, I. G.;
Morales, J.;
Ortíz, A.;
Rodríguez, A.;
Ruz, J.;
Villar, J. A.
Submitted: 2007-06-12
Sunset solar axions traversing the intense magnetic field of the CERN Axion
Solar Telescope (CAST) experiment may be detected in a Time Projection Chamber
(TPC) detector, as X-rays signals. These signals could be masked, however, by
the inhomogeneous background of materials in the experimental site. A detailed
analysis, based on the detector characteristics, the background radiation at
the CAST site, simulations and experimental results, has allowed us to design a
shielding which reduces the background level by a factor of ~4 compared to the
detector without shielding, depending on its position, in the energy range
between 1 and 10 keV. Moreover, this shielding has improved the homogeneity of
background measured by the TPC.
[7]
oai:arXiv.org:0704.2946 [pdf] - 653
Background study for the pn-CCD detector of CERN Axion Solar Telescope
Cebrián, S.;
Rodríguez, A.;
Kuster, M.;
Beltrán, B.;
Carmona, J. M.;
Gómez, H.;
Hartmann, R.;
Irastorza, I. G.;
Kotthaus, R.;
Luzón, G.;
Morales, J.;
de Solórzano, A. Ortiz;
Ruz, J.;
Strüder, L.;
Villar, J. A.
Submitted: 2007-04-23
The CERN Axion Solar Telescope (CAST) experiment searches for axions from the
Sun converted into photons with energies up to around 10 keV via the inverse
Primakoff effect in the high magnetic field of a superconducting Large Hadron
Collider (LHC) prototype magnet. A backside illuminated pn-CCD detector in
conjunction with an X-ray mirror optics is one of the three detectors used in
CAST to register the expected photon signal. Since this signal is very rare and
different background components (environmental gamma radiation, cosmic rays,
intrinsic radioactive impurities in the set-up, ...) entangle it, a detailed
study of the detector background has been undertaken with the aim to understand
and further reduce the background level of the detector. The analysis is based
on measured data taken during the Phase I of CAST and on Monte Carlo
simulations of different background components. This study will show that the
observed background level (at a rate of (8.00+-0.07)10^-5 counts/cm^2/s/keV
between 1 and 7 keV) seems to be dominated by the external gamma background due
to usual activities at the experimental site, while radioactive impurities in
the detector itself and cosmic neutrons could make just smaller contribution.