sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Fushimi, K.

Normalized to: Fushimi, K.

21 article(s) in total. 134 co-authors, from 1 to 20 common article(s). Median position in authors list is 26,0.

[1]  oai:arXiv.org:2005.11891  [pdf] - 2112667
Search for exotic neutrino-electron interactions using solar neutrinos in XMASS-I
Comments:
Submitted: 2020-05-24
We have searched for exotic neutrino-electron interactions that could be produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed no significant signals in 711 days of data. We obtain an upper limit for neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level assuming all three species of neutrino have common millicharge. We also set flavor dependent limits assuming the respective neutrino flavor is the only one carrying a millicharge, $7.3 \times 10^{-12} e$ for $\nu_e$, $1.1 \times 10^{-11} e$ for $\nu_{\mu}$, and $1.1 \times 10^{-11} e$ for $\nu_{\tau}$. These limits are the most stringent yet obtained from direct measurements. We also obtain an upper limit for the neutrino magnetic moment of 1.8$\times$10$^{-10}$ Bohr magnetons. In addition, we obtain upper limits for the coupling constant of dark photons in the $U(1)_{B-L}$ model of 1.3$\times$10$^{-6}$ if the dark photon mass is 1$\times 10^{-3}$ MeV$/c^{2}$, and 8.8$\times$10$^{-5}$ if it is 10 MeV$/c^{2}$.
[2]  oai:arXiv.org:1809.05358  [pdf] - 1851548
Search for WIMP-$^{129}$Xe inelastic scattering with particle identification in XMASS-I
Comments: 8 pages, 10 figures
Submitted: 2018-09-14, last modified: 2019-03-19
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classification based on scintillation timing that distinguished $\gamma$-rays and $\beta$-rays, and simultaneous fitting of the energy spectra of $\gamma$-like and $\beta$-like samples. No evidence of a WIMP signal was found. Thus, we set the upper limits of the inelastic channel cross section at 90\% confidence level, for example, $4.1\times 10^{-39} \;{\rm cm^2}$ for a $200\; {\rm GeV}/c^2$ WIMP. This result provides the most stringent limits on the SD WIMP-neutron interaction and is better by a factor of 7.7 at $200\;{\rm GeV}/c^2$ than the existing experimental limit.
[3]  oai:arXiv.org:1808.03617  [pdf] - 1822844
Development of low radioactivity photomultiplier tubes for the XMASS-I detector
Comments: 7 pages, 3 figures
Submitted: 2018-08-10, last modified: 2019-01-29
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During development, the largest contributions to the reduction of radioactivity came from the stem and the dynode support. The glass stem was exchanged to the Kovar alloy one and the ceramic support were changed to the quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted these materials for low background purposes and provided a groundbreaking step for further reductions of radioactivity in PMTs. Measurements with germanium detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of $^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of $^{60}$Co. In this paper, the radioactive details of the developed R10789 are described together with our screening methods and the components of the PMT.
[4]  oai:arXiv.org:1804.02180  [pdf] - 1806000
A direct dark matter search in XMASS-I
Comments: 16 pages, 8 figures
Submitted: 2018-04-06, last modified: 2018-12-25
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm 5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining events are consistent with our background evaluation, mostly of the "mis-reconstructed events" originated from $^{210}$Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \, cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
[5]  oai:arXiv.org:1808.06177  [pdf] - 1901740
Search for sub-GeV dark matter by annual modulation using XMASS-I detector
Comments: 7 pages, 5 figures
Submitted: 2018-08-19, last modified: 2018-12-22
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
[6]  oai:arXiv.org:1807.08516  [pdf] - 1786927
Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector
Comments: 18 pages, 5 figures
Submitted: 2018-07-23, last modified: 2018-11-18
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $\alpha' / \alpha$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $\alpha' / \alpha < 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.
