sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Gómez, H.

Normalized to: Gómez, H.

7 article(s) in total. 145 co-authors, from 1 to 7 common article(s). Median position in authors list is 7,0.

[1]  oai:arXiv.org:1211.4508  [pdf] - 1157898
Ionization and scintillation response of high-pressure xenon gas to alpha particles
Comments: 36 pages, 19 figures, 5 tables. Version accepted for publication in JINST
Submitted: 2012-11-19, last modified: 2013-05-21
High-pressure xenon gas is an attractive detection medium for a variety of applications in fundamental and applied physics. In this paper we study the ionization and scintillation detection properties of xenon gas at 10 bar pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO time projection chamber, the large scale prototype of the NEXT-100 neutrinoless double beta decay experiment, in three different drift electric field configurations. We measure the ionization electron drift velocity and longitudinal diffusion, and compare our results to expectations based on available electron scattering cross sections on pure xenon. In addition, two types of measurements addressing the connection between the ionization and scintillation yields are performed. On the one hand we observe, for the first time in xenon gas, large event-by-event correlated fluctuations between the ionization and scintillation signals, similar to that already observed in liquid xenon. On the other hand, we study the field dependence of the average scintillation and ionization yields. Both types of measurements may shed light on the mechanism of electron-ion recombination in xenon gas for highly-ionizing particles. Finally, by comparing the response of alpha particles and electrons in NEXT-DEMO, we find no evidence for quenching of the primary scintillation light produced by alpha particles in the xenon gas.
[2]  oai:arXiv.org:1210.3287  [pdf] - 1152052
Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures
Comments:
Submitted: 2012-10-11, last modified: 2012-11-23
In this work we present a systematic study of Micromegas detectors in high pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains and energy resolutions for 22.1 keV X-rays are measured for pressures between 1 and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We observe stable operation at all pressures, and a strongly enhanced gas gain, suggestive of Penning-like energy-transfer processes. The effect is present at all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3 %. Operating in this concentration range, the maximum gain reached values as high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable for 22.1 keV X-rays is substantially better than the one previously obtained in pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of interest for calorimetric applications of high pressure gas Xe TPCs, in particular for the search of the neutrinoless double beta decay of Xe-136. The resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value of Xe-136 for 1 (10) bar.
[3]  oai:arXiv.org:1209.6347  [pdf] - 1453905
Results and perspectives of the solar axion search with the CAST experiment
Comments: 4 pages, 2 pages, to appear in the proceedings of the 24th Rencontres de Blois V2 A few affiliations were not corrected in previous version V3 Author added
Submitted: 2012-09-27, last modified: 2012-10-30
The status of the solar axion search with the CERN Axion Solar Telescope (CAST) will be presented. Recent results obtained by the use of $^3$He as a buffer gas has allowed us to extend our sensitivity to higher axion masses than our previous measurements with $^4$He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV$ \le m_{a} \le $ 0.64 eV. From the absence of an excess of x rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g$_{a\gamma} \le 2.3\times 10^{-10}$ GeV$^{-1}$ at 95% C.L., the exact value depending on the pressure setting. CAST published results represent the best experimental limit on the photon couplings to axions and other similar exotic particles dubbed WISPs (Weakly Interacting Slim Particles) in the considered mass range and for the first time the limit enters the region favored by QCD axion models. Preliminary sensitivities for axion masses up to 1.16 eV will also be shown reaching mean upper limits on the axion-photon coupling of g$_{a\gamma} \le 3.5\times 10^{-10}$ GeV$^{-1}$ at 95% C.L. Expected sensibilities for the extension of the CAST program up to 2014 will be presented. Moreover long term options for a new helioscope experiment will be evoked.
[4]  oai:arXiv.org:1208.5690  [pdf] - 771411
CAST microbulk micromegas in the Canfranc Underground Laboratory
Comments: 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011)
Submitted: 2012-08-28