[7]  oai:arXiv.org:1801.10096  [pdf] - 1690355
Direct dark matter search by annual modulation with 2.7 years of XMASS-I data
Comments: 10 pages, 11 figures
Submitted: 2018-01-30, last modified: 2018-05-25
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more than one year of additional data, which more than doubles the exposure to 800 live days with the same 832 kg target mass. When we assume weakly interacting massive particle (WIMP) dark matter elastically scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ at 90\% confidence level with our newly implemented data selection through a likelihood method. For the model-independent case, without assuming any specific dark matter model, we obtained more consistency with the null hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy region. This search probed this region with an exposure that was larger than that of DAMA/LIBRA. We also did not find any significant amplitude in the data for periodicity with periods between 50 and 600 days in the energy region between 1 to 6 keV.
[8]  oai:arXiv.org:1707.08995  [pdf] - 1586478
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Comments: 11 pages, 6 figures, published in PTEP
Submitted: 2017-07-19, last modified: 2017-11-15
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $\delta = 2$ that axions can propagate in.
[9]  oai:arXiv.org:1705.00110  [pdf] - 1570379
Search for cosmic dark matter by means of ultra high purity NaI(Tl) scintillator
Comments: 8 pages, 5 figures. Proceedings of 31st Workshop on Radiation Detector and Their Uses, January 23-25, 2017. KEK, JAPAN
Submitted: 2017-04-28
The dark matter search project by means of ultra high purity NaI(Tl) scintillator is now underdevelopment. An array of large volume NaI(Tl) detectors whose volume is 12.7 cm$\phi\times$12.7 cm is applied to search for dark matter signal. To remove radioactive impurities in NaI(Tl) crystal is one of the most important task to find small number of dark matter signals. We have developed high purity NaI(Tl) crystal which contains small amounts of radioactive impurities, $<4$ ppb of $^{nat}$K, 0.3 ppt of Th chain, 58 $\mu$Bq/kg of $^{226}$Ra and 30 $\mu$Bq/kg of $^{210}$Pb. Future prospects to search for dark matter by means of a large volume and high purity NaI(Tl) scintillator is discussed.
[10]  oai:arXiv.org:1611.00802  [pdf] - 1532411
Calculated WIMP signals at the ANDES laboratory: comparison with northern and southern located dark matter detectors
Comments: 16 pages, 12 figures. Accepted for publication into Journal of physics G
Submitted: 2016-11-02
Weakly Interacting Massive Particles (WIMP) are possible components of the Universe's Dark Matter. The detection of WIMP is signalled by the recoil of the atomic nuclei which form a detector. CoGeNT at the Soudan Underground Laboratory (SUL) and DAMA at the Laboratori Nazionali del Gran Sasso (LNGS) have reported data on annual modulation of signals attributed to WIMP. Both experiments are located in laboratories of the northern hemisphere. Dark matter detectors are planned to operate (or already operate) in laboratories of the southern hemisphere, like SABRE at Stawell Underground Physics Laboratory (SUPL) in Australia, and DM-ICE in the South Pole. In this work we have analysed the dependence of diurnal and annual modulation of signals, pertaining to the detection of WIMP, on the coordinates of the laboratory, for experiments which may be performed in the planned new underground facility ANDES (Agua Negra Deep Experimental Site), to be built in San Juan, Argentina. We made predictions for NaI and Ge-type detectors placed in ANDES, to compare with DAMA, CoGeNT, SABRE and DM-ICE arrays, and found that the diurnal modulation of the signals, at the site of ANDES, is amplified at its maximum value, both for NaI (Ge)-type detectors, while the annual modulation remains unaffected by the change in coordinates from north to south.
[11]  oai:arXiv.org:1606.07155  [pdf] - 1494732
Search for electron antineutrinos associated with gravitational wave events GW150914 and GW151226 using KamLAND
Comments: 11 pages, 4 figures, as published in ApJL. Updated to replace power law spectrum with Fermi Dirac spectrum
Submitted: 2016-06-22, last modified: 2016-10-03
We present a search for low energy antineutrino events coincident with the gravitational wave events GW150914 and GW151226, and the candidate event LVT151012 using KamLAND, a kiloton-scale antineutrino detector. We find no inverse beta-decay neutrino events within $\pm 500$ seconds of either gravitational wave signal. This non-detection is used to constrain the electron antineutrino fluence and the luminosity of the astrophysical sources.
[12]  oai:arXiv.org:1604.01503  [pdf] - 1458949
A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector
Comments: 7 pages, 3 figures, accepted for publication in Nucl. Instrum. Meth. A
Submitted: 2016-04-06, last modified: 2016-08-18
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $\tau_1$ and $\tau_2$, the decay time constant $\tau_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $\tau_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $\tau_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.
[13]  oai:arXiv.org:1511.04807  [pdf] - 1413079
Direct dark matter search by annual modulation in XMASS-I
Comments: 5 pages, 4 figures
Submitted: 2015-11-15, last modified: 2016-05-25
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$\gamma$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.
[14]  oai:arXiv.org:1605.04999  [pdf] - 1530708
High purity NaI(Tl) scintillator to search for dark matter
Comments: 6 pages, 2 Figures, Proceedings of International Symposium on Radiation Detectors and Their Uses (ISRD2016). Talk given on 19th Jan. 2016 by K.Fushimi. To be published in Proceedings will be published as JPS conference proceedings (2016)
Submitted: 2016-05-16
A high purity and large volume NaI(Tl) scintillator was developed to search for cosmic dark matter. The required densities of radioactive impurities (RIs) such as U-chain, Th-chain are less than a few ppt to establish high sensitivity to dark matter. The impurity of RIs were effectively reduced by selecting raw materials of crucible and by performing chemical reduction of lead ion in NaI raw powder. The impurity of $^{226}$Ra was reduced less than 100 $\mu$Bq/kg in NaI(Tl) crystal. It should be remarked that the impurity of $^{210}$Pb, which is difficult to reduce, is effectively reduced by chemical processing of NaI raw powder down to less than 30 $\mu$Bq/kg. The expected sensitivity to cosmic dark matter by using 250 kg of the high purity and large volume NaI(Tl) scintillator (PICO-LON; Pure Inorganic Crystal Observatory for LOw-background Neutr(al)ino) is 7$\times$10$^{-45}$ cm$^{2}$ for 50 GeV$/c^{2}$ WIMPs.
[15]  oai:arXiv.org:1506.01175  [pdf] - 1358787
KamLAND Sensitivity to Neutrinos from Pre-Supernova Stars
Comments: 19 pages, 6 figures, 1 table
Submitted: 2015-06-03, last modified: 2016-01-22
In the late stages of nuclear burning for massive stars ($M>8~M_{\sun}$), the production of neutrino-antineutrino pairs through various processes becomes the dominant stellar cooling mechanism. As the star evolves, the energy of these neutrinos increases and in the days preceding the supernova a significant fraction of emitted electron anti-neutrinos exceeds the energy threshold for inverse beta decay on free hydrogen. This is the golden channel for liquid scintillator detectors because the coincidence signature allows for significant reductions in background signals. We find that the kiloton-scale liquid scintillator detector KamLAND can detect these pre-supernova neutrinos from a star with a mass of $25~M_{\sun}$ at a distance less than 690~pc with 3$\sigma$ significance before the supernova. This limit is dependent on the neutrino mass ordering and background levels. KamLAND takes data continuously and can provide a supernova alert to the community.
[16]  oai:arXiv.org:1512.04645  [pdf] - 1426203
Dark matter search project PICO-LON
Comments: Submitted to Proceedings of TAUP 2015
Submitted: 2015-12-14
The PICO-LON project aims at search for cold dark matter by means of highly radio-pure and large volume NaI(Tl) scintillator. The NaI powder was purifed by chemical processing to remove lead isotopes and selecting a high purity graphite crucible. The concentrations of radioactive impurities of $^{226}$Ra and $^{228}$Th were effectively reduced to 58$\pm$4 $\mu$Bq/kg and 1.5$\pm$1.9 $\mu$Bq/kg, respectively. It should be remarked that the concentration of $^{210}$Pb, which is crucial for the sensitivity to dark matter, was reduced to 24$\pm$2 $\mu$Bq/kg. The total background rate at 10 keVee was as low as 8 keV$^{-1}$kg$^{-1}$day$^{-1}$, which was sufficiently low to search for dark matter. Further purification of NaI(Tl) ingot and future prospect of PICO-LON project is discussed.