During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of $\approx 5 \times 10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies towards a deeper understanding of CAST detectors background. One of the working lines includes the construction of a replica of the set-up used in CAST by micromegas detectors and its installation in the Canfranc Underground Laboratory. Thanks to the comparison between the performance of the detectors underground and at surface, shielding upgrades, etc, different contributions to the detectors background have been evaluated. In particular, an upper limit $< 2 \times 10^{-7}$keV$^{-1}$cm$^{-2}$s$^{-1}$ for the intrinsic background of the detector has been obtained. This work means a first evaluation of the potential of the newest micromegas technology in an underground laboratory, the most suitable environment for Rare Event Searches.
[5]  oai:arXiv.org:1009.1827  [pdf] - 261761
Micromegas readouts for double beta decay searches
Comments: 15 pages, 11 figures. Accepted for publication in JCAP
Submitted: 2010-09-09
Double beta $\beta\beta$ decay experiments are one of the most active research topics in Neutrino Physics. The measurement of the neutrinoless mode $0\nu\beta\beta$ could give unique information on the neutrino mass scale and nature. The current generation of experiments aims at detector target masses at the 100 kg scale, while the next generation will need to go to the ton scale in order to completely explore the inverse hierarchy models of neutrino mass. Very good energy resolutions and ultra-low background levels are the two main experimental requirements for a successful experiment. The topological information of the $\beta\beta$ events offered by gaseous detectors like gas Time Projection Chambers (TPC) could provide a very powerful tool of signal identification and background rejection. However only recent advances in TPC readouts may assure the competitiveness of a high pressure gas TPCs for $\beta\beta$ searches, especially regarding the required energy resolution. In this paper we present first results on energy resolution with state-of-the-art microbulk Micromesh Gas Amplification Structure (Micromegas) using a 5.5 MeV alpha source in high pressure pure xenon. Resolutions down to 2 % FWHM have been achieved for pressures up to 5 bar. These results, together with their recently measured radiopurity , prove that Micromegas readouts are not only a viable option but a very competitive one for $\beta\beta$ searches.
[6]  oai:arXiv.org:0706.1636  [pdf] - 2119
Background studies and shielding effects for the TPC detector of the CAST experiment
Comments: 14 pages, 5 figures, accepted in New Journal of Physics
Submitted: 2007-06-12
Sunset solar axions traversing the intense magnetic field of the CERN Axion Solar Telescope (CAST) experiment may be detected in a Time Projection Chamber (TPC) detector, as X-rays signals. These signals could be masked, however, by the inhomogeneous background of materials in the experimental site. A detailed analysis, based on the detector characteristics, the background radiation at the CAST site, simulations and experimental results, has allowed us to design a shielding which reduces the background level by a factor of ~4 compared to the detector without shielding, depending on its position, in the energy range between 1 and 10 keV. Moreover, this shielding has improved the homogeneity of background measured by the TPC.
[7]  oai:arXiv.org:0704.2946  [pdf] - 653
Background study for the pn-CCD detector of CERN Axion Solar Telescope
Comments: Comments: 10 pages, 9 figures and images, submitted to Astroparticle Physics
Submitted: 2007-04-23
The CERN Axion Solar Telescope (CAST) experiment searches for axions from the Sun converted into photons with energies up to around 10 keV via the inverse Primakoff effect in the high magnetic field of a superconducting Large Hadron Collider (LHC) prototype magnet. A backside illuminated pn-CCD detector in conjunction with an X-ray mirror optics is one of the three detectors used in CAST to register the expected photon signal. Since this signal is very rare and different background components (environmental gamma radiation, cosmic rays, intrinsic radioactive impurities in the set-up, ...) entangle it, a detailed study of the detector background has been undertaken with the aim to understand and further reduce the background level of the detector. The analysis is based on measured data taken during the Phase I of CAST and on Monte Carlo simulations of different background components. This study will show that the observed background level (at a rate of (8.00+-0.07)10^-5 counts/cm^2/s/keV between 1 and 7 keV) seems to be dominated by the external gamma background due to usual activities at the experimental site, while radioactive impurities in the detector itself and cosmic neutrons could make just smaller contribution.