[17]  oai:arXiv.org:1503.02137  [pdf] - 1175829
Study of electron anti-neutrinos associated with gamma-ray bursts using KamLAND
Comments: 16 pages and 5 figures
Submitted: 2015-03-07, last modified: 2015-06-15
We search for electron anti-neutrinos ($\overline{\nu}_e$) from long and short-duration gamma-ray bursts~(GRBs) using data taken by the KamLAND detector from August 2002 to June 2013. No statistically significant excess over the background level is found. We place the tightest upper limits on $\overline{\nu}_e$ fluence from GRBs below 7 MeV and place first constraints on the relation between $\overline{\nu}_e$ luminosity and effective temperature.
[18]  oai:arXiv.org:1407.3542  [pdf] - 1398605
KamLAND-PICO project to search for cosmic dark matter
Comments: 6 pages 5 figures, Proceedings of the 26th Workshop on "Radiation Detectors and Their Uses" January 26-28 20214. KEK Tsukuba Japan. Accepted for publication
Submitted: 2014-07-14
KamLAND-PICO project aims to search for WIMPs dark matter by means of NaI(Tl) scintillator. To investigate the WIMPs candidate whose cross section is as small as $10^{-9}$ pb, a pure NaI(Tl) crystal was developed by chemical processing and taking care of surroundings. The concentration of U and Th chain was reduced to $5.4\pm0.9$ ppt and $3.3\pm2.2$ ppt, respectively. It should be remarked that the concentration of $^{210}$Pb which was difficult to reduce reached to the high purity as $58\pm26$ $\mu$Bq/kg.
[19]  oai:arXiv.org:1203.4872  [pdf] - 832323
The Performance of the Thin NaI(Tl) Detector Pico-Lon for Dark Matter Search
Comments: 7pages, 7figures, Proceedings of the 26th Workshop on Radiation Detectors and Their Uses, KEK-Proc1225008, (2012) p122
Submitted: 2012-03-21, last modified: 2014-06-05
Thin and large area NaI(Tl) scintillator to search for WIMPs dark matter was developed. The performance of thin and wide area NaI(Tl) showed good enough to search for dark matter. The energy threshold was as low as 2keV and the energy resolution was about 24% in FWHM at 60keV.
[20]  oai:arXiv.org:astro-ph/0611700  [pdf] - 1510608
WIMPs search by exclusive measurements with thin multilayer NaI(Tl) scintillators (PICO-LON)
Comments: Proceeding of IDM2006
Submitted: 2006-11-21, last modified: 2006-12-01
The WIMPs search project PICO-LON has been started with multilayer thin NaI(Tl) crystals. The thin (0.05cm) and wide area (5cmx5cm) NaI(Tl) crystals was successfully developed. The performances of thin NaI(Tl) scintillator was measured and they showed good energy resolution (20% at 60keV) and good position resolution (20% in 5cmx5cm wider area).
[21]  oai:arXiv.org:astro-ph/0506329  [pdf] - 73729
WIMPs search by means of the highly segmented scintillator
Comments: 11 pages, added some sentences to make the arguments clear
Submitted: 2005-06-14, last modified: 2005-08-04
The highly sensitive method to search for WIMPs dark matter particles is proposed. An array of thin NaI(Tl) plate has the great selectivity for distinguishing the WIMPs events and background ones. The principle of signal selection for WIMPs is described. The high sensitivity for SD (spin-dependent) type WIMPs is expected by applying multi-layer system of NaI(Tl) detector.